Part 21 Report - 1996-235
ACCESSION #: 9605200086
Information & Support Services
P.O. Box 3707
Seattle, WA 98124-2207
May 14, 1996
G-1151-SJA-96-271
Document Control Desk
United States Nuclear Regulatory Commission
Washington, D.C. 20555
Reference: a) Boeing Letter G-1 151 -RSO-92-365 dated August 31, 1992;
R. S. Orr to the NRC Operations Center
b) NRC Letter Docket No. 99901227 dated August 12, 1992; L.
J. Norrholm to R. S. Orr; Subject: Response to 10 CFR 21
Inquiry
Dear Sir or Madam:
In accordance with the reference correspondence and 10 CFR21, Boeing is
sending the NRC the attached error notice(s) received from our former
software suppliers. Because of unknown current addresses, the following
former customers were not notified:
Reactor Controls, Inc.
Echo Energy Consultants, Inc.
Nuclear Applications and Systems Analysis Company (Japan)
Nuclear Power Services
Tenera Engineering Services
Gibbs & Hill, Inc.
Error notices have been sent to our other former customers.
Very truly yours,
Sandra J. Andrews
Nuclear Administrator
G-1151 M/S 7A-33
(206) 865-6248
Attachment(s): GTSTRUDL Program Report Form No. 96.15
Georgia Tech Computer Aided Structural Engineering Center
Georgia Institute of Technology
School of Civil & Environmental Engineering
Atlanta, Georgia 30332-0355
USA
404o894o2260
404o894o8014 FAX
May 8, 1996
May 14 1996
CONTRACTS
Attention: Nuclear Administrator
Boeing Information & Support Services
P.O.Box 24346, M/S 7A-33
Seattle, Washington 98124-0346
RE: GT STRUDL
Dear Sir or Madam:
Enclosed please find copies of GTSTRUDL PROGRAM REPORT FORM No. 96.15 and
a VENDOR ACKNOWLEDGEMENT FORM. Please sign and return the VENDOR
ACKNOWLEDGEMENT FORM to acknowledge receipt of the GTSTRUDL Program
Report.
Thank you for reviewing the Program Report and for returning the
Acknowledgement Form.
Best regards,
CASE Center
Catherine Lee
Configuration Control Manager
CL/jhb
Enclosures
An Equal Education and Employment A Unit of the University System of
Opportunity Institution of Georgia
GTSTRUDL Program Report Form
GPRF No.: 96.15
DATE: May 7, 1996
FROM: Computer-Aided Structural Engineering Center
Georgia Institute of Technology
Atlanta, Georgia 30332-0355
SEVERITY LEVEL:
X URGENT Problem results in incorrect answers which may not be
apparent or job aborts and cannot be recovered within the
session or job.
_ SERIOUS Problem results in incorrect answers which are obvious or
problem prevents completion of a particular user's task.
_ MINOR Problem can be worked around or problem poses high
frustration factor.
_ INFORMATIVE Documentation error, program usage tip, user
inconveniences.
Date Problem Confirmed May 7, 1996
Date Notification Sent May 9, 1996
Computers All
Operating System All
Version All versions prior to and including 9601
Target Release for Correction 9602
Signature Title
R & D Division
Typed or Printed Name Date of Signature
Signature Title
Professional Services Division
Typed or Printed Name Date of Signature
Rev. 2.2
GTSTRUDL Program Report Form
(Continued)
GPRF No.: 96.15
DATE: May 7, 1996
DESCRIPTION:
If the positive-moment strength of a reinforced concrete beam designed
with the ACI seismic provisions at a joint exceeds one-half the negative
moment strength due to flexural strength requirements, an abort will
occur during the seismic adjustment portion of the beam design. This
condition is rare, with one reported occurance. There is no work-around.
Rev. 2.2
*** END OF DOCUMENT ***