Part 21 Report - 1997-553
ACCESSION #: 9709300328
Information & Support Services
P.O. Box 3707
Seattle, WA 98124-2207
BOEING
September 24, 1997
G-1151 -SJA-97-442
Document Control Desk
United States Nuclear Regulatory Commission
Washington, D.C. 20555
Reference: a) Boeing Letter G-1151-RSO-92-365 dated August 31, 1992; R.
S. Orr to the NRC Operations Center
b) NRC Letter Docket No. 99901227 dated August 12, 1992; L.
J. Norrholm to R. S. Orr; Subject: Response to 10 CFR 21
Inquiry
Dear Sir or Madam:
In accordance with the reference correspondence and 10 CFR 21, Boeing is
sending the NRC the attached error notice(s) received from our former
software suppliers. Because of unknown current addresses, the following
former customers were not notified:
Reactor Controls, Inc.
Echo Energy Consultants, Inc.
Nuclear Applications and Systems Analysis Company (Japan)
Nuclear Power Services
Error notices have been sent to our other former customers.
Very truly yours,
Sandra J. Andrews
Nuclear Administrator
Phone: (206) 865-6248
FAX: (206) 865-4851
Mail Stop: 7A-33, or
e-mail: Sandra.Andrews@PSS.Boeing.com
Enclosure(s): GTSTRUDL Program Report Forms 97.13, 97.14, 97.15
Georgia Institute
of Technology GT STRUDL Trade Mark
September 16, 1997
Attention: Nuclear Administrator
Boeing Information & Support Services
P.O. Box 24346, M/S 7A-33
Seattle, Washington 98124-0346
RE: GT STRUDL
Dear Sir or Madam:
Enclosed please find copies of GTSTRUDL PROGRAM REPORT FORM 97.13, 97.14,
97.15 and a GTSTRUDL QA CUSTOMER ACKNOWLEDGEMENT FORM. Please sign and
return the GTSTRUDL QA CUSTOMER ACKNOWLEDGEMENT FORM to acknowledge
receipt of the GTSTRUDL Program Report.
Thank you for reviewing the Program Report and for returning the
Acknowledgement Form.
Best regards,
CASE Center
David C. Key
Configuration Control Manager
Enclosures
Computer Aided Structural Engineering Center Phone: (404) 894-2260
School of Civil & Environmental Engineering Fax: (404) 894-8014
Atlanta, Georgia 30332-0355 USA casec@ce.gatech.edu
A Unit of the University System of Georgia
GTSTRUDL Program Report Form
GPRF No.:
DATE:
FROM: Computer-Aided Structural Engineering Center
Georgia Institute of Technology
Atlanta, Georgia 30332-0355
SEVERITY LEVEL:
URGENT Problem results in incorrect answers which may not be
apparent or job aborts and cannot be recovered within
the session or job.
SERIOUS Problem results in incorrect answers which are
obvious or problem prevents completion of a
particular user's task.
MINOR Problem can be worked around or problem poses high
frustration factor.
INFORMATIVE Documentation error, program usage tip, user
inconveniences.
Date Problem Confirmed
Date Notification Sent
Computers
Operating System
Version
Target release for Correction
Signature Title
R & D Division
Typed or Printed Name Date of Signature
Signature Title
Professional Services Division
Typed or Printed Name Date of Signature
Rev 2.2
GTSTRUDL Program Report Form
(continued)
GPRF No.:
DATE:
DESCRIPTION:
In GTMenu, Edit Joint, Member, or Element ID's may
cause STRUDL to abort for joints, members, or elements with
alphanumeric names.
As a work-around, the joints, members, or elements
must be deleted and then respecified.
relevant documentation:
GTSTRUDL User's Manual, volume 6, sections 13.4.1, 13.4.2,
13.4.3
Rev 2.2
GTSTRUDL Program Report Form
GPRF No.:
DATE:
FROM: Computer-Aided Structural Engineering Center
Georgia Institute of Technology
Atlanta, Georgia 30332-0355
SEVERITY LEVEL:
URGENT Problem results in incorrect answers which may not be
apparent or job aborts and cannot be recovered within
the session or job.
SERIOUS Problem results in incorrect answers which are
obvious or problem prevents completion of a
particular user's task.
MINOR Problem can be worked around or problem poses high
frustration factor.
INFORMATIVE Documentation error, program usage tip, user
inconveniences.
Date Problem Confirmed
Date Notification Sent
Computers
Operating System
Version
Target release for Correction
Signature Title
R & D Division
Typed or Printed Name Date of Signature
Signature Title
Professional Services Division
Typed or Printed Name Date of Signature
Rev 2.2
GTSTRUDL Program Report Form
(Continued)
GPRF No:
DATE:
DESCRIPTION:
In GTMenu, Edit Member Beta Angle does not work when
the members are specified in LIST mode.
As a work-around, select the members using HIT mode.
relevant documentation:
GTSTRUDL User's Manual, volume 6, section 13.4.2
Rev 2.2
GTSTRUDL Program Report Form
GPRF No.:
DATE:
FROM: Computer-Aided Structural Engineering Center
Georgia Institute of Technology
Atlanta, Georgia 30332-0355
SEVERITY LEVEL:
X URGENT Problem results in incorrect answers which may not be
apparent or job aborts and cannot be recovered within
the session or job.
SERIOUS Problem results in incorrect answers which are
obvious or problem prevents completion of a
particular user's task.
MINOR Problem can be worked around or problem poses high
frustration factor.
INFORMATIVE Documentation error, program usage tip, user
inconveniences.
Date Problem Confirmed September 12, 1997
Date Notification Sent
Computers PC
Operating System DOS, NT, Windows 95
Version 94.01 and later
Target release for Correction 97.01 Mod 1
Mgr. ASD
Signature Title
R & D Division
Michael H. Swanger
Typed or Printed Name Date of Signature
Signature Title
Professional Services Division
Typed or Printed Name Date of Signature
Rev 2.2
GTSTRUDL Program Report Form
(Continued)
GPRF No:
DATE:
DESCRIPTION:
The STIFFNESS ANALYSIS command will abort if member elastic end
connections are defined, two or more independent loading conditions
are active, and at least one of these loading conditions has member
loads.
A work-around is to execute the STIFFNESS ANALYSIS command for
each load individually as follows:
LOAD LIST 1
STIFFNESS ANALYSIS
LOAD LIST 5
STIFFNESS ANALYSIS
This procedure may be performed more efficiently by LOAD LISTing as
a group all loads which do not contain member loads. Loadings which
do contain member loads must be processed individually.
GTSTRUDL User Reference Manual Sections:
The MEMBER RELEASES Command Section 2.1.8.2, Volume 1, Rev. P
Rev. 2.2
*** END OF DOCUMENT ***
Page Last Reviewed/Updated Wednesday, March 24, 2021