U.S. Nuclear Regulatory Commission Operations Center Event Reports For 9/27/2018 - 9/28/2018 ** EVENT NUMBERS ** |
Agreement State | Event Number: 53613 | Rep Org: OHIO BUREAU OF RADIATION PROTECTION Licensee: THE CLEVELAND CLINIC FOUNDATION Region: 3 City: CLEVELAND State: OH County: License #: 02110180013 Agreement: Y Docket: NRC Notified By: MICHAEL RUBADUE HQ OPS Officer: ANDREW WAUGH | Notification Date: 09/19/2018 Notification Time: 14:40 [ET] Event Date: 09/19/2018 Event Time: 00:00 [EDT] Last Update Date: 09/19/2018 | Emergency Class: NON EMERGENCY 10 CFR Section: AGREEMENT STATE | Person (Organization): ROBERT ORLIKOWSKI (R3DO) NMSS_EVENTS_NOTIFICATION (EMAIL) | Event Text AGREEMENT STATE REPORT - PACKAGE ARRIVED WITH SURFACE CONTAMINATION
The following information was obtained from the Ohio Department of Health via email:
"At approximately 0730 EDT on 9/19/18, a package containing Tc-99m was received by the Cleveland Clinic Foundation from Cardinal Health in Oakwood, OH that exceeded the DOT surface contamination limits. The contact dose rates were incompliance. An initial wipe for removable contamination showed 1258 cpm over 300 cm2 of the package surface. Wipes of the handle (10759 cpm), the zipper (11290 cpm) and the top address label cover (24342 cpm) identified additional removable contamination on the package. Conversion to dpm with appropriate area correction resulted in 2946 dpm/cm2.
"No other contamination was found in the lab or package receipt area.
"A follow-up inspection at Cardinal Health in Oakwood will be conducted to determine the cause of the event."
Ohio NMED Report No.: OH180008 |
Agreement State | Event Number: 53614 | Rep Org: CALIFORNIA RADIATION CONTROL PRGM Licensee: EARTH SYSTEMS PACIFIC Region: 4 City: VENTURA State: CA County: License #: 8166-56 Agreement: Y Docket: NRC Notified By: DONALD OESTERLE HQ OPS Officer: PHIL NATIVIDAD | Notification Date: 09/20/2018 Notification Time: 15:24 [ET] Event Date: 09/19/2018 Event Time: 00:00 [PDT] Last Update Date: 09/20/2018 | Emergency Class: NON EMERGENCY 10 CFR Section: AGREEMENT STATE | Person (Organization): NEIL O'KEEFE (R4DO) NMSS_EVENTS_NOTIFICATION (EMAIL) | Event Text AGREEMENT STATE REPORT - DAMAGED GAUGE AT CONSTRUCTION SITE
The following information was received from the State of California via email:
"On September 19, 2018, the [Radiation Safety Officer] RSO notified the [California Radiological Health Branch] that a CPN soils gauge, model MC-1DR # MD00605736 containing 10 mCi of Cs-137 and 50 mCi of Am-241/Be had been run over by construction equipment at a temporary job site in Camarillo, CA. The gauge operator had placed the gauge near his test area, but was 15 feet away when the accident occurred. After the accident, he immediately stopped all work in the area and cordoned off an area 30 feet around the damaged gauge before calling his RSO.
"A radiation survey meter was available from a local radiography company who met the RSO and the gauge operator at accident site. The shaft housing the rod above the cesium source was snapped off from the gauge. The source was in the 'safe mode' during the accident and remained in the shielded area of the gauge. The gauge was able to be loaded into the shipping container for return to the permanent storage location. Radiation surveys were performed with a Bicron GM detector and no contamination was found in the area. The root cause is operator error by the gauge operator. The gauge will be disposed thru the manufacturer (CPN)."
California Report No.: 5010-091918 |
Power Reactor | Event Number: 53628 | Facility: VOGTLE Region: 2 State: GA Unit: [3] [4] [] RX Type: [3] W-AP1000,[4] W-AP1000 NRC Notified By: DANIEL MICKINAC HQ OPS Officer: OSSY FONT | Notification Date: 09/27/2018 Notification Time: 14:42 [ET] Event Date: 09/27/2018 Event Time: 00:00 [EDT] Last Update Date: 09/27/2018 | Emergency Class: NON EMERGENCY 10 CFR Section: 26.719 - FITNESS FOR DUTY | Person (Organization): NICOLE COOVERT (R2DO) FFD GROUP (EMAIL) | Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode | 3 | N | N | 0 | Under Construction | 0 | Under Construction | 4 | N | N | 0 | Under Construction | 0 | Under Construction | Event Text FITNESS FOR DUTY - CONTRACTOR SUPERVISOR TESTS POSITIVE
"At 1000 EDT on September 27, 2018, Southern Nuclear Operating Company (SNC) determined a contractor supervisor confirmed positive for drugs during a random Fitness-for-Duty (FFD) test. The employee's unescorted access to the plant has been suspended.
"The NRC Resident Inspector has been notified." | |