Event Notification Report for January 26, 1999

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
01/25/1999 - 01/26/1999

EVENT NUMBERS
3531735319

Fuel Cycle Facility
Event Number: 35317
Facility: PADUCAH GASEOUS DIFFUSION PLANT
Region: 3     State: KY
Unit: [] [] []
RX Type: URANIUM ENRICHMENT FACILITY
Comments: 2 DEMOCRACY CENTER
6903 ROCKLEDGE DRIVE
BETHESDA, MD 20817 (301)564-3200
NRC Notified By: TOM WHITE
HQ OPS Officer: STEVE SANDIN
Notification Date: 01/26/1999
Notification Time: 15:25 [ET]
Event Date: 01/26/1999
Event Time: 09:15 [CST]
Last Update Date: 01/26/1999
Emergency Class: NON EMERGENCY
10 CFR Section:
Person (Organization):
TONY VEGEL (R3)
JOSEY PICCONE (NMSS)
Event Text
24-HOUR NRC 91-01 BULLETIN NOTIFICATION INVOLVING FAILURE TO MAINTAIN DOUBLE CONTINGENCY

"On 1/25/99 at 1430 CST, NCS [nuclear criticality safety] Incident report NCS-INC-99-001 was identified via ATR [problem report] as being incorrect. This NCS incident report was incorrectly classified on 1/12/99 and was subsequently not reported. The original NCS incident report concerned a pump subassembly which had been removed and the Post NDA [non-destructive assay] had not been performed within 24 hours as required by TSR 2.5.4.2. It incorrectly identified that this did not constitute a loss of a leg of the double contingency principle. Upon further review, NCS has determine that one of the legs of the double contingency principle is established by the independent verification of an always safe mass by post-removal NDA measurements performed within 24 hours of removal. Since this did not occur in the assumed time frame, double contingency was not maintained even though the NDA results did confirm an always safe mass.

"Ropes/posting used to isolate personnel from area implemented on 1/12/99 were removed that day when post-removal NDA results were obtained.

"This event is being categorized as a 24-hour event in accordance with Safety Analysis Report Table 6.9-1, Criteria A.4.a and NRC Bulletin 91-01 Supplement 1 report."

THE NRC RESIDENT INSPECTOR HAS BEEN INFORMED AND THE DOE SITE REPRESENTATIVE WILL BE INFORMED.


Other Nuclear Material
Event Number: 35319
Rep Org: CTE NEVADA, INC.
Licensee: CTE NEVADA, INC.
Region: 4
City: LAS VEGAS   State: NV
County:
License #: 00-11-0363-01
Agreement: Y
Docket:
NRC Notified By: R MICHAEL
HQ OPS Officer: JOHN MacKINNON
Notification Date: 01/28/1999
Notification Time: 10:59 [ET]
Event Date: 01/26/1999
Event Time: 18:30 [PST]
Last Update Date: 01/28/1999
Emergency Class: NON EMERGENCY
10 CFR Section:
20.2201(a)(1)(i) - LOST/STOLEN LNM>1000X
Person (Organization):
CHARLES MARSCHALL (R4)
FRED COMBS, NMSS (EO)
Event Text
TROXLER MOISTURE DENSITY GAUGE STOLEN FROM BACK OF A PICKUP TRUCK

ON 01/26/99 AT APPROXIMATELY 1630 PST AN EMPLOYEE OF CTE NEVADA, INC. PARKED A PICKUP TRUCK IN THE BACK OF THE COMPANY'S OFFICE AND ENTERED THE OFFICE VIA ITS BACK DOOR. APPROXIMATELY ONE HOUR LATER (BETWEEN 1730 - 1830 HOURS) THE EMPLOYEE WENT BACK TO THE PICKUP TRUCK AND DISCOVERED THAT THE TROXLER MOISTURE DENSITY GAUGE (MODEL 3 3400 SERIES) HOLD DOWN CHAIN HAD BEEN CUT WITH CHAIN CUTTERS AND THE GAUGE WAS MISSING. THE TROXLER MOISTURE DENSITY GAUGE CONTAINED AN 8 mCi CESIUM-137 SOURCE AND A 40mCi Am-241(Be) SOURCE. THE GAUGE WAS DOUBLE LOCKED AND IN ITS CASE WHEN IT WAS STOLEN. THE LICENSEE NOTIFIED THE STATE OF NEVADA HEALTH DEPARTMENT OF THE GAUGE BEING STOLEN AND THEY NOTIFIED THE LAS VEGAS METRO POLICE THE NEXT DAY (01/27/99) THAT THE TROXLER MOISTURE DENSITY GAUGE HAD BEEN STOLEN. THE METRO POLICE SAID THAT THEY WOULD COME OUT AND INVESTIGATE THE INCIDENT IN 2 OR 3 DAYS. THE LICENSEE WAS GIVEN THE PHONE NUMBER FOR THE STATE OF NEVADA RADIOLOGICAL HEALTH SECTION DEPARTMENT AND WAS ASKED TO CALL THEM. THE LICENSEE SAID THAT THEIR RADIATION SAFETY OFFICER WAS HANDLING THIS EVENT. THE LICENSEE SAID THAT NRC REGION 4 HAD BEEN NOTIFIED OF THE EVENT.