Part 21 Report - 1995-112
INTEGRATED RESOURCES INC. 28585 03-24-95 OTH
LICENSEE: INTEGRATED RESOURCES INC.
SITE: .INTEGRATED RESOURCES INC. . EN NUMBER:28585
DOCKET: EVENT DATE: 03-24-95
RX TYPE: EVENT TIME: 16:16
VENDORS: NOTIFY DATE: 03-24-95
EMERGENCY CLASS: N/A REGION: 4 STATE: NE TIME: 16:16
OPS OFFICER: DOUG WEAVER
10 CFR SECTION: CDEF 21.21(b)(2) DEFECTS/NONCOMPLIANCE
PART 21 -- POWER SUPPLIES USED IN APRMs ARE SUBJECT TO RANDOM
FAILURES
THE POWER SUPPLIES IN QUESTION WERE BUILT BY TDK OF JAPAN AND
SUPPLIED TO KEPCO, INC. THE KEPCO PART NUMBER IS RMX24-D-20804.
KEPCO SOLD THE PARTS TO GE. THE GE PART NUMBER IS 169C8805PO2.
INTEGRATED RESOURCES RECEIVED THE POWER SUPPLIES FROM PERRY AND
NINE MILE POINT TWO FOR REFURBISHMENT AND REPAIR. FOUR OF TWELVE
POWER SUPPLIES HAD FAILED IN USE. TWO MORE FAILED DURING TESTING
AT INTEGRATED RESOURCES. ALL FAILURES WERE CAUSED BY THE FAILURE
OF TWO OUTPUT TRANSISTORS IN THE POWER SUPPLIES. OTHER PLANTS OF
THIS VINTAGE MAY ALSO BE USING THIS POWER SUPPLY. WHEN THIS
FAILURE OCCURS THE APRM WILL FAIL DOWNSCALE.
THE CONTACT PHONE NUMBER IS 402-873-5859. INTEGRATED RESOURCES
WILL FOLLOWUP THIS PHONE REPORT WITH A WRITTEN REPORT ON 3/27/95.
* * * UPDATE 3/27/95 @ 14:19 FROM BROSEMER TAKEN BY SEBROSKY * *
*
INTEGRATED RESOURCES FAXED THE WRITTEN REPORT ON THIS PROBLEM TO
THE NRC OPERATIONS CENTER. WALTER HAASS OF NRR HAS BEEN
NOTIFIED.
* * * UPDATE AT 1135 ON 04/26/95 FROM BROSEMER TAKEN BY HOO
JOLLIFFE * * *
INTEGRATED RESOURCES, INC. FAXED A STATUS REPORT OF THIS 10CFR21
REPORT TO THE NRR OPERATIONS CENTER. HOO NOTIFIED NRR VERN
HODGE.
Page Last Reviewed/Updated Wednesday, March 24, 2021