10 CFR PART 21 REPORT -
GE MODEL #IFCS RELAYS PROCURED FROM GENERAL ELECTRIC NUCLEAR
ENERGY UNDER A SAFETY RELATED PURCHASE ORDER WERE DELIVERED WITH
LOOSE HARDWARE AND WERE UNSUITABLE FOR USE AT MILLSTONE UNIT 1.
SUBSEQUENT SURVEILLANCE BY YANKEE ATOMIC ELECTRIC COMPANY
REVEALED DEFICIENCIES IN THE GENERAL ELECTRIC COMMERCIAL
DEDICATION PROCESS. THE MANUFACTURING DEFECTS WHICH WERE
IDENTIFIED BY NORTHEAST UTILITIES WOULD HAVE IMPACTED OPERATION
OF THE RELAY. THE LICENSEE HAS DETERMINED THIS CONDITION TO BE A
SUBSTANTIAL SAFETY HAZARD.