Event Notification Report for May 10, 1999

                    U.S. Nuclear Regulatory Commission
                              Operations Center

                              Event Reports For
                           05/07/1999 - 05/10/1999

                              ** EVENT NUMBERS **

35612  35621  35634  35682  35688  35689  35690  35692  35693  35694  35695 


+------------------------------------------------------------------------------+
|General Information or Other                     |Event Number:   35612       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG:  MA DEPT OF PUBLIC HEALTH RCP         |NOTIFICATION DATE: 04/21/1999|
|LICENSEE:  AEA TECHNOLOGIES QSA, INC            |NOTIFICATION TIME: 15:00[EDT]|
|    CITY:  BURLINGTON               REGION:  1  |EVENT DATE:        04/21/1999|
|  COUNTY:                            STATE:  MA |EVENT TIME:        14:00[EDT]|
|LICENSE#:                        AGREEMENT:  Y  |LAST UPDATE DATE:  05/07/1999|
|  DOCKET:                                       |+----------------------------+
|                                                |PERSON          ORGANIZATION |
|                                                |MOHAMED SHANBAKY     R1      |
|                                                |FREDERICK COMBS      NMSS    |
+------------------------------------------------+JOSEPH GIITTER       IRO     |
| NRC NOTIFIED BY:  KEN TRAEGDE                  |DONNA MARIE PEREZ    IP      |
|  HQ OPS OFFICER:  DICK JOLLIFFE                |LEN WERT             R2      |
+------------------------------------------------+DALE POWERS          R4      |
|EMERGENCY CLASS:          N/A                   |                             |
|10 CFR SECTION:                                 |                             |
|NAGR                     AGREEMENT STATE        |                             |
|NOCM                     COMM ASST BRIEF        |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| - SHIPMENT OF 8 Ir-192 SOURCES (866 CURIES TOTAL) FROM BURLINGTON, MA,       |
| OVERDUE IN MEXICO -                                                          |
|                                                                              |
| At 1500 EDT on 04/21/99, Ken Traegde of the Massachusetts Department of      |
| Public Health Radiation Control Program (RCP) located in Boston,             |
| Massachusetts, reported that on 04/16/99, AEA Technology QSA, Inc., located  |
| in Burlington, Massachusetts, shipped a Model-855 source changer loaded with |
| eight Iridium-192 sources (totaling 866 curies) via Federal Express to       |
| Vicont S.A. De C.V. located in Toluca, Mexico.  The undamaged package had a  |
| transport index of 1.4 (normal readings of 1.4 mR/hour at 1 meter and 55     |
| mR/hour at the surface) at the time of shipment.                             |
|                                                                              |
| The shipment was scheduled to arrive in Mexico on 04/17/99.  As of 1400 EDT  |
| on 04/21/99, the recipient (Vicont S.A. De C.V.) had received the shipping   |
| papers but not the container.  The shipper and Federal Express have launched |
| a full search for the package.  The Federal Express Hazardous Material       |
| Investigation Team has conducted a physical search of Express Depots in      |
| Boston, Memphis, Los Angeles, and Mexico.                                    |
|                                                                              |
| The license numbers are:  SU-1485, 12-8361, 52-0243, 54-0237, and 58-0242.   |
|                                                                              |
| The NRC operations officer notified the Department of Transportation via the |
| National Response Center (Gauthier); Report number 481132.                   |
|                                                                              |
| (Contact the NRC operations officer for applicable telephone numbers.)       |
|                                                                              |
| *********************************** UPDATE AT 1345 ON 04/22/99 BY JONES      |
| ***********************************                                          |
|                                                                              |
| The NRC entered the Monitoring Phase of Normal Mode at 1345 on 04/22/99.     |
| The NRC operations officer notified the R1DO (Shanbaky), Region 1 (Miller),  |
| IRO (Congel and Giitter), NMSS (Paperiello), RCT (Weinstein), OPA (Gagner),  |
| EDO's office (Charleen Raddatz), and Chairman's office (Holian).  The RCT    |
| notified the Federal Emergency Management Agency (Dan Rishe), Department of  |
| Energy (Thomas Yates), Department of Agriculture (Bob Conley), Department of |
| Health and Human Services (James Raab), and Environmental Protection Agency  |
| and Department of Transportation via the National Response Center (Ms.       |
| Reddy).                                                                      |
|                                                                              |
| *********************************** UPDATE AT 1600 ON 04/22/99 BY JONES      |
| ***********************************                                          |
|                                                                              |
| A Commissioner's Assistants Briefing was conducted at 1600 on 04/22/99.  The |
| following notifications were made (* office did not participate):  IRO (Joe  |
| Giitter and Eric Weinstein), Chairman Jackson (Dan Gillen), Commissioner     |
| Dicus (Joel Lubenau), Commissioner Diaz (Patrick Castleman), Commissioner    |
| McGaffigan (Janet Schlueter), Commissioner Merrifield (JohnThoma), EDO (*Dan |
| Martin), DEDE (*Jocelyn Mitchell), NMSS (Don Cool and Carl Paperiello), NMSS |
| EO (Fred Combs), R1DO (Mohamed Shanbaky), OPA (Joe Gilland), CAO (Thomas     |
| Madden), SECY (Andrew Bates), OSP (Paul Lohaus), OIP (Ron Hauber), Region 1  |
| (Felicia Hinson and Jim Wiggins, etc), and Region 2 (Doug Collins, Chuck     |
| Hosey, and Dick Woodruff).  The briefer was Fred Combs of NMSS.              |
|                                                                              |
| At 1610, the NRC operations officer played a tape of briefing for EDO (Dan   |
| Martin) and DEDE (Jocelyn Mitchell).                                         |
|                                                                              |
| ****************************** UPDATE AT 1230 ON 04/23/99 BY TROCINE AND     |
| JONES ******************************                                         |
|                                                                              |
| A conference call was conducted at 1230 on 04/23/99 to update the status of  |
| this event.  The following NRC offices participated (among others):  IRO     |
| (Himes), NMSS (Brach, Combs, and Cook), Region 1 (Lloyd), Region 2 (Collins  |
| and Woodruff), Region 4 (Andrews), OPA (Hayden), OIP (Lieberman), OSP        |
| (Lohaus), and EDO (Raddatz).  In addition, the following agencies            |
| participated:  Department of Transportation (Rick Boyle), Massachusetts      |
| Department of Public Health RCP (Ken Traegde), Federal Express (Scott Mugno, |
| Pat Oppenheimer, and Roy Parker), State of Tennessee (Alan Grewe), Tennessee |
| Division of Radiation Health (Eddy Nanney), AEA Technology QSA, Inc. (Eric   |
| Okvist), and Environmental Protection Agency located in Atlanta (Paul        |
| Wagner).                                                                     |
|                                                                              |
| During this conference call, representatives of Federal Express reported     |
| that they are confident that the shipment of eight Iridium-192 sources left  |
| Boston.  They issued an 'all-points' search order, faxed a description to    |
| all 'logical' locations, and conducted repeat physical searches in Memphis,  |
| Boston, and Mexico, all without locating the shipment to date.  (The Los     |
| Angeles depot was not searched as had been reported on 04/21/99.)            |
| Massachusetts and Tennessee health authorities conducted radiological        |
| surveys in Boston and Memphis on 04/22/99 with negative results.             |
|                                                                              |
| Rick Boyle of the Department of Transportation notified the competent        |
| authority in Mexico, and Federal Express requested a detailed search of the  |
| Customs facilities in Mexico City.                                           |
|                                                                              |
| The next conference call is scheduled for 1230 EDT on Wednesday, 04/28/99.   |
|                                                                              |
| ************************* UPDATE AT 1333 ON 04/26/99 FROM TRAEGDE TO TROCINE |
| *************************                                                    |
|                                                                              |
| At 0619 EDT on 04/26/99, Federal Express confirmed that the serial number on |
| a Model-855, Type-B package found at the Stansted Airport (located outside   |
| of London, England) matched the serial number for the missing package        |
| containing the eight Iridium-192 sources.  The Massachusetts Department of   |
| Public Health RCP was informed of this discovery by AEA Technology QSA,      |
| Inc., at 0933 EDT on 04/26/99.  The package was reported to be intact and    |
| undisturbed.  The carrier (Federal Express) contacted the shipper (AEA       |
| Technology QSA, Inc.), and the shipper requested that the package be         |
| forwarded to its intended destination.  Accordingly, the package will be     |
| shipped from Stansted Airport to Toluca, Mexico, via Memphis, Tennessee.     |
| Federal Express informed the Massachusetts Department of Public Health RCP   |
| that the package is expected to arrive in Memphis, Tennessee, by tomorrow    |
| morning (04/27/99).                                                          |
|                                                                              |
| The Massachusetts Department of Public Health RCP notified NRC Region 1      |
| (Duncan White).  The NRC Operations Officer notified the R1DO (Anderson);    |
| R2DO (Wert); R4DO (Graves); NMSS (Combs); IRO (Giitter, Miller, and Congel); |
| RCT (Bailey).                                                                |
|                                                                              |
| *********************************** UPDATE AT 1600 ON 04/26/99 BY TROCINE    |
| ***********************************                                          |
|                                                                              |
| A conference call was conducted at 1600 on 04/26/99 to update the status of  |
| this event.  The following NRC offices participated (*office did not         |
| participate):  IRO (Giitter), RCT (Bailey), NMSS (Brach and Cool), Region 1  |
| (Kinneman), Region 2 (Hosey), Region 4 (*Graves), Region 1 Public Affairs    |
| (*Screnci and *Sheehan), HQ OPA (Beecher), OIP (Lieberman), OSP (Bolling and |
| Lohaus), and EDO (Raddatz).  In addition, the following agencies             |
| participated:  Massachusetts Department of Public Health RCP (Ken Traegde),  |
| State of Tennessee (Alan Grewe and Mike Mobley), and Tennessee Division of   |
| Radiation Health (Eddy Nanney).                                              |
|                                                                              |
| Based upon the information discussed during this conference call (reference  |
| the 1333 04/26/99 update above), the NRC exited the Monitoring Phase of      |
| Normal Mode at 1615 on 04/26/99.                                             |
|                                                                              |
| The NRC operations officer notified the IRO (Giitter, Miller, and Congel);   |
| RCT (Bailey); NMSS EO (Cool); NMSS (Brach); Region 1 (Kinneman); Region 2    |
| (Hosey); R1DO (Anderson); R2DO (Wert); R4DO (Graves); OPA (Beecher); OIP     |
| (Lieberman); OSP (Bolling and Lohaus); and EDO (Raddatz).  The RCT notified  |
| the Federal Emergency Management Agency (Butch Steindurf), Department of     |
| Energy (Kevin Moore), Department of Agriculture (George Bickerton),          |
| Department of Health and Human Services (E.K. Gray), and Environmental       |
| Protection Agency and Department of Transportation via the National Response |
| Center (Gauthier).                                                           |
|                                                                              |
| ****  UPDATE AT 1505 ON 04/29/99 FROM DAKUBU TAKEN BY WEAVER  ****           |
|                                                                              |
| Dr. Dakubu of the Massachusetts Department of Public Health Radiation        |
| Control Program informed the NRC Operations Center that the sources arrived  |
| safely at their intended destination in Mexico on 04/28/98.  The NRC         |
| Operations Officer informed the R1DO (Cliff Anderson) and NMSS EO (Larry     |
| Camper).                                                                     |
|                                                                              |
| **** UPDATE AT 0900 ON 04/30/99 BY JOLLIFFE ****                             |
|                                                                              |
| The sources arrived in Mexico on 04/28/99 (not 04/28/98, as specified        |
| above).                                                                      |
|                                                                              |
| **** UPDATE AT 1209 ON 05/07/99 BY TROCINE ****                              |
|                                                                              |
| This event has been updated to correct the notifications made to other       |
| agencies.                                                                    |
+------------------------------------------------------------------------------+

!!!!!!!!! THIS EVENT HAS BEEN RETRACTED. THIS EVENT HAS BEEN RETRACTED  !!!!!!!
+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   35621       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: CRYSTAL RIVER            REGION:  2  |NOTIFICATION DATE: 04/22/1999|
|    UNIT:  [3] [] []                 STATE:  FL |NOTIFICATION TIME: 19:02[EDT]|
|   RXTYPE: [3] B&W-L-LP                         |EVENT DATE:        04/22/1999|
+------------------------------------------------+EVENT TIME:        18:08[EDT]|
| NRC NOTIFIED BY:  BILL BANDHAUGER              |LAST UPDATE DATE:  05/07/1999|
|  HQ OPS OFFICER:  FANGIE JONES                 +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |LEN WERT             R2      |
|10 CFR SECTION:                                 |                             |
|AOUT 50.72(b)(1)(ii)(B)  OUTSIDE DESIGN BASIS   |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|3     N          Y       100      Power Operation  |100      Power Operation  |
|                                                   |                          |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| POSSIBLE OVERLOAD OF ESF TRANSFORMER IN AN ABNORMAL OPERATING PROCEDURE      |
| FOUND                                                                        |
|                                                                              |
| While investigating a previous Licensee Event Report concerned with backfeed |
| the following was discovered:                                                |
| "During a scenario involving a Loss of Off-Site Power resulting from a loss  |
| of the BEST and Startup transformers, the Crystal River Unit 3 abnormal      |
| operating procedures could have caused an overload of the safety-related     |
| Engineered Safeguards 4160V to 480V transformer.  Assuming a single failure  |
| of the 'B' side diesel generator, power could have been unavailable to both  |
| trains of 480V Engineered safeguards loads.  This condition is considered    |
| reportable per 10CFR50.72(b)(l)(ii)(B) and 10CFR50.73(a)(2)(ii)(B) as a      |
| condition outside of the design basis of the plant.  Loads have been         |
| identified which can be administratively maintained off during this scenario |
| to avoid the overload condition, and therefore, the transformer is           |
| operable."                                                                   |
|                                                                              |
| This condition is under investigation and further actions will be            |
| forthcoming.                                                                 |
|                                                                              |
| The licensee intends to notify the NRC Resident Inspector.                   |
|                                                                              |
| **** UPDATE ON 05/07/99 AT 2311 BY RAWLS TO GOULD ****  EVENT RETRACTION     |
|                                                                              |
| THE LICENSEE AND ABB POWER T&D CO, INC HAVE EVALUATED POSSIBLE OVERLOAD      |
| CONDITIONS OF THE "A" 4160/480V TRANSFORMER DURING A LOSS OF OFFSITE POWER   |
| WITH THE LOSS OF THE "B" BATTERY SCENARIO.  THE RESULTS OF THE EVALUATIONS   |
| SHOW THAT THE CLASS 1E TRANSFORMER AND COMPONENTS WILL PERFORM THEIR         |
| DESIGNED FUNCTION FOR LONGER THAN 30 DAYS WITHOUT FAILURE.  THE TRANSFORMER  |
| WILL SURVIVE LONGER THAN ONE YEAR UNDER THE IDENTIFIED LOAD CONDITIONS BASED |
| ON A REVIEW OF ANSI/IEEE C57.96.  IN ADDITION, THE NON-CLASS 1E CROSSTIES    |
| CIRCUITS TO THE RX AUX BUS 3A/3B ARE LICENSING BASIS REQUIREMENTS AND ARE    |
| NOT DESIGN BASIS REQUIREMENTS.  THE LICENSEE IS THEREFORE RETRACTING THIS    |
| EVENT.                                                                       |
|                                                                              |
| THE LICENSEE INFORMED THE NRC RESIDENT INSPECTOR.  THE NRC OPERATIONS        |
| OFFICER NOTIFIED THE R2DO CHRIS CHRISTENSEN.                                 |
+------------------------------------------------------------------------------+

!!!!!!!!! THIS EVENT HAS BEEN RETRACTED. THIS EVENT HAS BEEN RETRACTED  !!!!!!!
+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   35634       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: SURRY                    REGION:  2  |NOTIFICATION DATE: 04/26/1999|
|    UNIT:  [] [2] []                 STATE:  VA |NOTIFICATION TIME: 11:13[EDT]|
|   RXTYPE: [1] W-3-LP,[2] W-3-LP                |EVENT DATE:        04/26/1999|
+------------------------------------------------+EVENT TIME:        08:37[EDT]|
| NRC NOTIFIED BY:  HILBERT-SEMMES               |LAST UPDATE DATE:  05/07/1999|
|  HQ OPS OFFICER:  CHAUNCEY GOULD               +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |LEN WERT             R2      |
|10 CFR SECTION:                                 |                             |
|AESF 50.72(b)(2)(ii)     ESF ACTUATION          |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|                                                   |                          |
|2     N          N       0        Refueling        |0        Refueling        |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| THE PLANT RECEIVED A TRAIN "B" HIGH CONSEQUENCE-LIMITING SAFEGUARDS (CLS)    |
| SIGNAL.                                                                      |
|                                                                              |
| THIS OCCURRED WHEN AN ELECTRICIAN LIFTED A LEAD WHILE REPLACING RELAY        |
| "2-CLS-RLY-1B1" IN THE "B" TRAIN HIGH CLS SYSTEM.  ONE CONTAINMENT TRIP      |
| VALVE FOR THE CONTAINMENT PARTICULATE AND GAS RADIATION MONITORS             |
| REPOSITIONED (CLOSED), AND THE PARTICULATE AND GAS RADIATION MONITOR PUMP    |
| DE-ENERGIZED.   A SAFETY INJECTION SIGNAL WAS NOT RECEIVED AS IT WAS         |
| PROPERLY DEFEATED IN ACCORDANCE WITH STATION PROCEDURES.  THE ELECTRICIANS   |
| VERIFIED THAT THE HIGH CLS SYSTEM WAS DE-ENERGIZED AS THEY WOULD EXPECT      |
| PRIOR TO PERFORMING WORK TO PREVENT A SPURIOUS ACTUATION.  THE LICENSEE IS   |
| INVESTIGATING THE CAUSE AND THE REQUIRED CORRECTIVE ACTIONS.  THE HIGH CLS   |
| SIGNAL WAS RESET SINCE THE 2/4 CONTAINMENT PRESSURE < 14.2 PSIA MATRIX WAS   |
| MET DUE TO THE ACCURACY OF THE GAUGES.  THE TRIP VALVE WAS PLACED IN THE     |
| PRE-EVENT CONDITION (OPEN), AND THE RADIATION MONITOR PUMP WAS RE-ENERGIZED  |
| AND RESTARTED.  CORE OFF LOAD WAS NOT IN PROGRESS AT THE TIME OF THIS        |
| EVENT.                                                                       |
|                                                                              |
| THE NRC RESIDENT INSPECTOR WAS NOTIFIED BY THE LICENSEE.                     |
|                                                                              |
| ***************** UPDATE AT 1102 ON 05/07/99 FROM LISA HILLBERT-SEMMES TO    |
| TROCINE ******************                                                   |
|                                                                              |
| The licensee is retracting this event notification.                          |
|                                                                              |
| The following text is a portion of a facsimile received from the licensee:   |
|                                                                              |
| "At 1113 on April 26, 1999, a 4-hour Non-Emergency Notification was made in  |
| accordance with 10CFR50.72(b)(2)(ii) due to an ESF actuation.  An            |
| inadvertent Unit 2 High Consequence Limiting Safeguards (CLS) signal for     |
| Train 'B' was caused by maintenance activities when replacing a High CLS     |
| relay (#2-CLS-RLY-1B1) with Unit 2 in Refueling Shutdown.  The High CLS      |
| signal only initiated the closure of containment trip valve #2-RM-TV-200B,   |
| which caused the sample pump, #2-RM-P-200, for the containment particulate   |
| and gaseous radiation monitors to de-energize."                              |
|                                                                              |
| "NUREG-1022, Event Reporting Guidelines 10CFR50.72 and 50.73, states that    |
| 'The Commission is interested both in events where an ESF was needed to      |
| mitigate the consequences (whether or not the equipment performed properly)  |
| and events where an ESF actuated unnecessarily.... Usually, the staff would  |
| not consider this to include single component actuations because single      |
| components of complex systems, by themselves, usually do not mitigate the    |
| consequences of significant events.'"                                        |
|                                                                              |
| "Based on further review of this event and guidance provided in NUREG-1022,  |
| it was determined that this event was not reportable as the High CLS signal  |
| was invalid and resulted in the actuation of only one component which did    |
| not mitigate the consequences of the event."                                 |
|                                                                              |
| "This notification is made to retract the report made on April 26, 1999,     |
| based on the above discussion."                                              |
|                                                                              |
| The licensee notified the NRC Resident Inspector.  The NRC Operations        |
| Officer notified the R2DO Chris Christensen.                                 |
+------------------------------------------------------------------------------+

!!!!!!!!! THIS EVENT HAS BEEN RETRACTED. THIS EVENT HAS BEEN RETRACTED  !!!!!!!
+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   35682       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: SUMMER                   REGION:  2  |NOTIFICATION DATE: 05/06/1999|
|    UNIT:  [1] [] []                 STATE:  SC |NOTIFICATION TIME: 07:34[EDT]|
|   RXTYPE: [1] W-3-LP                           |EVENT DATE:        05/06/1999|
+------------------------------------------------+EVENT TIME:        06:45[EDT]|
| NRC NOTIFIED BY:  JIM PROPER                   |LAST UPDATE DATE:  05/07/1999|
|  HQ OPS OFFICER:  LEIGH TROCINE                +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |CHRIS CHRISTENSEN    R2      |
|10 CFR SECTION:                                 |                             |
|DDDD 73.71               UNSPECIFIED PARAGRAPH  |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          N       0        Cold Shutdown    |0        Cold Shutdown    |
|                                                   |                          |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| ATTEMPTED INTRODUCTION OF CONTRABAND INTO THE PROTECTED AREA  (1-hour report |
| in accordance with 10CFR73.71, Appendix G)                                   |
|                                                                              |
| The licensee reported an attempted introduction of contraband into the       |
| protected area.  Immediate compensatory measurements were taken upon         |
| discovery.  (Contact the NRC Operations Officer for additional details and   |
| for a site contact telephone number.)                                        |
|                                                                              |
| The licensee notified the NRC Resident Inspector.                            |
|                                                                              |
| **** UPDATE AT 1314 ON 05/07/99 FROM RICE TO GOULD ****  EVENT RETRACTION    |
|                                                                              |
| THE LICENSEE HAS INVESTIGATED THIS EVENT FURTHER AND HAS DETERMINED THAT THE |
| EVENT IS NOT REPORTABLE SINCE THERE WAS NO DELIBERATE INTENT TO INTRODUCE    |
| CONTRABAND INTO THE PROTECTED AREA.  A BACKGROUND CHECK CONFIRMED NO         |
| CRIMINAL HISTORY FOR THE INDIVIDUAL.                                         |
|                                                                              |
| THE LICENSEE INFORMED THE NRC RESIDENT INSPECTOR.                            |
|                                                                              |
| THE NRC OPERATIONS OFFICER NOTIFIED THE R2DO CHRIS CHRISTENSEN.              |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Other Nuclear Material                           |Event Number:   35688       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG:  USAF RADIOISOTOPE COMMITTEE          |NOTIFICATION DATE: 05/07/1999|
|LICENSEE:  USAF RADIOISOTOPE COMMITTEE          |NOTIFICATION TIME: 10:45[EDT]|
|    CITY:  Sumptor                  REGION:  2  |EVENT DATE:        05/07/1999|
|  COUNTY:                            STATE:  SC |EVENT TIME:        09:38[EDT]|
|LICENSE#:  42-23539-01AF         AGREEMENT:  Y  |LAST UPDATE DATE:  05/07/1999|
|  DOCKET:  03028641                             |+----------------------------+
|                                                |PERSON          ORGANIZATION |
|                                                |CHRIS CHRISTENSEN    R2      |
|                                                |BILL JONES           R4      |
+------------------------------------------------+DON COOL             NMSS    |
| NRC NOTIFIED BY:  MAJOR JAMES HICKS            |FRANK CONGEL         IRO     |
|  HQ OPS OFFICER:  LEIGH TROCINE                |                             |
+------------------------------------------------+                             |
|EMERGENCY CLASS:          N/A                   |                             |
|10 CFR SECTION:                                 |                             |
|BAB1 20.2201(a)(1)(i)    LOST/STOLEN LNM>1000X  |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| DISCOVERY OF A MISSING CHEMICAL AGENT MONITOR CONTAINING 15 mCi OF NICKEL-63 |
| FROM SHAW AIR FORCE BASE LOCATED IN SUMPTOR, SOUTH CAROLINA                  |
|                                                                              |
| At 0938 on 05/07/99, Shaw Air Force Base (AFB) located in Sumptor, South     |
| Carolina, notified the U.S. Air Force Radioisotope Committee located at      |
| Bolling AFB located in Washington D.C. of a missing chemical agent monitor   |
| (CAM) containing a 15-mCi nickel-63 source.                                  |
|                                                                              |
| On 04/27/99, the base radiation safety officer (RSO) at Shaw AFB conducted   |
| an inventory of CAMs located in building #1981.  The correct number of CAMs  |
| were there, but one had the wrong serial number.  Examination of previous    |
| inventories shows one CAM with a different serial number.  The building had  |
| been searched with no success.  The 20CES/CEX RSO has no explanation for the |
| different serial number on one CAM or where the correct CAM may be located.  |
|                                                                              |
|                                                                              |
| It is suspected that the CAM may have been exchanged with another Air Force  |
| Unit or may have been sent off for calibration.  At this time, the U.S. Air  |
| Force Radioisotope Committee believes that the CAM is still in Air Force     |
| possession.  Past shipping records will be researched, and calibration labs  |
| that serve Shaw AFB will be notified.  The completion time for these actions |
| is currently estimated to be 06/07/99.                                       |
|                                                                              |
| Call the NRC Operations Officer for a licensee contact telephone number.     |
|                                                                              |
| The licensee plans to notify the NRC Region 4 office and plans to issue a    |
| 30-day written report.                                                       |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   35689       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: HATCH                    REGION:  2  |NOTIFICATION DATE: 05/07/1999|
|    UNIT:  [1] [] []                 STATE:  GA |NOTIFICATION TIME: 11:09[EDT]|
|   RXTYPE: [1] GE-4,[2] GE-4                    |EVENT DATE:        05/07/1999|
+------------------------------------------------+EVENT TIME:        08:21[EDT]|
| NRC NOTIFIED BY:  EDWEN URQUHART               |LAST UPDATE DATE:  05/07/1999|
|  HQ OPS OFFICER:  BOB STRANSKY                 +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |CHRIS CHRISTENSEN    R2      |
|10 CFR SECTION:                                 |                             |
|ARPS 50.72(b)(2)(ii)     RPS ACTUATION          |                             |
|AESF 50.72(b)(2)(ii)     ESF ACTUATION          |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     A/R        Y       53       Power Operation  |0        Hot Shutdown     |
|                                                   |                          |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| AUTOMATIC REACTOR SCRAM DUE TO LOSS OF EHC PRESSURE                          |
|                                                                              |
| An automatic reactor scram occurred due to high reactor vessel pressure      |
| (1080 psig) after the main turbine stop and control valves drifted closed.   |
| All control rods inserted following the scram, and all systems functioned as |
| expected.  Neither the HPCI nor RCIC systems started, as reactor vessel      |
| water level did not decrease to the automatic actuation setpoint.  The       |
| licensee reported that an operator inadvertently isolated the main turbine   |
| electrohydraulic control (EHC) system oil supply while tagging out the       |
| standby EHC oil pump, causing the turbine stop and control valves to drift   |
| closed.                                                                      |
|                                                                              |
| The NRC Resident Inspector has been informed of this notification by the     |
| licensee.                                                                    |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   35690       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: NINE MILE POINT          REGION:  1  |NOTIFICATION DATE: 05/07/1999|
|    UNIT:  [] [2] []                 STATE:  NY |NOTIFICATION TIME: 12:41[EDT]|
|   RXTYPE: [1] GE-2,[2] GE-5                    |EVENT DATE:        05/07/1999|
+------------------------------------------------+EVENT TIME:        09:50[EDT]|
| NRC NOTIFIED BY:  LANGE                        |LAST UPDATE DATE:  05/07/1999|
|  HQ OPS OFFICER:  CHAUNCEY GOULD               +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |JAMES LINVILLE       R1      |
|10 CFR SECTION:                                 |                             |
|AIND 50.72(b)(2)(iii)(D) ACCIDENT MITIGATION    |                             |
|NLCO                     TECH SPEC LCO A/S      |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|                                                   |                          |
|2     N          Y       59       Power Operation  |59       Power Operation  |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| THE LICENSEE DECLARED THE HIGH PRESSURE CORE SPRAY (HPCS) SYSTEM INOPERABLE  |
| AND ENTERED A 14 DAY LCO ACTION STATEMENT.                                   |
|                                                                              |
| THE HPCS SYSTEM FAILED TO MEET THE CHANNEL CHECK CRITERIA AND WAS DECLARED   |
| INOPERABLE, BUT FUNCTIONAL.  TWO TRIP UNITS WERE FOUND NOT TO BE WITHIN THE  |
| 13 INCHES LIMIT FOR LEVEL INITIATION INSTRUMENTATION (THEY MEASURED 15       |
| INCHES).  A WORK ORDER HAS BEEN GENERATED TO CORRECT THE PROBLEM BEFORE THE  |
| TIME CLOCK EXPIRES FOR THE LCO ACTION STATEMENT.  THE REACTOR IS CURRENTLY   |
| IN SINGLE LOOP OPERATION AT 59% POWER.                                       |
|                                                                              |
| THE LICENSEE INFORMED THE NRC RESIDENT INSPECTOR.                            |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Fuel Cycle Facility                              |Event Number:   35692       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: PADUCAH GASEOUS DIFFUSION PLANT      |NOTIFICATION DATE: 05/07/1999|
|   RXTYPE: URANIUM ENRICHMENT FACILITY          |NOTIFICATION TIME: 23:00[EDT]|
| COMMENTS: 2 DEMOCRACY CENTER                   |EVENT DATE:        05/07/1999|
|           6903 ROCKLEDGE DRIVE                 |EVENT TIME:        13:45[CDT]|
|           BETHESDA, MD 20817    (301)564-3200  |LAST UPDATE DATE:  05/07/1999|
|    CITY:  PADUCAH                  REGION:  3  +-----------------------------+
|  COUNTY:  McCRACKEN                 STATE:  KY |PERSON          ORGANIZATION |
|LICENSE#:  GDP-1                 AGREEMENT:  Y  |MONTE PHILLIPS       R3      |
|  DOCKET:  0707001                              |JOHN GREEVES         NMSS    |
+------------------------------------------------+                             |
| NRC NOTIFIED BY:  BEASLEY                      |                             |
|  HQ OPS OFFICER:  CHAUNCEY GOULD               |                             |
+------------------------------------------------+                             |
|EMERGENCY CLASS:          N/A                   |                             |
|10 CFR SECTION:                                 |                             |
|NCFR                     NON CFR REPORT REQMNT  |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| PRIMARY CONDENSATE ALARM RECEIVED AT THE C-337-A FACILITY.                   |
|                                                                              |
| A PRIMARY CONDENSATE ALARM WAS RECEIVED ON THE C-337-A #1 EAST AUTOCLAVE     |
| WATER INVENTORY CONTROL (WIC) SYSTEM.  THE WIC SYSTEM IS REQUIRED TO BE      |
| OPERABLE WHILE HEATING IN MODE 5 ACCORDING TO TECHNICAL SAFETY REQUIREMENT   |
| #2.2.4.2.  THE AUTOCLAVE WAS CHECKED ACCORDING TO THE ALARM RESPONSE         |
| PROCEDURE, AND SUBSEQUENTLY REMOVED FROM SERVICE AND DECLARED INOPERABLE.    |
| TROUBLESHOOTING WAS INITIATED AND IS CONTINUING IN ORDER TO DETERMINE THE    |
| REASON FOR THE ALARM.                                                        |
|                                                                              |
| THE NRC RESIDENT INSPECTOR WAS INFORMED.                                     |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|General Information or Other                     |Event Number:   35693       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG:  COGEMA MINING, INC                   |NOTIFICATION DATE: 05/08/1999|
|LICENSEE:  COGEMA MINING, INC                   |NOTIFICATION TIME: 11:32[EDT]|
|    CITY:                           REGION:  4  |EVENT DATE:        05/08/1999|
|  COUNTY:  CAMPBELL                  STATE:  WY |EVENT TIME:        01:30[MDT]|
|LICENSE#:  SUA-1341              AGREEMENT:  N  |LAST UPDATE DATE:  05/08/1999|
|  DOCKET:                                       |+----------------------------+
|                                                |PERSON          ORGANIZATION |
|                                                |BILL JONES           R4      |
|                                                |JOHN GREEVES         NMSS    |
+------------------------------------------------+MORRIS               DOE     |
| NRC NOTIFIED BY:  JOHN VASELIN, RSO            |ALLRED               HHS     |
|  HQ OPS OFFICER:  DICK JOLLIFFE                |CANUPP               FEMA    |
+------------------------------------------------+MASON                EPA     |
|EMERGENCY CLASS:          N/A                   |                             |
|10 CFR SECTION:                                 |                             |
|NONR                     OTHER UNSPEC REQMNT    |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| - 15,000 GALLON MINING INJECTION SOLUTION SPILL -                            |
|                                                                              |
| A WELLFIELD MINING INJECTION SOLUTION ("BARREN LIXIVIANT") SPILL OCCURRED AT |
| THE IN-SITU LEACH INJECTION MINE UNIT 5 (#5BD47-1) AT THE CHRISTENSEN MINE   |
| IN CAMPBELL COUNTY, WY.                                                      |
|                                                                              |
| THE SPILL, WHICH IS ESTIMATED TO BE 15,000 GALLONS WITH A URANIUM            |
| CONCENTRATION OF                                                             |
| 1.0 mg/I OF U3O8,  IS THE RESULT OF A PLUMBING FAILURE AT THE INJECTION WELL |
| HEAD.  THE SPILL WAS REPORTED TO THE NRC SINCE IT IS GREATER THAN 10,000     |
| GALLONS, WHICH IS CONSIDERED SIGNIFICANT FROM AN OPERATIONS STANDPOINT.      |
|                                                                              |
| THE SOLUTION SPILLED ONTO THE NEARBY SOIL AND IT IS ANTICIPATED THAT THE     |
| SPILL DOES NOT POSE A HEALTH OR ENVIRONMENTAL HAZARD DUE TO ITS LOW          |
| CONCENTRATION OF URANIUM.  THERE ARE NO RESIDENTS  WITHIN ONE MILE OF THE    |
| SPILL AND THE NEAREST TOWN IS FURTHER THAN 15 MILES AWAY.                    |
|                                                                              |
| THE INJECTION WELL WAS SHUT DOWN AND THE SPILL WAS STOPPED.  THE WELL WILL   |
| NOT BE USED UNTIL THE PLUMBING IS REPAIRED.  A SOIL SAMPLE HAS BEEN          |
| COLLECTED AT THE SPILL LOCATION AND WILL BE ANALYZED FOR THE PRESENCE OF     |
| Ra-226 TO DETERMINE IF SOIL CLEAN-UP IS NECESSARY.                           |
|                                                                              |
| THE RADIATION SAFETY OFFICER (RSO) PLANS TO NOTIFY THE WYOMING STATE         |
| DEPARTMENT OF ENVIRONMENTAL QUALITY AND PLANS TO SUBMIT A WRITTEN REPORT TO  |
| THE NRC WITHIN 7 DAYS.                                                       |
|                                                                              |
| HOO NOTE: SEE SIMILAR EVENTS #35524, #35542 AND #35593.                      |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   35694       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: MONTICELLO               REGION:  3  |NOTIFICATION DATE: 05/08/1999|
|    UNIT:  [1] [] []                 STATE:  MN |NOTIFICATION TIME: 14:58[EDT]|
|   RXTYPE: [1] GE-3                             |EVENT DATE:        05/08/1999|
+------------------------------------------------+EVENT TIME:        13:35[CDT]|
| NRC NOTIFIED BY:  CHRISTIAN                    |LAST UPDATE DATE:  05/09/1999|
|  HQ OPS OFFICER:  CHAUNCEY GOULD               +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |MONTE PHILLIPS       R3      |
|10 CFR SECTION:                                 |                             |
|ARPS 50.72(b)(2)(ii)     RPS ACTUATION          |                             |
|AESF 50.72(b)(2)(ii)     ESF ACTUATION          |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     M/R        Y       100      Power Operation  |0        Hot Shutdown     |
|                                                   |                          |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| MANUAL REACTOR SCRAM FROM 100% POWER DUE TO SJAE HIGH PRESSURE ISOLATION.    |
|                                                                              |
| CONTROL ROOM OPERATORS MANUALLY SCRAMMED THE REACTOR FROM 100% POWER DUE TO  |
| A STEAM JET AIR EJECTOR (SJAE) HIGH PRESSURE ISOLATION.  THE CAUSE OF THE    |
| ISOLATION IS UNKNOWN AND BEING INVESTIGATED.  ALL CONTROL RODS FULLY         |
| INSERTED AND NO ECCS INJECTIONS OCCURRED.  THE PLANT ALSO RECEIVED A         |
| PRIMARY CONTAINMENT ISOLATION (PCI) SYSTEM GROUP 1 (MSIVs CLOSED), GROUP 2   |
| (TORUS AND DRYWELL VENTS) AND GROUP 3 (RWCU SYSTEM) ISOLATIONS.  ONE SRV     |
| CYCLED OPEN AND CLOSED PROPERLY.  HOWEVER, A SECOND SRV INDICATED HIGH TAIL  |
| PIPE TEMPERATURE.  THE LICENSEE IS INVESTIGATING THIS CONDITION.             |
|                                                                              |
| THE LICENSEE PLANS TO INFORM THE NRC RESIDENT INSPECTOR.                     |
|                                                                              |
| * * * UPDATE AT 1035 ON 05/09/99 BY PAT DECKER TO JOLLIFFE * * *             |
|                                                                              |
| DURING THE SRV OPENING AND CLOSING, THE PLANT RECEIVED A PCI SYSTEM GROUP 3  |
| (RWCU SYSTEM) ISOLATION SIGNAL FROM THE REACTOR VESSEL WATER LEVEL DROPPING  |
| BELOW 9 INCHES.                                                              |
|                                                                              |
| THE LICENSEE PLANS TO INFORM THE NRC RESIDENT INSPECTOR.                     |
|                                                                              |
| THE NRC OPERATIONS OFFICER NOTIFIED THE R3DO MONTE PHILLIPS.                 |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Fuel Cycle Facility                              |Event Number:   35695       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: PORTSMOUTH GASEOUS DIFFUSION PLANT   |NOTIFICATION DATE: 05/09/1999|
|   RXTYPE: URANIUM ENRICHMENT FACILITY          |NOTIFICATION TIME: 20:22[EDT]|
| COMMENTS: 2 DEMOCRACY CENTER                   |EVENT DATE:        05/09/1999|
|           6903 ROCKLEDGE DRIVE                 |EVENT TIME:        16:45[EDT]|
|           BETHESDA, MD 20817    (301)564-3200  |LAST UPDATE DATE:  05/09/1999|
|    CITY:  PIKETON                  REGION:  3  +-----------------------------+
|  COUNTY:  PIKE                      STATE:  OH |PERSON          ORGANIZATION |
|LICENSE#:  GDP-2                 AGREEMENT:  N  |MONTE PHILLIPS       R3      |
|  DOCKET:  0707002                              |JOHN GREEVES         NMSS    |
+------------------------------------------------+FRANK CONGEL         IRO     |
| NRC NOTIFIED BY:  LARSON                       |                             |
|  HQ OPS OFFICER:  CHAUNCEY GOULD               |                             |
+------------------------------------------------+                             |
|EMERGENCY CLASS:          N/A                   |                             |
|10 CFR SECTION:                                 |                             |
|NBNL                     RESPONSE-BULLETIN      |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| NRC BULLETIN 91-01, 4 HOUR REPORT                                            |
|                                                                              |
| AT 1645 ON 05/09/99, DURING A PRESSURE DECAY TEST OF THE #1 AUTOCLAVE IN THE |
| X-342 BUILDING, A LIGHT DUSTING OF UO2F2 WAS OBSERVED INSIDE THE AUTOCLAVE   |
| AND A HEAVIER ACCUMULATION OF UO2F2 WAS OBSERVED ON THE PRESSURE DECAY       |
| FILTER USED TO PREVENT URANIUM FROM ENTERING THE AUTOCLAVE DURING THIS TEST. |
| THE AUTOCLAVE WAS PLACED IN A CONTAINMENT MODE ISOLATING IT FROM ALL SUPPORT |
| SYSTEMS.  HEALTH PHYSICS TECHNICIANS PERFORMED CONTAMINATION AND AIRBORNE    |
| SAMPLING AND ALL SAMPLES WERE LESS THAN DETECTABLE LIMITS.  HAVING URANIUM   |
| INSIDE THE SHELL OF THE AUTOCLAVE IS A LOSS OF ONE CONTROL OF THE DOUBLE     |
| CONTINGENCY PRINCIPLE CONTAINED IN NCSA_342A002.  THE ACCUMULATION OF UO2F2  |
| ON THE OUTSIDE OF THE PRESSURE DECAY FILTER IS NOT EXPECTED.  ADDITIONAL     |
| EVALUATIONS ARE BEING CONDUCTED AT THIS TIME.                                |
|                                                                              |
| THERE IS NO LOSS OF HAZARDOUS/RADIOACTIVE MATERIAL OR                        |
| RADIOACTIVE/RADIOLOGICAL CONTAMINATION EXPOSURE AS A RESULT OF THIS EVENT.   |
| THIS EVENT DOES NOT PRESENT ANY IMMINENT DANGER OF A CRITICALITY.            |
|                                                                              |
| THE AUTOCLAVE HAS BEEN ISOLATED FROM ALL POTENTIAL MODERATOR SOURCES, SO     |
| CRITICALITY IS NOT POSSIBLE.  MODERATION, ENRICHMENT AND GEOMETRY PARAMETERS |
| WERE MAINTAINED THROUGHOUT THIS EVENT.  THE UNLIKELIHOOD OF URANIUM INSIDE   |
| THE AUTOCLAVE SHELL AND OUTSIDE OF THE UF6 CYLINDER WAS A LOST PARAMETER.    |
| THE AUTOCLAVE WAS TAGGED TO PREVENT ANY OPERATION UNTIL RECOVERY PLANS ARE   |
| DEVELOPED.                                                                   |
|                                                                              |
| THE RESIDENT INSPECTOR WAS NOTIFIED.                                         |
+------------------------------------------------------------------------------+