Part 21 Report - 1997-500
LICENSEE: BALTIMORE GAS & ELEC CO.
SITE: CALVERT CLIFFS 1 2 EN NUMBER:32621
DOCKET: 05000317 05000318 EVENT DATE: 06-06-97
RX TYPE: PWR PWR EVENT TIME: 00:00
VENDORS: CE CE NOTIFY DATE: 07-14-97
EMERGENCY CLASS: N/A REGION: 1 STATE: MD TIME: 14:11
OPS OFFICER: STEVE SANDIN
10 CFR SECTION: CCCC 21.21 UNSPECIFIED PARAGRAPH
UNIT SCRAM RX INIT INITIAL MODE CURR CURRENT MODE
CODE CRIT PWR PWR
1 N Y 100 POWER OPERATION 100 POWER OPERATION
2 N Y 99 POWER OPERATION 99 POWER OPERATION
THE LICENSEE IS MAKING A 10 CFR PART 21 NOTIFICATION.
THE LICENSEE IDENTIFIED THAT THE RECENTLY INSTALLED MAIN STEAM
HEADER RADIATION MONITORS, EXTENDED GAMMA SCINTILLATION
DETECTORS
SUPPLIED BY NUCLEAR RESEARCH CORPORATION, MODEL #MD-55E(V3),
FAILED A CHECK SOURCE VERIFICATION UNDER NORMAL OPERATING
CONDITIONS WITH AMBIENT TEMPERATURES BETWEEN 110�F AND 120�F.
THE DESIGN SPECIFICATION REQUIRES OPERATION UP TO 170�F, WHICH IS
WITHIN THE VENDOR SUPPLIED OPERATING RANGE OF -22�F TO 194�F. THE
PROBLEM APPEARS TO BE RELATED TO THE TEMPERATURE COMPENSATION OF
THE DETECTORS. THE DETECTORS WERE DECLARED INOPERABLE AND
REMOVED
FOR REPAIR AT THE VENDOR'S FACILITY. THIS PLACES BOTH UNITS IN
TECHNICAL SPECIFICATION 3.3.3.1, ACTION STATEMENT (30), AND IN
THE EMERGENCY RESPONSE PLAN IMPLEMENTATION PROCEDURES WHICH
ALLOWS AN ALTERNATE METHOD OF MONITORING EFFLUENT NOBLE GAS IN
THE RESPECTIVE MAIN STEAM HEADER.
THE LICENSEE PLANS TO INFORM THE NRC RESIDENT INSPECTOR.
Page Last Reviewed/Updated Wednesday, March 24, 2021