** EVENT NUMBERS **
36472 36473 36474
+------------------------------------------------------------------------------+
|Other Nuclear Material |Event Number: 36472 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG: BEST FOODS |NOTIFICATION DATE: 11/29/1999|
|LICENSEE: BEST FOODS |NOTIFICATION TIME: 15:27[EST]|
| CITY: BAYONNE REGION: 1 |EVENT DATE: 11/29/1999|
| COUNTY: STATE: NJ |EVENT TIME: [EST]|
|LICENSE#: 1586-70GL AGREEMENT: N |LAST UPDATE DATE: 11/29/1999|
| DOCKET: |+----------------------------+
| |PERSON ORGANIZATION |
| |STEVEN DENNIS R1 |
| |JOSIE PICCONE NMSS |
+------------------------------------------------+ |
| NRC NOTIFIED BY: JAMES LITTEN | |
| HQ OPS OFFICER: BOB STRANSKY | |
+------------------------------------------------+ |
|EMERGENCY CLASS: N/A | |
|10 CFR SECTION: | |
|BAB2 20.2201(a)(1)(ii) LOST/STOLEN LNM>10X | |
| | |
| | |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| STOLEN PROCESS GAUGE |
| |
| A representative of Best Foods called the NRC Operations Center to report |
| the apparent theft of a process gauge. The device, a Filtec model CI-2GV |
| case inspector (serial #75009), could not be located for its triennial |
| leakage test. The gauge contains a 100 millicurie Am-241 source (source |
| #3428). The gauge was last swipe tested in 1996. The gauge was a spare, and |
| has been kept in a storage area with other spare parts. The caller was |
| unsure whether a police report would be filed. |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|Power Reactor |Event Number: 36473 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: POINT BEACH REGION: 3 |NOTIFICATION DATE: 11/29/1999|
| UNIT: [1] [2] [] STATE: WI |NOTIFICATION TIME: 16:43[EST]|
| RXTYPE: [1] W-2-LP,[2] W-2-LP |EVENT DATE: 11/29/1999|
+------------------------------------------------+EVENT TIME: [CST]|
| NRC NOTIFIED BY: GOSPAREK |LAST UPDATE DATE: 11/29/1999|
| HQ OPS OFFICER: BOB STRANSKY +-----------------------------+
+------------------------------------------------+PERSON ORGANIZATION |
|EMERGENCY CLASS: N/A |GEOFFREY WRIGHT R3 |
|10 CFR SECTION: | |
|DDDD 73.71 UNSPECIFIED PARAGRAPH | |
| | |
| | |
| | |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1 N N 0 Refueling |0 Refueling |
|2 N Y 100 Power Operation |100 Power Operation |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| SECURITY EVENT |
| |
| Unescorted access granted inappropriately. Contact the NRC Operations Center |
| for additional details. The NRC resident inspector has been informed by the |
| licensee. |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|Power Reactor |Event Number: 36474 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: WOLF CREEK REGION: 4 |NOTIFICATION DATE: 11/30/1999|
| UNIT: [1] [] [] STATE: KS |NOTIFICATION TIME: 06:12[EST]|
| RXTYPE: [1] W-4-LP |EVENT DATE: 11/30/1999|
+------------------------------------------------+EVENT TIME: 04:59[CST]|
| NRC NOTIFIED BY: DALE BERRY |LAST UPDATE DATE: 11/30/1999|
| HQ OPS OFFICER: DICK JOLLIFFE +-----------------------------+
+------------------------------------------------+PERSON ORGANIZATION |
|EMERGENCY CLASS: N/A |DALE POWERS R4 |
|10 CFR SECTION: | |
|ASHU 50.72(b)(1)(i)(A) PLANT S/D REQD BY TS | |
| | |
| | |
| | |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1 N Y 100 Power Operation |100 Power Operation |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| -TS REQD PLANT S/D DUE TO FAILED ESFAS AFW ACTUATION LOGIC RELAY 48 VDC |
| POWER SUPPLY- |
| |
| THE LICENSEE DISCOVERED A FAILED 48 VDC POWER SUPPLY FOR THE BALANCE OF |
| PLANT ENGINEERED SAFETY FEATURE ACTUATION SYSTEM (ESFAS) AUTOMATIC ACTUATION |
| LOGIC RELAYS FOR THE TRAIN 'A' AUXILIARY FEEDWATER (AFW) SYSTEM. TECH SPEC |
| 3.3.2, FUNCTION 6.C, ACTION 2, REQUIRES THE LICENSEE TO RESTORE THE POWER |
| SUPPLY TO OPERABLE STATUS OR TO PLACE THE PLANT IN HOT STANDBY MODE IN 6 |
| HOURS AND HOT SHUTDOWN IN THE FOLLOWING 6 HOURS. |
| |
| THE LICENSEE INFORMED THE NRC RESIDENT INSPECTOR. |
+------------------------------------------------------------------------------+