Skip to main content

Event Notification Report for May 28, 2002

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
05/27/2002 - 05/28/2002

EVENT NUMBERS
3894738976

Power Reactor
Event Number: 38947
Facility: SEABROOK
Region: 1     State: NH
Unit: [1] [] []
RX Type: [1] W-4-LP
NRC Notified By: STEPHEN MORRISSEY
HQ OPS Officer: FANGIE JONES
Notification Date: 05/28/2002
Notification Time: 09:38 [ET]
Event Date: 05/28/2002
Event Time: 02:31 [EDT]
Last Update Date: 05/28/2002
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(3)(iv)(A) - VALID SPECIF SYS ACTUATION
Person (Organization):
JOHN ROGGE (R1)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N N 0 Hot Shutdown 0 Hot Shutdown
Event Text
DIGITAL ROD POSITION URGENT FAILURE DURING TESTING

While performing rod withdrawal testing in Mode 4, a digital rod position indication (DRPI) "Urgent Failure " alarm was received for rod L-5 in control bank 'A' at the 72 step position. Control bank 'A' was the only bank withdrawn at the time. The reactor trip breakers were opened and all rods fully inserted in accordance with Tech Spec 3.1.3.3. The cause of the failure was a card failure, which has been repaired.

The licensee notified the NRC Resident Inspector.


Other Nuclear Material
Event Number: 38976
Rep Org: STATE OF MONTANA - RSO
Licensee: ROCKY MOUNTAIN LABRATORIES
Region: 4
City: HAMILTON   State: MT
County:
License #: 25-01202-01
Agreement: N
Docket:
NRC Notified By: DIANNE HUHTANEN
HQ OPS Officer: RICH LAURA
Notification Date: 06/10/2002
Notification Time: 16:04 [ET]
Event Date: 05/28/2002
Event Time: 08:30 [MDT]
Last Update Date: 05/28/2002
Emergency Class: NON EMERGENCY
10 CFR Section:
20.2201(a)(1)(i) - LOST/STOLEN LNM>1000X
Person (Organization):
ANTHONY GODY (R4)
FRED BROWN (NMSS)
Event Text
LOST/MISSING RADIOACTIVE MATERIAL AT ROCKY MOUNTAIN LABS

The Montana State RSO reported that Rocky Mountain Laboratories located in Hamilton, Montana is missing approximately 12 millicuries of Sulfur-35. This material is a low energy beta emitter which is used for biological research including protein mapping. The material was in the form of pellets and was in the bottom of microfuge tubes which were wrapped in a double bag. The bag was last seen in building 1, room 102, on May 24, 2002 at 17:00. The material was discovered missing at 8:00 am on May 28, 2002. A search was conducted and also waste streams were checked.

The State of Montana notified the NRC Region IV (Christy Maier).