Event Notification Report for September 16, 1999
U.S. Nuclear Regulatory Commission
Operations Center
Event Reports For
09/15/1999 - 09/16/1999
** EVENT NUMBERS **
36149 36156 36163 36164 36165 36166 36167 36168 36169 36170 36171
+------------------------------------------------------------------------------+
|Power Reactor |Event Number: 36149 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: NORTH ANNA REGION: 2 |NOTIFICATION DATE: 09/12/1999|
| UNIT: [1] [2] [] STATE: VA |NOTIFICATION TIME: 09:30[EDT]|
| RXTYPE: [1] W-3-LP,[2] W-3-LP |EVENT DATE: 09/12/1999|
+------------------------------------------------+EVENT TIME: 09:04[EDT]|
| NRC NOTIFIED BY: VICKY HARTE |LAST UPDATE DATE: 09/15/1999|
| HQ OPS OFFICER: FANGIE JONES +-----------------------------+
+------------------------------------------------+PERSON ORGANIZATION |
|EMERGENCY CLASS: N/A |ROBERT HAAG R2 |
|10 CFR SECTION: | |
|AENS 50.72(b)(1)(v) ENS INOPERABLE | |
| | |
| | |
| | |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1 N Y 60 Power Operation |60 Power Operation |
|2 N N 0 Hot Standby |0 Hot Standby |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| LOST SAFETY PARAMETER DISPLAY SYSTEM AND THE TECHNICAL SUPPORT CENTER |
| COMPUTER |
| |
| Power was lost to the Safety Parameter Display System (SPDS) and the |
| Technical Support Center (TSC) computer system at 0904 EDT on 9/12/99. The |
| bus supplying power to the battery charger for the SPDS and TSC computer was |
| lost when the supply breaker opened on a ground detection, on the |
| underground cable supply. The normal alternate power supply to the battery |
| charger was previously lost, some time ago, due to another ground on its |
| underground cable supply. The licensee made the decision to preserve the |
| battery and deenergized the battery bus. Also, with the TSC computer system |
| out-of-service, the control room will serve as the alternate TSC facility. |
| |
| This event is a major loss of emergency assessment capability and is |
| reportable. Troubleshooting and repairs to the electrical distribution |
| system are in progress. Also, the licensee is investigating an alternate |
| methods to power the battery charger. |
| |
| The licensee notified the NRC Resident Inspector. |
| |
| |
| ***Update on 09/15/99 at 1255ET by Kemp taken by MacKinnon*** |
| |
| Power was restored to the TSC and the SPDS was restored to service at 1132ET |
| today (09/15/99). R2DO (Chris Christensen) notified. |
| |
| The NRC Resident Inspector will be informed by the licensee of this update. |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|Power Reactor |Event Number: 36156 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: SAINT LUCIE REGION: 2 |NOTIFICATION DATE: 09/13/1999|
| UNIT: [1] [2] [] STATE: FL |NOTIFICATION TIME: 17:30[EDT]|
| RXTYPE: [1] CE,[2] CE |EVENT DATE: 09/13/1999|
+------------------------------------------------+EVENT TIME: 17:13[EDT]|
| NRC NOTIFIED BY: STEVE MERRILL |LAST UPDATE DATE: 09/15/1999|
| HQ OPS OFFICER: JOHN MacKINNON +-----------------------------+
+------------------------------------------------+PERSON ORGANIZATION |
|EMERGENCY CLASS: UNU |ROBERT HAAG R2 |
|10 CFR SECTION: |JOSEPH GIITTER IRO |
|AAEC 50.72 (a) (1) (I) EMERGENCY DECLARED |DAN SULLIVAN FEMA |
| |FRANK CONGEL IRO |
| |ELINOR ADENSAM NRR |
| | |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1 N N 0 Hot Shutdown |0 Hot Shutdown |
|2 N Y 100 Power Operation |100 Power Operation |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| UNUSUAL EVENT DECLARED DUE TO ENTERING EAL 5B ITEM 1 (CONFIRMED HURRICANE |
| WARNING IN EFFECT) |
| |
| The licensee entered an Unusual Event per Emergency Action Level 5B item 1. |
| All emergency diesel generators are fully operable and the electrical grid |
| is stable. All emergency core cooling systems are fully operable. The state |
| was notified of the Unusual Event classification. Local counties will be |
| notified of the Unusual Event classification by the state of Florida. |
| |
| The NRC Resident Inspector will be notified of this event by the licensee. |
| |
| * * * UPDATE 0930 9/14/1999 BY STRANSKY * * * |
| |
| The NRC entered the Monitoring Phase of Normal Mode at 0930 on 9/14/1999 in |
| preparation of potential landfall by Hurricane Floyd. |
| |
| * * * COMMISSIONER'S ASSISTANTS BRIEF, 1000 EDT ON 9/14/99 * * * |
| |
| Luis Reyes the R2RA conducted the brief, IRO (Frank Congel), NRR (Tad |
| Marsh), NMSS (Josie Piccone), PA (William Beecher), SP (Fred Combs), R2 IRC |
| (Pierce Skinner), CA (Betsy Keeling), EDO Staff (Leonard Wert), IP (Karen |
| Henderson), SECY (Andrew Bates), Chairman Dicus Off (Thomas Hiltz), Comm. |
| McGaffigan Off (James Beall), Comm. Diaz Off (Anthony Hsia), Comm. |
| Merrifield Off (Lynne Stauss) |
| |
| *** COMMISSIONER'S ASSISTANCE BRIEF, 2000 EDT ON 9/14/99 *** |
| |
| Luis Reyes the R2RA conducted the brief, EDO (Jim Dyer), IRO ( Joe Giitter), |
| NRR EO (Bill Beckner), NMSS (Josie Piccone), CA (Betsy Keeling), Chairman |
| Dicus Off (Tom Hiltz), Comm McGaffigan (James Beall), Comm Merrifield |
| (Lynne Stauss & John Thoma), NRC R2 (Bruce Mallett & Anne Boland) . |
| |
| * * * UPDATE AT 0059 EDT ON 9/15/99 BY JACK BREEN TO FANGIE JONES * * * |
| |
| Unusual Event was terminated at 0040 EDT when the hurricane warning was |
| lifted by the National Hurricane Center. The licensee notified the NRC |
| Resident Inspector and intends notifying the state and surrounding counties |
| of exiting the Unusual Event. R2DO (Chris Christensen), NRR EO (William |
| Beckner), and FEMA (Wayne Storer) notified. |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|Power Reactor |Event Number: 36163 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: BRUNSWICK REGION: 2 |NOTIFICATION DATE: 09/14/1999|
| UNIT: [1] [2] [] STATE: NC |NOTIFICATION TIME: 23:30[EDT]|
| RXTYPE: [1] GE-4,[2] GE-4 |EVENT DATE: 09/14/1999|
+------------------------------------------------+EVENT TIME: 23:10[EDT]|
| NRC NOTIFIED BY: THOMAS WOODALL |LAST UPDATE DATE: 09/16/1999|
| HQ OPS OFFICER: JOHN MacKINNON +-----------------------------+
+------------------------------------------------+PERSON ORGANIZATION |
|EMERGENCY CLASS: UNU |CHRIS CHRISTENSEN R2 |
|10 CFR SECTION: |WILLIAM BECKNER NRR |
|AAEC 50.72 (a) (1) (I) EMERGENCY DECLARED |FRANK CONGEL IRO |
| |WAYNE STORER FEMA |
| | |
| | |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1 N Y 100 Power Operation |100 Power Operation |
|2 N Y 100 Power Operation |100 Power Operation |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| UNUSUAL EVENT DECLARED DUE TO ENTERING EAL 2.1 SECTION 14.1.2 (NATURAL EVENT |
| - HURRICANE WARNING). |
| |
| The licensee entered an Unusual Event per Emergency Action Level 2.1 Section |
| 14.1.2. All emergency diesel generators and their emergency core cooling |
| systems are fully operable. The electrical grid is stable. The licensee said |
| that they would have to enter Abnormal Operating Procedure 13 two hours |
| before wind speed increased to 75 mph. The licensee projects that they have |
| 27 hours until hurricane force winds reach their site. |
| The licensee has notified the state of North Carolina and surrounding |
| counties of entering an unusual event classification. |
| |
| The NRC Resident Inspector will be informed of this event by the licensee. |
| |
| * * * UPDATE 0845EDT ON 9/15/99 FROM DON DEWEY TO S. SANDIN * * * |
| |
| The licensee decided at 0830EDT to reduce power on both units to 40% by |
| 1000EDT and hold. A decision as to whether a shutdown should continue will |
| be made at that time. Unit 1 and 2 are currently at 76% and 82% power, |
| respectively. The licensee will inform the NRC Resident Inspector. |
| Notified R2 IRC(Skinner). |
| |
| |
| ***UPDATE AT 1248ET ON 09/15/99 BY DON DEWEY TAKEN BY MACKINNON*** |
| |
| Brunswick Unit 2 was manually scrammed from 31% reactor power at 1118 hours. |
| All systems operated as expected. |
| |
| Brunswick Unit 1 was manually scrammed from 35% reactor power at 1206 hours. |
| All systems operated as expected. |
| |
| All Emergency Core Cooling Systems and the Emergency Diesel Generators are |
| fully operable if needed. The offsite electrical grid at this time is |
| stable. On site wind speed is 32 mph. |
| |
| R2DO (Chris Christensen & Pierce Skinner), NRR (Bill Beckner & Bob Dennig) |
| and IRO (Joe Giitter) notified. |
| |
| The NRC Resident Inspector was notified of this event update by the |
| licensee. |
| |
| ***UPDATE AT 2016ET ON 09/15/99 BY ROBBINS TAKEN BY MACKINNON*** |
| |
| Brunswick Unit 2 entered a cold shutdown condition at 1935 hours and |
| Brunswick Unit 2 entered a cold shutdown condition at 1955 hours. Onsite |
| wind speed is 34 mph. R2DO (Chris Christensen) & NRC Region 2 IRC (Anne |
| Boland) notified. |
| |
| The NRC Resident Inspector was notified of this update by the licensee. |
| |
| * * * UPDATE 0510EDT ON 9/16/99 VIA FAX TO S. SANDIN * * * |
| |
| Message #6 was received via fax: |
| |
| "32 of the 35 Emergency Warning Sirens are now indicating an inoperable |
| status due to a loss of power. Some siding panels from the turbine building |
| have been lost. The turbine building radiological conditions are monitored. |
| Both Units are in cold shutdown." [see event #36169] Meteorological |
| conditions as of 0458EDT were wind direction from 240-280 degrees, speed |
| 75-95 mph, stability class D with rain. Notified R2 IRC(Reyes). |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|Power Reactor |Event Number: 36164 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: BRUNSWICK REGION: 2 |NOTIFICATION DATE: 09/15/1999|
| UNIT: [1] [2] [] STATE: NC |NOTIFICATION TIME: 11:31[EDT]|
| RXTYPE: [1] GE-4,[2] GE-4 |EVENT DATE: 09/15/1999|
+------------------------------------------------+EVENT TIME: 09:35[EDT]|
| NRC NOTIFIED BY: DAVID JENKINS |LAST UPDATE DATE: 09/15/1999|
| HQ OPS OFFICER: WILLIAM POERTNER +-----------------------------+
+------------------------------------------------+PERSON ORGANIZATION |
|EMERGENCY CLASS: N/A |CHRIS CHRISTENSEN R2 |
|10 CFR SECTION: | |
|APRE 50.72(b)(2)(vi) OFFSITE NOTIFICATION | |
| | |
| | |
| | |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1 N Y 60 Power Operation |60 Power Operation |
|2 N Y 60 Power Operation |60 Power Operation |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| OFFSITE NOTIFICATION DUE TO OPENING STORM DRAIN BYPASS VALVES |
| |
| On September 15, 1999, at 0935 EDT, the bypass valves from the site's storm |
| drain basin directly to the circulating water discharge canal were opened to |
| prevent site flooding (which could cause significant damage to plant |
| equipment and/or possibly endanger personnel safety) due to the impending |
| arrival of hurricane Floyd. Past experience has shown that the installed |
| pump capacity will not keep up with the rain expected during a hurricane. |
| The valves were opened prior to hurricane force winds reaching the site to |
| avoid exposing personnel to the hurricane. Opening these valves is a |
| reportable event (to the state of North Carolina) in accordance with the |
| site National Pollutant Discharge Elimination System permit. |
| |
| The NRC resident has been notified. |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|Hospital |Event Number: 36165 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG: WILLIAM BEAUMONT HOSPITAL |NOTIFICATION DATE: 09/15/1999|
|LICENSEE: WILLIAM BEAUMONT HOSPITAL |NOTIFICATION TIME: 14:59[EDT]|
| CITY: ROYAL OAK REGION: 3 |EVENT DATE: 09/15/1999|
| COUNTY: STATE: MI |EVENT TIME: 11:00[EDT]|
|LICENSE#: 21-01333-01 AGREEMENT: N |LAST UPDATE DATE: 09/15/1999|
| DOCKET: |+----------------------------+
| |PERSON ORGANIZATION |
| |GARY SHEAR R3 |
| |JOSIE PICCONE NMSS |
+------------------------------------------------+ |
| NRC NOTIFIED BY: CHERYL SCHULTZ | |
| HQ OPS OFFICER: JOHN MacKINNON | |
+------------------------------------------------+ |
|EMERGENCY CLASS: N/A | |
|10 CFR SECTION: | |
|LADM 35.33(a) MED MISADMINISTRATION | |
| | |
| | |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| PATIENT RECEIVED A PLACEBO INSTEAD OF 20 GRAY OF P-32. |
| |
| A patient signed a consent form to participate in a coronary brachytherapy |
| trial to evaluate the Guidant Coronary Afterloader. The patient was |
| randomized to receive 20 Gray to the proximal left anterior descending |
| coronary artery with P-32, but the Radiation Oncology physicist programmed |
| the afterloader to use the placebo source wire instead. Therefore, the |
| patient did not receive the prescribed dose of 20 Gray. The root cause for |
| the error was that the Radiation Oncologist did not adequately confirm the |
| written directive prior to treatment. There was no documentation on the |
| randomization order to guide the physicist in selecting the proper |
| treatment, so he relied on his memory, which failed. |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|Power Reactor |Event Number: 36166 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: INDIAN POINT REGION: 1 |NOTIFICATION DATE: 09/15/1999|
| UNIT: [2] [] [] STATE: NY |NOTIFICATION TIME: 16:06[EDT]|
| RXTYPE: [2] W-4-LP,[3] W-4-LP |EVENT DATE: 09/15/1999|
+------------------------------------------------+EVENT TIME: 15:36[EDT]|
| NRC NOTIFIED BY: PHIL SANTINI |LAST UPDATE DATE: 09/15/1999|
| HQ OPS OFFICER: BOB STRANSKY +-----------------------------+
+------------------------------------------------+PERSON ORGANIZATION |
|EMERGENCY CLASS: N/A |NIEL DELLA GRECA R1 |
|10 CFR SECTION: | |
|AEXT 50.72(b)(1)(iii) EXTERNAL THREAT | |
| | |
| | |
| | |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|2 N N 0 Hot Shutdown |0 Hot Shutdown |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| HURRICANE WINDS PREDICTED TO COME WITHIN 500 NM OF SITE |
| |
| At 1536, the licensee was notified that the National Weather Service had |
| issued hurricane warnings for North Carolina and Virginia, with hurricane |
| force winds extending 140 miles outward from the center of Hurricane Floyd. |
| The licensee considers that the arrival of hurricane force winds within 500 |
| nautical miles (NM) of Indian Point, concurrent with hurricane warnings is |
| imminent. This notification is being made in accordance with Technical |
| Specification 3.14.a and Abnormal Operating Instruction 28.07. The NRC |
| resident inspector will be informed of this notification by the licensee. |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|Power Reactor |Event Number: 36167 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: SURRY REGION: 2 |NOTIFICATION DATE: 09/15/1999|
| UNIT: [1] [2] [] STATE: VA |NOTIFICATION TIME: 22:17[EDT]|
| RXTYPE: [1] W-3-LP,[2] W-3-LP |EVENT DATE: 09/15/1999|
+------------------------------------------------+EVENT TIME: 22:00[EDT]|
| NRC NOTIFIED BY: DON KARNS |LAST UPDATE DATE: 09/16/1999|
| HQ OPS OFFICER: BOB STRANSKY +-----------------------------+
+------------------------------------------------+PERSON ORGANIZATION |
|EMERGENCY CLASS: UNU |CHRIS CHRISTENSEN R2 |
|10 CFR SECTION: |ANN BOLAND R2 |
|AAEC 50.72 (a) (1) (I) EMERGENCY DECLARED |WILLIAM BECKNER NRR |
| |FRANK CONGEL IRO |
| |BELCHER FEMA |
| | |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1 N Y 100 Power Operation |83 Power Operation |
|2 N Y 100 Power Operation |47 Power Operation |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| UNUSUAL EVENT DECLARED DUE TO APPROACHING HURRICANE |
| |
| An Unusual Event was declared at 2200 EDT due to the expected onset of |
| hurricane force winds within the following 12 hours. The licensee currently |
| expects that hurricane force winds will occur onsite at 1000 EDT. Both units |
| are currently being shut down in anticipation of the hurricane arrival. |
| Shutdown of Unit 2 commenced at 1906 EDT, and Unit 1 began shutting down at |
| 2040 EDT. The NRC resident inspector has been informed of this |
| notification. |
| |
| * * * UPDATE 0210EDT ON 9/16/99 FROM DALE JONES TO S. SANDIN * * * |
| |
| The licensee is holding power at 46% on Unit 1 and 35% on Unit 2 pending an |
| assessment of the path of Hurricane Floyd. Current projections for maximum |
| sustained wind on site indicate less than 60 mph due to the more easterly |
| course change. Notified R2DO(Christensen) and R2(Boland). |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|Power Reactor |Event Number: 36168 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: BROWNS FERRY REGION: 2 |NOTIFICATION DATE: 09/15/1999|
| UNIT: [] [2] [] STATE: AL |NOTIFICATION TIME: 22:55[EDT]|
| RXTYPE: [1] GE-4,[2] GE-4,[3] GE-4 |EVENT DATE: 09/15/1999|
+------------------------------------------------+EVENT TIME: 18:25[CDT]|
| NRC NOTIFIED BY: JOSEPH BENNETT |LAST UPDATE DATE: 09/15/1999|
| HQ OPS OFFICER: JOHN MacKINNON +-----------------------------+
+------------------------------------------------+PERSON ORGANIZATION |
|EMERGENCY CLASS: N/A |CHRIS CHRISTENSEN R2 |
|10 CFR SECTION: | |
|APRE 50.72(b)(2)(vi) OFFSITE NOTIFICATION | |
|AESF 50.72(b)(2)(ii) ESF ACTUATION | |
| | |
| | |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE |
+-----+----------+-------+--------+-----------------+--------+-----------------+
| | |
|2 M/R Y 52 Power Operation |0 Hot Shutdown |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| REACTOR MANUALLY SCRAMMED FROM 52% REACTOR POWER DUE TO AN UNCONTROLLABLE |
| LOSS OF ELECTROHYDRAULIC CONTROL (EHC) FLUID. |
| |
| |
| At approximately 1750 on 09/15/99, failure of an EHC system pressure sensing |
| line resulted in an uncontrollable loss of EHC fluid. Attempts to maintain |
| EHC reservoir level failed, and a 1825 hours, the reactor was manually |
| scrammed from 52% reactor power in preparation for removing the EHC system |
| from service. Reactor power was initially at 100% and it was reduced to 52% |
| before the reactor was manually scrammed. The scram resulted in a low |
| reactor vessel water level, causing an automatic isolation of Primary |
| Containment Isolation System (PCIS) groups 2 (Drywell isolations), 3 |
| (Reactor Water Cleanup trip/isolation), &8 (transversing incore probe system |
| isolation). EOI-1 was entered due to low reactor vessel water level |
| {decreased to negative 28.5", Top of Active Fuel (TAF) is negative 162"} and |
| to control reactor pressure with the loss of the EHC system. No Main Steam |
| Safety Relief Valves (MSRVs) were actuated during this event. All control |
| rods fully inserted into the core. |
| |
| The licensee started that restart is projected for 1600 hours on 09/16/99. |
| |
| |
| NRC Region 2 Section Chief (Paul Fredrickson) was notified of this event by |
| the licensee. |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|Power Reactor |Event Number: 36169 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: BRUNSWICK REGION: 2 |NOTIFICATION DATE: 09/16/1999|
| UNIT: [1] [2] [] STATE: NC |NOTIFICATION TIME: 01:21[EDT]|
| RXTYPE: [1] GE-4,[2] GE-4 |EVENT DATE: 09/16/1999|
+------------------------------------------------+EVENT TIME: 00:50[EDT]|
| NRC NOTIFIED BY: DAVE JESTER |LAST UPDATE DATE: 09/16/1999|
| HQ OPS OFFICER: STEVE SANDIN +-----------------------------+
+------------------------------------------------+PERSON ORGANIZATION |
|EMERGENCY CLASS: N/A |CHRIS CHRISTENSEN R2 |
|10 CFR SECTION: |ANNE BOLAND R2 |
|AARC 50.72(b)(1)(v) OTHER ASMT/COMM INOP | |
|APRE 50.72(b)(2)(vi) OFFSITE NOTIFICATION | |
| | |
| | |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1 N N 0 Cold Shutdown |0 Cold Shutdown |
|2 N N 0 Cold Shutdown |0 Cold Shutdown |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| PARTIAL LOSS OF EMERGENCY SIREN CAPABILITY DURING HURRICANE FLOYD |
| |
| "[Operations was] informed by Brunswick Plant Emergency Preparedness |
| personnel that 13 emergency warning offsite sirens have failed as a result |
| of Hurricane Floyd. |
| |
| "[The initial safety significance evaluation characterized the significance |
| of the loss of the sirens as] minimal. Backup alert measures are in place. |
| Local agencies have been notified. |
| |
| "[Corrective action(s) include a] complete investigation into the cause of |
| the failure and complete required repairs." |
| |
| The thirteen [13] sirens are located primarily on the beach and on Bald Head |
| Island and Boiling Spring Lake in Brunswick county. There are an |
| additional seventeen [17] operable sirens currently available in Brunswick |
| county and five [5] more in New Hanover county. The loss of the 13 sirens |
| was related to loss of power as detected by an external operability check |
| performed by a computer. The licensee will not initiate repairs until the |
| storm passes. |
| |
| The licensee informed state/local agencies and the NRC Resident Inspector. |
| |
| * * * UPDATE 0510EDT ON 9/16/99 VIA FAX TO S. SANDIN * * * |
| |
| Thirty-two [32] of the thirty-five [35] sirens are out-of-service. See |
| event #36163 for additional information. Notified R2 IRC (Reyes). |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|Power Reactor |Event Number: 36170 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: HARRIS REGION: 2 |NOTIFICATION DATE: 09/16/1999|
| UNIT: [1] [] [] STATE: NC |NOTIFICATION TIME: 02:32[EDT]|
| RXTYPE: [1] W-3-LP |EVENT DATE: 09/16/1999|
+------------------------------------------------+EVENT TIME: 01:55[EDT]|
| NRC NOTIFIED BY: KEVIN ABELL |LAST UPDATE DATE: 09/16/1999|
| HQ OPS OFFICER: STEVE SANDIN +-----------------------------+
+------------------------------------------------+PERSON ORGANIZATION |
|EMERGENCY CLASS: N/A |CHRIS CHRISTENSEN R2 |
|10 CFR SECTION: |ANNE BOLAND R2 |
|AARC 50.72(b)(1)(v) OTHER ASMT/COMM INOP | |
| | |
| | |
| | |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1 N Y 100 Power Operation |100 Power Operation |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| PARTIAL LOSS OF EMERGENCY SIREN CAPABILITY DURING HURRICANE FLOYD |
| |
| "The Plant was operating at 100% power when 22 Warning Sirens became |
| inoperable due to loss of power. The counties of Chatham, Harnett, and Wake |
| are each affected. Wind speeds in these areas are higher than normal due to |
| the effects of hurricane Floyd. One additional Warning Siren in Wake County |
| was previously inoperable due to failing its periodic test. Repairs will be |
| made when wind speed subsides." |
| |
| Harris has a total of 81 sirens of which 22 represents slightly greater than |
| 25%. Residents living within 5 miles of the site have tone alert radios as |
| a backup. The licensee informed the NRC resident inspector and will inform |
| state/local agencies. |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|Power Reactor |Event Number: 36171 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: LIMERICK REGION: 1 |NOTIFICATION DATE: 09/16/1999|
| UNIT: [] [2] [] STATE: PA |NOTIFICATION TIME: 04:30[EDT]|
| RXTYPE: [1] GE-4,[2] GE-4 |EVENT DATE: 09/16/1999|
+------------------------------------------------+EVENT TIME: 01:15[EDT]|
| NRC NOTIFIED BY: DOUG AMTSFIELD |LAST UPDATE DATE: 09/16/1999|
| HQ OPS OFFICER: DICK JOLLIFFE +-----------------------------+
+------------------------------------------------+PERSON ORGANIZATION |
|EMERGENCY CLASS: N/A |NIEL DELLA GRECA R1 |
|10 CFR SECTION: | |
|AIND 50.72(b)(2)(iii)(D) ACCIDENT MITIGATION | |
| | |
| | |
| | |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE |
+-----+----------+-------+--------+-----------------+--------+-----------------+
| | |
|2 N Y 100 Power Operation |100 Power Operation |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| - Secondary containment integrity lost due to a hatch cover being removed |
| during maintenance activities - |
| |
| At 0115 on 09/16/99. Limerick Generating Station Unit 2 experienced a loss |
| of secondary containment integrity. At the time of the event. the Standby |
| Gas Treatment (SBGT) System was in service. The Reactor Enclosure HVAC |
| System was not in service due to maintenance activities. The SBGT System was |
| unable to maintain reactor enclosure pressure greater than 0.25 inches of |
| vacuum water gauge per Technical Specifications due to a hatch cover being |
| removed for maintenance inspection activities. This event could have |
| prevented the fulfillment of the safety function of structures or systems |
| that are needed to control the release of radioactive materials or mitigate |
| the consequences of an accident. The hatch cover was reinstalled properly |
| by 0126 and the SBGT System was able to draw a vacuum on the reactor |
| enclosure area greater than 0.25 inches of vacuum water gauge. |
| |
| The licensee informed the NRC Resident Inspector. |
+------------------------------------------------------------------------------+
Page Last Reviewed/Updated Thursday, March 25, 2021