Information Notice No. NO 86-21, Supplement 1: RECOGNITION OF AMERICAN
SOCIETY OF MECHANICAL
ENGINEERS ACCREDITATION
PROGRAM FOR N STAMP
HOLDERS
Addressees:
All nuclear power facilities holding an operating licensee or a construction
permit
Purpose:
This notice is provided to licensees and construction permit holders to
clarify the information provided by IN 86-21 on the NRC's recognition of the
American Society of Mechanical Engineers (ASME) Accreditation Program for
holders of N, NA, NPT, and NV stamps and Certificates of Authorization It
is expected that recipients will review the information for applicability to
their facilities However, suggestions contained in this information notice
do not constitute NRC requirements; therefore, no specific action or written
response is required
Discussion:
IN 86-21 informed licensees that the NRC recognized the ASME Accreditation
Program for N, NA, NPT, and NV stamps and the associated Certificates of
Authorization IN 86-21 also stated that quality system certificates issued
to material manufacturers and material suppliers were excluded from this
recognition
The statement concerning quality system certificate holders has been
misinterpreted by several licensees resulting in quality system certificate
holders being removed from approved vendor lists This was not the intent of
IN 86-21 Quality system certificate holders were excluded from the
recognition announced in IN 86-21 because the quality system certificate
program was not covered by the exchange of correspondence between ASME, NRC,
and the National Board of Boiler and Pressure Vessel Inspectors If a
licensee's NRC approved quality assurance (QA) program allows material
manufacturers and material suppliers to be placed on the approved vendor
list on the basis of a quality system certificate, then that method of
evaluating and selecting vendors is not affected by the issuance of IN
86-21
8612010331
IN 86-21, Supplement 1
December 4, 1986
Page 2 of 2
No specific action or response is required by this information notice If
you have any questions regarding this notice, please contact the Regional
Administrator of the appropriate NRC regional office or the technical
contact listed below
Edward L Jordan Director
Division of Emergency Preparedness
and Engineering Response
Office of Inspection and Enforcement
Technical Contact: E T Baker, IE
301-492-9663
Attachment: List of Recently Issued IE Information Notices