Part 21 Report - 1997-771
ACCESSION #: 9710170102
DuBose
National Energy Services, Inc.
October 15, 1997
Attn: NRC Operations Center
Document Control Desk
US Nuclear Regulatory Commission
Washington, DC 20555
Subject: Potential 10 CFR 21
Dear Sir;
This letter is to inform you of a potential safety hazard for some 3/4
Sch 40 pipe shipped to two or our customers, Carolina Power & Light and
Virginia Power Corp. This material has been found, to have areas where
the wall thickness falls below the minimum allowed by the SA 312
specification. When the material was cut by Virginia Power Corp at their
North Anna site this condition was found. The minimum wall thickness of
.099 had been violated. Some of the readings were as low as .087.
A sample of this material has been returned to Sandvik Steel, the
producer, in Scranton, PA, for evaluation.
The orders were for 3/4, schedule 40, Pipe SA 312, type 304. Carolina
Power & Light, PO #8N7398CJ had one piece 23' 11" and PO #8P8410CJ had 2
pieces totaling 46' 11", all of this material came from heat 946989.
The Virginia Power Corp orders were #CNT-552587, CNT-55-601 1, & CNT-
558917 for one piece each of 3/4 schedule 40 Pipe, SA 312, type 304.
Each piece was 22' to 23' 6" random length from heat #46989.
(910) 590-2151 o 1-800-590-2150 o FAX (910) 590-3555
P.O. Box 499 a Clinton, NC 28328
Each of these customer has been notified and we will notify them of any
information received from the producer of the pipe, when it is available.
If I can be of any further assistance you may contact me at 1-800-590-
2150.
Sincerely,
James N. Dailey
QA Manager
copy: Carl Rogers, President
VP Sales
Sales Manager
GENERAL INFORMATION or OTHER EVENT NUMBER: 33088
LICENSEE: DUBOSE NATIONAL ENERGY NOTIFICATION DATE: 10/15/97
SERVICE INC
CITY: CLINTON REGION: 2 NOTIFICATION TIME: 15:06 [ET]
COUNTY: STATE: NC EVENT DATE: 10/15/97
LICENSE#: AGREEMENT: Y EVENT TIME: 00:00[EDT]
DOCKET: LAST UPDATE DATE: 10/15/97
NOTIFICATIONS
THOMAS PEEBLES RDO
NRC NOTIFIED BY: DAILEY(FAX) VERN HODGE NRR
HQ OPS OFFICER: CHAUNCEY GOULD
EMERGENCY CLASS: NOT APPLICABLE
10 CFR SECTION:
CCCC 21.21 UNSPECIFIED PARAGRAPH
EVENT TEXT
DUBOSE NATIONAL ENERGY SERVICES INC SUBMITTED A POTENTIAL PART 21
REPORT.
THE "DEFECT" IN QUESTION IS SOME 3/4" SCH 40 PIPING WHICH MAY HAVE WALL
THICKNESS AS LOW AS .087" WHEN THE MINIMUM ALLOWED BY SA 312
SPECIFICATIONS IS .099". THIS PIPING WAS SHIPPED TO CAROLINA POWER &
LIGHT AND VIRGINIA POWER AND THE NORTH ANNA SITE DISCOVERED THIS
CONDITION. THEY HAVE RETURNED A SAMPLE OF MATERIAL TO THE
PRODUCER,
SANDVIK STEEL, FOR EVALUATION. BOTH SHIPMENTS OF PIPING TO THE TWO
CUSTOMERS HAD THE SAME HEAT #46989. THE CUSTOMERS HAVE BEEN
NOTIFIED.
*** END OF DOCUMENT ***