Part 21 Report - 1997-842
ACCESSION #: 9712300095
Paul H. Kinkel
Vice President
Consolidated Edison Company of New York, Inc.
Indian Point Station
Broadway & Bleakley Avenue
Buchanan, NY 10511
Telephone (914) 734-5340
Fax: (914) 734-5923
December 17, 1997
Re: Indian Point Unit No. 2
Docket No. 50-247
Document Control Desk
US Nuclear Regulatory Commission
Mail Station P1-137
Washington, DC 20555
SUBJECT: 10 CFR Part 21 Written Notification
On November 17, 1997, Con Edison submitted, by facsimile, the initial
notification of a condition at Indian Point Unit No. 2 which we
determined to be reportable under the requirements of 10 CFR Part 21.
The reported condition involved a defect in environmentally qualified
Motor Operated Valves which had been installed at the plant. Subsequent
to that initial notification, we have learned of further test data that
appears to conclude that the MOVs were operable regardless of the defect.
However, since we have not yet fully analyzed this test data and
determined that we are in full agreement with the conclusion based on
that data, we are conservatively submitting this report under Part 21.
The requirements of 10 CFR 21.21 (d)(4) identify specific information to
be included in this written notification. That information is provided
in the attachment to this letter.
Should you have any questions regarding this matter, please contact Mr.
Charles W. Jackson, Manager, Nuclear Safety and Licensing.
Very truly yours,
C: Mr. Hubert J. Miller
Regional Administrator - Region I
US Nuclear Regulatory Commission
475 Allendale Road
King of Prussia, PA 19406
Mr. Jefferey F. Harold, Project Manager
Project Directorate I-1
Division of Reactor Projects I/II
US Nuclear Regulatory Commission
Mail Stop 14B-2
Washington, DC 20555
Senior Resident Inspector
US Nuclear Regulatory Commission
PO Box 38
Buchanan, NY 10511
ATTACHMENT
Indian Point Unit No. 2 - Defective MOV T-Drains
The following information is provided as required by 10 CFR 21.21 (d)(4).
(i) Name and address of individual informing the Commission.
Paul Kinkel, Vice President - Nuclear Power
Consolidated Edison Company of New York, Inc. Indian Point Unit
No. 2
Broadway and Bleakley Ave.
Buchanan, NY 10511
(ii) Identification of the basic component which contains a defect.
Component: Motor Operator
Model: SB-00-25; SMB-00-25; SMB-00-15; SMB-00; SMB-000
(iii) Identification of the firm supplying the basic component which
contains a defect. Limitorque Corporation, Lynchburg, VA
(iv) Nature of the defect and the safety hazard which could be
created by such a defects.
T-drain not drilled through vertically and would act as a pipe
plug. Condensation buildup inside the motor would not be
relieved resulting in possible degraded motor performance.
BACKGROUND
(v) The date on which the information of such defect was obtained.
Concerns regarding the quality of the Limitorque T-Drains were
raised initially on May 21, 1997. In accordance with Company
procedures, a determination that this component may fall in the
scope of Part 21 was made on September 15, 1997 and a formal
evaluation commenced. The evaluation was completed on November
17, 1997 and communicated by facsimile under Part 21 on that
day.
(vi) In the case of a basic component which contains a defect, the
number and location of all such components in use at the
facility subject to the regulations in this part. Seven total,
four located in the Primary Auxiliary Building and three
located in containment.
(vii) The corrective action which has been taken. The improperly
drilled T-drains were replaced with correctly drilled T-drains.
(viii) Any advice related to the defect that has been given to
purchasers or licensees. Informal discussions with several
licensees.
*** END OF DOCUMENT ***