Event Notification Report for January 5, 1999
U.S. Nuclear Regulatory Commission
Operations Center
Event Reports For
01/04/1999 - 01/05/1999
** EVENT NUMBERS **
35200 35212 35214
+------------------------------------------------------------------------------+
|Power Reactor |Event Number: 35200 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: SURRY REGION: 2 |NOTIFICATION DATE: 12/28/1998|
| UNIT: [1] [2] [] STATE: VA |NOTIFICATION TIME: 11:16[EST]|
| RXTYPE: [1] W-3-LP,[2] W-3-LP |EVENT DATE: 12/28/1998|
+------------------------------------------------+EVENT TIME: 11:00[EST]|
| NRC NOTIFIED BY: JAMES HELM |LAST UPDATE DATE: 01/04/1999|
| HQ OPS OFFICER: DOUG WEAVER +-----------------------------+
+------------------------------------------------+PERSON ORGANIZATION |
|EMERGENCY CLASS: N/A |PIERCE SKINNER R2 |
|10 CFR SECTION: | |
|AESS 50.72(b)(1)(v) EMERGENCY SIREN INOP | |
| | |
| | |
| | |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1 N Y 100 Power Operation |100 Power Operation |
|2 N Y 100 Power Operation |100 Power Operation |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| EMERGENCY SIRENS INOPERABLE DUE TO WINTER WEATHER |
| |
| Virginia Power polled the 61 emergency sirens around Surry and found 17 that |
| did not respond. Troubleshooting is in progress on the sirens in question. |
| The cause of the failures is believed to be freezing rain which passed |
| through the area on 12/24/98. The polling was completed at 1100 EST this |
| morning. |
| |
| The licensee informed the NRC resident inspector and the State of Virginia |
| Department of Emergency Services. |
| |
| ***UPDATE AT 1012 EST ON 01/04/99 FROM WEBSTER TAKEN BY MACKINNON*** |
| |
| The licensee reported that the emergency sirens were returned to service at |
| 0930 EST on 01/04/99. |
| |
| NRC resident inspector was notified of this event update by the licensee. |
| The NRC operations officer notified the R2DO (Pierce Skinner). |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|Power Reactor |Event Number: 35212 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: CLINTON REGION: 3 |NOTIFICATION DATE: 01/02/1999|
| UNIT: [1] [] [] STATE: IL |NOTIFICATION TIME: 08:51[EST]|
| RXTYPE: [1] GE-6 |EVENT DATE: 01/02/1999|
+------------------------------------------------+EVENT TIME: 07:45[CST]|
| NRC NOTIFIED BY: MARSHALL FUNKHOUSER |LAST UPDATE DATE: 01/04/1999|
| HQ OPS OFFICER: STEVE SANDIN +-----------------------------+
+------------------------------------------------+PERSON ORGANIZATION |
|EMERGENCY CLASS: N/A |MONTE PHILLIPS R3 |
|10 CFR SECTION: |JOHN HANNON NRR |
|AARC 50.72(b)(1)(v) OTHER ASMT/COMM INOP |ROSEMARY HOGAN IRD |
| |JOSEPH HIMES RCT |
| |CHARLES MILLER NRR |
| | |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1 N N 0 Cold Shutdown |0 Cold Shutdown |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| LICENSEE CONCLUDED THAT THE EMERGENCY RESPONSE ORGANIZATION COULD NOT MEET |
| THE STAFFING TIME REQUIREMENT DUE TO ADVERSE WEATHER CONDITIONS. |
| |
| THE FOLLOWING TEXT IS A PORTION OF A FACSIMILE RECEIVED FROM THE LICENSEE: |
| |
| "10CFR50.72(b)(v) REQUIRES THE FACILITY TO NOTIFY THE NRC OPERATIONS CENTER |
| DURING ANY EVENT THAT RESULTS IN THE MAJOR LOSS OF EMERGENCY OFFSITE |
| RESPONSE CAPABILITY." |
| |
| "WEATHER CONDITIONS HAVE DETERIORATED DRIVING CONDITIONS PREVENTING MULTIPLE |
| PERSONNEL FROM REACHING THE PLANT. BASED ON THESE RESULTS AND PRESENT |
| WEATHER CONDITIONS, IT IS DOUBTFUL THAT THE EMERGENCY RESPONSE ORGANIZATION |
| WOULD BE FILLED WITHIN THE REQUIRED TIME. THUS, THIS NOTIFICATION [IS] |
| BEING MADE." |
| |
| THE LICENSEE PLANS TO INFORM THE NRC RESIDENT INSPECTOR. |
| |
| ***UPDATE ON 01/04/99 AT 1240 EST FROM R. POWERS TAKEN BY MACKINNON*** |
| |
| WEATHER AND DRIVING CONDITIONS ARE NO LONGER HAZARDOUS, AND THE LICENSEE CAN |
| FILL THE EMERGENCY RESPONSE ORGANIZATION POSITIONS AS OF 1135 CST ON |
| 01/04/99. |
| |
| THE NRC RESIDENT INSPECTOR WAS NOTIFIED OF THIS UPDATE BY THE LICENSEE. THE |
| NRC OPERATIONS OFFICER NOTIFIED THE R3DO (BRENT CLAYTON). |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|Power Reactor |Event Number: 35214 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: SAN ONOFRE REGION: 4 |NOTIFICATION DATE: 01/05/1999|
| UNIT: [] [2] [] STATE: CA |NOTIFICATION TIME: 03:19[EST]|
| RXTYPE: [1] W-3-LP,[2] CE,[3] CE |EVENT DATE: 01/04/1999|
+------------------------------------------------+EVENT TIME: 20:51[PST]|
| NRC NOTIFIED BY: HOWARD SMITH |LAST UPDATE DATE: 01/05/1999|
| HQ OPS OFFICER: STEVE SANDIN +-----------------------------+
+------------------------------------------------+PERSON ORGANIZATION |
|EMERGENCY CLASS: N/A |JOSEPH TAPIA R4 |
|10 CFR SECTION: | |
|AINB 50.72(b)(2)(iii)(B) POT RHR INOP | |
| | |
| | |
| | |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE |
+-----+----------+-------+--------+-----------------+--------+-----------------+
| | |
|2 N N 0 Cold Shutdown |0 Cold Shutdown |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| LICENSEE DETERMINED THAT THE CCW SYSTEM MAY NOT MEET ITS REQUIREMENT TO |
| OPERATE FOR 7-DAYS WITHOUT MAKE-UP FOLLOWING A SEISMIC EVENT |
| |
| "AT SAN ONOFRE, THE COMPONENT COOLING WATER (CCW) SYSTEM IS REQUIRED TO |
| PROVIDE COOLING FOR 7 DAYS WITHOUT MAKE-UP. CCW TRAINS A AND B ARE |
| SEISMICALLY QUALIFIED; THE NON-CRITICAL LOOP IS NOT SEISMICALLY QUALIFIED. |
| |
| "UNIT 2 ENTERED MODE 5 AT APPROXIMATELY 0544 PST ON JANUARY 3, 1999, FOR A |
| PLANNED REFUELING/MAINTENANCE OUTAGE. AT 2051 ON JANUARY 4, 1999, WHILE |
| UNIT 2 WAS IN MODE 5, SCE DETERMINED THAT ISOLATION VALVE LEAKAGE BETWEEN |
| CCW TRAIN B AND THE CCW NON-CRITICAL LOOP OBSERVED DURING A TS SURVEILLANCE |
| EXCEEDED IT ACCEPTABLE LIMIT FOR OPERATION IN MODES 1 THROUGH 4 AND TRAIN B |
| CCW COULD HAVE BEEN INOPERABLE PRIOR TO SHUT DOWN. TESTS WERE PERFORMED TO |
| ATTEMPT TO DETERMINE WHETHER THIS LEAKAGE EXISTED DURING OPERATION IN MODES |
| 1 THROUGH 4 PRIOR TO PLANT SHUT DOWN. HOWEVER, THE TESTS WERE UNABLE TO |
| DETERMINE THAT THE LEAKAGE DID NOT EXIST PRIOR TO SHUT DOWN. DURING THE |
| PAST CYCLE OF PLANT OPERATION, IF A SEISMIC EVENT WERE TO HAVE OCCURRED |
| WHILE TRAIN A WAS OUT OF SERVICE, THERE WAS A POTENTIAL FOR THE CCW TO FAIL |
| TO MEET ITS REQUIRED 7-DAYS OF OPERATION WITHOUT MAKEUP. THEREFORE, SCE IS |
| CONSERVATIVELY MAKING THIS REPORT AS A NON-EMERGENCY 4-HOUR REPORT IN |
| ACCORDANCE WITH 10CFR50.72(b)(2)(iii) - A CONDITION THAT ALONE COULD HAVE |
| PREVENTED THE FULFILLMENT OF THE SAFETY FUNCTION OF THE CCW. |
| |
| "CCW IS PRESENTLY CAPABLE OF PERFORMING ITS SUPPORT FUNCTION FOR SHUT DOWN |
| COOLING IN MODES 5 AND 6. THE ISOLATION VALVES' ACTUATORS WERE |
| DISCONNECTED, THE VALVES WERE MANUALLY SEATED. THE MEASURED LEAKAGE WAS |
| WELL BELOW THE ACCEPTABLE LEVEL FOR OPERATION IN MODES 1 THROUGH 4. THE |
| ACTUATORS WERE RE-CONNECTED TO PROVIDE FOR REMOTE OPERATION. THE |
| INVESTIGATION OF THE CAUSE AND CORRECTIVE ACTIONS IS ON-GOING.. |
| |
| "UNIT 3 IS IN MODE 1 AND UNAFFECTED BY THIS CONDITION." |
| |
| THE LICENSEE INFORMED THE NRC RESIDENT INSPECTOR. |
+------------------------------------------------------------------------------+