Due to a lapse in appropriations, the NRC has ceased normal operations. However, excepted and exempted activities necessary to maintain critical health and safety functions—as well as essential progress on designated critical activities, including those specified in Executive Order 14300—will continue, consistent with the OMB-Approved NRC Lapse Plan.

Event Notification Report for March 2, 2001

                    U.S. Nuclear Regulatory Commission
                              Operations Center

                              Event Reports For
                           03/01/2001 - 03/02/2001

                              ** EVENT NUMBERS **

37673  37791  37792  37793  37794  37795  37796  37797  

!!!!!!!!! THIS EVENT HAS BEEN RETRACTED. THIS EVENT HAS BEEN RETRACTED  !!!!!!!
+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   37673       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: COOPER                   REGION:  4  |NOTIFICATION DATE: 01/21/2001|
|    UNIT:  [1] [] []                 STATE:  NE |NOTIFICATION TIME: 18:29[EST]|
|   RXTYPE: [1] GE-4                             |EVENT DATE:        01/21/2001|
+------------------------------------------------+EVENT TIME:        15:28[CST]|
| NRC NOTIFIED BY:  WILLIAM GREEN                |LAST UPDATE DATE:  03/01/2001|
|  HQ OPS OFFICER:  DOUG WEAVER                  +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |KRISS KENNEDY        R4      |
|10 CFR SECTION:                                 |                             |
|AIND 50.72(b)(2)(iii)(D) ACCIDENT MITIGATION    |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          Y       100      Power Operation  |100      Power Operation  |
|                                                   |                          |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| CONTROL ROOM EMERGENCY FILTRATION SYSTEM INOPERABLE                          |
|                                                                              |
| At 1528 the Control Room Emergency Filtration System (CREFS) was declared    |
| inoperable when fire door H305 was noted to hang open instead of fully       |
| closing when personnel passed through the door.   BLDG-DOOR-H305 is a        |
| Control Room Envelope Door.  CREFS is a single train system.   When CREFS    |
| was determined to be inoperable Technical Specification LCO 3.7.4 condition  |
| A was entered.  This LCO requires the restoration of CREFS to OPERABLE       |
| status within 7 days or be in MODE 3 within 12 hours and MODE 4 within 36    |
| hours.                                                                       |
|                                                                              |
| Following the transfer of CREFS to DIV 1 power at 13:30, it was subsequently |
| noted that the control room blast doors seemed harder to open than normal.   |
| The ventilation lineup for the Control Building was verified to be correct.  |
| During this verification it was determined that BLDG-DOOR-H305 would not     |
| operate properly and the door and CREFS were declared inoperable.            |
|                                                                              |
| Ventilation flow through other Control Room Boundary Doors appears [to]be    |
| abnormal for the present ventilation lineup.  A Fire Watch has been          |
| stationed at BLDG-DOOR-H305.  A Problem Identification Report has been       |
| initiated to identify that BLDG-DOOR-H305 will not close by itself from the  |
| fully open position. The ventilation lineup has not been changed since the   |
| discovery of this condition for evidence preservation.  The Ventilation      |
| System Engineer is responding to the Site to assist with troubleshooting of  |
| the ventilation system.                                                      |
|                                                                              |
| The licensee notified the NRC resident inspector.                            |
|                                                                              |
| * * * UPDATE 1514EST ON 3/1/01 FROM DAVID VANDERKAMP TO S. SANDIN * * *      |
|                                                                              |
| The licensee is retracting this report based on the following:               |
|                                                                              |
| "Basis for Retraction:                                                       |
|                                                                              |
| "Event Number 37673 reported a condition at Cooper Nuclear Station (CNS)     |
| where the Control Room Emergency Filtration System (CREFS) was declared      |
| inoperable. This was a result of the control room envelope boundary being    |
| declared inoperable due to a fire door not closing automatically when it was |
| opened raising questions about integrity of the envelope.                    |
|                                                                              |
| "On a specific occasion, a fire door that allows access from the control     |
| room access hall to the computer room, was unable to close without           |
| assistance. This was discovered when an operator passed through the door and |
| it failed to close behind him. He had to manually assist the door closed.    |
| The door was declared inoperable as a fire boundary door and a fire watch    |
| was posted. Since the door forms part of the control room envelope boundary, |
| that boundary was also declared inoperable due to concerns about the         |
| envelope integrity. Therefore, CREFS was declared inoperable.                |
|                                                                              |
| "Technical Specifications require that the control room envelope be          |
| maintained at a positive pressure in the emergency line-up on the control    |
| room ventilation system but not in the normal line-up. This should be        |
| considered a normal operation of the door for entry and exit per Technical   |
| Specification Bases 3.7.4. This states that:                                 |
|                                                                              |
| '...in addition, the control room boundary must be maintained, including the |
| integrity of the walls, floors, ceilings, ductwork and access doors, such    |
| that the pressurization limit of SR 3.7.4.4 can be met. However, it is       |
| acceptable for access doors to be open for normal control room entry and     |
| exit, and not consider it to be a failure to meet the LCO.'                  |
|                                                                              |
| "There was no condition present that would challenge the integrity of the    |
| Control Room envelope, other than the door not closing automatically. The    |
| door was manually closed while being used for access. Signs are posted at    |
| doors that should be closed to ensure that doors are closed after they are   |
| opened. The operator passing through this door closed the door when it would |
| not close by itself. Not withstanding the fact that the door was             |
| closed as required; a Fire Watch was posted to better ensure that the door   |
| was properly closed until the reason for it's not automatically closing was  |
| determined. No major components failed.                                      |
|                                                                              |
| "The cause of the door not automatically closing was determined to be a      |
| mis-positioned, manually operated damper. The mis-positioned damper caused a |
| decreased positive pressure inside the Control Room envelope boundary        |
| impacting the automatic door closure. If an accident had occurred while this |
| damper was mis-positioned, the Control Room Emergency Filtration System      |
| would have performed its safety function as designed and continued to be     |
| operable.                                                                    |
|                                                                              |
| "Based on this updated information, the District has determined that this    |
| event is not reportable under the requirements of 10CFR50.72(b)(2)(iii)(D),  |
| and as such, event 37673 is retracted."                                      |
|                                                                              |
| The licensee will inform the NRC resident inspector.  Notified R4DO(Howell). |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   37791       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: SUMMER                   REGION:  2  |NOTIFICATION DATE: 03/01/2001|
|    UNIT:  [1] [] []                 STATE:  SC |NOTIFICATION TIME: 03:19[EST]|
|   RXTYPE: [1] W-3-LP                           |EVENT DATE:        03/01/2001|
+------------------------------------------------+EVENT TIME:        00:17[EST]|
| NRC NOTIFIED BY:  SIMPSON                      |LAST UPDATE DATE:  03/01/2001|
|  HQ OPS OFFICER:  CHAUNCEY GOULD               +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |STEPHEN CAHILL       R2      |
|10 CFR SECTION:                                 |                             |
|*RPS 50.72(b)(2)(iv)(B)  RPS ACTUATION - CRITICA|                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     M/R        Y       1        Startup          |0        Hot Standby      |
|                                                   |                          |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| REACTOR WAS MANUALLY TRIPPED AT LESS THAN 1% POWER                           |
|                                                                              |
|                                                                              |
| A manual reactor trip was initiated at 0017 on 3/01/01 due to 2 shutdown     |
| control rods remaining on the bottom while initiating control rod            |
| withdrawal.  This occurred during low power physics testing and a trouble    |
| shooting plan for a misaligned Shutdown bank B Control rod (G-9).  The rod   |
| had already been realigned to the other rods in shutdown bank B @ 43 steps.  |
| The Shutdown bank was inserted into the core to zero steps per the trouble   |
| shooting plan.   After the step counters and rod control were reset and      |
| Shutdown bank B rods were being withdrawn, it was discovered that 2 rods had |
| not moved and were still on the bottom with 14 steps demanded. The Shutdown  |
| bank was re-inserted to zero steps (fully inserted).   After further         |
| discussion, the shift supervisor called for a manual reactor trip.  The      |
| reactor operator tripped the Reactor and the Crew entered the Emergency      |
| Operation Procedures  (EOP-1.0, Reactor trip/safety injection, and EOP-1.1,  |
| Reactor trip recovery).   All systems functioned as designed.  The problem   |
| with the rod control system is not understood and trouble shooting is        |
| continuing.                                                                  |
|                                                                              |
|                                                                              |
| Note: The 2 rods that did not move were rods G-9 and L-5, both in Shutdown   |
| bank B.                                                                      |
|                                                                              |
| The NRC Resident Inspector was notified.                                     |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   37792       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: INDIAN POINT             REGION:  1  |NOTIFICATION DATE: 03/01/2001|
|    UNIT:  [2] [] []                 STATE:  NY |NOTIFICATION TIME: 05:42[EST]|
|   RXTYPE: [2] W-4-LP,[3] W-4-LP                |EVENT DATE:        03/01/2001|
+------------------------------------------------+EVENT TIME:        05:00[EST]|
| NRC NOTIFIED BY:  KICH                         |LAST UPDATE DATE:  03/01/2001|
|  HQ OPS OFFICER:  CHAUNCEY GOULD               +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |RICHARD CONTE        R1      |
|10 CFR SECTION:                                 |                             |
|*PRE 50.72(b)(2)(xi)     OFFSITE NOTIFICATION   |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|2     N          Y       100      Power Operation  |100      Power Operation  |
|                                                   |                          |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| THE LICENSEE NOTIFIED STATE AND COUNTY OFFICIALS OF A TRANSIT STRIKE IN      |
| WESTCHESTER COUNTY.                                                          |
|                                                                              |
| The licensee was notified that transit employees of the Liberty Bus Company  |
| in Westchester County will be going on strike.  The licensee made the        |
| offsite notifications to assure that the contingency plans are in effect to  |
| deal with the strike.                                                        |
|                                                                              |
| The NRC Resident Inspector will be notified.                                 |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   37793       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: INDIAN POINT             REGION:  1  |NOTIFICATION DATE: 03/01/2001|
|    UNIT:  [] [3] []                 STATE:  NY |NOTIFICATION TIME: 06:33[EST]|
|   RXTYPE: [2] W-4-LP,[3] W-4-LP                |EVENT DATE:        03/01/2001|
+------------------------------------------------+EVENT TIME:        05:00[EST]|
| NRC NOTIFIED BY:  YOUNG                        |LAST UPDATE DATE:  03/01/2001|
|  HQ OPS OFFICER:  CHAUNCEY GOULD               +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |RICHARD CONTE        R1      |
|10 CFR SECTION:                                 |                             |
|*PRE 50.72(b)(2)(xi)     OFFSITE NOTIFICATION   |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|                                                   |                          |
|3     N          Y       100      Power Operation  |100      Power Operation  |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| THE LICENSEE NOTIFIED STATE AND COUNTY OFFICIALS OF A TRANSIT STRIKE IN      |
| WESTCHESTER COUNTY.                                                          |
|                                                                              |
| The  licensee was notified that transit employees of the Liberty Bus Company |
| in Westchester County will be going on strike.  The licensee made the        |
| offsite notifications to assure that the contingency plans are in effect to  |
| deal with the strike.                                                        |
|                                                                              |
| The NRC Resident Inspector was notified.                                     |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   37794       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: SOUTH TEXAS              REGION:  4  |NOTIFICATION DATE: 03/01/2001|
|    UNIT:  [] [2] []                 STATE:  TX |NOTIFICATION TIME: 12:55[EST]|
|   RXTYPE: [1] W-4-LP,[2] W-4-LP                |EVENT DATE:        03/01/2001|
+------------------------------------------------+EVENT TIME:        08:22[CST]|
| NRC NOTIFIED BY:  ROBERT BRINKLEY              |LAST UPDATE DATE:  03/01/2001|
|  HQ OPS OFFICER:  STEVE SANDIN                 +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |LINDA HOWELL         R4      |
|10 CFR SECTION:                                 |                             |
|*RPS 50.72(b)(2)(iv)(B)  RPS ACTUATION - CRITICA|                             |
|*ESF 50.72(b)(3)(iv)(A)  VALID SPECIF SYS ACTUAT|                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|                                                   |                          |
|2     M/R        Y       95       Power Operation  |0        Hot Standby      |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| MANUAL REACTOR TRIP DUE TO LOSS OF OPERATING CIRCULATING WATER PUMPS         |
|                                                                              |
| "South Texas Project Unit 2 makes the following report in accordance with    |
| 10CFR50.72(b)(2)(iv)(B) and 50.72(b)(3)(iv)(A):                              |
|                                                                              |
| "At 08:22 CST on 3/01/01, a manual Reactor Trip was initiated due to failure |
| of a switchyard breaker and subsequent loss of all operating Circulating     |
| Water Pumps.  All Control Rods fully inserted into the Reactor Core. The     |
| Auxiliary Feedwater system actuated on low-low Steam Generator Water Level   |
| and a Feedwater isolation signal occurred as expected on a trip from 95%     |
| power. Pressurizer heater group 'A' did not energize on low RCS pressure as  |
| required. Cause of the heater group to fail to energize is not known at this |
| time. All four (4) Reactor Coolant pumps remain in operation and decay heat  |
| is currently being removed via the atmospheric steam dumps.  No radiation    |
| above state, federal, and plant operational limits was measured by South     |
| Texas Project's radiation monitoring system."                                |
|                                                                              |
| The licensee is presently making efforts to restore an operating Circulating |
| Water Pump so as to establish Main Condenser vacuum.  Three Circulating      |
| Water Pumps were operating at the time with the fourth out-of-service.  The  |
| licensee has a measured 20gpd Steam Generator tube leakage.  The offsite rad |
| release is within allowable limits.  No other safety equipment is out of     |
| service.  The licensee informed the NRC resident inspector.                  |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|General Information or Other                     |Event Number:   37795       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG:  TEXAS DEPARTMENT OF HEALTH           |NOTIFICATION DATE: 03/01/2001|
|LICENSEE:  QC LABORATORIES, INC.                |NOTIFICATION TIME: 17:00[EST]|
|    CITY:  HOUSTON                  REGION:  4  |EVENT DATE:        02/19/2001|
|  COUNTY:  HARRIS                    STATE:  TX |EVENT TIME:        09:45[CST]|
|LICENSE#:  L04750                AGREEMENT:  Y  |LAST UPDATE DATE:  03/01/2001|
|  DOCKET:                                       |+----------------------------+
|                                                |PERSON          ORGANIZATION |
|                                                |LINDA HOWELL         R4      |
|                                                |JOSEPH HOLONICH      NMSS    |
+------------------------------------------------+                             |
| NRC NOTIFIED BY:  HELEN WATKINS (VIA FAX)      |                             |
|  HQ OPS OFFICER:  STEVE SANDIN                 |                             |
+------------------------------------------------+                             |
|EMERGENCY CLASS:          N/A                   |                             |
|10 CFR SECTION:                                 |                             |
|NAGR                     AGREEMENT STATE        |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| AGREEMENT STATE REPORT INVOLVING A MISSING NUCLEAR DENSITY GAUGE             |
|                                                                              |
| On 2/15/01 an employee of QC Laboratories, Inc. went to a jobsite and never  |
| returned.  The police were notified and are looking for the individual and   |
| the company's 1997 Nissan truck.  The employee was in the possession of a    |
| nuclear density gauge manufactured by Humbolt Scientific, Inc., model        |
| #HS-5001EZ, serial #3145.  The gauge contains two sources; 10 millicuries    |
| Cs-137 (as of 7/14/97 or 10/30/98) and 40 millicuries Am-241:Be.             |
|                                                                              |
| On 3/1/01 additional information was available updating this incident.  The  |
| gauge has been recovered.  The Nissan truck with the gauge locked securely   |
| was parked at a drug rehab facility where the operator had checked himself   |
| in.                                                                          |
|                                                                              |
| Texas Incident #7718.                                                        |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|General Information or Other                     |Event Number:   37796       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG:  TEXAS DEPARTMENT OF HEALTH           |NOTIFICATION DATE: 03/01/2001|
|LICENSEE:  TERRACON                             |NOTIFICATION TIME: 17:00[EST]|
|    CITY:  HOUSTON                  REGION:  4  |EVENT DATE:        02/23/2001|
|  COUNTY:  HARRIS                    STATE:  TX |EVENT TIME:        16:45[CST]|
|LICENSE#:  L05268-001            AGREEMENT:  Y  |LAST UPDATE DATE:  03/01/2001|
|  DOCKET:                                       |+----------------------------+
|                                                |PERSON          ORGANIZATION |
|                                                |LINDA HOWELL         R4      |
|                                                |JOSEPH HOLONICH      NMSS    |
+------------------------------------------------+                             |
| NRC NOTIFIED BY:  HELEN WATKINS (VIA FAX)      |                             |
|  HQ OPS OFFICER:  STEVE SANDIN                 |                             |
+------------------------------------------------+                             |
|EMERGENCY CLASS:          N/A                   |                             |
|10 CFR SECTION:                                 |                             |
|NAGR                     AGREEMENT STATE        |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| AGREEMENT STATE REPORT INVOLVING A STOLEN TROXLER GAUGE                      |
|                                                                              |
| 2/23/01                                                                      |
|                                                                              |
| "At approximately 4:45pm on Friday 2/23/01 a technician realized a truck     |
| with a gauge chained in the back had been stolen. The stolen gauge is a      |
| Troxler Model 3430, serial # 30170. The gauge contained two sources: 8       |
| millicuries of Cs-137, serial # 7501851, and 40 millicuries of Am-241:Be,    |
| serial # 47-27094. [The technician] had checked the gauge our for use at a   |
| jobsite near 1960 Highway 59 in Humble, Texas. [The technician] is a trusted |
| employee and has worked for the company for a long time. The Houston Police  |
| Department was notified.                                                     |
|                                                                              |
| 3/1/01                                                                       |
|                                                                              |
| "The truck and gauge were recovered and returned to the Licensee on 2/28/01. |
| The gauge was still locked in the back of the truck; it was undamaged. A New |
| Orleans, Louisiana resident noticed the truck parked in front of their       |
| residence and called the New Orleans Police Department. The Houston Police   |
| Department was notified and arranged the recovery.                           |
|                                                                              |
| "The Licensee will submit a written report providing additional details on   |
| 3/2/01."                                                                     |
|                                                                              |
| Texas Incident #7726.                                                        |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   37797       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: KEWAUNEE                 REGION:  3  |NOTIFICATION DATE: 03/01/2001|
|    UNIT:  [1] [] []                 STATE:  WI |NOTIFICATION TIME: 18:37[EST]|
|   RXTYPE: [1] W-2-LP                           |EVENT DATE:        03/01/2001|
+------------------------------------------------+EVENT TIME:        09:55[CST]|
| NRC NOTIFIED BY:  KEVIN HUJET                  |LAST UPDATE DATE:  03/01/2001|
|  HQ OPS OFFICER:  STEVE SANDIN                 +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |ANTON VEGEL          R3      |
|10 CFR SECTION:                                 |                             |
|*COM 50.72(b)(3)(xiii)   LOSS COMM/ASMT/RESPONSE|                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          Y       96       Power Operation  |96       Power Operation  |
|                                                   |                          |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| ALERT NOTIFICATION SYSTEM DISCOVERED INOPERABLE                              |
|                                                                              |
| "At 0955, KNPP was notified by the Kewaunee County Sheriffs Office of a      |
| disconnected cable which supplies the siren encoder for the Alert            |
| Notification System.  Subsequent investigation identified that the           |
| transmitter was removed during remodeling, disabling the system from being   |
| activated by the Kewaunee County Dispatch Office, potentially as early as    |
| Monday, 2/26/01.  Normal siren activation would be accomplished from the     |
| Algoma Emergency Operations Center, but the Kewaunee Dispatch location would |
| be used in the event of a fast breaking incident.  It is believed that       |
| processes in place would have lead the Kewaunee Dispatch to pursue alternate |
| methods of activating the sirens, however, it is not clear that this would   |
| have been performed in a timely manner.  Compensatory measures have been     |
| established for the Kewaunee Dispatch/Sheriff to notify the Kewaunee         |
| Emergency Director of the need to activate the sirens.  The Emergency        |
| Director has the capability to activate the sirens remotely and will         |
| maintain this activation function manned until the equipment issues at the   |
| Kewaunee Dispatch have been resolved."                                       |
|                                                                              |
| The licensee informed local authorities and the NRC resident inspector.      |
+------------------------------------------------------------------------------+