Part 21 Report - 2001-040
Holtec Center, 555 Lincoln Drive West, Mariton, NJ 08053
Telephone (856) 797-0900
Fax (856) 797-0909
HOLTEC
INTERNATIONAL BY FAX AND OVERNIGHT MAIL
January 4, 2001
U.S. Nuclear Regulatory Commission
ATTN: Document Control Desk
Washington, DC 20555-0001
Subject: 10 CFR 21 Notification for Discrepant Weight of Spent Fuel Racks
Reference: Holtec File No. HQP 15.1.3
Dear Sir:
Pursuant to Holtec Quality Procedure HQP 15.1, "Reporting of Defects and Noncompliances per 10CFR21", Holtec International hereby notifies the Commission of a defect in the design basis input data for the analyses and design of ancillary components for spent nuclear fuel (SNF) storage racks. Holtec International is under contract to design, fabricate, and install replacement spent fuel storage racks for Exelon's Byron and Braidwood Nuclear Power Stations. Part of our contracted scope of work includes the removal and disposal of the existing racks at each plant.
The existing racks were recently removed from the Byron spent fuel pool and released to our subcontractor, Alaron Corporation, for disposal. We have been informed by Alaron that the as-found weights of each of the four removed Region 1 Byron racks (supplied by Joseph Oat Company over ten years ago) range from approximately 8,200 to 10,500 lbs greater than the weights used in the analyses supporting the licensing of the racks and the design of lifting equipment for the racks. Similarly designed racks, provided by the same supplier, are currently licensed and in use at the Braidwood Nuclear Power Plant. While small variations in rack weight are typical and within the accuracy of the supporting analyses and lifting equipment design, the magnitude of these discrepancies is unusual and brings into question the results of the previous analyses and the level of compliance of the lifting equipment design with the governing regulatory guidance (i.e., NUREG-0612). To the best of our knowledge, these racks for Byron and Braidwood were designed and fabricated by Joseph Oat Corporation of Camden, New Jersey ca. 1987. Since we are not the designer of record, we are unable to determine the actual impact of the weight discrepancy on the analyses. The Byron re-rack effort has been completed.
We have accounted for the same potential discrepancy with the Braidwood racks in the design of the lifting equipment by increasing the maximum rack weight used in the design. Braidwood site construction is ongoing. We are unable to determine whether the same type of error in rack weight exists at other nuclear plants that may have procured fuel racks from the same supplier.
The specific information required by 10 CFR 21.21(d)(4) is provided below.
Holtec Center, 555 Lincoln Drive West, Mariton, NJ 08053
Telephone (856) 797-0900
Fax (856) 797-0909
HOLTEC
INTERNATIONAL
U.S. Nuclear Regulatory Commission
ATTN: Document Control Desk
Document ID: HQP15.1.3
Page 2 of 4
Name and Address of Individual Informing the Commission:
Mr. Mark Soler
Q.A. Manager
Holtec International
Holtec Center
555 Lincoln Drive West
Mariton, NJ 08053
Identification of the Basic Component Supplied Which Contains a Defect:
The basic components are: 1) the supporting analyses for the licensing of the previous Region 1 Byron Plant spent fuel storage rack identification numbers A1, B1, B2, and B3 and 2) the lifting equipment used to lift these racks out of the spent fuel pool and move them to their designated storage location. These racks have been removed from service at Byron Plant.
Identification of the Firm Supplying the Basic Component Which Contains a Defect:
Joseph Oat Corporation
2500 Broadway
Camden, NJ 08104
Nature of the Defect and the Safety Hazard Which Could Be Created by the Defect:
Spent fuel storage racks removed from the Byron Nuclear Power Plant were discovered to have as-found weights ranging from approximately 8,200 to 10,500 lbs more than the weights used in the analyses supporting the original design and licensing of these racks and in the design of the lifting equipment used to lift the racks. The analyses related to seismic loadings, bearing pad design, spent fuel pool liner fatigue, and possibly others used to design and license these racks may no longer be conservative when the additional weight is considered. The actual impact on these analyses has not, to our knowledge, been evaluated. The impact on the design of the lifting equipment is that the design safety factors for the lifting equipment, while still above 1.0, may not meet the minimum safety factors in NUREG-0612 and associated reference documents.
Holtec Center, 555 Lincoln Drive West, Mariton, NJ 08053
Telephone (856) 797-0900
Fax (856) 797-0909
HOLTEC
INTERNATIONAL
U. S. Nuclear Regulatory Commission
ATTN: Document Control Desk
Document ID: HQP15.~.3
Page 3 of 4
The Date on Which the Information of Such Defect was Obtained:
Approximately October 18, 2000
The Number and Location(s) of the Basic Component Which Contains the Defect
There were four (4) Region 1 racks removed from the Byron spent fuel pool found to have this discrepancy. While the racks in question are no longer in service, four similarly designed racks provided by the same supplier are known to be in service at the Braidwood Nuclear Station. Since Holtec is not the supplier of the hardware with the defect, the total number and locations where the basic component is in service is unknown to us. The lifting equipment used at Byron Station is no longer in service.
The Corrective Action Which Has Been, Is Being, or Will Be Taken, Name of Individual or Organization Responsible for the Action, and the Length of Time That Has Been, or Will Be Taken to Complete the Action:
There are no corrective actions required for the racks and lifting equipment at Byron Station since they have been removed from service. We are unaware of any corrective actions planned or taken regarding the licensing basis analyses as a result of this issue at Braidwood Station or elsewhere. However, the affected Braidwood Station racks are scheduled to be removed from service by the end of April, 2001. We have accounted for the potential overweight condition with the Braidwood racks by incorporating an appropriately higher design rack weight into the design of the lifting equipment to be used to remove the racks at Braidwood Station.
Any Advice Related to the Defect about the Basic Component That Has Been, Is Being, or Will Be Given to Purchasers or Licensees:
We have informed the Byron and Braidwood Station licensee (Exelon Corporation) of the issue. While we are not the supplier of the affected racks, the design and licensing of spent fuel racks is a core business for Holtec International. It is impossible to measure the weight of the racks currently in use at Braidwood Station. These racks are scheduled to be removed in the next few months. We recommend that, for any plant having similar vintage racks from the same supplier currently in service, the licensing basis analyses be re-performed with the corrected weight to confirm whether the results continue to be valid for those installed racks. The need for additional corrective actions would be determined based on the results of this re-analysis work.
Holtec Center, 555 Lincoln Drive West, Mariton, NJ 08053
Telephone (856) 797-0900
Fax (856) 797-0909
HOLTEC
INTERNATIONAL
BY FAX AND OVERNIGHT MAIL
January 4, 2001
U. S. Nuclear Regulatory Commission
ATTN: Document Control Desk
Washington, DC 20555-0001
Page 4 of 4
If you have any questions or require additional information, please contact me at (856) 797-0900, extension 619.
Sincerely,
Mark Soler
QA Manager
Concurrence:
Licensing
Brian Gutherman, P.E.
cmcc: Mr Ken Ainger, Exelon Corp. (w/encl.)
Mr. Steven Soler, Holtec International
Enclosure: Holtec 10 CFR 21 Evaluation and related information (12 pages)
Document I.D.: HQP15.1.3
Document 809444
Enclosure 12 pages
To: Mark Soler <Mark_Soler@holtec.com>
Subject: I0CFR2I Evaluation - Byron Region 1 Racks
Mark,
In light of the recent discovery that the Joseph Oat Region I racks, which were removed from the Byron spent fuel pool, weigh approximately 10,000 pounds more than their licensed (design) weight1 Steve Soler has performed an independent 10 CFR Part 21 Evaluation. Moreover, he concluded that this deviation is reportable under 10 CFR Part 21.
In accordance with the rules of 10 CFR Part 21, we reported our conclusion to Joe Bauer of Exelon Nuclear Corp. (i.e., the equipment owner) on 11/30/00, and we suggested that Exelon perform an independent evaluation of the incident. We further advised Exelon that if they disagree with our assessment and/or they do not intend to identify this deviation to the US NRC, Holtec will be required to proceed on our own. A response was requested from Exelon to Holtec by December 11, 2000.
Today I called Joe Bauer to receive an update on this issue. During our conversation, Joe confirmed that he had discussed this issue with his colleagues and that they concluded that Holtec should notify the USNRC in accordance with Holtec's QA program.
Chuck
Charles W. Bullard II |
Phone: (856) 797-0900, Ext. 633 |
Project Engineer |
Fax: (856) 797-0909 |
Holtec International |
E-mail: Chuck_Bullard@holtec.com |
Visit our website at <http://www.holtecintemational.com >
Printed for Mark Soler <Mark_Soler@holtec.com>
Exhibit 15.1-1
10CFR21 DEVIATION AND NONCOMPLIANCE EVALUATION
BRIEFLY SUMMARIZE THE DEVIATION OR NONCONFORMING ITEM*:
Existing Region 1 style racks that were removed from the Byron spent fuel pool each was found to be approximately 10,000 pounds greater in weight than their weight listed in their related licensing submittal. These racks are also found at the Braidwood site.
DATE OF DISCOVERY:
10/11/2000
SOURCE DOCUMENT FOR DEyIATION OR NONCOMPLIANCE (E.G., AUDIT REPORT, QPVF, NCR, CAR, ETC.):
Letter received from Alaron dated 10/11/00 stating as found weights of delivered racks.
NAME AND ADDRESS OF ENTITY RESPONSIBLE FOR THE DEVIATION OR NONCOMPLIANCE:
Joseph Oat Corporation -- fabricator
I. Determination of 10 CFR 21 Applicability
Is the affected component hardware or the design, analysis, inspection, testing, fabrication, replacement of parts, or consulting services associated with the component hardware a basic component (see Definition 2.1).
YES X NO_____
BASIS:
Rack weight is an integral input for much of the supporting rack analysis.
* Include part make/model or similar identifier, as applicable.
HOLTEC QUALITY PROCEDURE 15.1 Revision 5
Page 2 of 3
10CFR2l DEVIATION AND NONCOMPLIANCE EVALUATION
If the response is 'NO", then 10 CFR 21 is not applicable to this deviation or noncompliance. The preparer and reviewer must sign this exhibit and obtain a QA concurrence signature. No further action is required.
II. Description of Deviation or Noncompliance
Provide a detailed description of the deviation or noncompliance as it relates to the basic component's ability to perform its safety flinction (see Definition 2.7).
In the processing of the existing spent fuel racks removed from the Byron site, it was discovered that each of the four Region ] racks weighed approximately JO, 000 pounds greater than the value listed in the previously submitted Licensing Amendment for these generation of racks. Though these racks have been removed from Byron, duplicate racks are presently in operation at the Braidwood facilitv. The racks were supplied by Joseph Oat Corporation. Their existence at other plants is not known.
III. Determination of 10 CFR 21 Reportability
Is the deviation or noncompliance described in Item II above a defect or failure to comply potentially involving a substantial safety hazard per 10 CFR 21 (see Definition 2.6). Pay particular attention to Definition 2.14 for Substantial Safety Hazard.
NOTE: For those occasions where it is indeterminate whether a defect or noncompliance constituting a substantial safety hazard exists, consult with the QA Manager; Licensing Manager, Vice President, Nuclear Projects; or other Holtec senior management. If after discussion with Holtec management, the issue is still indeterminate and no further evaluation can be performed in a timely manner, check "YES" and report the issue to the NRC. Describe the issue as a "potential" defect or failure to comply potentially involving a substantial safety hazard in the basis below.
YES X NO_____
HOLTEC QUALITY PROCEDURE 15.1 Revision 5
Page 3 of 3
BASIS:
If the increased rack weight was not factored into the design basis, analyses related to seismic evaluation, bearing pad analysis, liner fatigue, etc. may not be conservative.
10CFR21 DEVIATION AND NONCOMPLIANCE EVALUATION
IV. Conclusion
The deviation/noncompliance IS reportable under 10 CFR 21
(Signed 11/10/00) |
(Signed 11/14/00) |
Preparer Signature/Date |
Reviewer Signature/Date |
The deviation/noncompliance IS NOT reportable under 10 CFR 21
Preparer Signature/Date |
Reviewer Signature/Date |
(Signed 11/14/00)
QA Manager Concurrence Signature/Date
Table 2.2
MODULE DATA (From license submittal)
(see image file for this Part 21 report)
2-3
FIGURE 2.1 POOL LAYOUT (From license submittal)
(see image file for this Part 21 report)
2-4
BYRON EXISTING RACK INFORMATION PER ALARON
(see image file for this Part 21 report)
ALARON CORPORATION
October 18, 2000
Holtec International
Holtec Center
555 Lincoln Drive West
Mariton, New Jersey 08053
Attn. Mr. Steven Soler
Mr. Soler:
Alaron offers the following additional data on weight determination of the fuel racks from the Byron Nuclear Station.
Weights were determined using calibrated scales. See the attached calibration certificates from Youngstown Scale. The scales are calibrated on six month intervals in addition, Mr. Dave Puhalla of Alaron is a certified weigh master in the State of Pennsylvania. This certification is required for scales that are directly used in commerce.
Method of weight determination is as follows..
1) Containment Areas cleaned and inspected to be free of debris
2) Single fuel rack is loaded into the containment
3) Disposal boxes are weighed to determine their tare weight and placed inside the containment
4) The rack is sectioned and loaded into the boxes.
5) ONLY rack material is loaded into the boxes which includes chevron, base plates and slag from cutting.
6) The filled box is weighed upon removal from the containment.
7) If a partial box is generated upon completion of a rack, it is weighed then replaced into the containment.
8) The net weights of each box are summed to determine the actual incoming rack weight.
This methodology has been used at Alaron for many years and has withstood scrutiny several times in situations such as this.
RD#2, BOX 2140A |
6359 DERBY SHIRE LANE |
WAMPUM, PENNSYLVANIA 16157 |
LOVELAND, OHIO 45140 |
(724) 535-5777 |
(513) 583-1744 |
FAX (724) 535-1165 |
FAX (513) 583-8505 |
E-mail: alaronwm@ccia.com |
E-mail: alaronsmf@aol.com |
The trucking company that hauled the racks does not have weigh slips available for each rack shipment. No lead shielding weights were included in the rack weights. The shielding was removed prior to moving the rack into containment.
If you have any questions, please call.
Sincerely,
Joseph M. Harverson
President
Youngstown Scal
P.O. Box 2403
Youngstown, OH 44509
(330)744-1333 or (800)222-6750
Scale Test Record
(see image file for this Part 21 report-3 pages)
Page Last Reviewed/Updated Wednesday, March 24, 2021