Event Notification Report for October 15, 2002
U.S. Nuclear Regulatory Commission Operations Center Event Reports For 10/11/2002 - 10/15/2002 ** EVENT NUMBERS ** 39250 39261 39269 39270 39271 39272 39274 39275 39276 39277 39278 39279 39280 39281 39282 39283 !!!!!!!!! THIS EVENT HAS BEEN RETRACTED. THIS EVENT HAS BEEN RETRACTED !!!!!!! +------------------------------------------------------------------------------+ |Power Reactor |Event Number: 39250 | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ | FACILITY: VERMONT YANKEE REGION: 1 |NOTIFICATION DATE: 10/06/2002| | UNIT: [1] [] [] STATE: VT |NOTIFICATION TIME: 18:00[EDT]| | RXTYPE: [1] GE-4 |EVENT DATE: 10/06/2002| +------------------------------------------------+EVENT TIME: 11:30[EDT]| | NRC NOTIFIED BY: MITCH McCLUSKIE |LAST UPDATE DATE: 10/11/2002| | HQ OPS OFFICER: FANGIE JONES +-----------------------------+ +------------------------------------------------+PERSON ORGANIZATION | |EMERGENCY CLASS: NON EMERGENCY |PETE ESELGROTH R1 | |10 CFR SECTION: | | |AIND 50.72(b)(3)(v)(D) ACCIDENT MITIGATION | | | | | | | | | | | +-----+----------+-------+--------+-----------------+--------+-----------------+ |UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE | +-----+----------+-------+--------+-----------------+--------+-----------------+ |1 N N 0 Refueling |0 Refueling | | | | | | | +------------------------------------------------------------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | RCIC SYSTEM DECLARED INOPERABLE | | | | Following reactor core isolation cooling system injection check valve | | surveillance, the check valve apparently did not fully close. This resulted | | in high pump suction pressure trip which would have prevented further system | | operation. The licensee conservatively declared the RCIC system inoperable | | and entered Tech Spec LCO 3.5.G.2, a 14 day action statement. Shortly | | afterwards the plant pressure was dropped to less than 150 psig as part of | | normal plant shutdown to refueling, this takes the plant out of the Tech | | Spec action statement as it no longer applies. The licensee is conducting | | an investigation of the problem with RCIC injection check valve. Repairs | | will be completed prior to plant restart. | | | | The licensee notified the NRC Resident Inspector and the State of Vermont. | | | | * * * RETRACTION FROM Andy Wisniewski on 10/11/02 at 1428 EDT to Gerry Waig | | * * * | | | | "BASIS FOR RETRACTION: | | | | NRC Event Notification 39250 was made with the concern that this condition | | may have rendered the Reactor Core Isolation Cooling (RCIC) system | | inoperable due to a 'high pump suction pressure trip'. The RCIC pump does | | not have this aforementioned trip device. Therefore, the predicament that | | Operations has been confronted with for declaring the RCIC system inoperable | | may be more aptly stated as; 'Could the leakage that occurred past the | | discharge check valve, after the RCIC system run, have over-pressurized the | | RCIC system suction piping and caused the system to be unavailable for | | service if called upon for a 'Loss of All AC Event'. A team of engineers was | | assembled to determine the extent of this condition that resulted in the | | completion of an Operability Determination on 10/08/02 by the RCIC System | | Engineer, concluding that the RCIC system remained operable based upon the | | following two facts: | | | | 1. The RCIC suction line relief valve lifts at 150 psi. | | 2. The outer pump discharge valve, combined with a pressure switch, provides | | an additional barrier of defense. The pressure switch actuates at 74 psi and | | causes the RCIC PUMP SUCT PRESS HI alarm in the control room. The alarm | | response procedure directs operators to close the isolation valve that is | | downstream of the discharge check valve. | | | | "Additionally, the leakage has been determined to be 'slight' and well | | within the capacity of the relief valve, based upon system performance and | | observation of the event as it occurred. The RCIC system would have | | performed it's specified safety function during this condition if required. | | | | "Therefore, ENS Event Number 39250, made on 10/06/02, is being retracted." | | | | The licensee notified the NRC Resident Inspector of this retraction. The | | R1DO (John White) was notified by the NRC Headquarters Operations Officer. | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ |General Information or Other |Event Number: 39261 | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ | REP ORG: ILLINOIS DEPT OF NUCLEAR SAFETY |NOTIFICATION DATE: 10/09/2002| |LICENSEE: HARRY W. KUHN, INC. |NOTIFICATION TIME: 11:33[EDT]| | CITY: CHICAGO REGION: 3 |EVENT DATE: 10/08/2002| | COUNTY: STATE: IL |EVENT TIME: 07:30[CDT]| |LICENSE#: IL-01870-01 AGREEMENT: Y |LAST UPDATE DATE: 10/09/2002| | DOCKET: |+----------------------------+ | |PERSON ORGANIZATION | | |CHRIS MILLER R3 | | |DOUG BROADDUS NMSS | +------------------------------------------------+ | | NRC NOTIFIED BY: TOM SEIF | | | HQ OPS OFFICER: MIKE RIPLEY | | +------------------------------------------------+ | |EMERGENCY CLASS: NON EMERGENCY | | |10 CFR SECTION: | | |NAGR AGREEMENT STATE | | | | | | | | | | | | | | +------------------------------------------------------------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | AGREEMENT STATE REPORT INVOLVING LOST TROXLER GAUGE | | | | At 1133 EDT, the Illinois Dept. of Nuclear Safety (IDNS) reported that a | | materials licensee reported that a Troxler Gauge (Model 3440, S/N 24468 with | | 8 millicuries Cesium-137 and 40 millicuries Americium-241) was lost from the | | back of a pickup truck while being transported between 7:30 am and 8:00 am | | on 10/8/02. The licensee reported that the worker picked up the gauge at | | the licensee's facility, then drove to his residence, and then returned to | | the licensee's office where he found the gauge missing from the back of the | | pickup truck. The worker reported to the RSO that the chain and lock for | | the gauge was lost the previous day (10/7/02). The licensee stated the | | cause for the loss to be a failure to secure the gauge in the truck. The | | licensee and IDNS personnel re-traced the route twice and did not find the | | gauge. The licensee notified the police departments for the cities of West | | Chicago, Naperville, and Warrenville, IL, NRC Region 3, Troxler, Inc and | | the Illinois Department of Transportation. | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ |Power Reactor |Event Number: 39269 | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ | FACILITY: SAINT LUCIE REGION: 2 |NOTIFICATION DATE: 10/11/2002| | UNIT: [1] [] [] STATE: FL |NOTIFICATION TIME: 11:03[EDT]| | RXTYPE: [1] CE,[2] CE |EVENT DATE: 10/11/2002| +------------------------------------------------+EVENT TIME: 09:25[EDT]| | NRC NOTIFIED BY: JOE HASSLING |LAST UPDATE DATE: 10/11/2002| | HQ OPS OFFICER: JOHN MacKINNON +-----------------------------+ +------------------------------------------------+PERSON ORGANIZATION | |EMERGENCY CLASS: NON EMERGENCY |GEORGE MacDONALD | |10 CFR SECTION: | | |NINF INFORMATION ONLY | | | | | | | | | | | +-----+----------+-------+--------+-----------------+--------+-----------------+ |UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE | +-----+----------+-------+--------+-----------------+--------+-----------------+ |1 N Y 0 Refueling |0 Refueling | | | | | | | +------------------------------------------------------------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | CHLORINE RELEASE IN TURBINE GENERATOR BUILDING | | | | "At 0925 EDT, a release of chlorine gas was noted from the hypochlorite | | area, and smell of chlorine gas was noted in the Turbine Generator Building. | | All personnel were evacuated from the Turbine Generator Building as a | | precautionary measure, and personnel were dispatched to determine the | | concentration of chlorine gas. | | | | "All the site of the source, chlorine gas concentration was 3ppm. Per the | | MSDS, the IDLH limit is 30 ppm. No Emergency Action Levels were entered. | | Additional samples are being taken in the Turbine Generator building prior | | to allowing unrestricted access into the area. Both Unit's Control Rooms | | were placed in the recirculation mode as a precautionary measure as well. | | | | "There were no injuries from this event. | | | | "The leak has been stopped." | | | | The chlorine gas was generated while acid cleaning the hypochlorite lines | | with muriatic acid. The acid caused the chlorine to come out as a gas. The | | lines are cleaned periodically to remove the calcium buildup on the lines. | | The licensee is investigating why chlorine gas was released this time when | | it was not released when the lines were cleaned in the past. The licensee | | surmised that they may have used a stronger concentration of muriatic acid | | this time. | | | | The NRC Resident Inspector was notified of this information call by the | | licensee. | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ |Other Nuclear Material |Event Number: 39270 | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ | REP ORG: US DEPT OF AGRICULTURE |NOTIFICATION DATE: 10/11/2002| |LICENSEE: US DEPT OF AGRICULTURE |NOTIFICATION TIME: 14:15[EDT]| | CITY: BELTSVILLE REGION: 1 |EVENT DATE: 10/02/2002| | COUNTY: STATE: MD |EVENT TIME: [EDT]| |LICENSE#: 1900915-03 AGREEMENT: Y |LAST UPDATE DATE: 10/11/2002| | DOCKET: |+----------------------------+ | |PERSON ORGANIZATION | | |JOHN WHITE R1 | | |FRED BROWN NMSS | +------------------------------------------------+ | | NRC NOTIFIED BY: DANIEL SHARP | | | HQ OPS OFFICER: MIKE RIPLEY | | +------------------------------------------------+ | |EMERGENCY CLASS: NON EMERGENCY | | |10 CFR SECTION: | | |BLO1 20.2201(a)(1)(i) LOST/STOLEN LNM>1000X | | | | | | | | | | | | | | +------------------------------------------------------------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | TROXLER GAUGE MISSING WHILE IN SHIPMENT | | | | On 10/10/2002, the licensee received notification from FedEx that their | | Troxler Gauge (Model No. 3321, Serial No. 446 with 10 millicuries Americium | | 241) could not be located. The gauge was being shipped via FedEx from | | Colorado on 10/2/2002 for arrival in California on 10/4/2002. FedEx stated | | that the last confirmed location was in FedEx's Denver facility, but did not | | know exactly when it was lost. FedEx stated that the shipping container | | handle with attached shipping papers had come loose from the container and | | was found on their conveyor belt, but not the container itself. FedEx is | | continuing to locate the gauge. The licensee has not made any other | | notifications. | | | | Contacted R1 DO (John White) and NMSS (Fred Brown) | | | | * * * UPDATE ON 10/11/02 AT 1608 EDT FROM DANIEL SHARP TO MIKE RIPLEY * * * | | | | Mr. Sharp reported that the missing Troxler gauge was located by the | | shipper, Fed Ex , in Memphis, TN. Fed Ex will resend the gauge to the | | intended recipient. | | | | Notified R1DO (John White) and NMSS (John Hickey) | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ |Hospital |Event Number: 39271 | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ | REP ORG: QUEENS MEDICAL CENTER |NOTIFICATION DATE: 10/11/2002| |LICENSEE: QUEENS MEDICAL CENTER |NOTIFICATION TIME: 16:32[EDT]| | CITY: HONOLULU REGION: 4 |EVENT DATE: 10/09/2002| | COUNTY: HONOLULU STATE: HI |EVENT TIME: 13:00[HST]| |LICENSE#: 53-16533-02 AGREEMENT: N |LAST UPDATE DATE: 10/11/2002| | DOCKET: |+----------------------------+ | |PERSON ORGANIZATION | | |KRISS KENNEDY R4 | | |JOHN HICKEY NMSS | +------------------------------------------------+ | | NRC NOTIFIED BY: SCOTT DUBE | | | HQ OPS OFFICER: GERRY WAIG | | +------------------------------------------------+ | |EMERGENCY CLASS: NON EMERGENCY | | |10 CFR SECTION: | | |LADM 35.33 MED MISADMINISTRATION | | | | | | | | | | | | | | +------------------------------------------------------------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | MEDICAL MISADMINISTRATION: BRACHYTHERAPY UNDERDOSE TO TREATMENT SITE | | | | A patient undergoing brachytherapy treatment for cardiac restenosis received | | an underdose when it was determined that the strontium 90 source did not | | reach the intended treatment site. The source contained 16 source beads in | | the source train. The cause of the under dose is suspected to have been | | caused by blockage along the catheter but this has not yet been confirmed. | | An investigation will be conducted to determine the cause of the underdose. | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ |General Information or Other |Event Number: 39272 | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ | REP ORG: C&D TECHNOLOGIES, INC. |NOTIFICATION DATE: 10/11/2002| |LICENSEE: C&D TECHNOLOGIES, INC. |NOTIFICATION TIME: 17:15[EDT]| | CITY: BLUE BELL REGION: 1 |EVENT DATE: 10/11/2002| | COUNTY: STATE: PA |EVENT TIME: [EDT]| |LICENSE#: AGREEMENT: N |LAST UPDATE DATE: 10/11/2002| | DOCKET: |+----------------------------+ | |PERSON ORGANIZATION | | |JOHN MADERA R3 | | |WILLIAM BECKNER NRR | +------------------------------------------------+ | | NRC NOTIFIED BY: TERRY KANDEN | | | HQ OPS OFFICER: GERRY WAIG | | +------------------------------------------------+ | |EMERGENCY CLASS: NON EMERGENCY | | |10 CFR SECTION: | | |CCCC 21.21 UNSPECIFIED PARAGRAPH | | | | | | | | | | | | | | +------------------------------------------------------------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | PART 21 DEFECT/NONCOMPLIANCE IDENTIFIED IN NOT-YET-INSTALLED BATTERY RACKS | | AT PRAIRIE ISLAND | | | | "In accordance with NSP's purchase order requirements and 10CFR21, I am | | notifying you that C&D Technologies, Inc. has identified what it believes to | | be a reportable event. | | | | "On purchase order #534, line item 4, an order was placed for two (2) Single | | Tier racks Part No RD00-900-16EP3. Subsequent to the fabrication of these | | racks it was observed that a series of welds which join the horizontal cross | | beam to the vertical member of the frame were not welded correctly. This may | | affect the seismic qualification of the rack. Our understanding is that | | these racks have not been installed. C&D is making arrangements to replace | | the nonconforming frames prior to the facility's scheduled outage. | | | | "Copies of each of the following referenced drawings were supplied to [the | | licensee] on 10/10/02; the single tier racks (RD00900- 16 EP3) are covered | | by the following drawings; | | | | "M121 14 (1) and (2) are page one and two of the same drawing. These are the | | outline drawings for the rack. Page 1 covers the Bill of Material and shows | | the RD02008E frame is used in rack assembly. | | | | "Ml 104 is the frame drawing for part number RD02008E. The critical part of | | the drawing in our discussion is the gusset support labeled Part No. RE-263 | | 1 (Dwg K-7406). | | | | "Drawing M6228 (1) and (2) reflect the welding details for the racks. | | | | "Detail A on page 1 shows the flare bevel groove weld that is carried across | | the length of the horizontal cross bar as it is welded to the vertical | | member of the frame. This should be carried the full distance of the | | intersection. | | | | "Detail J on page 2 shows the addition of the gusset to reinforce the joint. | | This is placed over the flare bevel groove weld above and then fillet welded | | in place. | | | | "We have been advised that when our sub-tier supplier, Kim Manufacturing, | | manufactured the frames, they preassembled and clamped the vertical member, | | horizontal cross member and gusset in place. They performed a flare bevel | | groove weld on the exposed portion of the horizontal cross member, and | | fillet welded the remaining sections of the cross member and the gusset. The | | portion of the cross member which was hidden behind the gusset was not | | welded with the flare bevel groove weld as it should have been. | | | | "These racks represented the first two racks manufactured by Kim | | Manufacturing after transfer of this manufacturing function to Kim from | | C&D's Conshohocken facility. To ensure that the problem did not predate | | C&D's relationship with Kim we have interviewed the welder responsible for | | this function within Conshohocken and determined that he was aware of the | | requirement for a full flare bevel groove weld prior to the assembly of the | | gusset plate. The welder reports that this was standard practice in | | Conshohocken. No other racks will be affected by this defect. | | | | "Kim Manufacturing first notified C&D of the defect in the welds on the | | afternoon of 10/8/02. After analysis by C&D's engineering department on | | Wednesday (10/9/02) we determined that we no longer had design traceability | | to the original seismic qualification of this rack and that this event | | should be reported. Initial contact was made with NMC Quality Assurance | | through [a licensee representative] on (10/10/02)." | | | | The affected facility is the NMC Prairie Island Station. | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ |Power Reactor |Event Number: 39274 | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ | FACILITY: CALLAWAY REGION: 4 |NOTIFICATION DATE: 10/11/2002| | UNIT: [1] [] [] STATE: MO |NOTIFICATION TIME: 19:29[EDT]| | RXTYPE: [1] W-4-LP |EVENT DATE: 10/11/2002| +------------------------------------------------+EVENT TIME: 14:45[CDT]| | NRC NOTIFIED BY: JOHN DAMPF |LAST UPDATE DATE: 10/11/2002| | HQ OPS OFFICER: GERRY WAIG +-----------------------------+ +------------------------------------------------+PERSON ORGANIZATION | |EMERGENCY CLASS: NON EMERGENCY |KRISS KENNEDY R4 | |10 CFR SECTION: | | |APRE 50.72(b)(2)(xi) OFFSITE NOTIFICATION | | | | | | | | | | | +-----+----------+-------+--------+-----------------+--------+-----------------+ |UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE | +-----+----------+-------+--------+-----------------+--------+-----------------+ |1 N Y 100 Power Operation |100 Power Operation | | | | | | | +------------------------------------------------------------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | NOTIFICATION TO OFFSITE AGENCIES DUE TO SULFURIC ACID RELEASE IN EXCESS OF | | LIMITS | | | | "This notification is being made under 10CFR50.72 (b)(2)(xi) for an event | | reportable to another government agency. The EPA National Response Center | | was notified at 1635, the Missouri Department of Natural Resources at 1645 | | and the Local Emergency Planning Commission at 1650 on 10/11/2002 of a | | release of sulfuric acid in excess of the 40CFR302.6 and 40CFR355.40 | | reportable quantities outside the plant boundary. At 0045 on 10/11/2002 a | | failure of the sulfuric acid feed system to the cooling tower basin was | | detected. The failure resulted in the release of 19,000 pounds (1300 | | gallons) of sulfuric acid outside the plant boundary. At 0050 on 10/11/2002 | | cooling tower blowdown was isolated and the release terminated, The total | | duration of the release was 7 hours, 27 minutes." | | | | The licensee notified the NRC Resident Inspector of the event. | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ |Power Reactor |Event Number: 39275 | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ | FACILITY: DRESDEN REGION: 3 |NOTIFICATION DATE: 10/12/2002| | UNIT: [] [2] [] STATE: IL |NOTIFICATION TIME: 07:55[EDT]| | RXTYPE: [1] GE-1,[2] GE-3,[3] GE-3 |EVENT DATE: 10/11/2002| +------------------------------------------------+EVENT TIME: 17:30[CDT]| | NRC NOTIFIED BY: VALHERIA GENGLER |LAST UPDATE DATE: 10/12/2002| | HQ OPS OFFICER: JOHN MacKINNON +-----------------------------+ +------------------------------------------------+PERSON ORGANIZATION | |EMERGENCY CLASS: NON EMERGENCY |JOHN MADERA R3 | |10 CFR SECTION: | | |HFIT 26.73 FITNESS FOR DUTY | | | | | | | | | | | +-----+----------+-------+--------+-----------------+--------+-----------------+ |UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE | +-----+----------+-------+--------+-----------------+--------+-----------------+ | | | |2 N Y 97 Power Operation |97 Power Operation | | | | +------------------------------------------------------------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | FOR-CAUSE TEST FOR ALCOHOL | | | | Contract supervisor while entering the site was given an initial for cause | | test for alcohol followed by a confirmatory test. Person tested positive for | | alcohol on the confirmatory test. The person's access was revoked. | | | | Call the Headquarters Operation Officer for further details. | | | | The NRC Resident Inspector was notified of this event by the licensee. | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ |Power Reactor |Event Number: 39276 | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ | FACILITY: DIABLO CANYON REGION: 4 |NOTIFICATION DATE: 10/12/2002| | UNIT: [1] [2] [] STATE: CA |NOTIFICATION TIME: 08:02[EDT]| | RXTYPE: [1] W-4-LP,[2] W-4-LP |EVENT DATE: 10/12/2002| +------------------------------------------------+EVENT TIME: 01:30[PDT]| | NRC NOTIFIED BY: J. BROWN |LAST UPDATE DATE: 10/12/2002| | HQ OPS OFFICER: JOHN MacKINNON +-----------------------------+ +------------------------------------------------+PERSON ORGANIZATION | |EMERGENCY CLASS: NON EMERGENCY |KRISS KENNEDY R4 | |10 CFR SECTION: | | |DDDD 73.71(b)(1) SAFEGUARDS REPORTS | | | | | | | | | | | +-----+----------+-------+--------+-----------------+--------+-----------------+ |UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE | +-----+----------+-------+--------+-----------------+--------+-----------------+ |1 N Y 54 Power Operation |54 Power Operation | |2 N Y 100 Power Operation |100 Power Operation | | | | +------------------------------------------------------------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | ALLEGED FITNESS-FOR-DUTY QUESTIONED DUE TO SLEEPING ON WATCH. | | | | IMMEDIATE COMPENSATORY MEASURES TAKEN UPON DISCOVERY. | | | | THE LICENSEE NOTIFIED THE NRC RESIDENT INSPECTOR . | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ |Power Reactor |Event Number: 39277 | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ | FACILITY: OYSTER CREEK REGION: 1 |NOTIFICATION DATE: 10/12/2002| | UNIT: [1] [] [] STATE: NJ |NOTIFICATION TIME: 17:15[EDT]| | RXTYPE: [1] GE-2 |EVENT DATE: 10/12/2002| +------------------------------------------------+EVENT TIME: 16:00[EDT]| | NRC NOTIFIED BY: DAVID PIETRUSKI |LAST UPDATE DATE: 10/12/2002| | HQ OPS OFFICER: GERRY WAIG +-----------------------------+ +------------------------------------------------+PERSON ORGANIZATION | |EMERGENCY CLASS: NON EMERGENCY |JOHN WHITE R1 | |10 CFR SECTION: | | |APRE 50.72(b)(2)(xi) OFFSITE NOTIFICATION | | | | | | | | | | | +-----+----------+-------+--------+-----------------+--------+-----------------+ |UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE | +-----+----------+-------+--------+-----------------+--------+-----------------+ |1 N N 0 Refueling |0 Refueling | | | | | | | +------------------------------------------------------------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | SPURIOUS ACTUATION OF ONE (1) OFFSITE EMERGENCY NOTIFICATION SIREN | | | | The licensee was notified by local police, Lacey Township, NJ, that one (1) | | of the emergency notification sirens was sounding. The licensee confirmed | | the actuation and notified the Ocean County Sheriffs Office, who control the | | siren, and had them turn off the siren. The licensee has dispatched | | communications technicians to investigate the cause of the spurious | | actuation. | | | | The licensee notified the NRC Resident Inspector of the event. | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ |Fuel Cycle Facility |Event Number: 39278 | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ | FACILITY: PORTSMOUTH GASEOUS DIFFUSION PLANT |NOTIFICATION DATE: 10/12/2002| | RXTYPE: URANIUM ENRICHMENT FACILITY |NOTIFICATION TIME: 21:41[EDT]| | COMMENTS: 2 DEMOCRACY CENTER |EVENT DATE: 10/12/2002| | 6903 ROCKLEDGE DRIVE |EVENT TIME: 04:45[EDT]| | BETHESDA, MD 20817 (301)564-3200 |LAST UPDATE DATE: 10/12/2002| | CITY: PIKETON REGION: 3 +-----------------------------+ | COUNTY: PIKE STATE: OH |PERSON ORGANIZATION | |LICENSE#: GDP-2 AGREEMENT: N |JOHN MADERA R3 | | DOCKET: 0707002 |JOHN HICKEY NMSS | +------------------------------------------------+ | | NRC NOTIFIED BY: RICK LARSON | | | HQ OPS OFFICER: GERRY WAIG | | +------------------------------------------------+ | |EMERGENCY CLASS: NON EMERGENCY | | |10 CFR SECTION: | | |NONR OTHER UNSPEC REQMNT | | | | | | | | | | | | | | +------------------------------------------------------------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | VALID (MANUAL) ACTUATION OF A SAFETY SYSTEM | | | | "October 12, 2002, at 0445 hours while performing UF6 sampling (Mode III), | | X-344 Feed and Transfer Building | | Operations personnel manually activated the X-344A Pigtail Line Isolation | | System (a Safety System) this was in | | response to an observed out-gassing from Autoclave #2 Sample Manifold. | | Operations were secured, and personnel | | evacuated the building per procedure. Emergency response personnel monitored | | the area for surface and airborne | | contamination with all samples less than detectable. Autoclave #2 was | | declared inoperable. This event is being | | reported as a valid actuation of a Safety System per [procedure] | | UE2-RA-RE1030, Appendix D, Section J.2." | | | | The licensee notified the NRC Resident Inspector of the event via voice mail | | and the DOE. | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ |Power Reactor |Event Number: 39279 | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ | FACILITY: PEACH BOTTOM REGION: 1 |NOTIFICATION DATE: 10/12/2002| | UNIT: [2] [3] [] STATE: PA |NOTIFICATION TIME: 23:24[EDT]| | RXTYPE: [2] GE-4,[3] GE-4 |EVENT DATE: 10/12/2002| +------------------------------------------------+EVENT TIME: 21:14[EDT]| | NRC NOTIFIED BY: ROBERT BIRMINGHAM |LAST UPDATE DATE: 10/12/2002| | HQ OPS OFFICER: GERRY WAIG +-----------------------------+ +------------------------------------------------+PERSON ORGANIZATION | |EMERGENCY CLASS: NON EMERGENCY |JOHN WHITE R1 | |10 CFR SECTION: | | |APRE 50.72(b)(2)(xi) OFFSITE NOTIFICATION | | | | | | | | | | | +-----+----------+-------+--------+-----------------+--------+-----------------+ |UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE | +-----+----------+-------+--------+-----------------+--------+-----------------+ |2 N Y 99 Power Operation |99 Power Operation | |3 N Y 100 Power Operation |100 Power Operation | | | | +------------------------------------------------------------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | NOTIFICATION OF OFFSITE AUTHORITIES OF FIRE IN 500 KV SWITCHYARD | | | | The licensee notified offsite state and county authorities of a fire in the | | south 500 KV substation. The fire occurred at 2030 on the #205 circuit | | breaker current transformer during electrical switching. The state and | | county were notified of an event of public interest due to multiple | | emergency vehicles responding to the substation. The fire was extinguished | | at 2120. The #205 circuit breaker remains out of service. The circuit | | breaker is on one of two ring buses, on the output side of the main | | generators, and are located about one-half mile from the plant outside the | | protected area. Plant electrical systems, including safety systems, were | | unaffected by the fire in the switchyard. | | | | The licensee notified the NRC Resident Inspector of the event. | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ |Power Reactor |Event Number: 39280 | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ | FACILITY: SAINT LUCIE REGION: 2 |NOTIFICATION DATE: 10/13/2002| | UNIT: [1] [] [] STATE: FL |NOTIFICATION TIME: 12:56[EDT]| | RXTYPE: [1] CE,[2] CE |EVENT DATE: 10/13/2002| +------------------------------------------------+EVENT TIME: 11:10[EDT]| | NRC NOTIFIED BY: KELLY KORTH |LAST UPDATE DATE: 10/13/2002| | HQ OPS OFFICER: GERRY WAIG +-----------------------------+ +------------------------------------------------+PERSON ORGANIZATION | |EMERGENCY CLASS: NON EMERGENCY |GEORGE MacDONALD | |10 CFR SECTION: |WILLIAM BECKNER NRR | |APRE 50.72(b)(2)(xi) OFFSITE NOTIFICATION | | | | | | | | | | | +-----+----------+-------+--------+-----------------+--------+-----------------+ |UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE | +-----+----------+-------+--------+-----------------+--------+-----------------+ |1 N N 0 Refueling |0 Refueling | | | | | | | +------------------------------------------------------------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | OFFSITE NOTIFICATION DUE TO THE DISCOVERY OF CONTAMINATED CLOTHING IN | | UNRESTRICTED AREA | | | | "At 1130 EDT on October 13, 2002, Florida Power and Light made an | | informational notification to the State of Florida (Department of Health, | | Bureau of Radiation Control) regarding the discovery of contaminated | | clothing in an unrestricted area. | | | | "On October 12, 2002 at 1915 EDT, Health Physics personnel identified low | | level fixed contamination on an individual's undergarment in his hotel room. | | The undergarment was confiscated. Measured activity was 20,000 | | disintegrations per minute consisting primarily of Cobalt 58, Cobalt 60 and | | Chromium 51. This resulted in a shallow dose equivalent of 0.0014 rem per | | hour averaged over a 10-centimeter square. Conservatively assuming 16 hours | | of exposure results in 0.022 rem, a very small fraction of the 50-rem annual | | shallow dose regulatory limit. No detectable activity was found on any other | | item during a complete survey of the hotel room and its contents. | | | | "This notification is being made pursuant to 10CFR50.72(b)(2)(xi) in that | | other government agencies have been notified of an event related to the | | health and safety of the public or on-site personnel." | | | | The licensee notified the NRC Resident Inspector of this event. | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ |General Information or Other |Event Number: 39281 | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ | REP ORG: IDAHO DEPT OF ENVIRONMENTAL QUALITY |NOTIFICATION DATE: 10/13/2002| |LICENSEE: |NOTIFICATION TIME: 14:40[EDT]| | CITY: LAVA HOT SPRINGS REGION: 4 |EVENT DATE: 10/13/2002| | COUNTY: BANNOCK STATE: ID |EVENT TIME: 10:30[MDT]| |LICENSE#: AGREEMENT: N |LAST UPDATE DATE: 10/13/2002| | DOCKET: |+----------------------------+ | |PERSON ORGANIZATION | | |KRISS KENNEDY R4 | | |JOHN HICKEY NMSS | +------------------------------------------------+ | | NRC NOTIFIED BY: DOUG WALKER | | | HQ OPS OFFICER: GERRY WAIG | | +------------------------------------------------+ | |EMERGENCY CLASS: NON EMERGENCY | | |10 CFR SECTION: | | |BLO1 20.2201(a)(1)(i) LOST/STOLEN LNM>1000X | | | | | | | | | | | | | | +------------------------------------------------------------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | TWO MOISTURE DENSITY GAUGES FOUND IN IDAHO RIVER | | | | Two local citizens found two Troxler moisture density gauges in the | | Portneous River located near Lava Hot Springs, Idaho, in Bannock County. The | | citizens, seeing the trifoil radiation symbol on one of the gauges, | | immediately contacted the Bannock County Sheriffs Office. The Sheriff's | | Office called the State of Idaho and two hazardous material qualified State | | Police Officers were dispatched to the scene. On-scene inspection of the two | | gauges by the Idaho Dept. of Environmental Quality Radiation Safety Officer | | revealed that one of the gauges is Model 2401, serial #2813. The Model | | number on the second gauge is not readable but both appeared to be same | | model. The serial number of the second gauge is 2744. Additional information | | found on the gauges indicated that they are 8.2 millicurie Cs-137, 50 | | millicurie Am-241:Be sources. A survey of the gauges indicated a 13 | | millirem/hour contact reading and less than 2 times background smear survey. | | The sources will be transported to a secure location for storage until the | | owner(s) can be located and the gauges returned. Local law enforcement will | | continue to investigate the circumstances of the recovered gauges. | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ |Transportation |Event Number: 39282 | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ | REP ORG: MICHIGAN DEPARTMENT OF ENVIR. QUAL |NOTIFICATION DATE: 10/14/2002| |LICENSEE: SYNCOR |NOTIFICATION TIME: 09:58[EDT]| | CITY: HESPERIA REGION: 3 |EVENT DATE: 10/14/2002| | COUNTY: OCEANA STATE: MI |EVENT TIME: 07:00[EDT]| |LICENSE#: 04-26507-01MD AGREEMENT: N |LAST UPDATE DATE: 10/14/2002| | DOCKET: |+----------------------------+ | |PERSON ORGANIZATION | | |JOHN MADERA R3 | | |JOHN HICKEY NMSS | +------------------------------------------------+NOWAK DOT | | NRC NOTIFIED BY: D. MINNAAR |STUART BAILEY DOE | | HQ OPS OFFICER: JOHN MacKINNON |NADER MAMISH IRO | +------------------------------------------------+ | |EMERGENCY CLASS: | | |10 CFR SECTION: | | |NINF INFORMATION ONLY | | | | | | | | | | | | | | +------------------------------------------------------------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | SYNCOR VEHICLE CARRYING RADIOPHARMACEUTICALS OVERTURNED | | | | A Syncor transportation vehicle, 2000 Ford Ranger Pickup truck, turned over | | near State Highway M-20 and 162 avenue which is located in Oceana County, MI | | west of Hesperia, MI, around 0700 ET on October 14, 2002. The driver was not | | injured. Three packages were damaged or potentially damaged. The first | | package was empty and was being returned to Syncor was totally smashed. The | | second package had a White Label 1 containing 16.13 GBq of Tc-99m. The third | | package was Yellow Label 2 contain 6.9GBq of Tc-99m and 0.001 GBq of I-123. | | The last two packages were being delivered to Gerber Memorial Health Center | | located in Fremont, MI. When the local Fire Department/Police showed up at | | the scene of the accident they called Gerber Memorial Health Center and | | informed them that they needed someone to take radiation surveys at the | | scene of the accident. Gerber Memorial Health Center sent a person to the | | scene of the accident. All radiological surveys taken at the scene of the | | accident indicated that the contents of packages 2 & 3 were not damaged. | | The inner containers inside packages 2 & 3 were intact and undamaged. The | | first package level was at normal background level. The person from Gerber | | Memorial Health Center placed the packages in the trunk of his car and took | | them to Gerber Memorial Health Center. Syncor went out to Gerber Memorial | | Health Center and picked up the packages and took them to their facility | | located in Jenison, MI. Also Syncor took radiation surveys at the scene of | | the accident and all radiation readings were normal. | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ |Power Reactor |Event Number: 39283 | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ | FACILITY: OYSTER CREEK REGION: 1 |NOTIFICATION DATE: 10/14/2002| | UNIT: [1] [] [] STATE: NJ |NOTIFICATION TIME: 14:40[EDT]| | RXTYPE: [1] GE-2 |EVENT DATE: 10/14/2002| +------------------------------------------------+EVENT TIME: 14:15[EDT]| | NRC NOTIFIED BY: DAVE PIETRUSKI |LAST UPDATE DATE: 10/14/2002| | HQ OPS OFFICER: STEVE SANDIN +-----------------------------+ +------------------------------------------------+PERSON ORGANIZATION | |EMERGENCY CLASS: NON EMERGENCY |JOHN WHITE R1 | |10 CFR SECTION: | | |AUNA 50.72(b)(3)(ii)(B) UNANALYZED CONDITION | | | | | | | | | | | +-----+----------+-------+--------+-----------------+--------+-----------------+ |UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE | +-----+----------+-------+--------+-----------------+--------+-----------------+ |1 N N 0 Refueling |0 Refueling | | | | | | | +------------------------------------------------------------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | DISCOVERY THAT APPENDIX R CRITERIA NOT SATISFIED FOR ELECTRICAL CABLING | | | | "An open void was discovered (approx. 5 feet deep) that exists in the area | | between the Reactor and Turbine Building walls beneath the 23' floor elev. | | affecting Appendix R fire separation. It appears that sand has been moved / | | eroded away over time, thus opening a void beneath the A and B 480 V switch | | gear room floors. Adequate separation of the conduits between A and B trains | | no longer meets Appendix R separation criteria beneath the floor. | | | | "At the present time plant safety is not affected, as a compensatory measure | | a firewatch has been established in the affected area." | | | | The licensee has corrective action under review and has informed the NRC | | resident inspector. | +------------------------------------------------------------------------------+
Page Last Reviewed/Updated Thursday, March 25, 2021
Page Last Reviewed/Updated Thursday, March 25, 2021