Event Notification Report for December 14, 2001

                         
                    U.S. Nuclear Regulatory Commission
                              Operations Center

                              Event Reports For
                           12/13/2001 - 12/14/2001

                              ** EVENT NUMBERS **

38560  38561  
.
+------------------------------------------------------------------------------+
|General Information or Other                     |Event Number:   38560       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG:  CARBOLINE COMPANY                    |NOTIFICATION DATE: 12/13/2001|
|LICENSEE:  CARBOLINE COMPANY                    |NOTIFICATION TIME: 16:06[EST]|
|    CITY:  BRENTWOOD                REGION:  3  |EVENT DATE:        12/13/2001|
|  COUNTY:                            STATE:  MO |EVENT TIME:        12:00[CST]|
|LICENSE#:                        AGREEMENT:  N  |LAST UPDATE DATE:  12/13/2001|
|  DOCKET:                                       |+----------------------------+
|                                                |PERSON          ORGANIZATION |
|                                                |CLIFFORD ANDERSON    R1      |
|                                                |ANNE MARIE STONE     R3      |
+------------------------------------------------+                             |
| NRC NOTIFIED BY:  RICHARD MIDDEKE              |                             |
|  HQ OPS OFFICER:  JOHN MacKINNON               |                             |
+------------------------------------------------+                             |
|EMERGENCY CLASS:                                |                             |
|10 CFR SECTION:                                 |                             |
|CCCC 21.21               UNSPECIFIED PARAGRAPH  |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| CARBOZINC 11 SG HAS BEEN DETERMINED TO HAVE A REPORTABLE DEFECT.            
|
|                                                                              |
| Carboline has been notified of stability problems with some Carbozinc 11 SG  |
| product over the last year.  The material is exhibiting premature gellation  |
| or thickening prior to the end of the published shelf life expiration date.  |
| Carbozinc 11 SG that is gelled or exhibiting significant thickening will not |
| atomize or spray properly, resulting in poor adhesion to the substrate.      |
| When this occurs the coating cracks during the spray process and the coating |
| process and the coating flakes off the substrate.                            |
|                                                                              |
| On December 14, 2001, Carboline will send by register mail to all purchasers |
| of Carbozinc 11 SG reporting Part 21 Reporting of Defect.                    |
|                                                                              |
| See event number 38408, reported 10/19/2001 for background information.      |
+------------------------------------------------------------------------------+
.
+------------------------------------------------------------------------------+
|General Information or Other                     |Event Number:   38561       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG:  TEXAS DEPARTMENT OF HEALTH           |NOTIFICATION DATE: 12/13/2001|
|LICENSEE:  BAPTIST HEALTH SYSTEM                |NOTIFICATION TIME: 17:00[EST]|
|    CITY:  SAN ANTONIO              REGION:  4  |EVENT DATE:        12/09/2001|
|  COUNTY:                            STATE:  TX |EVENT TIME:             [CST]|
|LICENSE#:  L-00455               AGREEMENT:  Y  |LAST UPDATE DATE:  12/13/2001|
|  DOCKET:                                       |+----------------------------+
|                                                |PERSON          ORGANIZATION |
|                                                |BILL JONES           R4      |
|                                                |C.W. (BILL) REAMER   NMSS    |
+------------------------------------------------+                             |
| NRC NOTIFIED BY:  JAMES H. OGDEN               |                             |
|  HQ OPS OFFICER:  JOHN MacKINNON               |                             |
+------------------------------------------------+                             |
|EMERGENCY CLASS:          NON EMERGENCY         |                             |
|10 CFR SECTION:                                 |                             |
|NAGR                     AGREEMENT STATE        |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| LOST RADIOACTIVE SEALED SOURCE                                               |
|                                                                              |
| Hospital had a package of 94 I-125 seeds at 310 microcuries each delivered   |
| on December 9, 2001.  Package was delivered to the nuclear medicine          |
| department and left on top of boxes that the person delivering thought would |
| be seen by nuclear medicine personnel. The package was not accepted by an    |
| individual in nuclear medicine.  At the time of the scheduled treatment,     |
| December 11, 2001, nuclear medicine called to see where the seeds were and   |
| were told that they had arrived on the 9th and had been delivered to nuclear |
| medicine.  The seeds were packaged and the seeds cannot be found.            |
|                                                                              |
| Texas Incident No. I-7839.                                                   |
+------------------------------------------------------------------------------+
.

Page Last Reviewed/Updated Wednesday, March 24, 2021