Event Notification Report for March 26, 1999
U.S. Nuclear Regulatory Commission
Operations Center
Event Reports For
03/25/1999 - 03/26/1999
** EVENT NUMBERS **
35131 35447 35506 35507 35508 35509 35510 35511 35512 35513 35514 35515
+------------------------------------------------------------------------------+
|Fuel Cycle Facility |Event Number: 35131 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: PORTSMOUTH GASEOUS DIFFUSION PLANT |NOTIFICATION DATE: 12/09/1998|
| RXTYPE: URANIUM ENRICHMENT FACILITY |NOTIFICATION TIME: 22:17[EST]|
| COMMENTS: 2 DEMOCRACY CENTER |EVENT DATE: 12/09/1998|
| 6903 ROCKLEDGE DRIVE |EVENT TIME: 18:20[EST]|
| BETHESDA, MD 20817 (301)564-3200 |LAST UPDATE DATE: 03/25/1999|
| CITY: PIKETON REGION: 3 +-----------------------------+
| COUNTY: PIKE STATE: OH |PERSON ORGANIZATION |
|LICENSE#: GDP-2 AGREEMENT: N |MARK RING R3 |
| DOCKET: 0707002 |WAYNE HODGES, EO NMSS |
+------------------------------------------------+BOB PIERSON NMSS |
| NRC NOTIFIED BY: ERIC SPAETH |STU RUBIN, AEOD IRD |
| HQ OPS OFFICER: JOHN MacKINNON | |
+------------------------------------------------+ |
|EMERGENCY CLASS: N/A | |
|10 CFR SECTION: | |
|NBNL RESPONSE-BULLETIN | |
| | |
| | |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| NRC BULLETIN 91-01 RESPONSE, 4-HOUR NOTIFICATION - LOSS OF MODERATION AND |
| MASS CONTROL |
| |
| On 12/09/98 at 1820 EST, Plant Operations and Nuclear Criticality Safety |
| personnel identified that a Nuclear Criticality Safety Analysis (NCSA) |
| requirement could not be maintained in the X-326 building. NCSA-326_13.A06 |
| administrative control requirement #8 states, in part, "Within 8 hours after |
| cascade equipment shutdown (motor turned off) and with the system at a UF6 |
| negative, the system shall be pressurized with dry air or N2 buffer at 14 |
| psia or greater." This cannot be accomplished for cell 25-7-2 due to the |
| primary containment that was breached during a fire that occurred in the |
| cell. Also, cell 25-7-6 leaked to atmosphere prior to being buffered due to |
| possible failure of an expansion joint. Each cell contains 12 converters, |
| and the holes in the converters caused a loss of moderation control and loss |
| of mass control. The holes in the converters can let air intrude into the |
| converters which can cause a buildup of moisture in the converters. |
| |
| The certificate holder has isolated both cells and isolated the water system |
| going to both cells including the sprinkler system (fire protection system). |
| Visual inspection of a limited number of the converters and a review of |
| typical cell inventory data reveals that the cells do not contain a critical |
| mass in them. Also, the cells mentioned above have been isolated. |
| |
| The certificate holder notified the NRC Resident Inspector, the local |
| Department of Energy (DOE) representative, and the state of Ohio. The |
| certificate holder also issued a press release. |
| |
| * * * UPDATE AT 0512 EST ON 12/10/98 FROM ERIC SPAETH TO FANGIE JONES * * * |
| |
| This event notification is being updated to change the previous report of a |
| 4-hour notification (loss of moderation and mass control) to a 24-hour |
| notification due to current NDA scans that identify the deposits in |
| converter 25-7-2 to be less than the calculated safe mass. Loss of a single |
| contingency (moderation) remains a 24-hour notification. Also, it was |
| determined that the previous report of converter 25-7-6 leaking to |
| atmosphere (potential loss of moderation control) was incorrect. There was |
| no failure in converter 25-7-6 that breached containment. |
| |
| The certificate holder notified the NRC Resident Inspector, the local DOE |
| representative, and the state of Ohio. The NRC Operations Officer notified |
| the R3DO (Mark Ring), NMSS EO (Wayne Hodges), and AEOD IRD (Joe Giitter). |
| |
| (See event #35130 and event #35132.) |
| |
| *** UPDATE ON 12/11/98 @ 1644 FROM SISLER TO GOULD *** |
| |
| UPON FURTHER REVIEW OF THIS EVENT, IT HAS BEEN DETERMINED THAT THE EVENT |
| MEETS THE REPORTING CRITERIA FOR OPERATIONS THAT COMPLY WITH THE DOUBLE |
| CONTINGENCY PRINCIPLE WHERE MODERATION IS USED AS THE PRIMARY CRITICALITY |
| CONTROL. THE REPORTING CRITERIA CHANGED WHEN THE DEPOSIT IN 25-7-2 WAS |
| DETERMINED TO BE LESS THAN A SAFE MASS. NCSA-326_013.A06 ADMINISTRATIVE |
| CONTROL REQUIREMENT NO. 8 WAS NOT RE-ESTABLISHED WITHIN 4 HOURS AFTER THE |
| INITIAL OBSERVATION OF THE EVENT. THAT CONTROL IS MODERATION, AND THE |
| MODERATION CONTROL HAS YET TO BE RE-ESTABLISHED. MASS CONTROL WAS |
| MAINTAINED THROUGH THE EVENT. THIS MEETS THE BULLETIN 91-01 4-HOUR |
| REPORTING CRITERIA. THIS EVENT SHOULD NOT HAVE BEEN DOWN GRADED TO A |
| 24-HOUR REPORT. |
| |
| PORTSMOUTH PERSONNEL NOTIFIED THE NRC RESIDENT INSPECTOR ALONG WITH DOE SITE |
| REPRESENTATIVE AND THE STATE. THE NRC OPERATIONS OFFICER NOTIFIED THE R3DO |
| (RING), NMSS EO (HODGES), AND AEOD IRD (CONGEL) |
| |
| * * * UPDATE ON 3/25/99 AT 2111 EST BY RICK LARSON TO FANGIE JONES * * * |
| |
| Upon further review of this event, it has been determined that the event |
| constituted only a single contingency in that the operation of the cascade |
| is considered a single contingency in accordance with SAR 5.2. Thus, the |
| report of a double contingency loss was incorrect and the only contingency |
| lost was moderation. The report would still be an initial 4 hour |
| notification requirement. |
| |
| Portsmouth personnel notified the NRC Resident Inspector and the DOE site |
| representative. The NRC Operations Officer notified the R3DO (Melvyn |
| Leach), NMSS EO (Robert Pierson), and IRO (Joseph Giitter). |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|Power Reactor |Event Number: 35447 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: RIVER BEND REGION: 4 |NOTIFICATION DATE: 03/08/1999|
| UNIT: [1] [] [] STATE: LA |NOTIFICATION TIME: 15:15[EST]|
| RXTYPE: [1] GE-6 |EVENT DATE: 03/08/1999|
+------------------------------------------------+EVENT TIME: 11:42[CST]|
| NRC NOTIFIED BY: GEORGE TURNER |LAST UPDATE DATE: 03/25/1999|
| HQ OPS OFFICER: FANGIE JONES +-----------------------------+
+------------------------------------------------+PERSON ORGANIZATION |
|EMERGENCY CLASS: N/A |GARY SANBORN R4 |
|10 CFR SECTION: | |
|APRE 50.72(b)(2)(vi) OFFSITE NOTIFICATION | |
| | |
| | |
| | |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1 N Y 82 Power Operation |82 Power Operation |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| INADVERTENT ACTUATION OF SINGLE OFFSITE SIREN DURING TESTING OF ACTUATION |
| SYSTEM |
| |
| During Y2K testing of the offsite siren actuation system, a single siren |
| actuated for about 5 seconds. The test was terminated and the system |
| returned to pretest conditions. The licensee notified the Louisiana Office |
| of Emergency Preparedness (LOEP) and informed them of the actuation. The |
| LOEP decided not to make a public announcement on the emergency alert system |
| as the siren was only actuated for a short period of time. |
| |
| The licensee notified the local parishes and the NRC Resident Inspector. |
| |
| * * * UPDATE AT 1753 EST ON 3/25/99 BY GARY HOUSTON TO FANGIE JONES * * * |
| |
| The testing was not Y2K testing, but testing of a Y2K compliant software |
| upgrade. The Y2K testing was previously completed. The licensee notified |
| the NRC Resident Inspector. |
| |
| The NRC Operations Officer notified the R4DO (Charles Cain). |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|Power Reactor |Event Number: 35506 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: GRAND GULF REGION: 4 |NOTIFICATION DATE: 03/25/1999|
| UNIT: [1] [] [] STATE: MS |NOTIFICATION TIME: 00:18[EST]|
| RXTYPE: [1] GE-6 |EVENT DATE: 03/24/1999|
+------------------------------------------------+EVENT TIME: 21:00[CST]|
| NRC NOTIFIED BY: DAVID H. HANKS |LAST UPDATE DATE: 03/25/1999|
| HQ OPS OFFICER: JOHN MacKINNON +-----------------------------+
+------------------------------------------------+PERSON ORGANIZATION |
|EMERGENCY CLASS: N/A |CHARLES CAIN R4 |
|10 CFR SECTION: | |
|AINA 50.72(b)(2)(iii)(A) POT UNABLE TO SAFE SD | |
|AIND 50.72(b)(2)(iii)(D) ACCIDENT MITIGATION | |
|NLCO TECH SPEC LCO A/S | |
| | |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1 N Y 100 Power Operation |100 Power Operation |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| High Pressure Core Spray (HPCS) Division 3 Diesel Generator declared |
| inoperable. |
| |
| |
| HPCS (Division 3) EDG oil level was discovered to be out of specification |
| low during normal rounds. The Division 3 EDG was conservatively declared |
| inoperable until further evaluations can be performed to determine final |
| disposition of oil leakage from its inspection cover. The licensee entered |
| Technical Specification 3.8.1 (72 hour limiting conditioning of operation). |
| All Emergency Core Cooling systems including HPCS are fully operable. |
| Earlier in the day an undervoltage spike on the electrical grid caused the |
| Division 3 EDG to start. The diesel was properly secured. |
| |
| The NRC Resident Inspector was notified of this event by the licensee. |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|Fuel Cycle Facility |Event Number: 35507 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: PORTSMOUTH GASEOUS DIFFUSION PLANT |NOTIFICATION DATE: 03/25/1999|
| RXTYPE: URANIUM ENRICHMENT FACILITY |NOTIFICATION TIME: 01:36[EST]|
| COMMENTS: 2 DEMOCRACY CENTER |EVENT DATE: 03/24/1999|
| 6903 ROCKLEDGE DRIVE |EVENT TIME: 19:00[EST]|
| BETHESDA, MD 20817 (301)564-3200 |LAST UPDATE DATE: 03/25/1999|
| CITY: PIKETON REGION: 3 +-----------------------------+
| COUNTY: PIKE STATE: OH |PERSON ORGANIZATION |
|LICENSE#: GDP-2 AGREEMENT: N |PATRICK HILAND R3 |
| DOCKET: 0707002 |ROBERT PIERSON NMSS |
+------------------------------------------------+ |
| NRC NOTIFIED BY: ERIC SPAETH | |
| HQ OPS OFFICER: JOHN MacKINNON | |
+------------------------------------------------+ |
|EMERGENCY CLASS: N/A | |
|10 CFR SECTION: | |
|OCBB 76.120(c)(2)(ii) EQUIP DISABLED/FAILS | |
|OCBC 76.120(c)(2)(iii) REDUNDANT EQUIP INOP | |
| | |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| TSR allowed one of two smoke detectors to be inoperable during withdrawal |
| operations when both smoke detectors have to be operable during withdrawal |
| operations. |
| |
| On March 10, 1999, Operations personnel identified a deficiency in a TSR |
| requirement for the Pigtail line Isolation System at ERP (extended range |
| product), LAW (low assay withdrawal), and TAILS, (TSR 2.5.3.4). The TSR |
| required action allowed continued withdrawal operations if one (1) smoke |
| detector was inoperable. The Pigtail Line Isolation System requires two (2) |
| Pyrotronics Smoke Detectors to actuate for the isolation valve to close. |
| Operation personnel initiated a Compensatory Action (CA-99-009) for this |
| anomaly to isolate the withdrawal cylinder and manifold per TSR 2.5.3.4b if |
| one smoke detector is declared inoperable. |
| |
| Initially there was no evidence that the Pigtail Line Isolation System had |
| been allowed to operate any applicable mode (modes II or III) with one or |
| more inoperable smoke head. As a follow up investigation to this |
| deficiency, a search of the BPS system (problem report database) was |
| conducted. This search identified that on July 8, 1998, a Pyrotronic smoke |
| head at the Law IA withdrawal position had been declared inoperable and |
| cylinder filling operations had been allowed to continue. |
| |
| This event is reportable due to a Safety System required by the TSR not |
| being available or operable and no redundant equipment was available to |
| perform the required safety function. |
| |
| The NRC Resident Inspector was notified of this event by the certificate |
| holder. |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|Power Reactor |Event Number: 35508 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: SUSQUEHANNA REGION: 1 |NOTIFICATION DATE: 03/25/1999|
| UNIT: [] [2] [] STATE: PA |NOTIFICATION TIME: 02:34[EST]|
| RXTYPE: [1] GE-4,[2] GE-4 |EVENT DATE: 03/25/1999|
+------------------------------------------------+EVENT TIME: 01:30[EST]|
| NRC NOTIFIED BY: GRANT FERNSLER |LAST UPDATE DATE: 03/25/1999|
| HQ OPS OFFICER: JOHN MacKINNON +-----------------------------+
+------------------------------------------------+PERSON ORGANIZATION |
|EMERGENCY CLASS: N/A |JACK MCFADDEN R1 |
|10 CFR SECTION: | |
|ADAS 50.72(b)(2)(i) DEG/UNANALYZED COND | |
| | |
| | |
| | |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE |
+-----+----------+-------+--------+-----------------+--------+-----------------+
| | |
|2 N N 0 Refueling |0 Refueling |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| LOCAL LEAK RATE TEST PERFORMED ON THE "A" LOOP FEEDWATER CONTAINMENT |
| PENETRATION FAILED. |
| |
| |
| An Appendix "J" Local Leak Rate Test was performed on the "A" Loop |
| Feedwater containment penetration. The penetration piping was unable to be |
| pressurized and therefore the leakrate exceeded Tech Spec limits. The |
| penetration is isolated and the condition does not represent an immediate |
| threat to the public health or safety. |
| |
| The NRC Resident Inspector will notified of this event by the licensee. |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|Power Reactor |Event Number: 35509 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: CRYSTAL RIVER REGION: 2 |NOTIFICATION DATE: 03/25/1999|
| UNIT: [3] [] [] STATE: FL |NOTIFICATION TIME: 08:52[EST]|
| RXTYPE: [3] B&W-L-LP |EVENT DATE: 03/25/1999|
+------------------------------------------------+EVENT TIME: 08:12[EST]|
| NRC NOTIFIED BY: SERGIO ORTIZ |LAST UPDATE DATE: 03/25/1999|
| HQ OPS OFFICER: JOHN MacKINNON +-----------------------------+
+------------------------------------------------+PERSON ORGANIZATION |
|EMERGENCY CLASS: N/A |MARK LESSER R2 |
|10 CFR SECTION: | |
|APRE 50.72(b)(2)(vi) OFFSITE NOTIFICATION | |
| | |
| | |
| | |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|3 N Y 100 Power Operation |100 Power Operation |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| OFFSITE NOTIFICATION MADE TO THE FLORIDA DEPARTMENT OF ENVIRONMENTAL |
| PROTECTION CONCERNING A KEMPS RIDLEY SEA TURTLE BEING FOUND IN THE INTAKE |
| STRUCTURE. |
| |
| A SUB-ADULT KEMPS RIDLEY SEA TURTLE WAS FOUND IN THE PLANT'S INTAKE |
| STRUCTURE. THE LIVE KEMPS RIDLEY SEA TURTLE WAS TRANSPORTED TO THE |
| MARICULTURE CENTER FOR DISPOSITION/EVALUATION. THE TURTLE WILL BE |
| TRANSPORTED TO THE CLEARWATER MARINE SCIENCE CENTER FOR REHABILITATION. THE |
| FLORIDA DEPARTMENT OF ENVIRONMENTAL PROTECTION WAS NOTIFIED BY THE LICENSEE |
| OF THIS EVENT. |
| |
| THE NRC RESIDENT INSPECTOR WILL BE NOTIFIED OF THIS EVENT BY THE LICENSEE. |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|General Information or Other |Event Number: 35510 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG: TEXAS DEPARTMENT OF HEALTH |NOTIFICATION DATE: 03/25/1999|
|LICENSEE: H & G INSPECTION |NOTIFICATION TIME: 15:45[EST]|
| CITY: HOUSTON REGION: 4 |EVENT DATE: 03/12/1999|
| COUNTY: STATE: TX |EVENT TIME: [CST]|
|LICENSE#: 2181 AGREEMENT: Y |LAST UPDATE DATE: 03/25/1999|
| DOCKET: |+----------------------------+
| |PERSON ORGANIZATION |
| |CHARLES CAIN R4 |
| |JOSEPH GIITTER IRO |
+------------------------------------------------+FRED COMBS NMSS |
| NRC NOTIFIED BY: | |
| HQ OPS OFFICER: FANGIE JONES | |
+------------------------------------------------+ |
|EMERGENCY CLASS: N/A | |
|10 CFR SECTION: | |
|NAGR AGREEMENT STATE | |
|BAE1 20.2202(b)(1) PERS OVEREXPOSURE | |
| | |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| AGREEMENT STATE REPORT RECEIVED VIA FACSIMILE |
| |
| The following text is a portion of a facsimile received from the Texas |
| Department of Health: |
| |
| "10 CFR Part 20.2202(b)(1) - Exposure (real or threatened) greater than or |
| equal to TEDE of 5 rem, eye/lens 15 rem, skin/extremities 50 rads. |
| |
| "Incident report 7428: A Texas licensee - H & G Inspection had a |
| radiographer receive an annual 1998 whole body exposure of 5.4 R. The |
| Texas Department of Health Bureau of Radiation Control received the |
| notification letter on 3/17/99 and is investigating." |
| |
| There was no additional information available on the facsimile. |
| |
| See event number 35511. |
| |
| (Call the NRC Operations Center for a contact telephone number and address.) |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|General Information or Other |Event Number: 35511 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG: TEXAS DEPARTMENT OF HEALTH |NOTIFICATION DATE: 03/25/1999|
|LICENSEE: H & G INSPECTION |NOTIFICATION TIME: 15:45[EST]|
| CITY: HOUSTON REGION: 4 |EVENT DATE: 03/12/1999|
| COUNTY: STATE: TX |EVENT TIME: [CST]|
|LICENSE#: 2181 AGREEMENT: Y |LAST UPDATE DATE: 03/25/1999|
| DOCKET: |+----------------------------+
| |PERSON ORGANIZATION |
| |CHARLES CAIN R4 |
| |JOSEPH GIITTER IRO |
+------------------------------------------------+FRED COMBS NMSS |
| NRC NOTIFIED BY: | |
| HQ OPS OFFICER: FANGIE JONES | |
+------------------------------------------------+ |
|EMERGENCY CLASS: N/A | |
|10 CFR SECTION: | |
|NAGR AGREEMENT STATE | |
|BAE1 20.2202(b)(1) PERS OVEREXPOSURE | |
| | |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| AGREEMENT STATE REPORT RECEIVED VIA FACSIMILE |
| |
| The following text is a portion of a facsimile received from the Texas |
| Department of Health: |
| |
| "10 CFR Part 20.2202(b)(1) - Exposure (real or threatened) greater than or |
| equal to TEDE of 5 rem, eye/lens 15 rem, skin/extremities 50 rads. |
| |
| "Incident report 7429: A Texas licensee - H & G Inspection had a |
| radiographer receive an annual 1998 whole body exposure of 5.14 R. The |
| radiographer did not work together with the one in incident report 7428. |
| The Texas Department of Health Bureau of Radiation Control received the |
| notification letter on 3/17/99 and is investigating." |
| |
| There was no additional information available on the facsimile. |
| |
| See event number 35510. |
| |
| (Call the NRC Operations Center for a contact telephone number and address.) |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|Power Reactor |Event Number: 35512 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: COMANCHE PEAK REGION: 4 |NOTIFICATION DATE: 03/25/1999|
| UNIT: [1] [2] [] STATE: TX |NOTIFICATION TIME: 17:37[EST]|
| RXTYPE: [1] W-4-LP,[2] W-4-LP |EVENT DATE: 03/25/1999|
+------------------------------------------------+EVENT TIME: 16:04[CST]|
| NRC NOTIFIED BY: TOM BEAUDIN |LAST UPDATE DATE: 03/25/1999|
| HQ OPS OFFICER: FANGIE JONES +-----------------------------+
+------------------------------------------------+PERSON ORGANIZATION |
|EMERGENCY CLASS: N/A |CHARLES CAIN R4 |
|10 CFR SECTION: | |
|DDDD 73.71 UNSPECIFIED PARAGRAPH | |
| | |
| | |
| | |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1 N Y 100 Power Operation |100 Power Operation |
|2 N N 0 Refueling |0 Refueling |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| PHYSICAL SECURITY REPORT |
| |
| Unescorted access granted inappropriately to contract employee. Immediate |
| compensatory measures taken upon discovery. |
| |
| The licensee notified the NRC Resident Inspector. |
| |
| Refer to the HOO Log for additional details. |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|Fuel Cycle Facility |Event Number: 35513 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: PORTSMOUTH GASEOUS DIFFUSION PLANT |NOTIFICATION DATE: 03/25/1999|
| RXTYPE: URANIUM ENRICHMENT FACILITY |NOTIFICATION TIME: 18:16[EST]|
| COMMENTS: 2 DEMOCRACY CENTER |EVENT DATE: 03/25/1999|
| 6903 ROCKLEDGE DRIVE |EVENT TIME: 10:03[EST]|
| BETHESDA, MD 20817 (301)564-3200 |LAST UPDATE DATE: 03/25/1999|
| CITY: PIKETON REGION: 3 +-----------------------------+
| COUNTY: PIKE STATE: OH |PERSON ORGANIZATION |
|LICENSE#: GDP-2 AGREEMENT: N |MELVYN LEACH R3 |
| DOCKET: 0707002 |ROBERT PIERSON NMSS |
+------------------------------------------------+ |
| NRC NOTIFIED BY: J. B. HALCOMB | |
| HQ OPS OFFICER: FANGIE JONES | |
+------------------------------------------------+ |
|EMERGENCY CLASS: N/A | |
|10 CFR SECTION: | |
|NCFR NON CFR REPORT REQMNT | |
| | |
| | |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| VALID ACTUATION OF A 'Q' SAFETY SYSTEM |
| |
| "At 1003 hours on March 25, 1999, during normal charging of cell 31-3-3 |
| prior to placing onstream, an Operations |
| Front Line Manager was investigating a Cascade Automatic Data Processing |
| smokehead alarm from this cell when a second smokehead alarmed. He than saw |
| what appeared to be smoke above the Stage 6 area. |
| |
| "All personnel in the area immediately evacuated, implemented the 'See & |
| Flee' Procedure, activated the building recall system, and notified |
| Emergency Response Forces. The cell was taken offstream and cell pressure |
| was reduced below atmosphere. |
| |
| "All airborne and surface contamination sample results were less than |
| detectable and there was no release of |
| Hazardous/Radioactive material or Radioactive/Radiological contamination |
| exposure as a result of this event." |
| |
| The facility notified the NRC Resident Inspector and the DOE Site Manager. |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|General Information or Other |Event Number: 35514 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG: TEXAS DEPARTMENT OF HEALTH |NOTIFICATION DATE: 03/25/1999|
|LICENSEE: TEAM CONSULTANTS |NOTIFICATION TIME: 18:08[EST]|
| CITY: DALLAS REGION: 4 |EVENT DATE: 03/22/1999|
| COUNTY: STATE: TX |EVENT TIME: [CST]|
|LICENSE#: 4012 AGREEMENT: Y |LAST UPDATE DATE: 03/25/1999|
| DOCKET: |+----------------------------+
| |PERSON ORGANIZATION |
| |CHARLES CAIN R4 |
| |ROBERT PIERSON NMSS |
+------------------------------------------------+JOSEPH GIITTER IRO |
| NRC NOTIFIED BY: HELEN WATKINS | |
| HQ OPS OFFICER: FANGIE JONES | |
+------------------------------------------------+ |
|EMERGENCY CLASS: N/A | |
|10 CFR SECTION: | |
|NAGR AGREEMENT STATE | |
|BAB1 20.2201(a)(1)(i) LOST/STOLEN LNM>1000X | |
| | |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| AGREEMENT STATE REPORT RECEIVED VIA FACSIMILE |
| |
| The following text is a portion of a facsimile received from the Texas |
| Department of Health: |
| |
| "10 CFR Part 20.2201(a)(1)(I) - Report of theft/loss of greater than or |
| equal to 1000 X App C value." |
| |
| Incident report 7431: A Texas licensee - Team Consultants, reported that a |
| Troxler 3411B, SN 11125, Moisture Density Gauge containing Cs-137 and |
| Am-241:Be was stolen. The Texas Department of Health Bureau of Radiation |
| Control received the notification letter on 3/22/99 and is following up to |
| obtain additional information. |
| |
| There was no additional information available on the facsimile. |
| |
| (Call the NRC Operations Center for a contact telephone number and address.) |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|Power Reactor |Event Number: 35515 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: RIVER BEND REGION: 4 |NOTIFICATION DATE: 03/25/1999|
| UNIT: [1] [] [] STATE: LA |NOTIFICATION TIME: 21:11[EST]|
| RXTYPE: [1] GE-6 |EVENT DATE: 03/25/1999|
+------------------------------------------------+EVENT TIME: 16:40[CST]|
| NRC NOTIFIED BY: JOEY CLARK |LAST UPDATE DATE: 03/25/1999|
| HQ OPS OFFICER: FANGIE JONES +-----------------------------+
+------------------------------------------------+PERSON ORGANIZATION |
|EMERGENCY CLASS: N/A |CHARLES CAIN R4 |
|10 CFR SECTION: | |
|AESF 50.72(b)(2)(ii) ESF ACTUATION | |
| | |
| | |
| | |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1 N Y 78 Power Operation |78 Power Operation |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| ESF ACTUATION RESULTING IN ISOLATION OF A DIVISION 2 VALVE |
| |
| "An invalid ESF actuation resulted in the isolation of Division 2 primary |
| containment isolation valve RHSAOV62 SUPPRESSION POOL CLEANUP (SPC) SYSTEM |
| SUCTION. |
| |
| "During outage preparation activities in the Reactor Building Dryer storage |
| pool, level in the pool was inadvertently lowered approximately three and |
| one-half inches, resulting in a non-ESF isolation signal from the division 2 |
| dryer pool level indicator. The level change was caused by a siphon effect |
| that was created through a vacuum hose being staged between the Dryer Pool |
| and Refueling Cavity for pool cleanup. |
| |
| "The lowering level was terminated upon identification and all systems |
| responded as designed." |
| |
| The siphon action was started during 'bump' testing of the vacuuming system |
| during setup due to the differences in pool levels of about one foot. Work |
| has been terminated until an investigation is completed and necessary |
| changes to the work are made. |
| |
| The licensee notified the NRC Resident Inspector. |
+------------------------------------------------------------------------------+