The U.S. Nuclear Regulatory Commission is in the process of rescinding or revising guidance and policies posted on this webpage in accordance with Executive Order 14151 Ending Radical and Wasteful Government DEI Programs and Preferencing, and Executive Order 14168 Defending Women From Gender Ideology Extremism and Restoring Biological Truth to the Federal Government. In the interim, any previously issued diversity, equity, inclusion, or gender-related guidance on this webpage should be considered rescinded that is inconsistent with these Executive Orders.

Event Notification Report for January 14, 1999

                    U.S. Nuclear Regulatory Commission
                              Operations Center

                              Event Reports For
                           01/13/1999 - 01/14/1999

                              ** EVENT NUMBERS **

35234  35247  35248  35249  35250  35251  35252  35253  35254  35255  35256  35257 
35258  35259  

+------------------------------------------------------------------------------+
|Fuel Cycle Facility                              |Event Number:   35234       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: PORTSMOUTH GASEOUS DIFFUSION PLANT   |NOTIFICATION DATE: 01/08/1999|
|   RXTYPE: URANIUM ENRICHMENT FACILITY          |NOTIFICATION TIME: 16:17[EST]|
| COMMENTS: 2 DEMOCRACY CENTER                   |EVENT DATE:        01/08/1999|
|           6903 ROCKLEDGE DRIVE                 |EVENT TIME:        12:30[EST]|
|           BETHESDA, MD 20817    (301)564-3200  |LAST UPDATE DATE:  01/13/1999|
|    CITY:  PIKETON                  REGION:  3  +-----------------------------+
|  COUNTY:  PIKE                      STATE:  OH |PERSON          ORGANIZATION |
|LICENSE#:  GDP-2                 AGREEMENT:  N  |BRENT CLAYTON        R3      |
|  DOCKET:  0707002                              |SUSAN SHANKMAN       NMSS    |
+------------------------------------------------+JOSEPH GIITTER       IRD     |
| NRC NOTIFIED BY:  KURT SISLER                  |                             |
|  HQ OPS OFFICER:  DOUG WEAVER                  |                             |
+------------------------------------------------+                             |
|EMERGENCY CLASS:          N/A                   |                             |
|10 CFR SECTION:                                 |                             |
|NBNL                     RESPONSE-BULLETIN      |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| BULLETIN 91-01 4-HOUR REPORT                                                 |
|                                                                              |
| The following text is a portion of a facsimile received from Portsmouth:     |
|                                                                              |
| "On January 8, 1999, at 1230 hours, it was discovered that no Nuclear        |
| Criticality Safety Approval (NCSA) was in place for the X-326 Evacuation     |
| Booster Station.  The Evacuation Booster Station has been abandoned in place |
| for more than 20 years.  A UF6 negative was obtained on this equipment       |
| before it was isolated from the rest of the X-326 cascade equipment.         |
| Applied Nuclear Technology (ANTS) is analyzing to determine if greater than  |
| 15 grams of U235 is present."                                                |
|                                                                              |
| "This event is being reported under criticality control (Bulletin 91-01)     |
| 4-hour due to the potential that abandoned equipment contains more than 15   |
| grams U235 requiring NCSA per [Technical Safety Requirement] 3.11.2."        |
|                                                                              |
| The NRC resident inspector was notified by Portsmouth personnel.             |
|                                                                              |
| * * * UPDATE AT 1743 ON 01/13/99 FROM SPAETH TAKEN BY STRANSKY * * *         |
|                                                                              |
| The following text is a portion of a facsimile received from Portsmouth:     |
|                                                                              |
| "[Nondestructive analysis (NDA)] results obtained from the X-326 [Evacuation |
| Booster Station] indicated numerous components containing greater than 15    |
| grams U235 present.  Enrichment was a maximum of 26% U235 with the mass      |
| deposits determined to be less than safe mass.  Two components were          |
| determined to have a U235 mass requiring the components to be handled as     |
| 'PEH' [(Planned Expeditious Handling)]."                                     |
|                                                                              |
| The NRC resident inspector has been informed of this update by Portsmouth    |
| personnel.  The NRC Operations Officer notified the R3DO (Gavula), NMSS EO   |
| (Surmeier), and IRD (Congel).                                                |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   35247       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: GRAND GULF               REGION:  4  |NOTIFICATION DATE: 01/13/1999|
|    UNIT:  [1] [] []                 STATE:  MS |NOTIFICATION TIME: 01:21[EST]|
|   RXTYPE: [1] GE-6                             |EVENT DATE:        01/13/1999|
+------------------------------------------------+EVENT TIME:        00:30[CST]|
| NRC NOTIFIED BY:  RILEY COLLINS                |LAST UPDATE DATE:  01/13/1999|
|  HQ OPS OFFICER:  LEIGH TROCINE                +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |BLAIR SPITZBERG      R4      |
|10 CFR SECTION:                                 |                             |
|ASHU 50.72(b)(1)(i)(A)   PLANT S/D REQD BY TS   |                             |
|NLCO                     TECH SPEC LCO A/S      |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          Y       100      Power Operation  |100      Power Operation  |
|                                                   |                          |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| PLANNED SHUTDOWN DUE TO INDICATIONS OF DEGRADATION ON THE DIVISION I DIESEL  |
| GENERATOR OUTPUT BREAKER CURRENT TRANSFORMERS                                |
|                                                                              |
| The following text is a portion of a facsimile received from the licensee:   |
|                                                                              |
| "[During a planned maintenance outage, it was discovered that the] Division  |
| I diesel generator output breaker current transformers (CT) have indications |
| of degradation.  [A small puddle of CT encapsulant material was noticed on   |
| the cubicle floor when the breaker cubicle was opened.]  This degradation is |
| suspected to be related to a [10 CFR] Part 21 report  from ABB Power         |
| Distribution, Inc., on CT encapsulant material dated April 17, 1989.  The    |
| [Division] I [diesel generator] is currently inoperable.  For personnel      |
| protection, it is necessary to shut down the unit to complete inspection and |
| repair.  The unit is shutting down prior to the [technical specification]    |
| time limit, and [the unit] is not currently in the shutdown action           |
| statement."                                                                  |
|                                                                              |
| At the time of this notification, the unit was approximately 24 - 25 hours   |
| into a 72-hour limiting condition for operation for planned diesel generator |
| maintenance activities.  The unit shutdown is tentatively planned to         |
| commence at 0030 on 01/13/99.  The licensee expects that the unit will enter |
| Mode 3 (Hot Shutdown) some time on day shift, and the licensee plans to      |
| place the unit in Mode 4 (Cold Shutdown).  The current estimated restart     |
| date is 01/19/99.                                                            |
|                                                                              |
| At this time, the licensee does not believe that this issue affects the      |
| other diesel generator because surveillance tests were successfully          |
| completed on it last week.  However, the impact on the other diesel          |
| generator is still being evaluated.                                          |
|                                                                              |
| The licensee notified the NRC resident inspector.                            |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   35248       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: CLINTON                  REGION:  3  |NOTIFICATION DATE: 01/13/1999|
|    UNIT:  [1] [] []                 STATE:  IL |NOTIFICATION TIME: 10:21[EST]|
|   RXTYPE: [1] GE-6                             |EVENT DATE:        01/13/1999|
+------------------------------------------------+EVENT TIME:        08:35[CST]|
| NRC NOTIFIED BY:  ROBERT POWER                 |LAST UPDATE DATE:  01/13/1999|
|  HQ OPS OFFICER:  LEIGH TROCINE                +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |JIM GAVULA           R3      |
|10 CFR SECTION:                                 |                             |
|AESS 50.72(b)(1)(v)      EMERGENCY SIREN INOP   |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          N       0        Cold Shutdown    |0        Cold Shutdown    |
|                                                   |                          |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| LOSS OF HALF OF THE OFFSITE EMERGENCY SIRENS DUE TO FREEZING RAIN            |
|                                                                              |
| The following text is a portion of a facsimile received from the licensee:   |
|                                                                              |
| "10CFR50.72(b)(1)(v) requires that a facility notify the NRC Operations      |
| Center during any event that results in a major loss of emergency offsite    |
| response capability.  Due to weather conditions causing area power outages,  |
| a system test of the emergency sirens was conducted.  During this test, it   |
| was discovered that 22 out of 44 emergency sirens were not functioning.      |
| Therefore, Clinton Power Station is making a notification pursuant to        |
| 10CFR50.72(b)(1)(v)."  The licensee's current site policy is to make a       |
| notification of this type if less than 90% of the emergency sirens are       |
| available.                                                                   |
|                                                                              |
| The licensee notified the NRC resident inspector.                            |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Fuel Cycle Facility                              |Event Number:   35249       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: WESTINGHOUSE ELECTRIC CORPORATION    |NOTIFICATION DATE: 01/13/1999|
|   RXTYPE: URANIUM FUEL FABRICATION             |NOTIFICATION TIME: 10:33[EST]|
| COMMENTS: LEU CONVERSION (UF6 to UO2)          |EVENT DATE:        01/12/1999|
|           COMMERCIAL LWR FUEL                  |EVENT TIME:        10:45[EST]|
|                                                |LAST UPDATE DATE:  01/13/1999|
|    CITY:  COLUMBIA                 REGION:  2  +-----------------------------+
|  COUNTY:  RICHLAND                  STATE:  SC |PERSON          ORGANIZATION |
|LICENSE#:  SNM-1107              AGREEMENT:  Y  |AL BELISLE           R2      |
|  DOCKET:  07001151                             |DON COOL             NMSS    |
+------------------------------------------------+FRANK CONGEL         IRD     |
| NRC NOTIFIED BY:  ED REITLER                   |                             |
|  HQ OPS OFFICER:  FANGIE JONES                 |                             |
+------------------------------------------------+                             |
|EMERGENCY CLASS:          N/A                   |                             |
|10 CFR SECTION:                                 |                             |
|KBDA 70.50(b)(4)(i)      FIRE/EXP INVOLV LNM    |                             |
|KBDB 70.50(b)(4)(ii)     DAMAGED LNM/CONTAINER  |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| FIRE DAMAGED CONTAINER OF DRY PRESS CAKE.                                    |
|                                                                              |
| An operator noticed a small fire in a polypack located in a ventilated hood  |
| which services an oven used to dry press cake.  Apparently, the press cake   |
| residue had not cooled sufficiently, and it ignited inside the polypack.     |
| The fire was promptly extinguished by the operator.  Damage was limited to   |
| the polypack, which was partially melted during the brief fire.              |
|                                                                              |
| There were no significant personnel exposures as a result of this event, no  |
| significant elevated air sample results, and no releases to the              |
| environment.                                                                 |
|                                                                              |
| The Incident Review Committee convened January 13, 1999, to review the event |
| and determine that appropriate actions are being taken to address the        |
| event.                                                                       |
|                                                                              |
| The licensee notified the NRC Region II office (David Ayres).                |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Other Nuclear Material                           |Event Number:   35250       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG:  FOOD & DRUG ADMINISTRATION           |NOTIFICATION DATE: 01/13/1999|
|LICENSEE:  FOOD & DRUG ADMINISTRATION           |NOTIFICATION TIME: 10:51[EST]|
|    CITY:  WINCHESTER               REGION:  1  |EVENT DATE:        01/13/1998|
|  COUNTY:  MIDDLESEX                 STATE:  MA |EVENT TIME:             [EST]|
|LICENSE#:  20-08361-01           AGREEMENT:  N  |LAST UPDATE DATE:  01/13/1999|
|  DOCKET:                                       |+----------------------------+
|                                                |PERSON          ORGANIZATION |
|                                                |GENE KELLY           R1      |
|                                                |JIM GAVULA           R3      |
+------------------------------------------------+DON COOL, NMSS       EO      |
| NRC NOTIFIED BY:  EDMOND BARATTA               |                             |
|  HQ OPS OFFICER:  LEIGH TROCINE                |                             |
+------------------------------------------------+                             |
|EMERGENCY CLASS:          N/A                   |                             |
|10 CFR SECTION:                                 |                             |
|BAB2 20.2201(a)(1)(ii)   LOST/STOLEN LNM>10X    |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| VARIAN NICKEL-63 GAS CHROMATOGRAPH DETECTOR MISSING FROM CHICAGO DISTRICT    |
| OFFICE                                                                       |
|                                                                              |
| There were five detectors at the Food and Drug Administration's Chicago      |
| District Office when the laboratory was closed approximately 1 year ago.  At |
| that time, three detectors were shipped to Winchester, Massachusetts; one    |
| was shipped to Arkansas; and one has been missing for approximately 1 year.  |
|                                                                              |
| The missing detector was a model-600 GC-type detector (model #02-001972-00,  |
| serial #A2980) which contained 10 - 15 mCi of Nickel-63.  It was used to     |
| detect pesticides in foods.                                                  |
|                                                                              |
| The licensee notified the NRC Region I office (Pamela Henderson).  (Call the |
| NRC Operations Center for a licensee contact telephone number and address.)  |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Other Nuclear Material                           |Event Number:   35251       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG:  TEXAS DEPARTMENT OF HEALTH           |NOTIFICATION DATE: 01/13/1999|
|LICENSEE:  GLOBAL X-RAY                         |NOTIFICATION TIME: 10:58[EST]|
|    CITY:                           REGION:  4  |EVENT DATE:        01/13/1999|
|  COUNTY:                            STATE:  TX |EVENT TIME:             [CST]|
|LICENSE#:                        AGREEMENT:  Y  |LAST UPDATE DATE:  01/13/1999|
|  DOCKET:                                       |+----------------------------+
|                                                |PERSON          ORGANIZATION |
|                                                |BLAIR SPITZBERG      R4      |
|                                                |DON COOL, NMSS       EO      |
+------------------------------------------------+FRANK CONGEL         IRD     |
| NRC NOTIFIED BY:  FACSIMILE                    |                             |
|  HQ OPS OFFICER:  LEIGH TROCINE                |                             |
+------------------------------------------------+                             |
|EMERGENCY CLASS:          N/A                   |                             |
|10 CFR SECTION:                                 |                             |
|NAGR                     AGREEMENT STATE        |                             |
|BAD1 20.2202(a)(1)       PERS OVEREXPOSURE      |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| AGREEMENT STATE REPORT REGARDING OVEREXPOSURE OF A GLOBAL X-RAY TRAINEE (10  |
| REM WHOLE BODY AND EXTREMITY HIGH ENOUGH TO CAUSE INJURY)                    |
|                                                                              |
| The following text is a portion of a facsimile received from the Texas       |
| Department of Health:                                                        |
|                                                                              |
| "10 CFR Part 20.2202(a)(1) - Exposure (real or threatened) [greater than or  |
| equal to] TEDE of 25 rem, eye/lens 15 rem, skin/extremities 50 rads."        |
|                                                                              |
| "A Texas licensee - Global X-Ray had a trainee overexposure - [Whole Body    |
| approximately equal to] 10 rem and extremity high enough to cause injury."   |
|                                                                              |
| There was no additional information available on the facsimile.              |
|                                                                              |
| (Call the NRC Operations Center for a contact telephone number and address.) |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   35252       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: TROJAN                   REGION:  4  |NOTIFICATION DATE: 01/13/1999|
|    UNIT:  [1] [] []                 STATE:  OR |NOTIFICATION TIME: 12:07[EST]|
|   RXTYPE: [1] W-4-LP                           |EVENT DATE:        01/13/1999|
+------------------------------------------------+EVENT TIME:        08:40[PST]|
| NRC NOTIFIED BY:  E CAZIER                     |LAST UPDATE DATE:  01/13/1999|
|  HQ OPS OFFICER:  BOB STRANSKY                 +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |BLAIR SPITZBERG      R4      |
|10 CFR SECTION:                                 |                             |
|APRE 50.72(b)(2)(vi)     OFFSITE NOTIFICATION   |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          N       0        Decommissioned   |0        Decommissioned   |
|                                                   |                          |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| OFFSITE NOTIFICATION REGARDING OIL SHEEN IN COLUMBIA RIVER                   |
|                                                                              |
| The licensee notified the Coast Guard and the Oregon Emergency Management    |
| Division regarding the sighting of an oil sheen on the Columbia River.  The  |
| licensee reported that, at 0800 PST on 01/12/99, a small quantity of oil     |
| (less than one pint) leaked out of a drop box located on the intake          |
| structure access road and was washed into the river by rain.                 |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   35253       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: SOUTH TEXAS              REGION:  4  |NOTIFICATION DATE: 01/13/1999|
|    UNIT:  [] [2] []                 STATE:  TX |NOTIFICATION TIME: 12:25[EST]|
|   RXTYPE: [1] W-4-LP,[2] W-4-LP                |EVENT DATE:        01/12/1999|
+------------------------------------------------+EVENT TIME:        17:00[CST]|
| NRC NOTIFIED BY:  JOHN CRAIN                   |LAST UPDATE DATE:  01/13/1999|
|  HQ OPS OFFICER:  BOB STRANSKY                 +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |BLAIR SPITZBERG      R4      |
|10 CFR SECTION:                                 |                             |
|NLTR                     LICENSEE 24 HR REPORT  |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|                                                   |                          |
|2     N          Y       100      Power Operation  |100      Power Operation  |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| 24-HOUR REPORT IN ACCORDANCE WITH OPERATING LICENSE DUE TO INADEQUATE        |
| TESTING OF STATION BATTERIES                                                 |
|                                                                              |
| The licensee reported that  testing of the 'B' and 'D' station batteries was |
| not performed in accordance with Technical Specification (TS) 4.8.2.1e due   |
| to improper application of a test waiver provided in TS 4.8.2.1d.            |
|                                                                              |
| The following report was submitted by the licensee via facsimile:            |
|                                                                              |
| "Technical Specification 4.8.2.1d requires a service test every 18 months.   |
| A service test is a discharge test that demonstrates the ability of the      |
| battery to meet the design load profile of the DC system under accident      |
| conditions.  Technical Specification 4.8.2.1e requires a performance test    |
| every 60 months.  A performance test is a discharge test that measures the   |
| capacity of the battery against the manufacturer's rated capacity.  This     |
| Specification also states, 'Once per 60-month interval this performance      |
| discharge test may be performed in lieu of the battery service test required |
| by Specification 4.8.2.1d.'  Technical Specification 4.8.2.1f requires a     |
| performance test every 18 months when a battery reaches 85% of its design    |
| life."                                                                       |
|                                                                              |
| "The B and D train batteries entered service in 1978.  The service date is   |
| determined from the time they were placed into the service for which they    |
| were intended.  For these batteries that is the date they were placed on     |
| float charge.  The batteries have a qualified life of 20 years.  Therefore,  |
| they reached the 17-year, 85% Technical Specification limit in 1995 per ESR  |
| 87-VT-065."                                                                  |
|                                                                              |
| "The following is the time line for battery testing in Unit 2:               |
| 1993, routine 60-month performance test (using OPSP06-DJ-0005) in accordance |
| with 4.8.2.1e taking credit                                                  |
| for the service test.                                                        |
| 1994, routine 18-month service test (using OPSP06-DJ-0004) in accordance     |
| with 4.8.2.1d.                                                               |
| 1995, special 18-month performance test (using OPSP06-DJ-0005) in accordance |
| with 4.8.2.1 f.  No service                                                  |
| test performed. Credit for the service test is taken based on the            |
| performance test in accordance with                                          |
| OPSP06-DJ-0005, Section 1.1.                                                 |
| 1997, special 18-month performance test (using OPSP06-DJ-0005) in accordance |
| with 4.8.2.1f.  No service                                                   |
| test performed.  Credit for the service test is taken based on the           |
| performance test in accordance with                                          |
| OPSP06-DJ-0005, Section 1.1.                                                 |
| 1998, (end of qualified life) the batteries were replaced."                  |
|                                                                              |
| "The testing performed does not meet the requirement of Technical            |
| Specification 4.8.2.1e in that Technical Specification 4.8.2.1d only allows  |
| credit for the service test once in a 60-month interval. Since the new       |
| 60-month interval started in 1993, the testing in 1995 and/or 1997 should    |
| have included both a service test and a performance test. Both service and   |
| performance tests are required in accordance with our commitment to Reg.     |
| Guide 1.129, Rev. 1."                                                        |
|                                                                              |
| The licensee has notified the NRC resident inspector regarding this report.  |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   35254       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: NINE MILE POINT          REGION:  1  |NOTIFICATION DATE: 01/13/1999|
|    UNIT:  [1] [2] []                STATE:  NY |NOTIFICATION TIME: 13:05[EST]|
|   RXTYPE: [1] GE-2,[2] GE-5                    |EVENT DATE:        01/13/1999|
+------------------------------------------------+EVENT TIME:        12:10[EST]|
| NRC NOTIFIED BY:  LAURIE RAYLE                 |LAST UPDATE DATE:  01/13/1999|
|  HQ OPS OFFICER:  BOB STRANSKY                 +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |GENE KELLY           R1      |
|10 CFR SECTION:                                 |                             |
|AARC 50.72(b)(1)(v)      OTHER ASMT/COMM INOP   |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          Y       100      Power Operation  |100      Power Operation  |
|2     N          N       0                         |0                         |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| TECHNICAL SUPPORT CENTER VENTILATION DECLARED INOPERABLE                     |
|                                                                              |
| The licensee declared the Technical Support Center ventilation system        |
| inoperable after a system test indicated high supply flow rates and low      |
| differential pressure.  The licensee is investigating the problem but        |
| believes that it is due to high wind speeds.  The NRC resident inspector has |
| been informed of this event by the licensee.                                 |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   35255       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: DUANE ARNOLD             REGION:  3  |NOTIFICATION DATE: 01/13/1999|
|    UNIT:  [1] [] []                 STATE:  IA |NOTIFICATION TIME: 15:06[EST]|
|   RXTYPE: [1] GE-4                             |EVENT DATE:        01/13/1999|
+------------------------------------------------+EVENT TIME:        13:34[CST]|
| NRC NOTIFIED BY:  WAYNE BENTLEY                |LAST UPDATE DATE:  01/13/1999|
|  HQ OPS OFFICER:  BOB STRANSKY                 +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |JIM GAVULA           R3      |
|10 CFR SECTION:                                 |                             |
|AOUT 50.72(b)(1)(ii)(B)  OUTSIDE DESIGN BASIS   |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          Y       100      Power Operation  |100      Power Operation  |
|                                                   |                          |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| STANDBY GAS TREATMENT TRAIN DECLARED INOPERABLE                              |
|                                                                              |
| The licensee has declared the 'A' train of the Standby Gas Treatment System  |
| (SGTS) inoperable due to concerns regarding the seismic qualification of     |
| certain piping supports. These supports do not appear to meet seismic design |
| requirements. The 'B' train of SGTS is not affected by this issue.  The NRC  |
| resident inspector has been informed of this notification by the licensee.   |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   35256       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: CALVERT CLIFFS           REGION:  1  |NOTIFICATION DATE: 01/13/1999|
|    UNIT:  [1] [2] []                STATE:  MD |NOTIFICATION TIME: 16:56[EST]|
|   RXTYPE: [1] CE,[2] CE                        |EVENT DATE:        01/13/1999|
+------------------------------------------------+EVENT TIME:        15:45[EST]|
| NRC NOTIFIED BY:  ROBERT PACE                  |LAST UPDATE DATE:  01/13/1999|
|  HQ OPS OFFICER:  BOB STRANSKY                 +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |GENE KELLY           R1      |
|10 CFR SECTION:                                 |                             |
|APRE 50.72(b)(2)(vi)     OFFSITE NOTIFICATION   |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          Y       100      Power Operation  |100      Power Operation  |
|2     N          Y       100      Power Operation  |100      Power Operation  |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| OFFSITE NOTIFICATION TO STATE DEPARTMENT OF HEALTH REGARDING WATER TEST      |
|                                                                              |
| Water samples taken from the Calvert Cliffs Visitor's Center on 01/12/99     |
| indicate the presence of fecal coliform.  The licensee has sent the samples  |
| to an offsite laboratory for confirmation and plans to contact the Maryland  |
| Department of Health on 01/14/99.  The NRC resident inspector will be        |
| informed of this notification by the licensee.                               |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   35257       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: CALVERT CLIFFS           REGION:  1  |NOTIFICATION DATE: 01/13/1999|
|    UNIT:  [1] [2] []                STATE:  MD |NOTIFICATION TIME: 17:17[EST]|
|   RXTYPE: [1] CE,[2] CE                        |EVENT DATE:        01/13/1999|
+------------------------------------------------+EVENT TIME:        16:14[EST]|
| NRC NOTIFIED BY:  ROBERT PACE                  |LAST UPDATE DATE:  01/13/1999|
|  HQ OPS OFFICER:  BOB STRANSKY                 +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |GENE KELLY           R1      |
|10 CFR SECTION:                                 |BRUCE BOGER          NRR     |
|APRE 50.72(b)(2)(vi)     OFFSITE NOTIFICATION   |RICHARD ROSANO       IAT     |
|                                                |JOHN DAVIDSON        IAT     |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          Y       100      Power Operation  |100      Power Operation  |
|2     N          Y       100      Power Operation  |100      Power Operation  |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| OFFSITE NOTIFICATIONS REGARDING FIRE IN OWNER CONTROLLED AREA                |
|                                                                              |
| The licensee notified the Maryland State Fire Marshall and Department of     |
| Natural Resources regarding a fire within the owner controlled area.  A fire |
| of approximately 30' x 15' was discovered in the Camp Canoi recreation area  |
| at a location adjacent to the site of a fire on 01/12/99. (Refer to event    |
| #35244.) The fire was extinguished as a result of efforts by both onsite and |
| offsite fire fighters. An eyewitness recorded the license number of a        |
| vehicle seen leaving the area, and the Maryland State Police was able to     |
| identify the suspect.                                                        |
|                                                                              |
| The NRC resident inspector has been informed of this event by the licensee.  |
|                                                                              |
| [HOO NOTE:  A conference call was held between NRC Region I (Kelly, Lanning, |
| et. al.), NRR (Rosano), and the licensee regarding the details of this event |
| and the licensee's response.]                                                |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   35258       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: HATCH                    REGION:  2  |NOTIFICATION DATE: 01/13/1999|
|    UNIT:  [1] [2] []                STATE:  GA |NOTIFICATION TIME: 17:22[EST]|
|   RXTYPE: [1] GE-4,[2] GE-4                    |EVENT DATE:        01/13/1999|
+------------------------------------------------+EVENT TIME:        16:48[EST]|
| NRC NOTIFIED BY:  BRUCE BUTLER                 |LAST UPDATE DATE:  01/13/1999|
|  HQ OPS OFFICER:  BOB STRANSKY                 +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |AL BELISLE           R2      |
|10 CFR SECTION:                                 |                             |
|AARC 50.72(b)(1)(v)      OTHER ASMT/COMM INOP   |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          Y       100      Power Operation  |100      Power Operation  |
|2     N          Y       100      Power Operation  |100      Power Operation  |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| MOMENTARY LOSS OF PROMPT NOTIFICATION SYSTEM                                 |
|                                                                              |
| The licensee reported that both the primary and backup lines to the National |
| Weather Service (NWS) office in Jacksonville, FL, were lost for three        |
| 10-second periods during a 2-minute interval beginning at 1648 EST.  The     |
| licensee contacted the NWS office but was unable to determine the cause of   |
| the communications interruptions.  No further interruptions have been noted  |
| since 1650 EST.                                                              |
|                                                                              |
| The NRC resident inspector will be informed of this notification by the      |
| licensee.                                                                    |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   35259       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: BIG ROCK POINT           REGION:  3  |NOTIFICATION DATE: 01/14/1999|
|    UNIT:  [1] [] []                 STATE:  MI |NOTIFICATION TIME: 03:26[EST]|
|   RXTYPE: [1] GE-1                             |EVENT DATE:        01/14/1999|
+------------------------------------------------+EVENT TIME:        03:00[EST]|
| NRC NOTIFIED BY:  MIKE AZURE                   |LAST UPDATE DATE:  01/14/1999|
|  HQ OPS OFFICER:  LEIGH TROCINE                +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |JIM GAVULA           R3      |
|10 CFR SECTION:                                 |                             |
|AENS 50.72(b)(1)(v)      ENS INOPERABLE         |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          N       0        Decommissioned   |0        Decommissioned   |
|                                                   |                          |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| LOSS OF EMERGENCY NOTIFICATION SYSTEM (ENS) AND COMMERCIAL TELEPHONES        |
|                                                                              |
| At 0300, it was discovered that the FTS-2000 ENS telephone line and the      |
| offsite commercial telephone lines were out of service. The cause of this    |
| telephone outage is unknown at this time.  However, the licensee stated that |
| there does not seem to be a trunk line problem.  The licensee has contacted  |
| Ameritech and a local telephone representative. Offsite communications are   |
| available via the use of cellular telephones and base radios to the Michigan |
| State Police and to the licensee's power control (load dispatcher).  Outside |
| calls can be made from those locations if it is necessary to relay           |
| information.                                                                 |
|                                                                              |
| (Call the NRC Operations Center for a licensee cellular telephone number.)   |
+------------------------------------------------------------------------------+
