Part 21 Report - 1996-232
ACCESSION #: 9604150413
Information & Support Services
P.O. Box 3707
Seattle, WA 98124-2207
April 8, 1996
G-1151-SJA-96-208
BOEING
Document Control Desk
United States Nuclear Regulatory Commission
Washington, D.C. 20555
Reference: a) Boeing Letter G-1151-RSO-92-365 dated August 31, 1992;
R. S. Orr to the NRC Operations Center
b) NRC Letter Docket No. 99901227 dated August 12, 1992; L.
J. Norrholm to R. S. Orr; Subject: Response to 10 CFR21
Inquiry
Dear Sir or Madam:
In accordance with the reference correspondence and 10 CFR 21, Boeing is
sending the NRC the attached error notice(s) received from our former
software suppliers. Because of unknown current addresses, the following
former customers were not notified:
Reactor Controls, Inc.
Echo Energy Consultants, Inc.
Nuclear Applications and Systems Analysis Company (Japan)
Nuclear Power Services
Tenera Engineering Services
Gibbs & Hill, Inc.
Error notices have been sent to our other former customers.
Very truly yours,
Sandra J. Andrews
Nuclear Administrator
G-1151 M/S 7A-33
(206) 865-6248
Attachment(s): GTSTRUDL Program Report Form Nos. 96.12 and 96.13
Georgia Tech Computer Aided Structural Engineering
Center
Georgia Institute of Technology
School of Civil & Environmental Engineering
Atlanta, Georgia 30332-0355
USA
404o894o2260
404o894o8014 FAX
April 2, 1996 APR 08 1996
CONTRACTS
Attention: Nuclear Administrator
Boeing Information & Support Services
P.O.Box 24346, M/S 7A-33
Seattle, Washington 98124-0346
RE: GT STRUDL
Dear Sir or Madam:
Enclosed please find copies of GTSTRUDL PROGRAM REPORT FORM Nos. 96.12
and 96.13 and a VENDOR ACKNOWLEDGEMENT FORM. Please sign and return the
VENDOR ACKNOWLEDGEMENT FORM to acknowledge receipt of the GTSTRUDL
Program Report.
Thank you for reviewing the Program Report and for returning the
Acknowledgement Form.
Best regards,
CASE Center
Catherine Lee
Configuration Control Manager
CL/jhb
Enclosures
An Equal Education and Employment A Unit of the University System
Opportunity Institution of Georgia
GTSTRUDL Program Report Form
GPRF No.: 96.12
DATE: April 1, 1996
FROM: Computer-Aided Structural Engineering Center
Georgia Institute of Technology
Atlanta, Georgia 30332-0355
SEVERITY LEVEL:
X URGENT Problem results in incorrect answers which may not be
apparent or job aborts and cannot be recovered within the
session or job.
_ SERIOUS Problem results in incorrect answers which are obvious or
problem prevents completion of a particular user's task.
_ MINOR Problem can be worked around or problem poses high
frustration factor.
_ INFORMATIVE Documentation error, program usage tip, user
inconveniences.
Date Problem Confirmed April 1, 1996
Date Notification Sent April 3, 1996
Computers ALL
Operating System ALL
Version 9001 thru 9501
Target Release for Correction 9602
Director, R&D
Signature Title
R & D Division
Kenneth Will
Typed or Printed Name Date of Signature
Signature Title
Professional Services Division
Typed or Printed Name Date of Signature
Rev. 2.2
GTSTRUDL Program Report Form
(Continued)
GPRF No.: 96.12
DATE: April 1, 1996
DESCRIPTION:
If a model contain variable member properties and the model is brought
into GTModeler, an abort may occur or the Section Property Groups in
GTModeler will contain incorrect properties. The user may verify the
properties by using the PRINT MEMBER PROPERTIES command or using the EDIT
PROPERTIES (EDI - PROP) menu in GTModeler.
Workaround:
Do not use GTMODELER when the model contains variable member properties.
Applicable Section of the Documentation:
GTMODELER - Volume 6 of the GTSTRUDL Users Manual
GEN - PROP - SECTN - VAR - Section 9.2.3
EDI - PROP - SECTN - SELECT and LIST - Section 13.3.2
Volume 1 of the GTSTRUDL Users Manual
PRINT MEMBER PROPERTIES - Section 2.1.9.2
MEMBER PROPERTIES VARIABLE - Section 2.1.14.2
Rev. 2.2
GTSTRLTDL Program Report Form
GPRF No.: 96-13
DATE: April 1, 1996
FROM: Computer-Aided Structural Engineering Center
Georgia Institute of Technology
Atlanta, Georgia 30332-0355
SEVERITY LEVEL:
x URGENT Problem results in incorrect answers which may not be
apparent or job aborts and cannot be recovered within the
session or job.
_ SERIOUS Problem results in incorrect answers which are obvious or
problem prevents completion of a particular user's task.
_ MINOR Problem can be worked around or problem poses high
frustration factor.
_ INFORMATIVE Documentation error, program usage tip, user
inconveniences.
Date Problem Confirmed April 1. 1996
Date Notification Sent April 3. 1996
Computers PC
Operating System DOS
Version 96.01
Target Release for Correction 96-02
Developer
Signature Title
R & D Division
Robert Abernathy
Typed or Printed Name Date of Signature
Signature Title
Professional Services Division
Typed or Printed Name Date of Signature
Rev. 2.2
GTSTRUDL Program Report Form
(Continued)
GPRF No.: 96.13
DATE: April 1, 1996
DESCRIPTION:
When using the new feature "LIST SECTION DISPLACEMENT option WITH
MAXIMUM", the "Disp/length" (displacement value divided by member length)
values are incorrect, except when the active units are INCHES.
To be able to use the "Disp/length" information, use the following
senario:
UNITS INCHES
LIST SECTION DISPLACEMENT CHORD WITH MAXIMUM
$ Return to the previous length units, e.g. UNITS METERS
Rev. 2.2