Event Notification Report for March 2, 2001
U.S. Nuclear Regulatory Commission Operations Center Event Reports For 03/01/2001 - 03/02/2001 ** EVENT NUMBERS ** 37673 37791 37792 37793 37794 37795 37796 37797 !!!!!!!!! THIS EVENT HAS BEEN RETRACTED. THIS EVENT HAS BEEN RETRACTED !!!!!!! +------------------------------------------------------------------------------+ |Power Reactor |Event Number: 37673 | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ | FACILITY: COOPER REGION: 4 |NOTIFICATION DATE: 01/21/2001| | UNIT: [1] [] [] STATE: NE |NOTIFICATION TIME: 18:29[EST]| | RXTYPE: [1] GE-4 |EVENT DATE: 01/21/2001| +------------------------------------------------+EVENT TIME: 15:28[CST]| | NRC NOTIFIED BY: WILLIAM GREEN |LAST UPDATE DATE: 03/01/2001| | HQ OPS OFFICER: DOUG WEAVER +-----------------------------+ +------------------------------------------------+PERSON ORGANIZATION | |EMERGENCY CLASS: N/A |KRISS KENNEDY R4 | |10 CFR SECTION: | | |AIND 50.72(b)(2)(iii)(D) ACCIDENT MITIGATION | | | | | | | | | | | +-----+----------+-------+--------+-----------------+--------+-----------------+ |UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE | +-----+----------+-------+--------+-----------------+--------+-----------------+ |1 N Y 100 Power Operation |100 Power Operation | | | | | | | +------------------------------------------------------------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | CONTROL ROOM EMERGENCY FILTRATION SYSTEM INOPERABLE | | | | At 1528 the Control Room Emergency Filtration System (CREFS) was declared | | inoperable when fire door H305 was noted to hang open instead of fully | | closing when personnel passed through the door. BLDG-DOOR-H305 is a | | Control Room Envelope Door. CREFS is a single train system. When CREFS | | was determined to be inoperable Technical Specification LCO 3.7.4 condition | | A was entered. This LCO requires the restoration of CREFS to OPERABLE | | status within 7 days or be in MODE 3 within 12 hours and MODE 4 within 36 | | hours. | | | | Following the transfer of CREFS to DIV 1 power at 13:30, it was subsequently | | noted that the control room blast doors seemed harder to open than normal. | | The ventilation lineup for the Control Building was verified to be correct. | | During this verification it was determined that BLDG-DOOR-H305 would not | | operate properly and the door and CREFS were declared inoperable. | | | | Ventilation flow through other Control Room Boundary Doors appears [to]be | | abnormal for the present ventilation lineup. A Fire Watch has been | | stationed at BLDG-DOOR-H305. A Problem Identification Report has been | | initiated to identify that BLDG-DOOR-H305 will not close by itself from the | | fully open position. The ventilation lineup has not been changed since the | | discovery of this condition for evidence preservation. The Ventilation | | System Engineer is responding to the Site to assist with troubleshooting of | | the ventilation system. | | | | The licensee notified the NRC resident inspector. | | | | * * * UPDATE 1514EST ON 3/1/01 FROM DAVID VANDERKAMP TO S. SANDIN * * * | | | | The licensee is retracting this report based on the following: | | | | "Basis for Retraction: | | | | "Event Number 37673 reported a condition at Cooper Nuclear Station (CNS) | | where the Control Room Emergency Filtration System (CREFS) was declared | | inoperable. This was a result of the control room envelope boundary being | | declared inoperable due to a fire door not closing automatically when it was | | opened raising questions about integrity of the envelope. | | | | "On a specific occasion, a fire door that allows access from the control | | room access hall to the computer room, was unable to close without | | assistance. This was discovered when an operator passed through the door and | | it failed to close behind him. He had to manually assist the door closed. | | The door was declared inoperable as a fire boundary door and a fire watch | | was posted. Since the door forms part of the control room envelope boundary, | | that boundary was also declared inoperable due to concerns about the | | envelope integrity. Therefore, CREFS was declared inoperable. | | | | "Technical Specifications require that the control room envelope be | | maintained at a positive pressure in the emergency line-up on the control | | room ventilation system but not in the normal line-up. This should be | | considered a normal operation of the door for entry and exit per Technical | | Specification Bases 3.7.4. This states that: | | | | '...in addition, the control room boundary must be maintained, including the | | integrity of the walls, floors, ceilings, ductwork and access doors, such | | that the pressurization limit of SR 3.7.4.4 can be met. However, it is | | acceptable for access doors to be open for normal control room entry and | | exit, and not consider it to be a failure to meet the LCO.' | | | | "There was no condition present that would challenge the integrity of the | | Control Room envelope, other than the door not closing automatically. The | | door was manually closed while being used for access. Signs are posted at | | doors that should be closed to ensure that doors are closed after they are | | opened. The operator passing through this door closed the door when it would | | not close by itself. Not withstanding the fact that the door was | | closed as required; a Fire Watch was posted to better ensure that the door | | was properly closed until the reason for it's not automatically closing was | | determined. No major components failed. | | | | "The cause of the door not automatically closing was determined to be a | | mis-positioned, manually operated damper. The mis-positioned damper caused a | | decreased positive pressure inside the Control Room envelope boundary | | impacting the automatic door closure. If an accident had occurred while this | | damper was mis-positioned, the Control Room Emergency Filtration System | | would have performed its safety function as designed and continued to be | | operable. | | | | "Based on this updated information, the District has determined that this | | event is not reportable under the requirements of 10CFR50.72(b)(2)(iii)(D), | | and as such, event 37673 is retracted." | | | | The licensee will inform the NRC resident inspector. Notified R4DO(Howell). | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ |Power Reactor |Event Number: 37791 | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ | FACILITY: SUMMER REGION: 2 |NOTIFICATION DATE: 03/01/2001| | UNIT: [1] [] [] STATE: SC |NOTIFICATION TIME: 03:19[EST]| | RXTYPE: [1] W-3-LP |EVENT DATE: 03/01/2001| +------------------------------------------------+EVENT TIME: 00:17[EST]| | NRC NOTIFIED BY: SIMPSON |LAST UPDATE DATE: 03/01/2001| | HQ OPS OFFICER: CHAUNCEY GOULD +-----------------------------+ +------------------------------------------------+PERSON ORGANIZATION | |EMERGENCY CLASS: N/A |STEPHEN CAHILL R2 | |10 CFR SECTION: | | |*RPS 50.72(b)(2)(iv)(B) RPS ACTUATION - CRITICA| | | | | | | | | | | +-----+----------+-------+--------+-----------------+--------+-----------------+ |UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE | +-----+----------+-------+--------+-----------------+--------+-----------------+ |1 M/R Y 1 Startup |0 Hot Standby | | | | | | | +------------------------------------------------------------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | REACTOR WAS MANUALLY TRIPPED AT LESS THAN 1% POWER | | | | | | A manual reactor trip was initiated at 0017 on 3/01/01 due to 2 shutdown | | control rods remaining on the bottom while initiating control rod | | withdrawal. This occurred during low power physics testing and a trouble | | shooting plan for a misaligned Shutdown bank B Control rod (G-9). The rod | | had already been realigned to the other rods in shutdown bank B @ 43 steps. | | The Shutdown bank was inserted into the core to zero steps per the trouble | | shooting plan. After the step counters and rod control were reset and | | Shutdown bank B rods were being withdrawn, it was discovered that 2 rods had | | not moved and were still on the bottom with 14 steps demanded. The Shutdown | | bank was re-inserted to zero steps (fully inserted). After further | | discussion, the shift supervisor called for a manual reactor trip. The | | reactor operator tripped the Reactor and the Crew entered the Emergency | | Operation Procedures (EOP-1.0, Reactor trip/safety injection, and EOP-1.1, | | Reactor trip recovery). All systems functioned as designed. The problem | | with the rod control system is not understood and trouble shooting is | | continuing. | | | | | | Note: The 2 rods that did not move were rods G-9 and L-5, both in Shutdown | | bank B. | | | | The NRC Resident Inspector was notified. | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ |Power Reactor |Event Number: 37792 | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ | FACILITY: INDIAN POINT REGION: 1 |NOTIFICATION DATE: 03/01/2001| | UNIT: [2] [] [] STATE: NY |NOTIFICATION TIME: 05:42[EST]| | RXTYPE: [2] W-4-LP,[3] W-4-LP |EVENT DATE: 03/01/2001| +------------------------------------------------+EVENT TIME: 05:00[EST]| | NRC NOTIFIED BY: KICH |LAST UPDATE DATE: 03/01/2001| | HQ OPS OFFICER: CHAUNCEY GOULD +-----------------------------+ +------------------------------------------------+PERSON ORGANIZATION | |EMERGENCY CLASS: N/A |RICHARD CONTE R1 | |10 CFR SECTION: | | |*PRE 50.72(b)(2)(xi) OFFSITE NOTIFICATION | | | | | | | | | | | +-----+----------+-------+--------+-----------------+--------+-----------------+ |UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE | +-----+----------+-------+--------+-----------------+--------+-----------------+ |2 N Y 100 Power Operation |100 Power Operation | | | | | | | +------------------------------------------------------------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | THE LICENSEE NOTIFIED STATE AND COUNTY OFFICIALS OF A TRANSIT STRIKE IN | | WESTCHESTER COUNTY. | | | | The licensee was notified that transit employees of the Liberty Bus Company | | in Westchester County will be going on strike. The licensee made the | | offsite notifications to assure that the contingency plans are in effect to | | deal with the strike. | | | | The NRC Resident Inspector will be notified. | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ |Power Reactor |Event Number: 37793 | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ | FACILITY: INDIAN POINT REGION: 1 |NOTIFICATION DATE: 03/01/2001| | UNIT: [] [3] [] STATE: NY |NOTIFICATION TIME: 06:33[EST]| | RXTYPE: [2] W-4-LP,[3] W-4-LP |EVENT DATE: 03/01/2001| +------------------------------------------------+EVENT TIME: 05:00[EST]| | NRC NOTIFIED BY: YOUNG |LAST UPDATE DATE: 03/01/2001| | HQ OPS OFFICER: CHAUNCEY GOULD +-----------------------------+ +------------------------------------------------+PERSON ORGANIZATION | |EMERGENCY CLASS: N/A |RICHARD CONTE R1 | |10 CFR SECTION: | | |*PRE 50.72(b)(2)(xi) OFFSITE NOTIFICATION | | | | | | | | | | | +-----+----------+-------+--------+-----------------+--------+-----------------+ |UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE | +-----+----------+-------+--------+-----------------+--------+-----------------+ | | | |3 N Y 100 Power Operation |100 Power Operation | | | | +------------------------------------------------------------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | THE LICENSEE NOTIFIED STATE AND COUNTY OFFICIALS OF A TRANSIT STRIKE IN | | WESTCHESTER COUNTY. | | | | The licensee was notified that transit employees of the Liberty Bus Company | | in Westchester County will be going on strike. The licensee made the | | offsite notifications to assure that the contingency plans are in effect to | | deal with the strike. | | | | The NRC Resident Inspector was notified. | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ |Power Reactor |Event Number: 37794 | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ | FACILITY: SOUTH TEXAS REGION: 4 |NOTIFICATION DATE: 03/01/2001| | UNIT: [] [2] [] STATE: TX |NOTIFICATION TIME: 12:55[EST]| | RXTYPE: [1] W-4-LP,[2] W-4-LP |EVENT DATE: 03/01/2001| +------------------------------------------------+EVENT TIME: 08:22[CST]| | NRC NOTIFIED BY: ROBERT BRINKLEY |LAST UPDATE DATE: 03/01/2001| | HQ OPS OFFICER: STEVE SANDIN +-----------------------------+ +------------------------------------------------+PERSON ORGANIZATION | |EMERGENCY CLASS: N/A |LINDA HOWELL R4 | |10 CFR SECTION: | | |*RPS 50.72(b)(2)(iv)(B) RPS ACTUATION - CRITICA| | |*ESF 50.72(b)(3)(iv)(A) VALID SPECIF SYS ACTUAT| | | | | | | | +-----+----------+-------+--------+-----------------+--------+-----------------+ |UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE | +-----+----------+-------+--------+-----------------+--------+-----------------+ | | | |2 M/R Y 95 Power Operation |0 Hot Standby | | | | +------------------------------------------------------------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | MANUAL REACTOR TRIP DUE TO LOSS OF OPERATING CIRCULATING WATER PUMPS | | | | "South Texas Project Unit 2 makes the following report in accordance with | | 10CFR50.72(b)(2)(iv)(B) and 50.72(b)(3)(iv)(A): | | | | "At 08:22 CST on 3/01/01, a manual Reactor Trip was initiated due to failure | | of a switchyard breaker and subsequent loss of all operating Circulating | | Water Pumps. All Control Rods fully inserted into the Reactor Core. The | | Auxiliary Feedwater system actuated on low-low Steam Generator Water Level | | and a Feedwater isolation signal occurred as expected on a trip from 95% | | power. Pressurizer heater group 'A' did not energize on low RCS pressure as | | required. Cause of the heater group to fail to energize is not known at this | | time. All four (4) Reactor Coolant pumps remain in operation and decay heat | | is currently being removed via the atmospheric steam dumps. No radiation | | above state, federal, and plant operational limits was measured by South | | Texas Project's radiation monitoring system." | | | | The licensee is presently making efforts to restore an operating Circulating | | Water Pump so as to establish Main Condenser vacuum. Three Circulating | | Water Pumps were operating at the time with the fourth out-of-service. The | | licensee has a measured 20gpd Steam Generator tube leakage. The offsite rad | | release is within allowable limits. No other safety equipment is out of | | service. The licensee informed the NRC resident inspector. | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ |General Information or Other |Event Number: 37795 | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ | REP ORG: TEXAS DEPARTMENT OF HEALTH |NOTIFICATION DATE: 03/01/2001| |LICENSEE: QC LABORATORIES, INC. |NOTIFICATION TIME: 17:00[EST]| | CITY: HOUSTON REGION: 4 |EVENT DATE: 02/19/2001| | COUNTY: HARRIS STATE: TX |EVENT TIME: 09:45[CST]| |LICENSE#: L04750 AGREEMENT: Y |LAST UPDATE DATE: 03/01/2001| | DOCKET: |+----------------------------+ | |PERSON ORGANIZATION | | |LINDA HOWELL R4 | | |JOSEPH HOLONICH NMSS | +------------------------------------------------+ | | NRC NOTIFIED BY: HELEN WATKINS (VIA FAX) | | | HQ OPS OFFICER: STEVE SANDIN | | +------------------------------------------------+ | |EMERGENCY CLASS: N/A | | |10 CFR SECTION: | | |NAGR AGREEMENT STATE | | | | | | | | | | | | | | +------------------------------------------------------------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | AGREEMENT STATE REPORT INVOLVING A MISSING NUCLEAR DENSITY GAUGE | | | | On 2/15/01 an employee of QC Laboratories, Inc. went to a jobsite and never | | returned. The police were notified and are looking for the individual and | | the company's 1997 Nissan truck. The employee was in the possession of a | | nuclear density gauge manufactured by Humbolt Scientific, Inc., model | | #HS-5001EZ, serial #3145. The gauge contains two sources; 10 millicuries | | Cs-137 (as of 7/14/97 or 10/30/98) and 40 millicuries Am-241:Be. | | | | On 3/1/01 additional information was available updating this incident. The | | gauge has been recovered. The Nissan truck with the gauge locked securely | | was parked at a drug rehab facility where the operator had checked himself | | in. | | | | Texas Incident #7718. | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ |General Information or Other |Event Number: 37796 | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ | REP ORG: TEXAS DEPARTMENT OF HEALTH |NOTIFICATION DATE: 03/01/2001| |LICENSEE: TERRACON |NOTIFICATION TIME: 17:00[EST]| | CITY: HOUSTON REGION: 4 |EVENT DATE: 02/23/2001| | COUNTY: HARRIS STATE: TX |EVENT TIME: 16:45[CST]| |LICENSE#: L05268-001 AGREEMENT: Y |LAST UPDATE DATE: 03/01/2001| | DOCKET: |+----------------------------+ | |PERSON ORGANIZATION | | |LINDA HOWELL R4 | | |JOSEPH HOLONICH NMSS | +------------------------------------------------+ | | NRC NOTIFIED BY: HELEN WATKINS (VIA FAX) | | | HQ OPS OFFICER: STEVE SANDIN | | +------------------------------------------------+ | |EMERGENCY CLASS: N/A | | |10 CFR SECTION: | | |NAGR AGREEMENT STATE | | | | | | | | | | | | | | +------------------------------------------------------------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | AGREEMENT STATE REPORT INVOLVING A STOLEN TROXLER GAUGE | | | | 2/23/01 | | | | "At approximately 4:45pm on Friday 2/23/01 a technician realized a truck | | with a gauge chained in the back had been stolen. The stolen gauge is a | | Troxler Model 3430, serial # 30170. The gauge contained two sources: 8 | | millicuries of Cs-137, serial # 7501851, and 40 millicuries of Am-241:Be, | | serial # 47-27094. [The technician] had checked the gauge our for use at a | | jobsite near 1960 Highway 59 in Humble, Texas. [The technician] is a trusted | | employee and has worked for the company for a long time. The Houston Police | | Department was notified. | | | | 3/1/01 | | | | "The truck and gauge were recovered and returned to the Licensee on 2/28/01. | | The gauge was still locked in the back of the truck; it was undamaged. A New | | Orleans, Louisiana resident noticed the truck parked in front of their | | residence and called the New Orleans Police Department. The Houston Police | | Department was notified and arranged the recovery. | | | | "The Licensee will submit a written report providing additional details on | | 3/2/01." | | | | Texas Incident #7726. | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ |Power Reactor |Event Number: 37797 | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ | FACILITY: KEWAUNEE REGION: 3 |NOTIFICATION DATE: 03/01/2001| | UNIT: [1] [] [] STATE: WI |NOTIFICATION TIME: 18:37[EST]| | RXTYPE: [1] W-2-LP |EVENT DATE: 03/01/2001| +------------------------------------------------+EVENT TIME: 09:55[CST]| | NRC NOTIFIED BY: KEVIN HUJET |LAST UPDATE DATE: 03/01/2001| | HQ OPS OFFICER: STEVE SANDIN +-----------------------------+ +------------------------------------------------+PERSON ORGANIZATION | |EMERGENCY CLASS: N/A |ANTON VEGEL R3 | |10 CFR SECTION: | | |*COM 50.72(b)(3)(xiii) LOSS COMM/ASMT/RESPONSE| | | | | | | | | | | +-----+----------+-------+--------+-----------------+--------+-----------------+ |UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE | +-----+----------+-------+--------+-----------------+--------+-----------------+ |1 N Y 96 Power Operation |96 Power Operation | | | | | | | +------------------------------------------------------------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | ALERT NOTIFICATION SYSTEM DISCOVERED INOPERABLE | | | | "At 0955, KNPP was notified by the Kewaunee County Sheriffs Office of a | | disconnected cable which supplies the siren encoder for the Alert | | Notification System. Subsequent investigation identified that the | | transmitter was removed during remodeling, disabling the system from being | | activated by the Kewaunee County Dispatch Office, potentially as early as | | Monday, 2/26/01. Normal siren activation would be accomplished from the | | Algoma Emergency Operations Center, but the Kewaunee Dispatch location would | | be used in the event of a fast breaking incident. It is believed that | | processes in place would have lead the Kewaunee Dispatch to pursue alternate | | methods of activating the sirens, however, it is not clear that this would | | have been performed in a timely manner. Compensatory measures have been | | established for the Kewaunee Dispatch/Sheriff to notify the Kewaunee | | Emergency Director of the need to activate the sirens. The Emergency | | Director has the capability to activate the sirens remotely and will | | maintain this activation function manned until the equipment issues at the | | Kewaunee Dispatch have been resolved." | | | | The licensee informed local authorities and the NRC resident inspector. | +------------------------------------------------------------------------------+
Page Last Reviewed/Updated Thursday, March 25, 2021
Page Last Reviewed/Updated Thursday, March 25, 2021