Part 21 Report - 1998-661


ACCESSION #: 9810160221


150 Lincoln Avenue
Grove City, PA 15127-1898
Tel 412 458-8000
Fax 412 458-3574

Ajax [Registered Trademark]

 
COOPER Coberra [Registered Trademark]
ENERGY SERVICES Cooper-Bessemer [Registered Trademark]
Enterprise [Trademark]
En-Tronic [Registered Trademark]
Penn [Trademark]
Superior [Registered Trademark]
October 13, 1998 FAX: 301-816-5151
 
Our Ref: QCG-10513 (K5fa45)

Document Control Desk
U.S. Nuclear Regulatory Commission
Washington, D.C. 20555

Subject: 10 CFR 21 Notification, Ar Start Distributor Filter Micron Rating Evaluation and Interim Report - Enterprise DSR-4 and DSRV-4 Emergency Diesel Engine

Dear Sir:

In accordance with the requirements of the Nuclear Regulatory Commission Title 10, Chapter 1, Code of Federal Regulations, Part 21, Cooper Energy Services (CES), a division of Cooper Cameron Corporation, provides initial notification and an interim report of a 10CFR Part 21 evaluation being conducted by Cooper Energy Services,

Our investigation is of a starting air distributor filter element provided as replacement part components for the Enterprise R4 and RV4 emergency diesel generator system. The Cooper-Bessemer part number of the filter cartridge is SB-006-002.

Discussion:

During the commercial grade dedication process, filter elements from multiple suppliers were pulled from stores and inspected for nuclear safety related application. The variation in the color and the lack of some filter elements having the micron rating stamped on them prompted an investigation as to the actual micron rating.

We are in the process of performing independent lab testing to ascertain whether filter elements of an incorrect micron rating have been provided to any of our nuclear customers. It is expected that this evaluation will be completed on or before November 30, 1998.


Page 2

October 13, 1998

QCG-10513

If you have any questions or comments, please contact Ted Miller at 724-458-3448 or Ron Billig at 724-458-3584.

Sincerely,

COOPER ENERGY SERVICES

Peter DeFronzo
General Manager

TLM/kil

Copies to:

Mr. Stephen Alexander
Nuclear Regulatory Commission
QA Vendor Insp. & Maintenance Branch
One White Flint North
Mailstop 9A1
Washington, DC 20555

FILE: K5fa 45


GENERAL INFORMATION or OTHER EVENT NUMBER: 34914
LICENSEE: COOPER ENERGY SERVICES NOTIFICATION DATE: 10/14/98
CITY: GROVE CITY REGION: 1 NOTIFICATION TIME: 15:05 [ET]
COUNTY: STATE: PA EVENT DATE: 10/13/98
LICENSE#: AGREEMENT: N EVENT TIME: 00:00 [EDT]
DOCKET: LAST UPDATE DATE: 10/14/98
NOTIFICATIONS CURT COWGILL RDO
NRC NOTIFIED BY: TED MILLER VERN HODGE, PCEB NRR
HQ OPS OFFICER: JOHN MacKINNON
EMERGENCY CLASS: NOT APPLICABLE
10 CFR SECTION: CCCC 21.21 UNSPECIFIED PARAGRAPH

EVENT TEXT

PART 21 NOTIFICATION REGARDING THE AIR START DISTRIBUTOR FILTER MICRON RATING EVALUATION AND INTERIM REPORT - ENTERPRISE DSR-4 AND DSRV-4 EMERGENCY DIESEL ENGINE.

THE FOLLOWING IS A PORTION OF A FACSIMILE RECEIVED:

"OUR INVESTIGATION IS OF A STARTING AIR DISTRIBUTOR FILTER ELEMENT PROVIDED AS REPLACEMENT PART COMPONENTS FOR THE ENTERPRISE R4 AND RV4 EMERGENCY DIESEL GENERATOR SYSTEM. THE COOPER-BESSEMER PART NUMBER OF THE FILTER CARTRIDGE IS SB-006-002"

DISCUSSION:

"DURING THE COMMERCIAL GRADE DEDICATION PROCESS, FILTER ELEMENTS FROM MULTIPLE SUPPLIERS WERE PULLED FROM STORES AND INSPECTED FOR NUCLEAR SAFETY RELATED APPLICATION. THE VARIATION IN THE COLOR AND THE LACK OF SOME FILTER ELEMENTS HAVING THE MICRON RATING STAMPED ON THEM PROMPTED AN INVESTIGATION AS TO THE ACTUAL MICRON RATING"

WE ARE IN THE PROCESS OF PERFORMING INDEPENDENT LAB TESTING TO ASCERTAIN WHETHER FILTER ELEMENTS OF AN INCORRECT MICRON RATING HAVE BEEN PROVIDED TO ANY OF OUR NUCLEAR CUSTOMERS. IT IS EXPECTED THAT THIS EVALUATION WILL BE COMPLETED ON OR BEFORE NOVEMBER 30, 1998."


*** END OF DOCUMENT ***

Page Last Reviewed/Updated Thursday, March 25, 2021