Abstract
Document resumes the final calculations of the thermal-hydraulic aspects of the OECD LOFT-LP-FP-1 experiment, with emphasis in those related with the assessment of the TRAC-PF1 code.
LOFT LP-FP-1 experiment was carried out at the LOFT facility in INEL, sponsored by the OECD.
Code used for this simulation was TRAC-PF1/Mod 1 (version 11.0) running on a CDC Cyber 830 (O.S. NOS-BE).