Power Reactor Status Report for December 4, 2004

UNEVALUATED INFORMATION PROVIDED BY THE FACILITY

On this page:

Region 1

Unit Power Down Reason or Comment Change in report (*) Number of Scrams (#)
Beaver Valley 1 100        
Beaver Valley 2 98   I&C TESTING FOR TAV DT *  
Calvert Cliffs 1 100        
Calvert Cliffs 2 100        
FitzPatrick 100        
Ginna 100        
Hope Creek 1 0 10/10/2004 DEFUELED    
Indian Point 2 2   UNIT IS OFF LINE. SEE EN#41241. *  
Indian Point 3 100        
Limerick 1 100        
Limerick 2 100        
Millstone 2 100        
Millstone 3 100        
Nine Mile Point 1 100        
Nine Mile Point 2 63   FLUX DEPRESSION TESTING FOR FUEL PIN LEAK *  
Oyster Creek 100        
Peach Bottom 2 100        
Peach Bottom 3 100        
Pilgrim 1 100        
Salem 1 0 12/03/2004 PLANNED SHUTDOWN DUE TO OIL TANKER SPILL. SEE EN#41240. *  
Salem 2 0 12/03/2004 PLANNED SHUTDOWN DUE TO OIL TANKER SPILL. SEE EN#41240. *  
Seabrook 1 100        
Susquehanna 1 100        
Susquehanna 2 100        
Three Mile Island 1 72   REPAIRING HEATER DRAIN PIPE DUE TO STEAM LEAK *  
Vermont Yankee 100        

Region 2

Unit Power Down Reason or Comment Change in report (*) Number of Scrams (#)
Browns Ferry 1 0 03/03/1985 DEFUELED    
Browns Ferry 2 100        
Browns Ferry 3 100        
Brunswick 1 100        
Brunswick 2 95   POWER COASTDOWN TO REFUELING OUTAGE    
Catawba 1 100        
Catawba 2 100        
Crystal River 3 100        
Farley 1 100        
Farley 2 100        
Harris 1 100        
Hatch 1 100        
Hatch 2 100     *  
McGuire 1 100        
McGuire 2 94   INCREASING POWER AFTER TURBINE VALVE TESTING *  
North Anna 1 100        
North Anna 2 100        
Oconee 1 100        
Oconee 2 100        
Oconee 3 0 10/08/2004 DEFUELED    
Robinson 2 100        
Saint Lucie 1 100        
Saint Lucie 2 100        
Sequoyah 1 100        
Sequoyah 2 100        
Summer 100        
Surry 1 30   HOLDING FOR FLUX MAPPING *  
Surry 2 100        
Turkey Point 3 64   HOLDING FOR NUCLEAR INSTRUMENT CALIBRATION *  
Turkey Point 4 100        
Vogtle 1 100        
Vogtle 2 100        
Watts Bar 1 100        

Region 3

Unit Power Down Reason or Comment Change in report (*) Number of Scrams (#)
Braidwood 1 100        
Braidwood 2 100        
Byron 1 100        
Byron 2 100        
Clinton 95   100% ELECTRICAL CAPABILITY    
D.C. Cook 1 100        
D.C. Cook 2 100        
Davis-Besse 100        
Dresden 2 0 11/02/2004 SHUTDOWN FOR MAIN TURBINE REPAIR AND INSPECTING THE STEAM DRYER    
Dresden 3 0 10/26/2004 RESTART PREPARATIONS IN PROGRESS    
Duane Arnold 94   100% ELECTRICAL CAPABILITY    
Fermi 2 56   HOLDING POWER FOR THERMAL LIMIT CALCULATIONS *  
Kewaunee 6   HOLDING POWER FOR PLANNED MAINTENANCE *  
La Salle 1 100        
La Salle 2 100        
Monticello 75   PERFORMING MSIV TESTING *  
Palisades 100        
Perry 1 100        
Point Beach 1 100        
Point Beach 2 100        
Prairie Island 1 99        
Prairie Island 2 100        
Quad Cities 1 85   LIMITED IN POWER (STEAM DRYER MONITORING)    
Quad Cities 2 85   LIMITED IN POWER (STEAM DRYER MONITORING)    

Region 4

Unit Power Down Reason or Comment Change in report (*) Number of Scrams (#)
Arkansas Nuclear 1 100        
Arkansas Nuclear 2 100        
Callaway 100        
Columbia Generating Station 100        
Comanche Peak 1 100        
Comanche Peak 2 100        
Cooper 93   COASTDOWN TO REFUELING OUTAGE *  
Diablo Canyon 1 100        
Diablo Canyon 2 0 10/25/2004 REFUELING OUTAGE    
Fort Calhoun 100        
Grand Gulf 1 100        
Palo Verde 1 100        
Palo Verde 2 100        
Palo Verde 3 0 10/01/2004 PLANNED MAINTENANCE    
River Bend 1 100     *  
San Onofre 2 96   TURBINE VALVE TESTING IN PROGRESS *  
San Onofre 3 0 09/27/2004 DEFUELED    
South Texas 1 100        
South Texas 2 100        
Waterford 3 100        
Wolf Creek 1 100        

* - Power Reactor Status Report change within past 24 hours
# - Number of reactor scrams or trips within past 24 hours

Notes:
  • Reactor status data collected between 4 a.m. and 8 a.m. each day.
  • All times are based on eastern time.

Page Last Reviewed/Updated Thursday, March 25, 2021