SER for GEXL Correlation for 8x8R Fuel Reload Application per the Appendix D Submittals of the General Electric Topical Report, NEDE-24011-P-A, Dated February 28, 1979 and December 14, 1979 (Generic Letter 81-13)
UNITED STATES
NUCLEAR REGULATORY COMMISSION
WASHINGTON, D.C. 20555
May 28, 1981
ALL OPERATING BWR LICENSEES
SUBJECT: SER FOR GEXL CORRELATION FOR 8x8R FUEL RELOAD APPLICATION PER THE
APPENDIX D SUBMITTALS OF THE GENERAL ELECTRIC TOPICAL REPORT,
NEDE-24011-P-A, DATED FEBRUARY 28, 1979 AND DECEMBER 14, 1979
GENERIC LETTER - 81-13
We have completed the review of the General Electric Company submittals
regarding the application of the GEXL correlation to 8x8R fuel. We have
concluded that the GEXL correlation is acceptable for 8x8R fuel reload
application and the Appendix D submittals of the General Electric Topical
Report, NEDE-24011P-A, dated February 28, 1979 and December 14, 1979, are
acceptable for incorporation into that document. The General Electric
Company has been informed of this matter by letter dated April 16, 1981.
A safety evaluation describing the basis for our conclusions is enclosed for
your information.
Sincerely,
Thomas A. Ippolito, Chief
Operating Reactors Branch #2
Division of Licensing
Enclosure:
Safety Evaluation
Page Last Reviewed/Updated Tuesday, February 26, 2013