Part 21 Report - 1996-440
POWER REACTOR EVENT NUMBER: 30507
FACILITY: SUMMER REGION: 2 NOTIFICATION DATE: 05/20/96
UNIT: [1] [ ] [ ] STATE: SC NOTIFICATION TIME: 16:48 [ET]
RX TYPE: [1] W-3-LP EVENT DATE: 05/08/96
EVENT TIME: 00:00[EDT]
NRC NOTIFIED BY: MIKE ZACCONE LAST UPDATE DATE: 05/20/96
HQ OPS OFFICER: RUDY KARSCH
NOTIFICATIONS
EMERGENCY CLASS: NOT APPLICABLE
10 CFR SECTION:
CDEF 21.21(b)(2) DEFECTS/NONCOMPLIANCE
HODGE NRR
UNIT SCRAM CODE RX CRIT INIT PWR INIT RX MODE CURR PWR CURR RX
MODE
1 N N 0 HOT STANDBY 0 HOT STANDBY
EVENT TEXT
THE LICENSEE DISCOVERED THAT WELDS ORIGINALLY SPECIFIED AND
PERFORMED BY
WESTINGHOUSE ON COMPONENT COOLING WATER NOZZLES FOR REACTOR
COOLANT PUMP
SEAL INJECTION LINES ARE DEFECTIVE. ONE WELD HAD A CIRCUMFRENTIAL
CRACK
AND FIVE OTHERS ALSO SHOWED SIGNIFICANT CRACKING. THE LICENSEE
SUSPECTS
THAT TIG WELDING IS REQUIRED BUT NOT DONE.
Page Last Reviewed/Updated Wednesday, March 24, 2021