Power Reactor Status Report for February 2, 2008
UNEVALUATED INFORMATION PROVIDED BY THE FACILITY
On this page:
Region 1
Unit | Power | Down | Reason or Comment | Change in report (*) | Number of Scrams (#) |
Beaver Valley 1 | 100 | | | | |
Beaver Valley 2 | 100 | | | | |
Calvert Cliffs 1 | 100 | | | | |
Calvert Cliffs 2 | 100 | | | | |
FitzPatrick | 100 | | | | |
Ginna | 100 | | | | |
Hope Creek 1 | 73 | | LOWERING POWER TO 50% TO REPAIR #2 TURBINE CONTROL VALVE | * | |
Indian Point 2 | 100 | | | | |
Indian Point 3 | 100 | | | | |
Limerick 1 | 97 | | COASTDOWN TO REFUELING OUTAGE | * | |
Limerick 2 | 0 | 02/01/2008 | REACTOR SCRAM - SEE EN #43949 | * | 1 |
Millstone 2 | 100 | | | | |
Millstone 3 | 100 | | | | |
Nine Mile Point 1 | 100 | | | | |
Nine Mile Point 2 | 100 | | | | |
Oyster Creek | 92 | | HOLDING POWER FOR TURBINE VALVE ISSUES | * | |
Peach Bottom 2 | 100 | | | | |
Peach Bottom 3 | 63 | | ROD PATTERN ADJUSTMENT IN-PROGRESS | * | |
Pilgrim 1 | 100 | | | | |
Salem 1 | 100 | | | | |
Salem 2 | 100 | | | | |
Seabrook 1 | 100 | | | * | |
Susquehanna 1 | 100 | | | | |
Susquehanna 2 | 100 | | VOLTAGE REGULATOR IN MANUAL | | |
Three Mile Island 1 | 100 | | | | |
Vermont Yankee | 100 | | | | |
Region 2
Unit | Power | Down | Reason or Comment | Change in report (*) | Number of Scrams (#) |
Browns Ferry 1 | 100 | | | | |
Browns Ferry 2 | 100 | | | | |
Browns Ferry 3 | 100 | | | | |
Brunswick 1 | 100 | | COASTDOWN TO REFUELING OUTAGE FEEDWATER TEMPERATURE REDUCTION TO MAINTAIN 100% POWER | | |
Brunswick 2 | 100 | | | | |
Catawba 1 | 100 | | | | |
Catawba 2 | 100 | | | | |
Crystal River 3 | 100 | | | | |
Farley 1 | 100 | | | | |
Farley 2 | 100 | | | | |
Harris 1 | 100 | | | | |
Hatch 1 | 90 | | COASTDOWN TO REFUELING OUTAGE CONDENSATE PUMP TRIP | | |
Hatch 2 | 100 | | | | |
McGuire 1 | 100 | | | | |
McGuire 2 | 100 | | | | |
North Anna 1 | 100 | | | | |
North Anna 2 | 0 | 02/01/2008 | SHUTDOWN FOR RCP MAINTENANCE | * | |
Oconee 1 | 100 | | | | |
Oconee 2 | 100 | | | | |
Oconee 3 | 100 | | | | |
Robinson 2 | 100 | | | | |
Saint Lucie 1 | 100 | | | | |
Saint Lucie 2 | 0 | 01/29/2008 | REDUCED INVENTORY TO PERFORM MAINTENANCE ON RCPS | | |
Sequoyah 1 | 100 | | | | |
Sequoyah 2 | 100 | | | | |
Summer | 36 | | INCREASING POWER | * | |
Surry 1 | 100 | | | | |
Surry 2 | 100 | | | | |
Turkey Point 3 | 100 | | | | |
Turkey Point 4 | 100 | | | | |
Vogtle 1 | 98 | | 100% ELECTRICAL CAPABILITY | * | |
Vogtle 2 | 98 | | 100% ELECTRICAL CAPABILITY | | |
Watts Bar 1 | 100 | | TWO WATTS BAR HYDRO SWITCHYARD 161KV CONTINGENCY LINES OOS | | |
Region 3
Unit | Power | Down | Reason or Comment | Change in report (*) | Number of Scrams (#) |
Braidwood 1 | 85 | | INCREASING POWER | * | |
Braidwood 2 | 100 | | | | |
Byron 1 | 100 | | | | |
Byron 2 | 100 | | | | |
Clinton | 0 | 01/11/2008 | REFUELING OUTAGE | | |
D.C. Cook 1 | 100 | | | | |
D.C. Cook 2 | 100 | | | | |
Davis-Besse | 20 | | HOLDING POWER | * | |
Dresden 2 | 97 | | 100% ELECTRICAL CAPABILITY | | |
Dresden 3 | 97 | | 100% ELECTRICAL CAPABILITY | | |
Duane Arnold | 98 | | 100% ELECTRICAL CAPABILITY. | | |
Fermi 2 | 0 | 01/31/2008 | LOSS OF RECIRC PUMPS - SEE EN# 43948 | * | |
Kewaunee | 100 | | | | |
La Salle 1 | 80 | | COASTDOWN TO REFUELING OUTAGE | * | |
La Salle 2 | 100 | | | | |
Monticello | 100 | | | | |
Palisades | 100 | | | | |
Perry 1 | 100 | | | | |
Point Beach 1 | 0 | 01/16/2008 | EXITING OUTAGE | * | |
Point Beach 2 | 100 | | | | |
Prairie Island 1 | 93 | | COASTDOWN TO REFUELING OUTAGE | * | |
Prairie Island 2 | 100 | | | | |
Quad Cities 1 | 35 | | TUBE PLUGGING REPAIR - MAIN CONDENSER | * | |
Quad Cities 2 | 96 | | 100% ELECTRICAL CAPABILITY | | |
Region 4
Unit | Power | Down | Reason or Comment | Change in report (*) | Number of Scrams (#) |
Arkansas Nuclear 1 | 100 | | | | |
Arkansas Nuclear 2 | 100 | | | | |
Callaway | 100 | | | | |
Columbia Generating Station | 100 | | RECIRC PUMPS IN MANUAL | | |
Comanche Peak 1 | 0 | 02/01/2008 | SCHEDULED MAINTENANCE | * | |
Comanche Peak 2 | 100 | | | | |
Cooper | 100 | | | | |
Diablo Canyon 1 | 100 | | 230 KV MORRO BAY-MIDWAY LINE OOS TIL MID MARCH 500 KV DIABLO LINE OOS | * | |
Diablo Canyon 2 | 94 | | COASTDOWN TO REFUELING OUTAGE 230 KV MORRO BAY-MIDWAY LINE OOS TIL MID MARCH 500 KV DIABLO LINE OOS | * | |
Fort Calhoun | 100 | | | | |
Grand Gulf 1 | 100 | | | | |
Palo Verde 1 | 100 | | | * | |
Palo Verde 2 | 100 | | | | |
Palo Verde 3 | 100 | | | | |
River Bend 1 | 0 | 01/06/2008 | DEFUELED | * | |
San Onofre 2 | 98 | | ADMINISTRATIVE LIMIT BASED ON STEAM GENERATOR LIMITATIONS | | |
San Onofre 3 | 100 | | | | |
South Texas 1 | 100 | | | | |
South Texas 2 | 100 | | | | |
Waterford 3 | 100 | | | | |
Wolf Creek 1 | 100 | | | | |
* - Power Reactor Status Report change within past 24 hours
# - Number of reactor scrams or trips within past 24 hours