Due to a lapse in appropriations, the NRC has ceased normal operations. However, excepted and exempted activities necessary to maintain critical health and safety functions—as well as essential progress on designated critical activities, including those specified in Executive Order 14300—will continue, consistent with the OMB-Approved NRC Lapse Plan.

Event Notification Report for May 28, 2002

                         
                    U.S. Nuclear Regulatory Commission
                              Operations Center

                              Event Reports For
                           05/24/2002 - 05/28/2002

                              ** EVENT NUMBERS **

38634  38809  38935  38941  38942  38943  38945  38946  

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   38634       |
+------------------------------------------------------------------------------+
                         
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: SAINT LUCIE              REGION:  2  |NOTIFICATION DATE: 01/17/2002|
|    UNIT:  [1] [2] []                STATE:  FL |NOTIFICATION TIME: 13:07[EST]|
|   RXTYPE: [1] CE,[2] CE                        |EVENT DATE:        01/17/2002|
+------------------------------------------------+EVENT TIME:        11:45[EST]|
| NRC NOTIFIED BY:  KELLY KORTH                  |LAST UPDATE DATE:  05/27/2002|
|  HQ OPS OFFICER:  CHAUNCEY GOULD               +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          NON EMERGENCY         |ROBERT HAAG          R2      |
|10 CFR SECTION:                                 |                             |
|APRE 50.72(b)(2)(xi)     OFFSITE NOTIFICATION   |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE  
|
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          Y       100      Power Operation  |100      Power Operation  |
|2     N          Y       100      Power Operation  |100      Power Operation  |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| OFFSITE NOTIFICATION  INVOLVING RECOVERED SEA TURTLE FROM INTAKE CANAL    
  |
|                                                                              |
| At approximately 1130 EST on 01/17/02, a green sea turtle was retrieved from |
| the intake canal and a determination was made that it was in need of         |
| rehabilitation.  As required by the Plant's Sea Turtle Permit, the Florida   |
| Fish and Wildlife Conservation Commission (FFWCC) was notified at 1145 EST.  |
|                                                                              |
| The licensee notified the NRC Resident Inspector.                            |
|                                                                              |
| See EN #38513 for 2001 occurrences.                                          |
|                                                                              |
| * * * UPDATE ON 1/28/02  @ 1243 BY KORTH TO GOULD * * *                      |
|                                                                              |
| At approximately 1115 on 1/28/02 a loggerhead turtle was retrieved from the  |
| plant's  intake canal.  The turtle was determined to be in need of           |
| rehabilitation.  Per the licensee's turtle permit, the Florida Fish and      |
| Wildlife Conservation Commission (FWCC) was notified at 1125.                |
|                                                                              |
| The NRC Resident Inspector was notified.   Notified Reg 2 RDO (Ninh)         |
|                                                                              |
| * * * UPDATE ON 2/6/02 @ 0853 BY MERRILL TO GOULD * * *                      |
|                                                                              |
| At approximately 0745 on 2/6/02 an injured green sea turtle was rescued from |
| the plant's intake canal.  The turtle was alive, but in need of              |
| rehabilitation.  The turtle will be transported to a facility in Clearwater  |
| for treatment.  The Florida Department of Environmental Protection has been  |
| notified of the event.                                                       |
|                                                                              |
| The NRC Resident Inspector was notified.                                     |
|                                                                              |
| Notified Reg 2 RDO(Fredrickson)                                              |
|                                                                              |
| * * * UPDATE 1025 3/2/2002 BY R. DIEHL TAKEN BY R. STRANSKY * * *            |
|                                                                              |
| "At approximately 0830 3/2/02 a Loggerhead turtle was retrieved from the     |
| plant's intake canal. The turtle was determined to be in need of             |
| rehabilitation. Per the plant's turtle permit, the Florida Fish and Wildlife |
| Conservation Commission (FWCC) was notified at 0845."                        |
|                                                                              |
| The NRC resident inspector has been informed of this report. HOO notified    |
| R2DO (Julian).                                                               |
|                                                                              |
| * * * UPDATE 1040EST ON 3/5/02 FROM GEORGE TULLIDGE TO S. SANDIN * * *       |
|                                                                              |
| "At Approximately 1000 on 3/5/02, a Loggerhead turtle was retrieved from the |
| plant intake canal.  The turtle was determined to be in need of              |
| rehabilitation.  Per the plant's turtle permit, the Florida Fish and         |
| Wildlife Conservation Commission (FWCC) was notified."                       |
|                                                                              |
| The NRC resident inspector has been informed of this report. HOO notified    |
| R2DO (Julian).                                                               |
|                                                                              |
| * * * UPDATE 1047EST ON 3/6/02 FROM D. EMLING TO M.NORRIS * * *              |
|                                                                              |
| "At Approximately 1000 on 3/6/02, a Loggerhead turtle was retrieved from the |
| plant intake canal.  The turtle was determined to be in need of              |
| rehabilitation.  Per the plant's turtle permit, the Florida Fish and         |
| Wildlife Conservation Commission (FWCC) was notified."                       |
|                                                                              |
| The NRC resident inspector has been informed of this report. HOO notified    |
| R2DO (Henson).                                                               |
|                                                                              |
| * * * UPDATE ON 3/10/02 @ 1740 BY KORTH TO GOULD * * *                       |
|                                                                              |
| The Florida Department of Environmental protection was notified of a         |
| loggerhead sea turtle requiring off-site rehabilitation.  The turtle was     |
| recovered live from the plant's intake canal.                                |
|                                                                              |
| The NRC Resident Inspector was notified.                                     |
|                                                                              |
| Notified Reg @ RDO (Henson)                                                  |
|                                                                              |
| * * * UPDATE ON 5/27/02 AT 1012 BY RUSSELL SCOT TO FANGIE JONES * * *        |
|                                                                              |
| The Florida Department of Environmental protection was notified of a sick    |
| underweight loggerhead sea turtle requiring off-site rehabilitation.  The    |
| turtle was recovered live from the plant's intake canal at 0915 EST on       |
| 5/27/02.                                                                     |
|                                                                              |
| The NRC Resident Inspector will be notified.                                 |
|                                                                              |
| Notified R2DO (Thomas Decker).                                               |
|                                                                              |
| * * * UPDATE AT 1938EDT ON 5/27/02 FROM ELLIOT SUMNER TO S. SANDIN * * *     |
|                                                                              |
| "A dead Sea Turtle was recovered from the St. Lucie Plant Intake Canal at    |
| approx. 1600 [on] 05/27/02.  The FL. Dept. of Envir. Protection was notified |
| (1615 [on] 05/27/02) as required by the St. Lucie Plant - Sea Turtle Permit. |
| This notification to a state government agency requires a four (4) hr        |
| non-emergency notification to the NRC per 10 CFR 50.72(b)(2)(xi).  There     |
| were no unusual evolutions in progress beyond normal operations which would  |
| have contributed to this event."                                             |
|                                                                              |
| The NRC Resident Inspector will be informed.                                 |
|                                                                              |
| Notified R2DO(Decker).                                                       |
+------------------------------------------------------------------------------+

!!!!!!!!! THIS EVENT HAS BEEN RETRACTED. THIS EVENT HAS BEEN RETRACTED  !!!!!!!
+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   38809       |
+------------------------------------------------------------------------------+
                         
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: DRESDEN                  REGION:  3  |NOTIFICATION DATE: 03/28/2002|
|    UNIT:  [] [2] [3]                STATE:  IL |NOTIFICATION TIME: 01:24[EST]|
|   RXTYPE: [1] GE-1,[2] GE-3,[3] GE-3           |EVENT DATE:        03/27/2002|
+------------------------------------------------+EVENT TIME:        22:30[CST]|
| NRC NOTIFIED BY:  BROCK                        |LAST UPDATE DATE:  05/24/2002|
|  HQ OPS OFFICER:  CHAUNCEY GOULD               +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          NON EMERGENCY         |BRUCE BURGESS        R3      |
|10 CFR SECTION:                                 |                             |
|AUNA 50.72(b)(3)(ii)(B)  UNANALYZED CONDITION   |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE  
|
+-----+----------+-------+--------+-----------------+--------+-----------------+
|                                                   |                          |
|2     N          Y       95       Power Operation  |95       Power Operation  |
|3     N          Y       100      Power Operation  |100      Power Operation  |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| SPURIOUS OPERATION OF THE REACTOR HEAD VENT VALVES IN THE SAFE
SHUTDOWN      |
| REPORT(SSR) IS NOT CONSISTENT WITH THE NRC SAFETY EVALUATION REPORT.       
 |
|                                                                              |
| Specifically the Section 3.4.3 of the SER states that spurious operation of  |
| the Reactor Head Vent (RHV) valves {SO-2(3)-0220-46 ann SO-2(3)-0220-47}     |
| which would result in Reactor Coolant inventory loss, will be prevented by a |
| pre-fire action to ensure closure by removing power from these valves.       |
| However, the current SSR dispositions this postulated concern based upon the |
| assumption that spurious operation of greater than one normally closed valve |
| in a series combination is not considered a credible failure mode except for |
| high/low pressure systems.   As a result, there is no pre-fire action to     |
| ensure closure by removing power to RHV valves.  The documentation (FPR      |
| revision and 50.59) that supports the change in the licensing position of    |
| these valves from that described in the SER to the current SSR has not been  |
| located.                                                                     |
|                                                                              |
| A review was performed on the Fire Protection Report (FPR) which includes    |
| the Fire Hazard Analysis & Safe Shutdown Analysis, to evaluate the options   |
| for additional sources of water to address the loss of reactor inventory     |
| from the spurious actions of the reactor head vent valves.  This review      |
| indicated that no specific circuit analysis was performed to determine what  |
| other available sources of water could be used for makeup of reactor         |
| inventory via the reactor head vent valves spurious operation.  Therefore,   |
| in the event of a fire in the various assumed Appendix R fire zones, a       |
| qualified makeup source would not be available to mitigate the inventory     |
| loss introduced by the spurious operation of both RHV valves.                |
|                                                                              |
| Fuses have been pulled to remove power to and close a RHV valve on both Unit |
| 2 and Unit 3 to comply with the SER. The action puts the plant in the        |
| configuration required if the RHV valves are considered a high-low pressure  |
| boundary. Completion of this action restores the plants compliance with the  |
| referenced SER.                                                              |
|                                                                              |
| Dresden Engineering will perform an evaluation that documents the RHV valves |
| as a high-low pressure boundary and that the actions taken above are         |
| adequate to mitigate the multiple spurious failures which must be postulated |
| when these valves are considered a high/low pressure boundary.   A revision  |
| to the FPR will be made to document the results of this evaluation.          |
|                                                                              |
| The NRC Resident Inspector will be notified.                                 |
|                                                                              |
| ***** RETRACTION AT 1815 EDT ON 05/24/02 FROM WARREN DEAGLE TO LEIGH
TROCINE |
| *****                                                                        |
|                                                                              |
| The following text is a portion of a facsimile received from the licensee:   |
|                                                                              |
| "On March 27, 2002 at 2230 CST, Dresden Station made an ENS Notification (EN |
| 38809) regarding fuses that had not been removed from reactor head vent      |
| (RHV) valves.  It was reported that the station's methodology for addressing |
| fire induced spurious operation of the RHV valves in the safe shutdown       |
| report was not consistent with the NRC safety evaluation report.  During     |
| preliminary reviews, it was postulated that a fire could result in spurious  |
| operation of these valves that in turn would result in reactor inventory     |
| loss.  The postulated water source in the scenario was the opposite unit's   |
| Control Rod Drive system, which may not provide the makeup capability to     |
| maintain reactor water level above the top of active fuel (TAF)."            |
|                                                                              |
| "The condition was reported in accordance with 10 CFR 50.72(b)(3)(ii)(B), as |
| an Unanalyzed condition that significantly degraded plant safety."           |
|                                                                              |
| "Upon further evaluation, it has been determined that a credible fire that   |
| would cause spurious operation of the RHV valves would not result in a loss  |
| in the High Pressure Coolant Injection (HPCI) system. Therefore, the HPCI    |
| system would have been available and capable to provide inventory makeup to  |
| the reactor vessel.  Vessel water level would have been maintained above     |
| TAF.  Based on the subsequent evaluation, the safety function (inventory     |
| control) would have been maintained at all times during post-fire safe       |
| shutdown of the unit."                                                       |
|                                                                              |
| "Therefore, based on the above conclusion, this notification is being        |
| retracted."                                                                  |
|                                                                              |
| The licensee notified the NRC resident inspector.  The NRC operations        |
| officer notified the R3DO (Christine Lipa).                                  |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|General Information or Other                     |Event Number:   38935       |
+------------------------------------------------------------------------------+
                         
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG:  TEXAS DEPARTMENT OF HEALTH           |NOTIFICATION DATE: 05/22/2002|
|LICENSEE:  HVJ ASSOCIATES                       |NOTIFICATION TIME: 17:49[EDT]|
|    CITY:  AUSTIN                   REGION:  4  |EVENT DATE:        05/21/2002|
|  COUNTY:                            STATE:  TX |EVENT TIME:        10:00[CDT]|
|LICENSE#:  L03813-003            AGREEMENT:  Y  |LAST UPDATE DATE:  05/22/2002|
|  DOCKET:                                       |+----------------------------+
|                                                |PERSON          ORGANIZATION |
|                                                |LINDA SMITH          R4      |
|                                                |THOMAS ESSIG         NMSS    |
+------------------------------------------------+                             |
| NRC NOTIFIED BY:  HELEN WATKINS                |                             |
|  HQ OPS OFFICER:  JOHN MacKINNON               |                             |
+------------------------------------------------+                             |
|EMERGENCY CLASS:          NON EMERGENCY         |                             |
|10 CFR SECTION:                                 |                             |
|NAGR                     AGREEMENT STATE        |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| STOLEN HUMBOLDT GAUGE CONTAINING CESIUM-137 AND AMERICIUM-241 THAT
WAS LATER |
| RECOVERED                                                                    |
|                                                                              |
|                                                                              |
| On May 21, 2002, a Humboldt 5001EZ gauge was stolen between the hours of     |
| 1000 hours and 1200 hours from a truck parked behind the Licensee's office,  |
| HVJ Associates, Inc. located in Austin.  The gauge was discovered missing at |
| 1230 hours and was later found at 1400 hours.  The gauge was found by        |
| security at a local shopping plaza.  The gauge was secure inside the yellow  |
| container on the ground near a dumpster.  The shielding remained intact and  |
| no one was exposed to the excessive radiation levels. The local police had   |
| been notified of the gauge being stolen.  The serial number for the Humboldt |
| gauge is 3776.  No media attention.                                          |
|                                                                              |
| Texas Incident No. I-7896                                                    |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   38941       |
+------------------------------------------------------------------------------+
                         
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: GINNA                    REGION:  1  |NOTIFICATION DATE: 05/24/2002|
|    UNIT:  [1] [] []                 STATE:  NY |NOTIFICATION TIME: 09:26[EDT]|
|   RXTYPE: [1] W-2-LP                           |EVENT DATE:        05/23/2002|
+------------------------------------------------+EVENT TIME:        14:00[EDT]|
| NRC NOTIFIED BY:  JOE WIDAY                    |LAST UPDATE DATE:  05/24/2002|
|  HQ OPS OFFICER:  MIKE NORRIS                  +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          NON EMERGENCY         |WILLIAM RULAND       R1      |
|10 CFR SECTION:                                 |                             |
|HFIT 26.73               FITNESS FOR DUTY       |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE  
|
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          Y       100      Power Operation  |100      Power Operation  |
|                                                   |                          |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| FITNESS FOR DUTY REPORT                                                      |
|                                                                              |
| A non-licensed contract supervisor was determined to have provided a tainted |
| sample during a random drug test.  The employee's access to the plant has    |
| been terminated.                                                             |
|                                                                              |
| Refer to the Headquarters Operations Officer for additional details.         |
|                                                                              |
| The NRC Resident Inspector has been notified.                                |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   38942       |
+------------------------------------------------------------------------------+
                         
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: SEABROOK                 REGION:  1  |NOTIFICATION DATE: 05/24/2002|
|    UNIT:  [1] [] []                 STATE:  NH |NOTIFICATION TIME: 12:33[EDT]|
|   RXTYPE: [1] W-4-LP                           |EVENT DATE:        05/23/2002|
+------------------------------------------------+EVENT TIME:        19:34[EDT]|
| NRC NOTIFIED BY:  PATRICK RYAN                 |LAST UPDATE DATE:  05/24/2002|
|  HQ OPS OFFICER:  LEIGH TROCINE                +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          NON EMERGENCY         |RONALD BELLAMY       R1      |
|10 CFR SECTION:                                 |                             |
|HFIT 26.73               FITNESS FOR DUTY       |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE  
|
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          N       0        Cold Shutdown    |0        Cold Shutdown    |
|                                                   |                          |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| A CONTRACT SUPERVISOR TESTED POSITIVE FOR ALCOHOL DURING A RANDOM         
  |
| FITNESS-FOR-DUTY TEST (24-Hour Report)                                       |
|                                                                              |
| A contract supervisor failed a random drug and alcohol fitness-for-duty      |
| test.  The individual tested positive for alcohol, and the results of the    |
| drug portion of the test have not yet been received.  The individual's       |
| unescorted site access was terminated at 1937 on 05/23/02, and the licensee  |
| plans to perform a  review of the individual's work for the last 30 calendar |
| days or for the duration of the individual's employment (which ever is       |
| shorter).  (Call the NRC operations officer for additional details.)         |
|                                                                              |
| The licensee notified the NRC resident inspector and plans to notify the NRC |
| Region 1 office (Greg Smith).                                                |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Other Nuclear Material                           |Event Number:   38943       |
+------------------------------------------------------------------------------+
                         
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG:  US ARMY                              |NOTIFICATION DATE: 05/24/2002|
|LICENSEE:  US ARMY                              |NOTIFICATION TIME: 14:39[EDT]|
|    CITY:  ABERDEEN                 REGION:  1  |EVENT DATE:        05/24/2002|
|  COUNTY:                            STATE:  MD |EVENT TIME:        11:30[EDT]|
|LICENSE#:  19-00294-19           AGREEMENT:  Y  |LAST UPDATE DATE:  05/24/2002|
|  DOCKET:                                       |+----------------------------+
|                                                |PERSON          ORGANIZATION |
|                                                |RONALD BELLAMY       R1      |
|                                                |FRED BROWN           NMSS    |
+------------------------------------------------+NADER MAMISH         IRO     |
| NRC NOTIFIED BY:  JOHN BECKMAN                 |                             |
|  HQ OPS OFFICER:  LEIGH TROCINE                |                             |
+------------------------------------------------+                             |
|EMERGENCY CLASS:          NON EMERGENCY         |                             |
|10 CFR SECTION:                                 |                             |
|BAB1 20.2201(a)(1)(i)    LOST/STOLEN LNM>1000X  |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| DISCOVERY OF CONTAMINATION/TRITIUM LEAKAGE ON AN M-1 TANK MUZZLE
REFERENCE   |
| SENSOR AT THE US ARMY ABERDEEN TEST SITE TANK RANGE                          |
|                                                                              |
| While preparing a tank for shipment, the licensee discovered that an M-1     |
| Tank Muzzle Reference Sensor (MRS) containing 10 curies of tritium was       |
| leaking and discharged to the atmosphere.  The exact time that the leak      |
| occurred is not currently known.  Apparently, 200 rounds were fired from     |
| this tank, and then the MRS was checked prior to shipment of the tank to     |
| Michigan.  Three swipe counts were performed, and the contamination levels   |
| ranged between 150,000 and 170,000 dpm/100 cm�.                              |
|                                                                              |
| The licensee stated that there were no personnel contaminations as a result  |
| of this event.  A swipe count was performed on the hands of the individual   |
| who installed the MRS, and it was negative.  Urinalysis is also being        |
| performed as a precautionary measure, and the results are pending.           |
| Apparently, no other personnel came into contact with the leaking MRS.       |
|                                                                              |
| The leaking MRS was removed, double bagged, and placed in storage.  The      |
| licensee plans to dispose of it as radioactive waste.                        |
|                                                                              |
| There was minimal contamination on the tank gun tube, and it was cleaned to  |
| acceptable levels (below limits).  The licensee plans to ship the tank       |
| without the MRS.                                                             |
|                                                                              |
| (Call the NRC operations officer for a contact telephone number for the      |
| licensee's Radiation Safety Officer.)                                        |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   38945       |
+------------------------------------------------------------------------------+
                         
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: CATAWBA                  REGION:  2  |NOTIFICATION DATE: 05/24/2002|
|    UNIT:  [1] [2] []                STATE:  SC |NOTIFICATION TIME: 17:06[EDT]|
|   RXTYPE: [1] W-4-LP,[2] W-4-LP                |EVENT DATE:        05/24/2002|
+------------------------------------------------+EVENT TIME:        14:20[EDT]|
| NRC NOTIFIED BY:  JEFFREY BRADLEY              |LAST UPDATE DATE:  05/24/2002|
|  HQ OPS OFFICER:  LEIGH TROCINE                +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          NON EMERGENCY         |THOMAS DECKER        R2      |
|10 CFR SECTION:                                 |                             |
|APRE 50.72(b)(2)(xi)     OFFSITE NOTIFICATION   |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE  
|
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          Y       100      Power Operation  |100      Power Operation  |
|2     N          Y       100      Power Operation  |100      Power Operation  |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| OFFSITE NOTIFICATION REGARDING THE DISCOVERY OF AN OLD SPENT BLASTING
CAP IN |
| THE YARD OUTSIDE THE PROTECTED AREA                                          |
|                                                                              |
| The following text is a portion of a facsimile received from the licensee:   |
|                                                                              |
| "Offsite agency assistance [was] requested to assess a spent blasting cap    |
| found outside the Protected Area in the yard.  A City of Rock Hill           |
| explosives expert was requested by security to assess/take possession of the |
| spent blasting cap."                                                         |
|                                                                              |
| "The explosives expert determined that the blasting cap was spent[.  The     |
| explosives expert also] determined its age as 10-20 years at least and [that |
| it] was leftover from the construction of the site.  The officer took        |
| possession of the spent blasting cap and removed it from the site at 1507    |
| EDT."                                                                        |
|                                                                              |
| The licensee notified the NRC resident inspector and City of Rock Hill       |
| Police Department in South Carolina.  The licensee also plans to notify the  |
| States of North Carolina and South Carolina as well as York, Gaston, and     |
| Mecklenburg Counties.                                                        |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   38946       |
+------------------------------------------------------------------------------+
                         
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: CATAWBA                  REGION:  2  |NOTIFICATION DATE: 05/26/2002|
|    UNIT:  [1] [] []                 STATE:  SC |NOTIFICATION TIME: 15:24[EDT]|
|   RXTYPE: [1] W-4-LP,[2] W-4-LP                |EVENT DATE:        05/26/2002|
+------------------------------------------------+EVENT TIME:        08:35[EDT]|
| NRC NOTIFIED BY:  BRADLEY                      |LAST UPDATE DATE:  05/26/2002|
|  HQ OPS OFFICER:  CHAUNCEY GOULD               +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          NON EMERGENCY         |THOMAS DECKER        R2      |
|10 CFR SECTION:                                 |                             |
|AIND 50.72(b)(3)(v)(D)   ACCIDENT MITIGATION    |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE  
|
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          Y       100      Power Operation  |100      Power Operation  |
|                                                   |                          |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| PERSONNEL ACCESS DOOR BETWEEN UPPER AND LOWER CONTAINMENT
COMPARTMENTS FOUND |
| OPEN                                                                         |
|                                                                              |
| Maintenance technicians discovered a personnel access door (submarine hatch) |
| open between the upper and lower containment compartments.  The seals and    |
| sealing surfaces were inspected and the door was closed immediately in       |
| compliance with LCO 3.6.14.  While the door was open, containment divider    |
| integrity was not intact per LCO 3.6.14.  This LCO establishes the minimum   |
| equipment requirements to ensure that the divider barrier performs its       |
| safety function of ensuring that bypass leakage, in the event of a DBA, does |
| not exceed the bypass leakage assumed in the accident analysis.  The divider |
| barrier functions with the ice condenser to limit the pressure and           |
| temperature that could be expected following a DBA.                          |
|                                                                              |
| An analysis performed to support a 6 hour completion time in LCO 3.6.14      |
| condition B indicates that an open hatch(7.5 sq. ft bypass area) during a    |
| DBA does not impact the design pressure or temperature of the containment.   |
| The submarine hatch is 2 ft in diameter(3.19 sq. ft), thus the safety        |
| significance is considered minimal at this time.                             |
|                                                                              |
| The NRC Resident Inspector will be notified along with the states of N       |
| Carolina and S Carolina.                                                     |
|                                                                              |
| Also the nearby counties were notified.                                      |
+------------------------------------------------------------------------------+