Part 21 Report - 1997-552
ACCESSION #: 9709170210
Information & Support Services
P.O. Box 3707
Seattle, WA 98124-2207
September 12, 1997
G-1151-SJA-97-426
Document Control Desk
United States Nuclear Regulatory Commission
Washington, D.C. 20555
Reference: a) Boeing Letter G-1151-RSO-92-365 dated August 31,
1992; R. S. Orr to the NRC Operations Center
b) NRC Letter Docket No. 99901227 dated August 12, 1992;
L. J. Norrholm to R. S. Orr; Subject: Response to 10
CFR 21 Inquiry
Dear Sir or Madam:
In accordance with the reference correspondence and 10 CFR 21, Boeing is
sending the NRC the attached error notice(s) received from our former
software suppliers. Because of unknown current addresses, the following
former customers were not notified:
Reactor Controls, Inc.
Echo Energy Consultants, Inc.
Nuclear Applications and Systems Analysis Company (Japan)
Nuclear Power Services
Error notices have been sent to our other former customers.
Very truly yours,
Sandra J. Andrews
Nuclear Administrator
Phone: (206) 865-6248
FAX: (206) 865-4851
Mail Stop: 7A-33, or
e-mail: Sandra.Andrews@PSS.Boeing.com
Enclosure(s): GTSTRUDL Program Report Forms 97.10., 97.11 and 97.12
Georgia Institute
of Technology GT TRUDL [Registered Copy]
SEP 10 1997
September 3, 1997
Attention: Nuclear Administrator
Boeing Information & Support Services
P.O.Box 24346, M/S 7A-33
Seattle, Washington 98124-0346
RE: GT STRUDL
Dear Sir or Madam:
Enclosed please find copies of GTSTRUDL PROGRAM REPORT FORM 97.10, 97.11,
97.12 and a GTSTRUDL QA CUSTOMER ACKNOWLEDGEMENT FORM. Please sign and
return the GTSTRUDL QA CUSTOMER ACKNOWLEDGEMENT FORM to acknowledge
receipt of the GTSTRUDL Program Report.
Thank you for reviewing the Program Report and for returning the
Acknowledgement Form.
Best regards,
CASE Center
David C. Key
Configuration Control Manager
Enclosures
Computer Aided Structural Engineering Center Phone: (404) 894-2260
School of Civil & Environmental Engineering Fax: (404) 894-8014
Atlanta, Georgia 30332-0355 USA casec@ce.gatech.edu
A Unit of the University System of Georgia
GTSTRUDL Program Report Form
GPRF No.:
DATE:
FROM: Computer-Aided Structural Engineering Center
Georgia Institute of Technology
Atlanta, Georgia 30332-0355
SEVERITY LEVEL:
X URGENT Problem results in incorrect answers which may not be
apparent or job aborts and cannot be recovered within the
session or job.
_ SERIOUS Problem results in incorrect answers which are obvious or
problem prevents completion of a particular user's task.
_ MINOR Problem can be worked around or problem poses high
frustration factor.
_ INFORMATIVE Documentation error, program usage tip, user
inconveniences.
Date Problem Confirmed August 22, 1997
Date Notification Sent
Computers All
Operating System All
Version 94.01 and later
Target Release for Correction 97.01 Mod 1
Mgr. ASD
Signature Title
R & D Division
Michael H. Swanger
Typed or Printed Name Date of Signature
Signature Title
Professional Services Division
Typed or Printed Name Date of Signature
Rev. 2.2
GTSTRUDL Program Report Form
(Continued)
GPRF No.:
DATE:
DESCRIPTION:
The PERFORM CABLE PRESTRESS ANALYSIS command aborts if joint
coordinates are missing for any node of any IPCABLE element specified in
the INCLUDE ELEMENTS options of the DEFINE CABLE NETWORK commands. There
is no work around other than to make certain that joint coordinates are
specified for all IPCABLE elements in the model.
GTSTRUDL User Reference Manual Sections:
Nonlinear Static Analysis of Cable Section 2.6.3, Volume
Structure 3, Rev. P
Rev. 2.2
GTSTRUDL Program Report Form
GPRF No.:
DATE:
FROM: Computer-Aided Structural Engineering Center
Georgia Institute of Technology
Atlanta, Georgia 30332-0355
SEVERITY LEVEL:
X URGENT Problem results in incorrect answers which may not be
apparent or job aborts and cannot be recovered within the
session or job.
_ SERIOUS Problem results in incorrect answers which are obvious or
problem prevents completion of a particular user's task.
_ MINOR Problem can be worked around or problem poses high
frustration factor.
_ INFORMATIVE Documentation error, program usage tip, user
inconveniences.
Date Problem Confirmed September 2, 1997
Date Notification Sent
Computers All
Operating System All
Version 94.01 and later
Target Release for Correction 97.01 Mod 1
Mgr. ASD
Signature Title
R & D Division
Michael W Swanger
Typed or Printed Name Date of Signature
Signature Title
Professional Services Division
Typed or Printed Name Date of Signature
Rev. 2.2
GTSTRUDL Program Report Form
(Continued)
GPRF No.:
DATE:
DESCRIPTION:
Stress results produced by the LIST CABLE ANALYSIS RESULTS and LIST
STRESS commands are incorrect for the IPCABLE element if there are any
element loads, including self weight from the ELEMENT PROPERTIES command,
defined for the element. This error can be verified by comparing the
element stress results at the starting or ending element node produced by
these commands to the stress at the starting or ending node computed by
the following relationship:
Equation "1" omitted
where,
F sub x = global X nodal force at starting or ending node,
F sub y = global Y nodal force at starting or ending node,
F sub z = global Z nodal force at starting or ending node,
AX = element cross section area.
The magnitude of the percent stress error at the starting or ending
node of the element can be estimated from the following relationship:
Equation "2" omitted.
where,
Symbol omitted sub err = percent stress error estimate,
f sub x = total global X IPCABLE element load,
f sub y = total global Y IPCABLE element load,
f sub z = total global Z IPCABLE element load,
Symbol omitted = element starting or ending nodal stress
from Eq. 1.
Rev. 2.2
As a work-around, the stress at the starting or ending node of an
IPCABLE element can be computed from Eq. 1.
GTSTRUDL User Reference Manual Sections:
Nonlinear Static Analysis of Cable Section 2.6.3, Volume 3,
Structure Rev. P
The LIST Command for Finite Element Section 2.3.7.1, Volume 3,
Results Rev. D
Rev. 2.2
GTSTRUDL Program Report Form
GPRF No.:
DATE:
FROM: Computer-Aided Structural Engineering Center
Georgia Institute of Technology
Atlanta, Georgia 30332-0355
SEVERITY LEVEL:
X URGENT Problem results in incorrect answers which may not be
apparent or job aborts and cannot be recovered within the
session or job.
_ SERIOUS Problem results in incorrect answers which are obvious or
problem prevents completion of a particular user's task.
_ MINOR Problem can be worked around or problem poses high
frustration factor.
_ INFORMATIVE Documentation error, program usage tip, user
inconveniences.
Date Problem Confirmed September 2, 1997
Date Notification Sent
Computers PC
Operating System DOS, NT, Windows 95
Version 94.01 and later
Target Release for Correction 97.01 Mod 1
Mgr. ASD
Signature Title
R & D Division
Michael H. Swanger
Typed or Printed Name Date of Signature
Signature Title
Professional Services Division
Typed or Printed Name Date of Signature
Rev. 2.2
GTSTRUDL Program Report Form
(Continued)
GPRF No.:
DATE:
DESCRIPTION:
Nonlinear analysis will abort if variable members are active in the
model. A work-around is to use additional joints and members to model
variable member properties.
GTSTRUDL User Reference Manual Sections:
The MEMBER PROPERTIES Command Section 2.1.9.2, Volume 1, Rev. M
Rev. 2.2
*** END OF DOCUMENT ***