Part 21 Report - 1997-058
ACCESSION #: 9706100458
Information & Support Services
P.O. Box 3707
Seattle, WA 98124-2207
BOEING
June 5, 1997
G-1151-SJA-97-258
Document Control Desk
United States Nuclear Regulatory Commission
Washington, D.C. 20555
Reference:
a) Boeing Letter G-1151-RSO-92-365 dated August 31, 1992; R. S. Orr to the NRC Operations Center
b) NRC Letter Docket No. 99901227 dated August 12, 1992; L. J. Norrholm to R. S. Orr; Subject: Response to 10 CFR 21 Inquiry
Dear Sir or Madam:
In accordance with the reference correspondence and 10 CFR 21, Boeing is sending the NRC the attached error notice(s) received from our former software suppliers. Because of unknown current addresses, the following former customers were not notified:
Reactor Controls, Inc.
Echo Energy Consultants, Inc.
Nuclear Applications and Systems Analysis Company (Japan)
Nuclear Power Services
Error notices have been sent to our other former customers.
Very truly yours,
Sandra J. Andrews
Nuclear Administrator
Phone: (206) 865-6248
FAX: (206) 865-4851
Mail Stop: 7A-33, or
e-mail: Sandra.Andrews@PSS.Boeing.com
Enclosure(s): GTSTRUDL Program Report Form No. 97.04
Georgia Institute
of Technology GT STRUDL [Registered Trademark]
May 29, 1997
Attention: Nuclear Administrator
Boeing Information & Support Services
P.O. Box 24346, M/S 7A-33
Seattle, Washington 98124-0346
RE: GT STRUDL
Dear Sir or Madam:
Enclosed please find copies of GTSTRUDL PROGRAM REPORT FORM No. 97.04 and a VENDOR ACKNOWLEDGMENT FORM.
Please sign and return the VENDOR ACKNOWLEDGMENT FORM to acknowledge receipt of the GTSTRUDL Program Report.
Thank you for reviewing the Program Report and for returning the Acknowledgment Form.
Best regards,
CASE Center
Lawrence F. Kahn
Director
LFK/tlk
Enclosures
Computer Aided Structural Engineering Center
Phone: (404) 894-2260 School of Civil & Environmental Engineering
Fax: (404) 894-8014 Atlanta, Georgia 30332-0355 USA
casec@ce.gatech.edu
A Unit of the University System of Georgia
GTSTRUDL Program Report Form
GPRF No.:
DATE:
FROM: Computer-Aided Structural Engineering Center
Georgia Institute of Technology
Atlanta, Georgia 30332-0355
SEVERITY LEVEL:
URGENT Problem results in incorrect answers which may not be apparent or job aborts and cannot be recovered within the session or job.
SERIOUS Problem results in incorrect answers which are obvious or problem prevents completion of a particular user's task.
MINOR Problem can be worked around or problem poses high frustration factor.
INFORMATIVE Documentation error, program usage tip, user inconveniences.
Date Problem Confirmed
Date Notification Sent
Computers
Operating System
Version
Target Release for Correction
Signature Title
R & D Division
Typed or Printed Name Date of Signature
Signature Title
Professional Services Division
Typed or Printed Name Date of Signature
Rev 2.2
GTSTRUDL Program Report Form
(Continued)
GPRF No.:
DATE:
DESCRIPTION:
If a GTSTRUDL/RC "CHECK FOR COLUMN" command is given with current units of MM and KG, CM and KG, MM and NEWT, or CM and NEWT, an abort will occur.
CHECK commands for beam options (FLEXURE, SHEAR, BOND and DEVELOPMENT) and all CHECK commands with non-metric units (INCHES, FEET, POUNDS, KIPS) are unaffected.
Workaround: Specify units as METER when CHECKing a column with metric units
Reference: Section 7.3 "The CHECK MEMBER command", Volume 4, GTSTRUDL Users Manual.
Rev 2.2
*** END OF DOCUMENT ***
Page Last Reviewed/Updated Wednesday, March 24, 2021