Skip to main content

Alert

Due to a lapse in appropriations, the NRC has ceased normal operations. However, excepted and exempted activities necessary to maintain critical health and safety functions—as well as essential progress on designated critical activities, including those specified in Executive Order 14300—will continue, consistent with the OMB-Approved NRC Lapse Plan.

Event Notification Report for August 14, 2001

                    U.S. Nuclear Regulatory Commission
                              Operations Center

                              Event Reports For
                           08/13/2001 - 08/14/2001

                              ** EVENT NUMBERS **

38130  38203  38204  38205  38206  

!!!!!!!!! THIS EVENT HAS BEEN RETRACTED. THIS EVENT HAS BEEN RETRACTED  !!!!!!!
+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   38130       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: MONTICELLO               REGION:  3  |NOTIFICATION DATE: 07/11/2001|
|    UNIT:  [1] [] []                 STATE:  MN |NOTIFICATION TIME: 23:01[EDT]|
|   RXTYPE: [1] GE-3                             |EVENT DATE:        07/11/2001|
+------------------------------------------------+EVENT TIME:        16:50[CDT]|
| NRC NOTIFIED BY:  DAVID BARNETT                |LAST UPDATE DATE:  08/13/2001|
|  HQ OPS OFFICER:  FANGIE JONES                 +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          NON EMERGENCY         |DAVID HILLS          R3      |
|10 CFR SECTION:                                 |                             |
|ADEG 50.72(b)(3)(ii)(A)  DEGRADED CONDITION     |                             |
|AINC 50.72(b)(3)(v)(C)   POT UNCNTRL RAD REL    |                             |
|AIND 50.72(b)(3)(v)(D)   ACCIDENT MITIGATION    |                             |
|ASHU 50.72(b)(2)(i)      PLANT S/D REQD BY TS   |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          Y       100      Power Operation  |99       Power Operation  |
|                                                   |                          |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| PRIMARY CONTAINMENT DECLARED INOPERABLE - TECH SPEC REQUIRED SHUTDOWN        |
|                                                                              |
| The licensee found a shipping restraint installed on a drywell-to-torus vent |
| pipe bellows, apparently in place since construction (about 30 years).  This |
| device was discovered due to another licensee with similar containment       |
| configuration notifying Monticello of their discovery.  This device would    |
| partially impede axial motion.  The primary containment was declared         |
| inoperable at 1650 CDT on 07/11/01, and removal was initiated.  This is an   |
| 8-hour report under 10CFR50.72(b)(3)(ii)(a) as a degraded condition and      |
| 10CFR50.72(b)(3)(v)(c and d), control of radiation release and accident      |
| mitigation.                                                                  |
|                                                                              |
| The licensee initiated a required shutdown at 2050 CDT on 07/11/01 per       |
| Technical Specification 3.7.A.2.a, as a result of declaring primary          |
| containment inoperable because the drywell-to-torus vent pipe bellows        |
| shipping installation attachments were still installed.  This is a 4-hour    |
| report under 10CFR50.72(b)(2)(i), technical specification required           |
| shutdown.                                                                    |
|                                                                              |
| The licensee notified the NRC resident inspector and intends to notify state |
| and local agencies.                                                          |
|                                                                              |
| ***** UPDATE FROM DAVE BARNETT RECEIVED BY LEIGH TROCINE AT 0039 EDT ON      |
| 07/12/01 *****                                                               |
|                                                                              |
| The four shipping fasteners have been removed from each of the eight         |
| drywell-to-torus vent pipe bellows, and primary containment was declared     |
| operable at 2304 CDT on 07/11/01.  The technical specification required      |
| shutdown was terminated while the reactor was at 90% power.  The licensee    |
| currently plans to restore reactor power to 100%.                            |
|                                                                              |
| The licensee plans to notify the NRC resident inspector as well as the       |
| applicable state and county agencies.  The NRC operations officer notified   |
| the R3DO (Hills).                                                            |
|                                                                              |
|                                                                              |
| **** RETRACTION ON 08/13/01 AT 1253ET BY D. BARNETT TAKEN BY MACKINNON ****  |
|                                                                              |
| Subsequent evaluation has shown the bellows as well as the drywell and torus |
| attachments capable of performing their design safety functions.  Therefore, |
| Primary Containment was considered operable at all times and this event is   |
| not considered reportable.  The licensee will notify state and local         |
| officials of this retraction. R3DO (T. Kozak) notified.                      |
|                                                                              |
| The NRC Resident Inspector will be notified of this event by the licensee.   |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   38203       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: SAINT LUCIE              REGION:  2  |NOTIFICATION DATE: 08/13/2001|
|    UNIT:  [1] [2] []                STATE:  FL |NOTIFICATION TIME: 15:04[EDT]|
|   RXTYPE: [1] CE,[2] CE                        |EVENT DATE:        08/13/2001|
+------------------------------------------------+EVENT TIME:        13:10[EDT]|
| NRC NOTIFIED BY:  BREEN                        |LAST UPDATE DATE:  08/13/2001|
|  HQ OPS OFFICER:  JOHN MacKINNON               +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          NON EMERGENCY         |CAUDLE JULIAN        R2      |
|10 CFR SECTION:                                 |                             |
|APRE 50.72(b)(2)(xi)     OFFSITE NOTIFICATION   |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          Y       100      Power Operation  |100      Power Operation  |
|2     N          Y       100      Power Operation  |100      Power Operation  |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| OFFSITE NOTIFICATION TO THE FLORIDA DEPARTMENT OF ENVIRONMENTAL PROTECTION   |
|                                                                              |
| An immature green sea turtle was rescued from the plant's intake canal.  The |
| turtle is alive but in need of rehabilitation.  As required by the plant's   |
| sea turtle permit, the Florida Department of Environmental Protection        |
| (Florida Fish and Wildlife) was notified of this event.                      |
|                                                                              |
| The NRC Resident Inspector was notified of this event by the licensee.       |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|General Information or Other                     |Event Number:   38204       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG:  SCIENTECH, INC.                      |NOTIFICATION DATE: 08/13/2001|
|LICENSEE:  NUS INSTRUMENTS, INC.                |NOTIFICATION TIME: 17:14[EDT]|
|    CITY:  GAITHERSBURG             REGION:  1  |EVENT DATE:        08/07/2001|
|  COUNTY:                            STATE:  MD |EVENT TIME:             [EDT]|
|LICENSE#:                        AGREEMENT:  Y  |LAST UPDATE DATE:  08/13/2001|
|  DOCKET:                                       |+----------------------------+
|                                                |PERSON          ORGANIZATION |
|                                                |RONALD BELLAMY       R1      |
|                                                |VERN HODGE, FAX      NRR     |
+------------------------------------------------+                             |
| NRC NOTIFIED BY:  MARTIN BOOSKA                |                             |
|  HQ OPS OFFICER:  JOHN MacKINNON               |                             |
+------------------------------------------------+                             |
|EMERGENCY CLASS:          NON EMERGENCY         |                             |
|10 CFR SECTION:                                 |                             |
|CCCC 21.21               UNSPECIFIED PARAGRAPH  |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| POTENTIAL DEFECT                                                             |
|                                                                              |
| SCIENTECH, Inc.'s subsidiary NUS Instruments, Inc. (NUSI) has determined     |
| that a Basic Component, supplied to Rochester Gas and Electric Ginna Station |
| Nuclear Plant under RG&E purchase order 5000002014, contains a potential     |
| defect that is reportable under 10CFR21.  NUSI determined that the potential |
| defect was reportable under the provisions of 10CFR21 on August 07, 2001.    |
| SCIENTECH, Inc. President was informed August 13, 2001.  RG&E is aware of    |
| this problem and the affected component is being modified to restore this    |
| item to an acceptable status by August 17.                                   |
|                                                                              |
| A formal written report will be provided within 30 days of this              |
| notification.  The component, delta T Time Domain Module, M/N:               |
| TMD500-08/08/08/08-08-08-1/2, P/N: MBA-E063PA-1, Rev. 0 (1ea.), S/N:9800771, |
| was originally manufactured as P/N: MBA-E062PA-1 (voltage output) by NUSI.   |
| NUSI performed a conversion of this item to P/N: MBA-E063PA-1 (current       |
| output) resulting in a defect.  A total of six items were converted under    |
| this purchase order for use in Safety Related Systems.  NUSI has opened a    |
| 10CFR21 file concerning this component and has numbered it as 21-01-01.      |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Fuel Cycle Facility                              |Event Number:   38205       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: PORTSMOUTH GASEOUS DIFFUSION PLANT   |NOTIFICATION DATE: 08/13/2001|
|   RXTYPE: URANIUM ENRICHMENT FACILITY          |NOTIFICATION TIME: 20:40[EDT]|
| COMMENTS: 2 DEMOCRACY CENTER                   |EVENT DATE:        08/13/2001|
|           6903 ROCKLEDGE DRIVE                 |EVENT TIME:        14:15[EDT]|
|           BETHESDA, MD 20817    (301)564-3200  |LAST UPDATE DATE:  08/13/2001|
|    CITY:  PIKETON                  REGION:  3  +-----------------------------+
|  COUNTY:  PIKE                      STATE:  OH |PERSON          ORGANIZATION |
|LICENSE#:  GDP-2                 AGREEMENT:  N  |THOMAS KOZAK         R3      |
|  DOCKET:  0707002                              |SUSAN FRANT          NMSS    |
+------------------------------------------------+                             |
| NRC NOTIFIED BY:  JIM McCLEERY                 |                             |
|  HQ OPS OFFICER:  JOHN MacKINNON               |                             |
+------------------------------------------------+                             |
|EMERGENCY CLASS:          NON EMERGENCY         |                             |
|10 CFR SECTION:                                 |                             |
|NBNL                     RESPONSE-BULLETIN      |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| LOSS OF ONE CONTROL OF THE DOUBLE CONTINGENCY PRINCIPLE                      |
|                                                                              |
| NRC BULLETIN 91-01 24 HOUR NOTIFICATION                                      |
|                                                                              |
| At 1415 8/13/01 loose plastic wrap was discovered on a storage shelf in an   |
| inadvertent container area and was not configured or secured such that it    |
| cannot be deformed into an inadvertent container with an unsafe accumulation |
| potential.  This is a violation of control # 5 of NCSA705_076.A03, "Use Of   |
| Inadvertent Containers".  A pump located on a lower shelf apparently had a   |
| pump flange cover dislodged, uncovering a potential inadvertent container.   |
| This is a violation of control # 3 of the same NCSA.                         |
|                                                                              |
| The PSS entered an anomalous condition.  The plastic wrap and pump were      |
| removed from the inadvertent Container area.  The PSS exited the anomalous   |
| condition.                                                                   |
|                                                                              |
| SAFETY SIGNIFICANCE OF THE EVENTS: LOW                                       |
|                                                                              |
| There was no leak of uranium bearing material in the vicinity of the plastic |
| or the uncovered pump.                                                       |
|                                                                              |
| POTENTIAL CRITICALITY PATHWAYS INVOLVED (BRIEF SCENARIO OF HOW CRITICALITY   |
| COULD OCCUR):                                                                |
|                                                                              |
| For a criticality to occur, the following events would be required:  The     |
| microfiltration system would have to be processing uranium bearing liquid    |
| with an unknown or high concentration of uranium.  Then a leak in this       |
| system must occur such that an unsafe amount of liquid sprays from the       |
| system onto the plastic wrap or uncovered pump.  The plastic would then have |
| to deform or the pump would have to fill such that 2.5 liters collects to a  |
| depth of greater than 1.5 inches.                                            |
|                                                                              |
| CONTROLLED PARAMETERS (MASS, MODERATION, GEOMETRY, CONCENTRATION, ETC.):     |
| volume, geometry                                                             |
|                                                                              |
| Inadvertent containers are controlled based upon volume (2.5 liter) or       |
| geometry (1.5" or 4" diameter). Flexible material is specifically controlled |
| such that solution cannot pool to a depth greater than 1.5 inches.           |
|                                                                              |
| ESTIMATED AMOUNT, ENRICHMENT, FORM OF LICENSED MATERIAL (INCLUDE PROCESS     |
| LIMIT AND % WORST CASE CRITICAL MASS):                                       |
|                                                                              |
| No uranium material was involved in this event.                              |
|                                                                              |
| NUCLEAR CRITICALITY SAFETY CONTROL(S) OR CONTROL SYSTEM(S) AND DESCRIPTION   |
| OF THE FAILURES OR DEFICIENCIES                                              |
|                                                                              |
| Loose plastic wrap was not configured or secured to prevent deformation into |
| an inadvertent container.  The pump flange cover was dislodged.  The pump    |
| was located on a lower shelf in the same area.  This is a violation as       |
| control # 5 and # 3 respectively of NCSA-705_076.A.03.                       |
|                                                                              |
|                                                                              |
| CORRECTIVE ACTIONS TO RESTORE SAFETY SYSTEM AND WHEN EACH WAS IMPLEMENTED:   |
|                                                                              |
| The plastic wrap and pump were removed from the inadvertent container area.  |
|                                                                              |
|                                                                              |
|                                                                              |
| The NRC Resident Inspector was notified of this event report by the          |
| certificate holder.                                                          |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   38206       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: PILGRIM                  REGION:  1  |NOTIFICATION DATE: 08/13/2001|
|    UNIT:  [1] [] []                 STATE:  MA |NOTIFICATION TIME: 21:31[EDT]|
|   RXTYPE: [1] GE-3                             |EVENT DATE:        08/13/2001|
+------------------------------------------------+EVENT TIME:        17:53[EDT]|
| NRC NOTIFIED BY:  V. FALLACARA                 |LAST UPDATE DATE:  08/13/2001|
|  HQ OPS OFFICER:  JOHN MacKINNON               +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          NON EMERGENCY         |RONALD BELLAMY       R1      |
|10 CFR SECTION:                                 |                             |
|ARPS 50.72(b)(2)(iv)(B)  RPS ACTUATION - CRITICA|                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     A/R        Y       100      Power Operation  |0        Hot Shutdown     |
|                                                   |                          |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| UNEXPECTED REACTOR SCRAM DURING LOGIC SYSTEM TESTING OF EMERGENCY BUS A5.    |
|                                                                              |
| Pilgrim Unit 1 scrammed from 100% during performance of Logic System Testing |
| of Emergency Bus A5.  This is the first time that  the Logic System Testing  |
| of Emergency Bus A5 had been performed at power. The test is performed once  |
| every 24 months and had just been rewritten to be performed at power.  The   |
| cause of the scram is under investigation at this time but the initiating    |
| transient was the loss of Emergency Bus A5.  All rods fully inserted into    |
| the core.   The plant is at 700 lbs. and a controlled depressurization is in |
| progress.  Plans are to cooldown to less than or equal to 150 lbs. and       |
| repair the outboard RCIC steam isoaltion valve.                              |
|                                                                              |
| Due to deenergization of Emergency Bus A5 Recirculation Pump A tripped and   |
| there was a fast transfer of the swing bus (this was expected).  The         |
| licensee is looking into the transfer of the swing bus causing the trip of   |
| Recirculation Pump B.  Loss of both operating Recirculation Pumps at power   |
| will cause a reactor scram.    All systems operated properly.  The           |
| electrical grid is stable and all Emergency Core Cooling systems are fully   |
| operable if needed.  The Recirculation pumps will be restarted when the      |
| differential temperature between the top and bottom head are within          |
| specification.                                                               |
|                                                                              |
| The NRC Resident Inspector was notified of this event by the licensee.       |
+------------------------------------------------------------------------------+


Page Last Reviewed/Updated Thursday, March 25, 2021

Page Last Reviewed/Updated Thursday, March 25, 2021