Part 21 Report - 1999-420
LICENSEE: |
SWAGELOK COMPANY |
|
|
|
SITE: |
SWAGELOK COMPANY |
|
EN NUMBER: |
36263 |
DOCKET: |
|
|
EVENT DATE: |
10-04-99 |
RX TYPE: |
|
|
EVENT TIME: |
|
VENDORS: |
|
|
NOTIFY DATE: |
10-06-99 |
EMERGENCY CLASS: |
N/A |
REGION: 3 |
STATE: OH |
TIME: 09:48 |
OPS OFFICER: |
LEIGH TROCINE |
|
|
|
10 CFR SECTION: |
CCCC UNSPECIFIED PARAGRAPH |
POSSIBLE 10-CFR-PART-21 REPORT REGARDING A POSSIBLE DEFECT IN A SWAGELOK TUBE FITTING
The following text is a portion of a facsimile submitted by Swagelok Company:
"This is a preliminary notification of a possible defect in a Swagelok tube fitting, part number SS-400-3-4TTM, male branch tee. A drawing of the part is included with this notification. We are also notifying each of the involved utilities."
"We became aware of this on October 4, 1999."
"The defect is a crack in the seat of the fitting. We are continuing our analysis of the part and will provide further details in accordance with NRC timetables."
"[The] following are the six utilities to whom we have sold these parts:
Georgia Power [Company], |
Plant Vogtle, |
... , |
10 pcs. ... [;] |
Duke Power Company, |
Oconee Nuclear Station, |
... , |
100 pcs. ... [;] |
Arizona Public Service Co., |
Palo Verde Nuclear Generating Station, |
... , |
15 pcs. ... [;] |
North Atlantic Energy Service Co., |
Seabrook Station, |
... , |
10 pcs. ... [;] |
Virginia Power, |
Surry Power Station, |
... , |
3 pcs. ... [; and] |
Omaha Public Power District, |
Ft. Calhoun Nuclear Station, |
... , |
10 Pcs. ... ." |
(Call the NRC operations officer for Swagelok contact information.)
Page Last Reviewed/Updated Thursday, March 25, 2021