Power Reactor Status Report for April 29, 2024

UNEVALUATED INFORMATION PROVIDED BY THE FACILITY

On this page:

Region 1

Unit Power Down Reason or Comment Change in report (*) Number of Scrams (#)
Beaver Valley 1 0 4/13/2024 Refueling Outage
Beaver Valley 2 100
Calvert Cliffs 1 100
Calvert Cliffs 2 100
FitzPatrick 100
Ginna 100
Hope Creek 1 0 4/4/2024 Refueling Outage
*
Limerick 1 60 Increasing Power
*
Limerick 2 100
Millstone 2 100
Millstone 3 100

Nine Mile Point 1 100
Nine Mile Point 2 100
Peach Bottom 2 100
Peach Bottom 3 100
Salem 1 100
Salem 2 100
Seabrook 1 100 Limited to Less Than 1100MW
Susquehanna 1 90 Increasing Power
*
Susquehanna 2 100

Region 2

Unit Power Down Reason or Comment Change in report (*) Number of Scrams (#)
Browns Ferry 1 0 4/24/2024 See EN 57090

Browns Ferry 2 100
Browns Ferry 3 100
Brunswick 1 100

Brunswick 2 100
Catawba 1 100
Catawba 2 100
Farley 1 0 4/8/2024 Refueling Outage
Farley 2 100
Harris 1 0 4/10/2024 Refueling Outage
Hatch 1 99 Holding power
Hatch 2 100
McGuire 1 100
McGuire 2 100
North Anna 1 100
North Anna 2 100
Oconee 1 100
Oconee 2 98
Reduced Power For Maintenance
*
Oconee 3 97 Coastdown To Refueling Outage
Robinson 2 100
Saint Lucie 1 100
Saint Lucie 2 100
Sequoyah 1 0 3/23/2024 Refueling Outage
*
Sequoyah 2 100
Summer 100

Surry 1 0 4/7/2024 Refueling Outage
Surry 2 100
Turkey Point 3 100
Turkey Point 4 100
Vogtle 1 100
Vogtle 2 100
Vogtle 3 100
Vogtle 4 100
Watts Bar 1 100
Watts Bar 2 100

Region 3

Unit Power Down Reason or Comment Change in report (*) Number of Scrams (#)
Braidwood 1 0 4/15/2024 Refueling Outage
Braidwood 2 100
Byron 1 100
Byron 2 100
Clinton 100
D.C. Cook 1 100
D.C. Cook 2 0 3/22/2024 Refueling Outage
Reduced Power For Maintenance
*
Davis-Besse 100
Dresden 2 100
Dresden 3 100
Fermi 2 0 3/23/2024 Refueling Outage
*
LaSalle 1 100
LaSalle 2 96 Reduced power for planned outage
Monticello 100
Perry 1 100
Point Beach 1 100
Point Beach 2 100
Prairie Island 1 100
Prairie Island 2 100
Quad Cities 1 100
Quad Cities 2 100

Region 4

Unit Power Down Reason or Comment Change in report (*) Number of Scrams (#)
Arkansas Nuclear 1 0 4/27/2024 Refueling Outage
*
Arkansas Nuclear 2 100
Callaway 100
Columbia Generating Station 100
Comanche Peak 1 100
Comanche Peak 2 100
Cooper 100
Diablo Canyon 1 100
Diablo Canyon 2 0 4/7/2024
Refueling Outage
Grand Gulf 1 100
Palo Verde 1 100
Palo Verde 2 100

Palo Verde 3 0 4/6/2024 Refueling Outage
River Bend Station 1 100

South Texas 1 100
South Texas 2 0 3/23/2024 Refueling Outage
Waterford 3 0 3/21/2024 EN 57042
Forced Outage
Wolf Creek 1 0 3/28/2024 Refueling Outage.

* - Power Reactor Status Report change within past 24 hours
# - Number of reactor scrams or trips within past 24 hours

Notes:
  • Reactor status data collected between 4 a.m. and 8 a.m. each day.
  • All times are based on eastern time.
  • Additional plant status information is made available on the web page after 28 days.