Event Notification Report for April 26, 2022

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
04/25/2022 - 04/26/2022

EVENT NUMBERS
55770 55849
!!!!! THIS EVENT HAS BEEN RETRACTED !!!!!
!!!!! THIS EVENT HAS BEEN RETRACTED !!!!!
Fuel Cycle Facility
Event Number: 55770
Facility: Louisiana Energy Services
RX Type:
Comments: Uranium Enrichment Facility
Gas Centrifuge Facility
Region: 2
City: Eunice   State: NM
County: Lea
License #: SNM-2010
Docket: 70-3103
NRC Notified By: Barry Love
HQ OPS Officer: Kerby Scales
Notification Date: 03/07/2022
Notification Time: 13:44 [ET]
Event Date: 03/07/2022
Event Time: 10:45 [MST]
Last Update Date: 04/25/2022
Emergency Class: Non Emergency
10 CFR Section:
PART 70 APP A (a)(4) - All Safety Items Unavailable
Person (Organization):
NMSS_EVENTS_NOTIFICATION (EMAIL)
Miller, Mark (R2DO)
Event Text
EN Revision Imported Date: 4/26/2022

EN Revision Text: ITEM RELIED ON FOR SAFETY (IROFS) INOPERABLE

The following information was provided by the licensee via email:

"The plant is in a safe configuration. Three construction vehicles, a front end loader, road grader and roller, were allowed within the Controlled Access Area [CAA] boundary without IROFS50b and IROFS50c being declared Operable.

"The Administrative Control IROFS require physical barriers to be placed around the building of concern. Barriers had been placed but the IROFS had not been declared Operable by a Shift Manager.

"The construction vehicles were removed from the CAA and UUSA [Urenco USA] is conservatively reporting this event as a 1-hour Report. This event has been entered in UUSA's corrective action program as EV 149740 and a causal investigation will be performed."

The licensee will notify NRC Region 2.

* * * RETRACTION ON 04/25/2022 AT 1206 EDT FROM BARRY LOVE TO OSSY FONT * * *

The following retraction was received from Urenco USA (UUSA) via telephone and email:

"The accident sequence was originally evaluated for UUSA being in a construction phase and the applicable IROFS were applied based on these construction conditions. The accident scenario has been re-evaluated based on probabilities with current site conditions and assessed that the initiating events would be `highly unlikely' or less than 1E-06 per year, and therefore `not credible.' IROFS50b/c would not be required to meet the performance criteria of 10 CFR 70.61 for the construction vehicles on this project.

"Based on the reassessment of the accident scenarios, UUSA is retracting event notification EN 55770.
"UUSA will be notifying Region 2.

"EN 55802 is not being retracted."

Notified R2DO (Miller) and NMSS Events Notification via email.


Agreement State
Event Number: 55849
Rep Org: WA Office of Radiation Protection
Licensee: Packaging Corporation
Region: 4
City: Wallula   State: WA
County:
License #: WN-I004-1
Agreement: Y
Docket:
NRC Notified By: Jasmin Hernandez
HQ OPS Officer: Jeffrey Whited
Notification Date: 04/19/2022
Notification Time: 19:45 [ET]
Event Date: 04/15/2022
Event Time: 08:00 [PDT]
Last Update Date: 04/19/2022
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
Person (Organization):
Proulx, David (R4DO)
NMSS_Events_Notification, (EMAIL)
Event Text
AGREEMENT STATE REPORT - EQUIPMENT MISUSE

The following was received from the Washington Office of Radiation Protection via email:

"Incident took place on 4/15/22 at approximately 0800 PDT Wallula, WA. A fixed gauge [KayRay model 7062 bp; 50mCi Cs-137] was found unmounted and uncontrolled, nearby it's normally installed location. Source is intact and shutter mechanism has remained in the locked/closed position. No over exposure or spread of contamination. The fixed gauge is currently reinstalled at it's normal location, pending further investigation and report.

Incident Number: WA-22-010