Event Notification Report for June 5, 2001
U.S. Nuclear Regulatory Commission
Operations Center
Event Reports For
06/04/2001 - 06/05/2001
** EVENT NUMBERS **
37902 38049 38050 38051 38052
+------------------------------------------------------------------------------+
|Power Reactor |Event Number: 37902 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: CRYSTAL RIVER REGION: 2 |NOTIFICATION DATE: 04/09/2001|
| UNIT: [3] [] [] STATE: FL |NOTIFICATION TIME: 11:08[EDT]|
| RXTYPE: [3] B&W-L-LP |EVENT DATE: 04/09/2001|
+------------------------------------------------+EVENT TIME: 09:54[EDT]|
| NRC NOTIFIED BY: RICHARD SWEENEY |LAST UPDATE DATE: 06/04/2001|
| HQ OPS OFFICER: STEVE SANDIN +-----------------------------+
+------------------------------------------------+PERSON ORGANIZATION |
|EMERGENCY CLASS: NON EMERGENCY |CAUDLE JULIAN R2 |
|10 CFR SECTION: | |
|APRE 50.72(b)(2)(xi) OFFSITE NOTIFICATION | |
| | |
| | |
| | |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|3 N Y 100 Power Operation |100 Power Operation |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| OFFSITE NOTIFICATION TO THE NATIONAL MARINE AND FISHERIES SERVICE AS A |
| RESULT OF THE ENDANGERED SEA TURTLES NON-LETHAL TAKE LIMIT BEING EXCEEDED |
| |
| "On April 09, 2001 at 0940 the 40th non-lethal sea turtle take in the |
| biennial period occurred. |
| |
| "In accordance with Crystal River Unit #3 Operating License, Appendix B, |
| Environmental Protection Plan (Non-Radiological), 'Endangered or threatened |
| sea turtles shall be protected in accordance with the Incidental Take |
| Statement issued by the National Marine and Fisheries Service (NMFS).' The |
| NMFS has established numerical limits on live takes, lethal takes causally |
| related to plant operation, and lethal takes not related to plant |
| operations. |
| |
| "The NMFS must be notified within five days whenever: |
| |
| a. The 40th non-lethal take occurs in the biennial period, or |
| b. The third causally related mortality occurs in the biennial period, or |
| c. The sixth non-causally related mortality occurs in the biennial |
| period. |
| |
| "The current biennial period for monitoring sea turtle takes began January |
| 1, 2001. |
| |
| "Thus, in accordance with Crystal Unit #3 Administrative Instruction 571, |
| Sea Turtle Rescue and Handling Guidance, the NMFS must be notified within |
| five days. |
| |
| "In accordance with Crystal River Unit #3 Compliance Procedure 151, External |
| Reporting Requirements, this 40th non-lethal sea turtle take is Reportable |
| as a 4-Hour Report under 10 CFR 50.72(b)(2)(xi) as this event is related to |
| the protection of the environment for which a notification to other |
| government agencies has been or will be made." |
| |
| The licensee will inform the NRC resident inspector. |
| |
| * * * UPDATE 0944EDT ON 4/10/01 FROM R. SWEENEY TO S. SANDIN * * * |
| |
| "On April 10, 2001 at 0859 the 41st non-lethal sea turtle take in the |
| biennial period occurred." |
| |
| The licensee informed the NRC resident inspector. Notified R2DO(Julian). |
| |
| ***** UPDATE RECEIVED AT 0911 ON 04/17/01 FROM CHRISTOPHER PELLERIN TO LEIGH |
| TROCINE ***** |
| |
| The 42nd, non-lethal, sea turtle take in the biennial period occurred at |
| 0810 on April 17, 2001. |
| |
| The licensee notified the NRC resident inspector. The NRC operations |
| officer notified the R2DO (Ernstes). |
| |
| * * * UPDATE 1125 EDT ON 5/1/01 FROM DAVID SCHULKER TO FANGIE JONES * * * |
| |
| "On May 1, 2001 at 0805 a turtle was identified as the 43rd rescued, live |
| sea turtle in this biennial period. This sea turtle will be kept for a |
| short observation period and then safely returned to the environment." |
| |
| The licensee will inform the NRC Resident Inspector and the National |
| Wildlife and Fisheries Service. Notified R2DO(Jay Henson). |
| |
| * * * UPDATE ON 5/29/01 BY FERGUSON TO SANDIN * * * |
| |
| On May 29, 2001 at 0943 two turtles were identified as the 44th and 45th |
| rescued, Iive Sea turtles in this biennial period. These healthy sea turtles |
| will be kept for a short observation period and then safely returned to the |
| environment. |
| |
| |
| This is Reportable as a 4-Hour Report under 10 CFR 50.72 (b) (2) (xi) as |
| this event is related to the protection of the environment for which a |
| notification to other government agencies has been or will be made. This is |
| an update to event 37902. |
| |
| The NRC Resident Inspector was notified. The REG2 RDO(Barr) was informed. |
| |
| * * * UPDATE 2014 EDT 6/4/2001 FROM RAWLS TAKEN BY STRANSKY * * * |
| |
| On June 4, 2001 at 1815, the 46th non-lethal sea turtle (Kemp's Ridley) take |
| in the biennial period occurred. The license has informed the NRC resident |
| inspector. Notified R2DO (Barr). |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|Power Reactor |Event Number: 38049 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: CALVERT CLIFFS REGION: 1 |NOTIFICATION DATE: 06/04/2001|
| UNIT: [1] [2] [] STATE: MD |NOTIFICATION TIME: 09:24[EDT]|
| RXTYPE: [1] CE,[2] CE |EVENT DATE: 06/04/2001|
+------------------------------------------------+EVENT TIME: 09:10[EDT]|
| NRC NOTIFIED BY: JAMES GROOMS |LAST UPDATE DATE: 06/04/2001|
| HQ OPS OFFICER: FANGIE JONES +-----------------------------+
+------------------------------------------------+PERSON ORGANIZATION |
|EMERGENCY CLASS: NON EMERGENCY |ERIC REBER R1 |
|10 CFR SECTION: | |
|APRE 50.72(b)(2)(xi) OFFSITE NOTIFICATION | |
| | |
| | |
| | |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1 N Y 100 Power Operation |100 Power Operation |
|2 N Y 100 Power Operation |100 Power Operation |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| OFFSITE NOTIFICATION TO THE DEPARTMENT OF NATURAL RESOURCES |
| |
| The licensee discovered a dead sea turtle on the cleaning racks of the |
| intake structure. The species of turtle is unknown and the licensee is |
| calling the Department of Natural Resources for help in determining if the |
| turtle is an endangered species. |
| |
| The licensee notified the NRC Resident Inspector. |
+------------------------------------------------------------------------------+
!!!!!!!!! THIS EVENT HAS BEEN RETRACTED. THIS EVENT HAS BEEN RETRACTED !!!!!!!
+------------------------------------------------------------------------------+
|Hospital |Event Number: 38050 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG: WESTERN MISSOURI MEDICAL CENTER |NOTIFICATION DATE: 06/04/2001|
|LICENSEE: WESTERN MISSOURI MEDICAL CENTER |NOTIFICATION TIME: 12:52[EDT]|
| CITY: WARRENSBURG REGION: 3 |EVENT DATE: 06/04/2001|
| COUNTY: STATE: MO |EVENT TIME: 08:00[CDT]|
|LICENSE#: AGREEMENT: N |LAST UPDATE DATE: 06/04/2001|
| DOCKET: |+----------------------------+
| |PERSON ORGANIZATION |
| |BRENT CLAYTON R3 |
| |JOHN HICKEY NMSS |
+------------------------------------------------+ |
| NRC NOTIFIED BY: RANDY WHITCOMB | |
| HQ OPS OFFICER: BOB STRANSKY | |
+------------------------------------------------+ |
|EMERGENCY CLASS: NON EMERGENCY | |
|10 CFR SECTION: | |
|LADM 35.33(a) MED MISADMINISTRATION | |
| | |
| | |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| PATIENT ADMINISTERED INCORRECT DOSE AND CHEMICAL FORM OF TECHNETIUM-99m |
| |
| A patient was prescribed a dose of 17 mCi of Tc-99m (MDP) for a bone scan; |
| however, the patient actually received a dose of 5 mCi of Tc-99m (collatec). |
| The licensee stated that a medical technician picked up the wrong syringe. |
| The patient and attending physician have be informed by the licensee. |
| |
| * * * RETRACTION 1542 6/4/2001 FROM WHITCOMB TAKEN BY STRANSKY * * * |
| |
| After discussion with NRC Region III, the licensee has determined that this |
| event does not constitute a medical misadministration. Notified R3DO |
| (Clayton). |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|Power Reactor |Event Number: 38051 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: BROWNS FERRY REGION: 2 |NOTIFICATION DATE: 06/04/2001|
| UNIT: [] [2] [3] STATE: AL |NOTIFICATION TIME: 16:57[EDT]|
| RXTYPE: [1] GE-4,[2] GE-4,[3] GE-4 |EVENT DATE: 04/11/2001|
+------------------------------------------------+EVENT TIME: 08:27[CDT]|
| NRC NOTIFIED BY: RAY SWAFFORD |LAST UPDATE DATE: 06/04/2001|
| HQ OPS OFFICER: BOB STRANSKY +-----------------------------+
+------------------------------------------------+PERSON ORGANIZATION |
|EMERGENCY CLASS: NON EMERGENCY |KEN BARR R2 |
|10 CFR SECTION: | |
|AINV 50.73(a)(1) INVALID SPECIF SYSTEM A| |
| | |
| | |
| | |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE |
+-----+----------+-------+--------+-----------------+--------+-----------------+
| | |
|2 N N 0 Refueling |0 Refueling |
|3 N Y 100 Power Operation |100 Power Operation |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| INVALID PRIMARY CONTAINMENT ISOLATION SYSTEM ACTUATION DURING |
| POST-MODIFICATION TEST ACTIVITIES |
| |
| "This 60-day telephone notification is being made under reporting |
| requirements specified by 10 CFR 50.73(a)(2)(iv)(A), to describe an invalid |
| actuation of the primary containment isolation system. |
| |
| "Unit 2 was in mode 5 on day 24 of a scheduled refueling outage with the |
| reactor cavity flooded. Unit 3 was at 100 percent power. The impact on the |
| facility from the event was minimal. The plant equipment responded |
| correctly. |
| |
| "On April 11, 2001 at 0827 hours Central Daylight Time, Unit 2 received |
| invalid Group 2, 3, 6 and 8 Primary Containment Isolation Signals (PCIS) |
| during performance of Post-Modification Testing (PMT) activities. The PCIS |
| isolations were a result of an invalid low reactor water level signal |
| generated when the power fuses were removed during the test, |
| |
| "The following actuations/isolations occurred: (Group 3) Reactor Water |
| Cleanup system isolated, (Group 6) Stand by Gas Treatment system Trains A, |
| B, and C started, Control Room Emergency Ventilation B started, and |
| ventilation systems that were not removed from service. Groups 2 and 8 |
| components were removed from service to support outage activities, |
| subsequently, no equipment response occurred. |
| |
| "The effected systems were returned to their pre-event configuration. There |
| were no safety consequences or compromises to the health and safety of the |
| public. The event was entered into TVA's corrective action program for |
| resolution. |
| |
| "The NRC Site Resident Inspector has been notified." |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|Power Reactor |Event Number: 38052 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: KEWAUNEE REGION: 3 |NOTIFICATION DATE: 06/05/2001|
| UNIT: [1] [] [] STATE: WI |NOTIFICATION TIME: 04:59[EDT]|
| RXTYPE: [1] W-2-LP |EVENT DATE: 06/05/2001|
+------------------------------------------------+EVENT TIME: 00:00[CDT]|
| NRC NOTIFIED BY: BRADLY McMAHON |LAST UPDATE DATE: 06/05/2001|
| HQ OPS OFFICER: FANGIE JONES +-----------------------------+
+------------------------------------------------+PERSON ORGANIZATION |
|EMERGENCY CLASS: NON EMERGENCY |BRENT CLAYTON R3 |
|10 CFR SECTION: | |
|ACOM 50.72(b)(3)(xiii) LOSS COMM/ASMT/RESPONSE| |
| | |
| | |
| | |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1 N Y 97 Power Operation |97 Power Operation |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| LOSS OF PROCESS COMPUTER WITH LINK TO SAFETY PARAMETERS DISPLAY SYSTEM |
| |
| The plant process computer system failed. This system provides a link to |
| the Safety Parameter Display System (SPDS). Immediate actions were taken to |
| restore the computer and SPDS to no avail. The plant computer group |
| representative has been called in to address the computer problem. Work |
| continues to try and restore the computer to operation. Also, the |
| availability of the Emergency Response Data System (ERDS) availability is |
| questionable. |
| |
| The licensee notified the NRC Resident Inspector. |
+------------------------------------------------------------------------------+