Part 21 Report - 1997-558
ACCESSION #: 9712040205
The Boeing Company
P.O. Box 3707
Seattle, WA 98124-2207
November 26, 1997
G-1151-SJA-97-564
Document Control Desk
United States Nuclear Regulatory Commission
Washington, D.C. 20555
Reference: a) Boeing Letter G-1151-RSO-92-365 dated August 31,
1992; R. S. Orr to the NRC Operations Center
BOEING
b) NRC Letter Docket No. 99901227 dated August 12, 1992;
L. J. Norrholm to R. S. Orr; Subject: Response to 10
CFR 21 Inquiry
Dear Sir or Madam:
In accordance with the reference correspondence and 10 CFR 21, Boeing is
sending the NRC the attached error notice(s) received from our former
software suppliers. Because of unknown current addresses, the following
former customers were not notified:
Reactor Controls, Inc.
Echo Energy Consultants, Inc.
Nuclear Applications and Systems Analysis Company (Japan)
Nuclear Power Services
Error notices have been sent to our other former customers.
Very truly yours,
Sandra J. Andrews
Nuclear Administrator
Phone: (206) 865-6248
FAX: (206) 865-4851
Mail Stop: 7A-33, or
e-mail: Sandra.Andrews@PSS.Boeing.com
Enclosure(s): GTSTRUDL Program Report Form 97.18
Georgia Institute
of Technology GT STRUDL [Registered copy]
November 17, 1997
Attention: Nuclear Administrator
Boeing Information & Support Services
P.O.Box 24346, M/S 7A-33
Seattle, Washington 98124-0346
RE: GT STRUDL
Dear Sir or Madam:
Enclosed please find copies of GTSTRUDL PROGRAM REPORT FORM 97.17 and a
GTSTRUDL QA CUSTOMER ACKNOWLEDGEMENT FORM. Please sign and return the
GTSTRUDL QA CUSTOMER ACKNOWLEDGEMENT FORM to acknowledge receipt of the
GTSTRUDL Program Report.
Thank you for reviewing the Program Report and for returning the
Acknowledgement Form.
Best regards,
CASE Center
David C. Key
Configuration Control Manager
Enclosures
Computer Aided Structural Engineering Center Phone: (404) 894-2670
School of Civil & Environmental Engineering Fax: (404) 894-8014
Atlanta, Georgia 30332-0355 USA casec@ce.gatech.edu
A Unit of the University System of Georgia
GTSTRUDL Program Report Form
GPRF No.:
FROM: Computer-Aided Structural Engineering Center DATE:
Georgia Institute of Technology
Atlanta, Georgia 30332-0355
SEVERITY LEVEL:
_ URGENT Problem results in incorrect answers which may not be
apparent or job aborts and cannot be recovered within the
session or job.
_ SERIOUS Problem results in incorrect answers which are obvious or
problem prevents completion of a particular user's task.
_ MINOR Problem can be worked around or problem poses high
frustration factor.
_ INFORMATIVE Documentation error, program usage tip, user
inconveniences.
Date Problem Confirmed
Date Notification Sent
Computers
Operating System
Version
Target Release for Correction
Signature Title
R & D Division
Typed or Printed Name Date of Signature
Signature Title
Professional Services Division
Typed or Printed Name Date of Signature
Rev 2.2
GTSTRUDL Program Report Form
(Continued)
GPRF No.:
DATE:
DESCRIPTION:
If rigid bodies (TYPE RIGID PIN, etc.) exist, the DBX commands WRITE
MEMBER ATTRIBUTES, WRITE MEMBER CONSTANTS, WRITE MEMBER
PROPERTIES, WRITE
SECTION FORCES, and WRITE SECTION DISPLACEMENTS will abort if the rigid
bodies are in the member list.
Workarounds:
1. Use the explicit member list option (not "ALL MEMBERS") and exclude
the rigid bodies.
2. Inactivate the rigid bodies and use the ALL ACTIVE MEMBERS option.
Documentation:
Section 2, "The WRITE Command", Volume 5, GTSTRUDL User Reference Guide.
Section 2.1.3.4, "ACTIVE/INACTIVE Structure Specifications", Volume 1,
GTSTRUDL Users Reference Guide.
Rev 2.2
*** END OF DOCUMENT ***