                                                                 1
 1                      UNITED STATES OF AMERICA
 2                    NUCLEAR REGULATORY COMMISSION
 3                                 ***
 4              ADVISORY COMMITTEE ON REACTOR SAFEGUARDS
 5                                 ***
 6            MATERIALS AND METALLURGY SUBCOMMITTEE MEETING
 7                  CALCULATION OF NEUTRON FLUENCE DG-1053
 8                                 ***
 9                           PUBLIC MEETING
10
11                    Nuclear Regulatory Commission
12                             Room T2-B3
13                        Two White Flint North
14                        11545 Rockville Pike
15                         Rockville, Maryland
16
17                     Thursday, November 16, 2000
18
19              The above-entitled meeting commenced, pursuant to
20    notice, at 8:33 a.m.
21
22    MEMBERS PRESENT:
23              WILLIAM SHACK, Chairman
24              DR. THOMAS KRESS
25              DR. ROBERT SEALE
.                                                                 2
 1    ALSO PRESENT:
 2              DR. NICHOLAS TSOULFANIDIS
 3              MR. NOEL DUDLEY
 4              DR. NILESH CHOKSHI
 5              MR. BILL HOPKINS
 6              DR. SHAH MALIK
 7              MR. BILL JONES
 8              MR. LAMBROS LOIS
 9              DR. JOHN CAREW
10              MR. TUCKER WARSHAM
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
.                                                                 3
 1                        P R O C E E D I N G S
 2                                                     [8:33 a.m.]
 3              CHAIRMAN SHACK:  The meeting will now come to
 4    order.  This is a meeting of the ACRS Subcommittee on
 5    Materials and Metallurgy.  I am Dr. William Shack, Chairman
 6    of the subcommittee.
 7              ACRS members in attendance are Thomas Kress and
 8    Robert Seale.  Also in attendance is ACRS consultant,
 9    Nicholas Tsoulfanidis.
10              The purpose of this meeting is for the
11    subcommittee to hear presentations by the staff concerned
12    the proposed final Regulatory Guide on Calculation and
13    Dosimetry Methods for Determining Pressure Vessel Neutron
14    Fluence.
15              The subcommittee will gather information, analyze
16    relevant issues and facts and formulate proposed positions
17    and actions as appropriate for deliberation by the full
18    committee.
19              Mr. Noel Dudley is the cognizant ACRS staff
20    engineer for this meeting.
21              The rules for participation in today's meeting
22    have been announced as part of this notice of this meeting
23    previously published in the Federal Register on October
24    25th, 2000.
25              A transcript of this meeting is being kept and
.                                                                 4
 1    will be made available as stated in the Federal Register
 2    Notice.
 3              It is requested that speakers first identify
 4    themselves and speak with sufficient clarity and volume so
 5    they can be readily heard.
 6              We have received no written comments.  A
 7    representative of Framatome requested the opportunity to
 8    make a statement at the end of the meeting.
 9              The ACRS examined Draft Regulatory Guide DG-1025,
10    Calculational and Dosimetry Methods for Determining Pressure
11    Vessel Neutron Fluence in 1993 and requested the opportunity
12    to review the proposed final version after public comments
13    were reconciled.
14              Subsequently, DG-1025 evolved into DG-1053.  The
15    staff briefed the subcommittee on the status of DG-1053
16    during its April 15th-16th, 1997 meeting.  More recently,
17    DG-1053 evolved into the final -- or into the proposed final
18    Regulatory Guide we are reviewing today.
19              During this evolutionary process, stakeholders had
20    opportunities to provide comments on the different versions
21    of the Regulatory Guide.  Today we will hear presentations
22    regarding the proposed final Regulatory Guide.
23              We will now proceed with the meeting, and I call
24    upon Dr. Nilesh Chokshi, Chief of the Materials Engineering
25    Branch, to begin.
.                                                                 5
 1              DR. CHOKSHI:  Good morning and thank you, and let
 2    me, I think as Dr. Shack mentioned, my name is Nilesh
 3    Chokshi.  I am the new Branch Chief of the Materials
 4    Engineering Branch, just about three months, and OPM placed
 5    the position last month.
 6              So, as such, this is my first presentation to this
 7    august body, and as it will happen, the subject matter is
 8    neutron fluence calculation and dosimetry, not the subjects
 9    I would have chosen for my first encounter.  Stresses and
10    strain is more of my language, but luckily, I have experts
11    which are going to take you through the evolution and the
12    technical bases -- the technical positions and the bases.
13              Then also we have an NRR expert here, so I think,
14    you know, we are ready to explain the bases.
15              Why I am here is really to, you know, tell what we
16    want to accomplish, why we here.  And I think you already
17    touched on some of those aspects.  I think that as you
18    pointed out, this process has been underway for quite some
19    time, and I think we are ready here to really go, follow
20    with the final publication of the final guide.  And what we
21    would like to do is go over the technical positions, discuss
22    the bases for those positions and some of the implementation
23    aspects.
24              During that process, we also want to discuss some
25    of the major public comments received, particularly on the
.                                                                 6
 1    last job for DG-1053, how we have addressed that, what
 2    changes have taken place because of those comments.  And,
 3    also, describe to you when we have not -- you know, why we
 4    have chosen not to accept certain comments.
 5              I am going to touch very briefly on the
 6    interactions which have taken place with the public, and I
 7    think, as both the presentations, you will see more, you
 8    know, what was the involvement, to what extent.
 9              We are here to seek, starting with this
10    subcommittee, the ACRS approval to go forward and publish
11    the final Regulatory Guide.  And I think we are the stage
12    that the guide is ready to go forward.
13              Of course, I will just take it briefly and
14    discuss.  The guide, it basically standardizes the methods
15    for the fluence calculations and use of the dosimetry.
16              CHAIRMAN SHACK:  Excuse me.  I really don't know a
17    whole lot about this subject.  But there is an awful lot of
18    references to consensus standards that seem to cover much of
19    this ground.  Is there a reason you need your own Regulatory
20    Guide rather than relying on consensus standards?
21              MR. LOIS:  The answer is yes.  I am Lambros Lois,
22    Reactor Systems Branch.  The reason is that because of the
23    existence of a variety of methods and techniques, people
24    have been using them to their own advantage, so to speak. 
25    In other words, they use whatever produces the best results. 
.                                                                 7
 1    This guide is based on --
 2              CHAIRMAN SHACK:  Well, that's what we want, the
 3    best results, right.
 4              MR. LOIS:  Well, results which satisfy specific
 5    objectives.  The fundamental, the basis or the premise for
 6    this guide is the requirements of GDC-1430 and 31 which
 7    describe qualitatively what are the requirements that should
 8    be fulfilled for the materials and, therefore, for the
 9    neutron fluence.  So that is the reason why we need to have
10    a standard rule of flux.
11              As a matter of fact, there was a great deal of
12    confusion that persists even today -- well, not confusion,
13    but I should say created confusion as to what is the
14    appropriate way of doing it, and that expresses the staff's
15    intent.
16              DR. CHOKSHI:  Yeah, I think the second bullet was
17    basically that there is a wide variety of the existing
18    methods and guidance is needed because this basically
19    applies to a number of regulatory requirements, Appendix G
20    and H of Part 50, 10 CFR 50.61, the whole PTS issue.  So
21    that, I think, is standardized approach, or at least a known
22    approach will be a much better, I think, situation.
23              And you went over the brief history, you know, as
24    you said, the initial approach was started in '93.  Research
25    received, it was only later in '92, and there have been
.                                                                 8
 1    several drafts.  I think when John Carew goes through that,
 2    you will see why this has taken -- how the scope has changed
 3    over the period, and there several public comments periods,
 4    you know, we have sent several drafts out for the public
 5    comments, a number of public meetings.
 6              The last round of comments was on the DG-1053,
 7    which we received the comments in May and then I think since
 8    that, we have been revising the guide.  And I think at this
 9    point in time the guide is ready.  We have been also
10    discussing with NRR and OGC and other people.  And if
11    everything goes according to the plan, I think we should be
12    able to publish the guide probably next year, hopefully,
13    sometime in the spring.
14              So what I want to do is, with this brief
15    introduction I think what I will propose to do is --
16              CHAIRMAN SHACK:  Let me ask just one other
17    question now.
18              DR. CHOKSHI:  Sure.
19              CHAIRMAN SHACK:  Do you think this is going to
20    impact those people that have sort of potential PTS
21    problems?  I mean Beaver Valley and Palisades are the ones
22    that come to mind.  You know, will the changes introduced by
23    the guide affect those calculations?
24              DR. CHOKSHI:  I will have Lambros --
25              MR. LOIS:  Yes.  Again, this is Lambros Lois.  We
.                                                                 9
 1    essentially have been working for the last year or two out
 2    of the Draft Guide.  So essentially both these two plants,
 3    as well as others, have adopted the methods that are
 4    promulgated there.  The only difference is that is what left
 5    to be done is just make it official.
 6              DR. CHOKSHI:  Yeah.  I think that is important and
 7    I think my understanding is that people have been already
 8    using a number of the benchmark problems, a number of things
 9    which have been already out.
10              CHAIRMAN SHACK:  This is not a --
11              DR. CHOKSHI:  You know, the knowledge is out there
12    and people are already applying it, I think.  And the reason
13    I say it is, you know, Dr. Carew is going to make a
14    presentation, but I think I will have Bill Jones of Research
15    and he is going to give an overview sort of, and then John
16    is going to talk about the details of the technical
17    positions, also how the benchmark problems and the NUREG,
18    and then public comments.  And I think in the end, we will
19    come back and Bill will close, go over the summary and the
20    schedule.
21              So, if there are no more questions, I think I will
22    ask Bill to come and give his presentation.
23              MR. JONES:  I am Bill Jones, and I have been the
24    Project Manager on this Draft Guide and Reg. Guide for about
25    a year, year-and-a-half, and so what I really want to do is
.                                                                10
 1    give you an overview before Dr. Carew gets into the details. 
 2    That is really why I am here.
 3              And as your slides indicate, I want to talk about
 4    a couple of things as a way of bridging into what John is
 5    going to talk about.  The objectives of the Reg. Guide and
 6    then the contents of the guide.  And I think if I go over
 7    the contents, it will -- the guide, it is not a small
 8    document, so my objective would be to sort of stress what is
 9    in there and sort of break it out into three parts, because
10    that is really what is there.
11              So, our objectives were and are to provide methods
12    and describe those methods and make them consistent for both
13    calculation and dosimetry, for both calculation and
14    measurement.  And if a licensee chooses to use these, then
15    these methods would satisfy our regulations.
16              And we have detailed descriptions of the fluence
17    calculations, discrete ordinates Monte Carlo, how dosimetry
18    measurements can be used, and the procedures for
19    qualification and determination of uncertainty.
20              And I already talked about measurement, but there
21    is a lot of information in there about -- there is a
22    substantial amount of information in there about dosimetry.
23              The document itself is really -- the regulatory
24    position is really in three parts.  The neutron fluence
25    calculational methods, and we talk a lot about that, we lay
.                                                                11
 1    that out in terms of how you would construct the problem and
 2    where you get your cross-section.  We talk about neutron
 3    sources, which are pretty important to get from the outside
 4    of the core fuel to the vessel.  We talk about qualification
 5    and uncertainty.
 6              Okay.  Part 1 is fluence calculational methods,
 7    Part 2 is fluence measurement methods.  And so we talk about
 8    dosimetry.  We give a lot of cautions in the dosimetry and
 9    we talk about dosimetries that can be used.
10              In the last part, in the sort of technical part is
11    reporting.  We talk about how we would expect licensees to
12    make this information available to us, to the staff.  And
13    not part of the regulatory position, but also we talk about
14    implementation, how the staff plans to use the information
15    that the Draft Guide talks about.
16              So there's three parts really, there's
17    calculational, there's measurement, and then there's
18    reporting.  So those are the three main parts, the
19    semi-technical parts of the guide.
20              That's really all I had to say.  I am really
21    trying to outline it, lay it out for you so that John can
22    get into the details.
23              The last slide in the smaller package talks about
24    summary, and we will come back to that at the end of the
25    staff presentation.
.                                                                12
 1              Do I have any questions?
 2              CHAIRMAN SHACK:  Is the fluence calculation that
 3    you do here consistent with what is assumed in 1.99 when you
 4    are looking at toughness variations through the wall and,
 5    you know, there is an implied fluence variation built into
 6    that?
 7              MR. JONES:  Lambros, do you want to --
 8              MR. LOIS:  Yes.  This is Lambros Lois.  This guide
 9    is a supplement to 1.99.  1.99 deals with the materials end
10    of it, and this proposed guide deals with the fluence
11    portion of that.  The assumed value is what is in this
12    guide.  In other words, the quality or the rigor, or the
13    methodology, the assumptions in 1.99 are listed in this
14    guide.
15              CHAIRMAN SHACK:  Okay.  But isn't there an implied
16    fluence variation built into 1.99 when you are looking at
17    the throughwall variation of the fluence?  At the inner
18    wall, you start here.
19              MR. LOIS:  Yes.  Yes.  Right.
20              MR. JONES:  The calculational method that we are
21    really talking about here, in parallel with 1.99, says, how
22    do I get my fluence at the vessel wall?  1.99 has the
23    exponential coastdown, whatever -- I am searching word and I
24    can't find it.  The exponential -- the reduction in the
25    fluence as you go through the wall, that it is explicitly
.                                                                13
 1    listed in 1.99, right.
 2              So, in 1.99, you need to use still that --
 3              CHAIRMAN SHACK:  Well, I guess that is my
 4    question.  You have this rigorous method for calculating the
 5    fluence.  Why do you then use a different method in 1.99?
 6              MR. JONES:  Well, 1.99, we are thinking about --
 7    Shah, do you want to talk about that?
 8              DR. MALIK:  Talk about the PTS reactivities.  What
 9    you are talking about, -- this is Shah Malik.
10              MR. JONES:  Attenuation, right.
11              DR. MALIK:  Attenuation factor.  Shah Malik,
12    Office of Research, Materials Engineering Branch.  You are
13    talking about attenuation factor, that is an approximate
14    exponential minus .24X there.  That is an approximation
15    which, when we do the tail -- calculation, we have found
16    that, at least for the first quarter thickness of the
17    vessel, that attenuation is very close or just a little less
18    than the found from this Reg. Guide.
19              CHAIRMAN SHACK:  Okay.  So it is consistent?
20              DR. MALIK:  It is consistent.  And as you go
21    further towards the outer surface, the attenuation factor
22    there is I think lower than what you see here.  So it is
23    more conservative, exponential .24X is more -- minus .24X is
24    more conservative than you find in front here.
25              MR. JONES:  We have taken the attenuation and we
.                                                                14
 1    have laid the actual calculation right on top of it.  And
 2    the description Shah gave is correct, I mean that is a good
 3    description.  They are not inconsistent, they are not very
 4    inconsistent.
 5              CHAIRMAN SHACK:  Are there any more questions? 
 6    Are there any more questions?
 7              [No response.]
 8              CHAIRMAN SHACK:  And I just want to say we
 9    appreciate your time and letting us come talk to you about
10    this.  And so without trying to bridge into it and dividing
11    the Draft Guide into three parts, I am going to introduce
12    Dr. John Carew from Brookhaven, who has been involved in the
13    Draft Guide since it was started.
14              DR. CAREW:  I'm John Carew, and I will be
15    discussing, I will be reviewing some of the details of the
16    Regulatory Guide DG-1053 on Calculation and Measurement of
17    Pressure Vessel Fluence.  I will also be discussing the
18    resolution to the comments we received from industry in May
19    and then I will finally be discussing the NUREG report which
20    describes the pressure vessel fluence benchmark problems.
21              Let me first note that the reactor pressure vessel
22    fluence is required for the determination of vessel
23    embrittlement and lifetime and the vessel fluence is used to
24    determine the adjusted reference temperature for the
25    nil-ductility transition, RTNDT, and also the fluence is
.                                                                15
 1    required input for the PTS Rule 50.61 for the termination of
 2    the reference temperature for PTS.
 3              The problem with the fluence stems from a
 4    combination of several factors, and this includes, first of
 5    all, the neutron fluence undergoes -- and this is the key
 6    item, the problem, the neutron fluence undergoes several
 7    decades of attenuation between the core and the pressure
 8    vessel.
 9              And here in the next slide we have, this is the
10    pressure, here is the core, barrel, thermal-shield and
11    pressure vessel, and as the neutrons propagate from the core
12    out to the vessel inner wall, they undergo three decades of
13    attenuation.  And as shown in the next slide, this is the
14    group 1 flux, the flux in the group right around 1 MeV.  You
15    can see the flux is basically flat.  The neutron flux is
16    basically flat in the core region and drops dramatically as
17    it goes into the water region.  There is a spectral change
18    right in front of the steel region, the core barrel, it
19    shifts upward, then drops again down into the spectral shift
20    here in front of the thermal-shield in the vessel.  But you
21    can see it drops three or more than three orders of
22    magnitude, and that is the problem.
23              As a result of this strong exponential
24    attenuation, the calculation of the fluence is extremely
25    sensitive to the material and geometry representation of the
.                                                                16
 1    core and vessel internals, the core and neutron source, and
 2    the transport and numerical schemes.  As a result, to get an
 3    accurate prediction of the fluence, you require detailed,
 4    multi-group, multi-dimensional calculations.
 5              Now, in practice, in performing these
 6    calculations, to facilitate these calculations, there are a
 7    wide range of fluence method approximations and methods that
 8    are used, and these include, for example, cross-section
 9    sets, the treatment of the core neutron source, the axial
10    synthesis treatment and the various computer codes that have
11    evolved over the years to simplify this problem.
12              And, in addition, because of the limited number of
13    surveillance capsule and benchmark data, and the uncertainty
14    in these data, it is very difficult to determine what the
15    accuracy of these fluence predictions are to benchmark them. 
16    And this is complicated by the fact that you really need an
17    accurate prediction of the fluence for several of the
18    vessels because of the limited margin to the NIIRTPTS.  And
19    this is the basic problem, and this problem is addressed by
20    the Reg. Guide which provides procedures and methods for
21    doing measurements and calculations that determine the
22    fluence to within an accuracy of the order of less than 20
23    percent, which is the requirement for the PTS rule.
24              DR. SEALE:  John.
25              DR. CAREW:  Yes.
.                                                                17
 1              DR. SEALE:  I started my career in this business
 2    doing shielding calculations, and I have always had a
 3    considerable amount of disdain for those people who look
 4    down their nose at an uncertainty of a factor of 10 in a
 5    shielding calculation, and not appreciate the fact that you
 6    have this several orders of magnitude of degradation due to
 7    the attenuation.
 8              By looking back on your sketch, and I realize that
 9    is all it is, the neutron flux versus radius.
10              DR. CAREW:  Right.
11              DR. SEALE:  The cavity is the region beyond the
12    outside of the core?
13              DR. CAREW:  Right, that is outside the vessel.
14              DR. SEALE:  Yeah, I mean outside the vessel. 
15    There is some exponential attenuation that is taking place
16    in there.
17              DR. CAREW:  Well, it is really not -- there is no
18    material, it is a vacuum basically.  There was some air in
19    there.
20              DR. SEALE:  I'm sorry, there is some --
21              DR. CAREW:  Geometrical attenuation.
22              DR. SEALE:  Geometric attenuation, yes.
23              DR. CAREW:  Exactly, right.  Yeah, and it is very
24    slight, it is small compared to the material attenuation,
25    but it is still there, and the calculation reflects that,
.                                                                18
 1    but on this scale you really can't see it.  But you are
 2    exactly right.
 3              DR. SEALE:  Yeah.  Yeah.  Essentially maybe --
 4              DR. CAREW:  1 over R squared or --
 5              DR. SEALE:  Yeah.  Well, as a matter of fact, if
 6    you multiplied the flux by R squared --
 7              DR. TSOULFANIDIS:  It is not 1 over R square. 
 8    Neutrons are streaming out.
 9              DR. CAREW:  Well, it is cylindrical geometry, you
10    know.
11              DR. SEALE:  I appreciate that.  Well, it is 1 over
12    R, I'm sorry, roughly.  In the cylindrical geometry, it is
13    pretty close.
14              But the point is that that is not exactly flat.
15              DR. CAREW:  Exactly, right.
16              DR. SEALE:  Okay.
17              DR. CAREW:  Okay.  Let's see.  So now, all right,
18    let's see.  So in the following, I will be discussing the
19    Regulatory Guide, reviewing some of the major points in the
20    Regulatory Guide.  I will be discussing how we resolve the
21    recent May NFE comments and the benchmark problem analyses.
22              Okay.  Let me start with the Regulatory Guide. 
23    The Regulatory Guide was developed by the Materials
24    Engineering Branch of the Office of Nuclear Regulatory
25    Research by Brookhaven National Laboratory with input from
.                                                                19
 1    NIST and from Oak Ridge.
 2              The purpose of the guide was to document
 3    calculation and measurement methods for determining pressure
 4    vessel fluence that are acceptable to the NRC.  The scope
 5    included vessel determination for input to the PTS rule and
 6    to the Reg. Guide 1.99 and Appendix G.
 7              The Reg. Guide included a very detailed
 8    description of the fluence calculation and measurement
 9    methods, procedures for qualifying the calculations and
10    measurements, a table of specific modeling, dosimetry
11    qualification and reporting requirements, and it requires
12    the calculation of the benchmark problems in NUREG-6115.
13              In calculating the fluence, the primary
14    calculational tasks, as you might expect, or the major tasks
15    are, first, the determination of the geometrical and
16    material composition data.  Second -- of the configuration,
17    the vessel out through the barrel, from the core out through
18    the barrel and downcomer into the vessel.  The second step
19    is to determine where -- how many neutrons are we producing. 
20    And that is the determination of the core neutron source,
21    which is relatively complicated.  And, finally, the
22    propagation of a neutron source in the core out to the inner
23    wall of the vessel.  These are the three major steps in the
24    calculation.
25              CHAIRMAN SHACK:  John, how do you average that?  I
.                                                                20
 1    mean, you know, the fuel is burning during -- as you
 2    rearrange the core and as you reload fuel.  What averaging
 3    do you do in the time variation here?
 4              DR. CAREW:  Well, first of all, you have to
 5    recognize that 85 percent of the source is coming from the
 6    peripheral -- the bundles in the periphery of the core.  And
 7    what you really need to know is what is the power -- well,
 8    basically, what is the power in each one of those
 9    assemblies.  And you can integrate that over each cycle and
10    determine what the power produced.
11              Then the next question is, where is the power --
12    from which isotopes if the power being produced?  And you
13    get that from fairly -- a fairly good reading on that from
14    the standard cell the physics people use, the core designers
15    use in the cell calculation.  They can tell you you have 50
16    megawatts or a certain number of megawatts coming from a
17    specific bundle, they can tell you that 50 percent is coming
18    from the U-235, 34 percent is coming from the plutonium-239,
19    et cetera.  So you can determine which isotopes the power is
20    coming from, and then, given that, you know what the -- you
21    can determine, you knew what the nu over kappa is, and which
22    it tells you how many neutrons per MeV are being produced. 
23    And then, finally, there is good data on how those neutrons
24    are distributed in energy from the neutron spectra.
25              So, you first sum that up over the cycles.  Now,
.                                                                21
 1    any point on the vessel really doesn't see one bundle, it
 2    sees several bundles, probably three or four bundles on the
 3    periphery.  So have the benefit of, you know, in addition,
 4    you are adding out over many cycles, so you are not that
 5    sensitive to a given particular bundle.  You may be high in
 6    one cycle, but low in the next cycle.
 7              But you touched on it -- well, there is another
 8    complication in the fact that there is a gradient on the
 9    periphery of the core, the peripheral, the fuel, the pins,
10    you know, there is a gradient on the bottom, on the outside
11    of the core that doesn't go off abruptly like a step
12    function, and you have to account for that also.  There is a
13    benefit for that because the fluence is using it, treating
14    it as a step function would over-predict the fluence.  So
15    you have to account for that.  And the pin powers are --
16    those are well determined.
17              But that is an excellent question, because it
18    turns out that one of the major uncertainties in the fluence
19    prediction is the source.  Basically, there are two
20    dominants.  In the calculation of the fluence, there are
21    really two important uncertainties.  One of them is the
22    source.  How much power is being produced in those
23    peripheral assemblies?  And there is a substantial, as you
24    might -- as you probably understand, there is a substantial
25    uncertainty in that prediction.
.                                                                22
 1              And, secondly, in many vessels -- in some vessels,
 2    there is some uncertainty in the inside diameter of the
 3    vessel.  And because of the strong exponential attenuation
 4    of the fluence, any displacement of that vessel introduces a
 5    significant amount of uncertainty.  So that is the other
 6    major uncertainty in the calculations.  That's how you
 7    determine what the source is and what the powers, you have
 8    to sum that over each cycle.
 9              CHAIRMAN SHACK:  So the geometry is actually a
10    major source of uncertainty.
11              DR. CAREW:  Yeah, exactly, and it is because the
12    -- the problem would go away if everything was flat.
13              Okay.  Right.  Now, let me go to the next slide. 
14    This slide is the -- I just might say that there are two
15    methods that the guide allows to the calculation to be done. 
16    You can use a discrete ordinates transport method or you can
17    use Monte Carlo.  And I will just, I will start with the
18    discrete ordinates method.
19              And, as I mentioned before, this is a flow diagram
20    of the calculation, and the calculation really takes place
21    by this code here, DOT, discrete ordinates transport, DOT. 
22    There are later versions of that called DORT and DOORS, but
23    they were basically the same code.  And this is the code
24    that calculates the fluence, the transport of the neutrons
25    from the core to the vessel.
.                                                                23
 1              Now, to do that calculation, you need, first of
 2    all, the input of the core geometry -- the system geometry,
 3    and that is fed in here from the left, the core internals
 4    vessel geometry.  And then, secondly, you need to know what
 5    is in those regions, what material is in those regions, and
 6    that comes from this region, from this component here.  You
 7    feed in the component material composition, which is
 8    combined with the microscopic neutron scattering cross
 9    sections.  They are fed into the code and these determine
10    the strength of attenuation in each one of the regions.
11              And then finally you need to know the source.  You
12    need to know how many neutrons are being produced in the
13    core.  And that comes from a combination of, first of all,
14    the cycle-dependent assembly pin and powers and exposures. 
15    You need to know the exposure because, as the exposure
16    accumulates in the bundle, you get more and more plutonium
17    present and plutonium produces more neutrons per energy MeV
18    and it produces a harder, faster neutron, so they propagate
19    more readily to the vessel.  And, consequently, higher
20    exposure bundles are more of a concern because they produce
21    a higher fluence.
22              So you need to know the exposure and then also you
23    take the amount of neutrons, the power and exposure being
24    produced, combine that with a spectrum, the energy
25    distribution of those neutrons.  That is fed into this code,
.                                                                24
 1    and it transports the codes out to the vessel.
 2              There is one additional complication, this
 3    calculation is so complicated that actually you typically
 4    just do a planar calculation in R theta geometry, and then
 5    you do an axial calculation, and then you do a synthesis to
 6    combine then and that is the step here.  So that is
 7    basically how the calculation is carried out.
 8              CHAIRMAN SHACK:  Is your technology robust enough
 9    that if somebody, you know, starts burning mixed oxide, that
10    you change the inputs, obviously, but have you changed the
11    basic technology here?  Is the guide still valid?
12              DR. CAREW:  As you pointed out, you change the
13    input.  The exposure would be more and, consequently --
14    well, not just exposure, but, as I mentioned, with high
15    exposure, you get a higher inventory of plutonium.  And, as
16    a matter of fact, after two or three cycles, the fraction of
17    plutonium being -- the fraction of fissions in the plutonium
18    is like 70 percent.  So for high, we only put -- let me
19    write that down, 60 percent, so with a high burnup bundle,
20    you are getting 60 percent of your fissions in plutonium
21    already.
22              Now, if you go to mixed oxide fuel, you probably
23    would go even higher, but all the arithmetic and all the
24    mechanism and all the algorithms are all the same basically. 
25    There would just be a little more plutonium.
.                                                                25
 1              DR. SEALE:  It starts sooner.
 2              DR. CAREW:  It starts sooner, right.  And so that
 3    is the basic calculational scheme.  And I will just say in
 4    passing that one of the comments in the round two comments
 5    was that they wanted not only discrete ordinates capability,
 6    they wanted us to address how you do Monte Carlo
 7    calculations.
 8              Go ahead.
 9              CHAIRMAN SHACK:  For one second.  When I looked at
10    the public comments, most of them seemed to be more on the
11    clarification order, and then I came to the one from the
12    professor at Penn State who said the whole thing wouldn't
13    work for BWRs.
14              DR. CAREW:  I will discuss that.
15              CHAIRMAN SHACK:  Okay.  You are going to discuss
16    that.
17              DR. CAREW:  Right.  Right.  So one of the round
18    two comments, I guess that was in '96, was to expand the
19    scope of the guide, and this was a substantial expansion,
20    for a couple of reasons.  First of all, at the time that it
21    was suggested, Monte Carlo was really not being used for
22    this calculation, for various reasons.  And so it was new
23    technology, it had never been accepted by the NRC really,
24    but we expanded the scope and have included Monte Carlo in
25    both the Regulatory Guide and also in the benchmark
.                                                                26
 1    problems.
 2              But, in any case, the Monte Carlo capability is
 3    really not very much different than the discrete ordinates. 
 4    It is basically the same.  The only thing different is this
 5    code here, the transport of the neutrons from the core to
 6    the vessel is carried out, instead of a deterministic
 7    discrete ordinates space energy mesh type of calculation, it
 8    is carried out in a statistical manner where neutrons are
 9    started off and their trajectories are followed as they go
10    from the core out through the various scattering events, out
11    to the vessel inner wall, and the tallies are summed and an
12    estimate of the fluence is determined.
13              The advantage, of course, is that all the surfaces
14    in the problem are modeled exactly and the geometry is a
15    true, high fidelity, exact fidelity, basically,
16    representation of the geometry.  Of course, the complication
17    is that because of this attenuation in the core, that you
18    are dropping by three decades, it takes -- you have to start
19    off a thousand neutrons in the core before one will
20    eventually arrive in the vessel.  They all disappear before
21    they get there, which means the statistics, if you run a
22    calculation, the variants in your edit will be you will
23    never get any neutrons.  There will be so few neutrons that
24    your statistics are very, very poor, and that is the
25    complication.  So you win, but you also lose.
.                                                                27
 1              So, anyway, this is basically -- this has all been
 2    included in the guide and in the benchmark problems.
 3              DR. TSOULFANIDIS:  John
 4              DR. CAREW:  Yes.
 5              DR. TSOULFANIDIS:  Nick Tsoulfanidis, ACRS
 6    consultant.  You might mention one advantage of Monte Carlo
 7    is you may have continuous energy cross sections, however,
 8    whatever uncertainty you have the source, it is the same for
 9    both methods.
10              DR. CAREW:  Exactly.  Right.  Yeah.  That's a good
11    point.  One thing I didn't mention, the advantage of the
12    Monte Carlo is that not only do you get a sense of doing it
13    statistically, you can include the exact cross sections
14    continuously.  So if you have an event, you can sample from
15    the energy and find out what the energy was and go look up
16    the cross sections at that specific energy, where in a
17    discrete ordinates calculation, you have to assume that you
18    break the energy range into discrete intervals.
19              And it turns out that that approximation is not --
20    with the number of groups that we use, we can get a pretty
21    good idea of what the error is by going from a large number
22    of groups down to smaller groups and see how the error, how
23    it changes.
24              So the technology is well developed and we have
25    got -- we know the values, or we know where all the
.                                                                28
 1    approximations are.
 2              Okay.  The next item I would like to discuss is
 3    the qualification.  We have these methods, and now, as
 4    required by Appendix B of 10 CFR 50, the methods must be
 5    qualified.  And how do we assure that they are valid and
 6    accurate?
 7              The guide requires that this take place in two
 8    steps basically.  The first step would be do an analytic
 9    determination of the uncertainty.  And that means we take
10    the computer code and we perform some numerical sensitivity
11    calculations where we perturb each one of the input
12    parameters and see what the change in the edit is, the
13    fluence is.  And once we know what all the sensitivities
14    are, and, of course, we would be focused on the vessel
15    diameter, what the sensitivity to the vessel diameter change
16    is, and, of course, what the change in the source is, what
17    the effect is.  And there is other uncertainty as well, but
18    they are the major ones.
19              So we determine what the sensitivity is, and then,
20    using that sensitivity, we combine that with estimates of
21    what the source uncertainty would be and what the
22    sensitivity -- what we think the vessel diameter uncertainty
23    is.  And I might add that for some vessels we have a lot of
24    measurement data, and we have a very good idea what the
25    uncertainty in that vessel, you know, they go through the
.                                                                29
 1    vessel, around the circumference of the vessel and take
 2    various measurements, and we have looked at those, and you
 3    have a lot of data.  You can get a mean value, you can get a
 4    standard deviation.  You can get an idea of what the
 5    uncertainty of that vessel diameter is.  Other vessels, we
 6    have very little data.  So it varies from plant to plant.
 7              But if we have a lot of good data, there is a very
 8    good indication of what the uncertainty would be.  And so
 9    this is one technique.
10              But we have to recognize there are some situations
11    where we have very little data and this would not provide a
12    good estimator of what the fluence uncertainty is.  So we
13    have to do more than one -- have more than one path.
14              And this other path is basically comparing
15    predictions to benchmarks.  And there's several types of
16    benchmarks.  We have some plants have extensive operating
17    dosimetry surveillance capsule data.  So, for those plants,
18    we would be looking at dosimetry data.
19              Also, there are available some pressure vessel
20    simulator experiments, the PCA and other experiments that
21    have been done, that also provide extensive dosimetry and
22    good measurements, so that is another path.
23              And then finally we have a benchmark problem,
24    NUREG-6115, which provides a definition problem, a well
25    defined, complete problem to calculate and reference
.                                                                30
 1    solution.
 2              So we would go through this qualification
 3    procedure and we would determine what the uncertainty would
 4    be, and that is the qualification path.
 5              Now, for the PTS rule, we should show that the
 6    uncertainty has to be less than 20 percent.  Now, in the
 7    next slide.  Now this is a figure that was suggested by one
 8    of the commenters from Bechtel, actually Bill Hopkins.  And
 9    what this does, in the guide, the PTS rule requires an
10    uncertainty of 20 percent.  And what do we do if the
11    uncertainty is greater than -- what does a licensee do if
12    the uncertainty is greater than 20 percent?
13              Well, this diagram shows clearly, describes how we
14    address that situation.  If the uncertainty evaluation, if
15    the uncertainty is less than 20 percent, we just proceed and
16    we use the calculated value and apply, if there is a bias
17    that we want to apply, we can just multiply by the bias, and
18    we get the result.
19              The complication occurs if the uncertainty is
20    greater than -- well, the uncertainty is greater than 30
21    percent, the guide is no longer applicable.  This would
22    require a case-specific review.  On the other hand, if the
23    uncertainty is between 20 and 30 percent, we have the option
24    where you can reduce the fluence value by an amount that
25    would preserve the probability -- it would ensure that the
.                                                                31
 1    probability of an under-prediction is not increased.  So in
 2    this case there is a penalty applied to the fluence.
 3              DR. KRESS:  What is the basis for the selection of
 4    those percentage acceptance values?
 5              DR. CAREW:  Which, the 20 percent?
 6              DR. KRESS:  Any one of them.
 7              DR. CAREW:  Well, okay, the 20 percent is part of
 8    the -- is what was assumed in determining the PTS criteria
 9    rule.  They allocated 20 percent uncertainty for the
10    fluence, so that is where the 20 percent comes from.
11              Now, the 30 percent is a number that we think this
12    is a reasonable -- if someone has a 30 percent uncertainty,
13    this is a reasonable uncertainty.  It may not be that
14    surprising, and, therefore, we allow them to use that
15    calculation, but they must -- the value must be reduced. 
16    The value of the fluence must be reduced by an amount such
17    that the probability of an under-prediction is not
18    increased.  And then 30 percent, above 30 percent, we feel
19    that that calculation really requires a special review, it
20    is outside the scope of the guide.
21              MR. LOIS:  John.  This is Lambros Lois again.  It
22    is rather of historical significance.  Way back in the early
23    '80s when we were putting together 10 CFR 50.61 with the PTS
24    rule, we were required to have -- to come up with an
25    uncertainty.  At that time, both calculational tools and
.                                                                32
 1    measurements were not -- measurement database was not
 2    available.  So we utilized, actually, it was John who did
 3    that, utilized sensitivity calculations, and we concluded
 4    that 20 percent would be a reasonable uncertainty.
 5              That was folded into the uncertainty or in the
 6    penalty, if you wish, term on 50.61, on 10 CFR 50.61, and
 7    that is where it stayed and ever since has been part of the
 8    calculation.  And nowadays both databases are wider and have
 9    more data, and the calculation techniques are accurate.  So
10    we can do better, but because it was incorporated in the
11    original 50.61, it still stays there.  So that is the reason
12    why it is 20 percent.
13              DR. CAREW:  Okay.  All right.  Let's see.  The
14    next slide is the measurements and then, let's see.  Okay.
15              So, in summary, --
16              CHAIRMAN SHACK:  A question.
17              DR. CAREW:  Go ahead.
18              CHAIRMAN SHACK:  If you can do better, do you get
19    any credit?
20              MR. LOIS:  In the uncertainty, you can do better,
21    yes.  You get credit automatically because you have a
22    smaller uncertainty.  Now, unfortunately, the interns of the
23    penalty or -- you don't, because it has to be folded with
24    the materials and that is a mess.  I mean, you know, it is
25    very difficult to do that.
.                                                                33
 1              DR. TSOULFANIDIS:  What is the basis for taking
 2    the second step, the 30 percent, and now saying if it is 20
 3    and one treatment 20 or less and one treatment 20 and above?
 4              MR. LOIS:  The gentleman who proposed that, and we
 5    have adopted it, is sitting in the back there, Bill Hopkins. 
 6    It is just an intuitive number, just an educated guess.  You
 7    feel that the 30 percent is way too out, so we don't want to
 8    continue with that calculation.  There is no specific
 9    technical reason for that, like the 20 percent.
10              DR. CAREW:  But we ensure, if they are in the
11    range from 20 to 30, that the probability of an
12    under-prediction of a fluence is maintained.  So we apply a
13    penalty to ensure that when you are in that range, that
14    things are not degenerating.
15              Okay.  In summary, the Regulatory Guide provides a
16    best estimate rather than a bounding fluence.  In other
17    words, all the assumptions that go into the Reg. Guide were
18    carefully made so that it is a best estimate, we are not
19    doing any bounding calculations.  If the guide is followed,
20    the accuracy should be less than 20 percent 1 sigma, and the
21    energy range is from 15 MeV down to .1 MeV.  The
22    qualification is by benchmarking and uncertainty analysis.
23              The applicability of the guide includes -- well,
24    first of all, it provides input for Appendix G and Reg.
25    Guide 1.99, the PTS rule.  It is applicable to both PWR and
.                                                                34
 1    BWR core vessel geometries and fuel designs.  I might add
 2    that initially, back in -- we did the 1025, the initial Reg.
 3    Guide was not really applicable to BWRs, but in the round
 4    two questions in '96, we were asked to include that, and
 5    that, again, was a substantial increase in the scope of the
 6    guide.  But that has been included.  So now we are
 7    applicable to both BWR and BWR cores and fuel designs.  And,
 8    importantly, the guide is also applicable to those core
 9    designs that are constructed for fuel -- vessel fluence
10    reduction, such as the low leakage cores, the partial link
11    shield assembly cores and the life extension calculations,
12    and also the mixed oxide fuel, now that you mention that.
13              I was going to review the status of the guide. 
14    The initial release was in 1993.  At that time we had the
15    ACRS subcommittee and committee meetings.  We met with the
16    CRGR.  We released the guide for comment.  We had a set of
17    round one comments that were evaluated and incorporated in
18    the guide.
19              We had a follow-up meeting with industry in
20    September 18th, '96 where we reviewed the comments and the
21    resolution.  At this meeting, I mentioned there were several
22    changes in the scope of the guide.  The Monte Carlo was
23    added to both the guide and the NUREG problems report, and
24    also the BWR was incorporated.
25              In September, and then in September '99, a year
.                                                                35
 1    ago last September, we met again with industry.  At this
 2    time industry requested that we provide the resolution of
 3    comments document which provides the basis for the
 4    resolution of all our previous round one and round two
 5    comments.
 6              We provided that to the stakeholders and industry
 7    in March 2000, and we received the industry comments in May
 8    2000.  And we completed the evaluation of these comments in
 9    August and have incorporated all the comments into the
10    guide.  So the guide, as it stands today, incorporates all
11    the latest comments.
12              DR. KRESS:  What does that mean?
13              DR. CAREW:  Excuse me.  Go ahead.
14              DR. KRESS:  When you say incorporates all the
15    comments, does that mean you looked at them and decided
16    whether it is valid?
17              DR. CAREW:  Right.  And I will go into that in
18    detail.  I will discuss how we did that.
19              DR. KRESS:  Okay.
20              DR. CAREW:  And we intend, or we hope to intend,
21    or we expect to release the guide in early 2001.
22              Okay.  Let's see.  Now, I will get into the
23    resolution of comments.  Let's see.  We received comments
24    from the Nuclear Energy Institute, Penn State University,
25    and Bechtel Power, Bill Hopkins, and an organization called
.                                                                36
 1    Don't Waste Michigan.  This is a small organization -- I am
 2    not so sure it is small, but it is an organization that is
 3    focused on one specific reactor.
 4              MR. JONES:  I need to interject one thing here. 
 5    The Bechtel Power Corporation, those comments were received
 6    informally.  They were reviewed to the same degree and
 7    treated the same.  And, in fact, John mentioned that the
 8    figure that was incorporated due to those comments, you
 9    didn't get those in your package because they were submitted
10    informally.  I needed to point that out to you at this
11    point.  Excuse the interruption.
12              DR. CAREW:  Okay.  The comments concerned editing,
13    organization, methods and qualification.  The comments
14    included recommendations to both tighten and relax
15    requirements.  Okay.  And the resulting changes and
16    additions have been included in the latest version of the
17    guide.
18              I didn't want to go -- it is really unwieldy and
19    not necessary to go through all the comments, but I did go
20    to the effort of kind of classifying them, and to give you a
21    flavor of what they were like, which is probably pretty
22    meaningful.
23              Of all the comments, 50 percent were requirements
24    or requests to update or add references.  Actually, we had
25    one case where someone wanted to delete a reference.  We had
.                                                                37
 1    25 percent of the comments were to change the wording.  The
 2    wording wasn't quite right or whatever.  26 percent of the
 3    comments were they wanted us to clarify certain points.  It
 4    wasn't really clear, you know, there was some ambiguity what
 5    we were saying.
 6              CHAIRMAN SHACK:  Which comments are we talking
 7    about now, the earlier comments or the most recent comments?
 8              DR. CAREW:  These are the most -- yeah, these are
 9    the most recent comments, I guess.  We had several -- round
10    one and round two were first, and we resolved all those
11    comments, or we thought we had resolved those.  I think we
12    resolved those comments, but industry asked us for this
13    resolution of comments document, which had how we resolved
14    each comment and what the basis of the resolution was.  And
15    we provided that to industry and then they commented on that
16    document and also made new comments.
17              DR. SEALE:  That's what this is.
18              DR. CAREW:  And that is what this is.  This is the
19    last set of comments, which includes comments on the
20    resolution of the previous comments, plus the new comments.
21              DR. TSOULFANIDIS:  These were essentially received
22    in '99.
23              DR. CAREW:  These were all May '99 comments,
24    right.  And this is the sum, they went back and looked at
25    all the resolution of our previous comments and the new
.                                                                38
 1    comments, and made new comments which included that summary.
 2              CHAIRMAN SHACK:  These are May 2000 comments?
 3              DR. CAREW:  May 2000, right.  But they encompass,
 4    basically, since in March -- yeah, March 2000, we provided
 5    all the old comments in the resolution, and we said, okay,
 6    now give us all your new comments, any comments you have. 
 7    So these were all the outstanding comments, up to -- going
 8    back to day one.
 9              MR. JONES:  Let me interrupt you.  The meeting
10    that we had a year ago, September '99, we had made available
11    the NUREG-6115 and the Draft Guide, and we had a meeting
12    with industry.  And that was the first time they had seen it
13    for a while.  So we actually solicited comments, we asked
14    them to give us comments.  And at that meeting they asked
15    for the previous resolution of comments document, and so
16    everything John has been talking about is for comments
17    received this year.
18              DR. CAREW:  So, okay, and some of these comments
19    did address -- concern the earlier comments.  Okay.  And 26
20    percent were clarification where we had said things and they
21    wanted them to be clarified.  And then some of them asked
22    for additional guidance, we didn't give them enough.  They
23    wanted to be told exactly how to do things, more detail on
24    how to do things, and that was 9 percent.  And there were
25    some typographical errors.  And about 15, 14 percent were
.                                                                39
 1    actual technical issues.
 2              Okay.  Now, what I have done is I have gone
 3    through all those comments and picked out what -- well,
 4    before we do that, let me give you our approach to resolving
 5    the comments.  First of all, all the comments were
 6    thoroughly, absolutely thoroughly evaluated for possible
 7    inclusion.  We looked at every comment in detail.
 8              And we then held the comments up to these
 9    criteria.  We said for inclusion in the guide, we want this
10    comment to be consistent with the scope and the purpose of
11    the guide.  It has got to be a technically valid comment, it
12    has got to be technically valid.  It has got to be a
13    significant portion of the fluence determination, because we
14    have gone into a lot of detail already and it just -- it had
15    to be something significant.
16              It had to be consistent with presently accepted
17    methods.  If someone proposed something new, some new
18    technique and it hadn't been reviewed or wasn't accepted, it
19    wouldn't go in, because this is a guide that includes the
20    methods that are acceptable to the NRC staff.  So new,
21    unaccepted methods would not be included.  And the level of
22    detail should not be overly prescriptive.  There should be
23    some wiggle room and some flexibility for the analyst to
24    address his plan and treat items that may not be, you know,
25    included, foreseen in the guide.  So there has to be some
.                                                                40
 1    flexibility in the guide.
 2              Okay.  So, now the comments -- this was the
 3    response, the response and the evaluation of the comments
 4    were based on a team consensus.
 5              DR. TSOULFANIDIS:  Who was the team?
 6              DR. CAREW:  Well, the team actually evolved.  When
 7    we first started we had people, we had NIST, we had Jim
 8    Grundl and Dale McGary from NIST and a statistician from
 9    NIST, I forget his name.  Do you know him, Graham?  In any
10    case, we had a statistician from NIST.  Then we had, from
11    Oak Ridge we had Dick Merker, Frank Kam, and Igor Renic. 
12    And I then I guess that is it.
13              Now, more recently, this has taken place over
14    several years and some people have retired and the team has
15    basically, the last set of comments, the team has been
16    basically myself, Bill Jones and Lambros.
17              The resulting changes and additions to the guide
18    have been incorporated into the latest version of the guide.
19              Okay.  Let's see.  Okay.  All right.  Now, what I
20    have done is I have gone through all the comments, and I
21    picked out -- I didn't want to bore you with all the
22    comments, but I picked out what I thought were the most
23    significant and important comments.  Now, I would be very
24    willing to answer any questions on any of the comments we
25    haven't identified after I go through this.  But let me
.                                                                41
 1    first start by going through the comments I have selected
 2    and maybe I have got the ones you want to see.
 3              First of all, there were some general comments
 4    made by NEI and the first one was that the final version of
 5    the NUREG report on benchmark problems should be released. 
 6    Now, as Bill Jones just mentioned, that we have, at the
 7    September '99 meeting with industry, we released a draft
 8    copy of that report.  And there were comments on that report
 9    in this set of comments which we are addressing.  And I
10    might add, there was no major change suggested to the guide,
11    to the NUREG report.
12              But, in any case, we are working on this,
13    finalizing the guide -- finalizing this report.  Now, we
14    expect to release this report in early calendar 2001.
15              The second comment was that NEI suggested that we
16    have a round robin between industry contractors -- between
17    NRC contractors and industry participants, doing
18    calculations of a standard problem, the benchmark problem. 
19    Our response to that is that that is really outside the
20    scope of the guide.  The guide is intended to state what are
21    accepted methods and describe them.
22              In addition, I mean the guide provides a highly
23    detailed guidance on how to do calculations and measurements
24    that are accepted and that can be input to Appendix G, 10
25    CFR 50.61, and the application of these methods appears in
.                                                                42
 1    several of the references in the guide.  In addition, the
 2    NUREG report presents several more applications of the
 3    guide's methods.
 4              DR. KRESS:  It seems like, though, if you had such
 5    a round robin, that it would be a good indicator of the
 6    potential variability of the results that you would get from
 7    user variability, and that might be of interest to NRC as
 8    something -- you know, it doesn't have to be put into the
 9    guide, but it sounds like it would be a good thing to do.
10              DR. CAREW:  I am going to discuss that, I am going
11    to discuss the NUREG report.  And you will see, when we do
12    those calculations, that if someone takes that problem and
13    uses the methods in the guide, for example, the methods that
14    are used for Palisades and Beaver Valley, whatever, uses the
15    latest libraries and the current state of the art codes,
16    they would get results that are very, very -- and we have
17    done that.  You will see --
18              DR. KRESS:  I had in mind not using the benchmark
19    problem, but to take a reactor core, and say this is what
20    the core looks like.
21              DR. CAREW:  Yeah.
22              DR. KRESS:  And you go do it for this core and let
23    everybody use the same core.  But they have to prepare the
24    right input and prepare everything and see what variation in
25    results you get there.
.                                                                43
 1              DR. CAREW:  Right.  Well, now, let me just say
 2    this.  That is how the benchmark problem is intended to be
 3    used and the licensees, when they evaluate their methods are
 4    intended -- they are supposed to go out and take that NUREG
 5    problem and do exactly what you said, take that core that is
 6    well defined, calculate it and see how they do, and submit
 7    that into NRR.  And they are going to -- NRR will look at
 8    the results and say these look great and this will be the
 9    basis.  And I will discuss in this more detail.  But these
10    look great, and that will be a large part, or a part of
11    their licensee's approval of their methods.
12              To do the round robin, you would be doing exactly
13    that and everyone would be doing it together.  Well,
14    actually, now that I think about it, that may not be such a
15    good idea because it allows people to -- well, I guess it is
16    good for the industry and everything.
17              But just let me say this, that there is -- we have
18    just recently got a submittal where one of the licensees has
19    done that.  They have taken the problem and gone off and
20    calculated and submitted that as part of their submittal. 
21    So that type of thing, the activity is going on.  Maybe wait
22    till the end and we will discuss it.  After I go through the
23    benchmark problems, we can talk about this, you can bring it
24    up again.
25              MR. LOIS:  John.
.                                                                44
 1              DR. CAREW:  Okay.  Lambros, you were going to say
 2    something.
 3              MR. LOIS:  Yes.  To be more specific, yes, we did
 4    have and the other day, so the development of the
 5    methodology, we didn't have a round robin.  And that was
 6    from Pacific Northwest in the laboratory where we did, the
 7    NRC funded a sizable dosimetry and calculational,
 8    consequently, calculational project.
 9              At that time we did have a round robin
10    calculation.  In fact, we invited about 10 participants from
11    national laboratories and the industry, and I do recall that
12    we plotted the results and there was a factor of 3 top to
13    bottom variation.  And then we realized the enormity and the
14    significance of the project, but, really, we did not know we
15    could not reliably calculate fluences or even measure them
16    to that effect.
17              That project, which lasted for several years,
18    formed the background of what we have now.  So such
19    measurement and calculations have been part of the
20    historical development of this guide.
21              DR. CAREW:  And that experiment, that round robin
22    was for the pool critical assembly benchmark experiment.
23              Okay.  So these are the first two general comments
24    that we had.  And then I will go through some of the
25    specific comments.  The first comment is that the industry
.                                                                45
 1    went back and looked at how we resolved the earlier comments
 2    and they made the observation that some of the responses to
 3    those earlier comments provided valuable insight and should
 4    be included in the guide.  And went back and we agreed that
 5    some of these comments did actually provide valuable
 6    insights, but we also saw that some of them had already been
 7    -- we recognized that earlier had incorporated some of them
 8    already.
 9              There were others that we saw and said, yes, these
10    are good, and in the next version we have incorporated them. 
11    And then there were some that were outside the scope of the
12    guide and we didn't think it would be appropriate to put
13    them in.  So we went back and looked at that and
14    incorporated the ones that hadn't been incorporated already.
15              The next comment, there were several -- several
16    commenters identified ASTM standards.  For example, the ASTM
17    standard which characterizes the neutron exposure of iron in
18    terms of displacements per atom.  We incorporated that
19    standard.  There was a standard on testing and benchmarking,
20    we have incorporated that.  The selection of dosimetry cross
21    sections, and also there was one I left out here on the
22    least squares adjustment methodology, that standard has also
23    been incorporated.  So the ASTM standards that were
24    relevant, we have incorporated.
25              Let's see.  The next comment was when the Monte
.                                                                46
 1    Carlo -- in the Monte Carlo analysis, you have to set up
 2    kind of a bin to record, for each neutron, the contribution
 3    to the dosimeter response.  And the danger is the cross
 4    sections in these, for the dosimeters are thresholded --
 5    have threshold cross sections, and if the bin is too wide,
 6    you won't get an accurate, because the fluence may be large
 7    down here in a region where the dosimeter cross section is
 8    small, and you won't do the integration correctly unless you
 9    have an appropriate bin structure.
10              So that was pointed out and that was a good
11    comment, and we have incorporated that in doing the Monte
12    Carlo calculation, you must make sure that the bin structure
13    is fine enough to ensure an accurate integration over the
14    cross section.  So that has been included.
15              Another comment was that in the guide, as you
16    might expect, that the Monte Carlo calculation, the major
17    weakness in the Monte Carlo calculation is the statistics,
18    the variance, and especially in these types of calculation
19    where you have this strong attenuation, you have to make
20    sure that -- and, typically, you can't do that.  You can't
21    do this calculation with Monte Carlo unless somehow you have
22    a technique to increase -- reduce the variance, because if
23    you start the neutrons off, you only get 1 per 1,000 hits
24    the vessel and the statistics are very poor.  So you have to
25    some kind of a scheme which is going to reduce that
.                                                                47
 1    variance.  And there is variance schemes that people use.
 2              And in any case, because of this, we recognize
 3    that we should put in some kind of criteria for people so
 4    that when they get a fluence estimate, they will know that
 5    it is reliable.  So we put in five statistical criteria and
 6    the commenter noted that those criteria are really specific
 7    to MCNP.  And so what we did is we suggested that these be
 8    set as a minimum set.  And so we have changed the wording so
 9    that the criteria we have included there is a representative
10    set, it is not a definite set.  It is a representative set
11    and not a minimum set, so that is how we have corrected
12    that.
13              The next comment was -- this is a little bit
14    tricky.  When we do the benchmarking, we basically have
15    three estimates of what the uncertainty is.  We have an
16    analytic estimate of what the uncertainty is, an estimate
17    due to the plant dosimetry, and then we have an estimate
18    based on comparisons to the simulator like the PCA.  So
19    there is three values.  We have three independent estimates
20    of what the uncertainty is and the guide was initially
21    written so that we let the user assign a weighting to those
22    based on what he thinks is the best number, and they asked
23    us for more guidance.
24              Well, we recognize, first of all, that because the
25    weighting of the analytic estimates depends on the details
.                                                                48
 1    of the specific application, it is not really possible to
 2    specify a practical and generically valid prescription for
 3    determining the weights.  It is really -- it would be
 4    unwieldy to put in the guide.
 5              So what we have done is we have given an example,
 6    and we say that if you have a case where the source
 7    uncertainty is well known and the vessel diameter
 8    uncertainty is well known, the analytic uncertainty analysis
 9    will provide a good estimate of what the uncertainty would
10    be and you can increase the weighting, say, from .3 to .5. 
11    And then, in addition, if you have -- if the measurement
12    data, the dosimetry data is good, so, for example, you have
13    10 data points and they all have an accuracy of 5 percent,
14    that estimate should be reliable and you can increase the
15    weighting of that to, say, .3.  And, consequently, the
16    simulator weight would be .2.
17              So we have given an example that would indicate,
18    you know, what you have to consider.  You know, look at the
19    uncertainty analysis and ask yourself how good is that. 
20    Look at the dosimetry, if you have a lot of good
21    measurements that are really highly reliable, that is a good
22    estimate and maybe the simulator is not so good.
23              So rather than try to have some kind of a generic
24    prescription that would be unwieldy and wouldn't be
25    appropriate for the guide, we have put this example in.  I
.                                                                49
 1    think that is about as far as we can go.
 2              All right.  Anyway, any comments?
 3              [No response.]
 4              DR. CAREW:  The next comment was additional
 5    guidance on how the calculational benchmark should be used. 
 6    We initially had -- we are going to use it to determine, to
 7    actually determine the uncertainty, make a quantitative
 8    estimate of the uncertainty.  And the commenter suggests,
 9    why don't we make this into a go/no-go test?  Well, we
10    actually thought that was a pretty good idea and we have
11    changed the guide.  So the calculation of the NUREG
12    benchmark problems will be basically a go/no-go test.  You
13    do the calculations.  If they look at them, and they look
14    reasonable, you are getting close agreement, you get a go. 
15    If they don't, you have to go back and look at your methods
16    and revise -- either explain why you are getting large
17    differences or revise your methods.
18              And we expect, as you will see, we expect the
19    benchmark problems, since the problem is completely defined,
20    very little source uncertainties or geometry uncertainties,
21    you should get a very good, a very close agreement.  And
22    that is what we are -- okay.
23              The next comment was, while the guide provides
24    guidance on what agreement we should expect when you compare
25    integrated quantities -- integral quantities, there is no
.                                                                50
 1    guidance on when you compare group-wise quantities, what
 2    type of agreement you should get.  And that is true, we
 3    didn't give any guidance, and, therefore, we have removed
 4    that requirement.  We no longer require them to compare
 5    group-wise quantities.
 6              Another comment was we didn't define what a bias
 7    is or we didn't define bias or uncertainty in the guide. 
 8    And so we have added a reference for the term bias.
 9              The next comment was the level of detail required
10    for benchmark analysis wasn't sufficient or we needed more
11    data.  And what we did is -- and let me point out that the
12    benchmarks require a comparison to a simulator, which would
13    be the pool critical assembly experiment, for example, the
14    operating reactor dosimetry measurements or the NUREG
15    report.  I would just say first that we have already
16    included several examples of simulator experiments, the PCA
17    and the Venus.  And in response to this comment, we have
18    added some more references.  So we have beefed up this area
19    in response to this comment.
20              As far as the comparisons with dosimetry
21    measurements, we just note that the calculations of plant
22    dosimetry are required and are done routinely at all the
23    plants.  So these really -- there is plenty of information
24    out there on how to do these calculations of the dosimetry
25    measurements, and with the NUREG-6115, this includes
.                                                                51
 1    examples, several examples.  It includes the calculation and
 2    it includes how you do the calculation and the results.  So
 3    we think that with respect to 6115, the benchmark problems,
 4    there is plenty of information out there on how to do
 5    benchmark calculations.
 6              The next comment was that the simulator
 7    experiments do not provide sufficient detail to perform the
 8    benchmarks.  This is similar to the previous question.  As I
 9    said, we added references, additional references.
10              The next comments is that there are no results
11    available that use the DG-1053 method and I would say that
12    the NUREG-6115 report includes benchmarks results that have
13    been determined used the methods of the Reg. Guide.  There
14    is also several of the benchmark experiments out there that
15    are references, the H.B. Robinson experiment by Oak Ridge
16    uses the methods of the Reg. Guide.  And as Lambros
17    mentioned a few minutes ago, several of the licensees, the
18    Palisades and Beaver Valley calculations have been carried
19    out using the methods of the guide.
20              So the methods of the guide are -- references of
21    the application of the methods are fairly -- are available.
22              The next comment was that the benchmark problems
23    were done with the BUGLE-93 library and the DORT code. 
24    Well, the calculations were done -- those libraries are a
25    couple of years out of date.  They have a new library now,
.                                                                52
 1    BUGLE-96, and there is a new code called DOORS, which is
 2    actually a new version of DORT.  And the comment was, well,
 3    we should do the NUREG problems using these new libraries
 4    and the new code.
 5              And we agree that the codes, the nuclear data are
 6    being changed continuously, and we are presently reviewing
 7    this new library and this new code, and if we find that the
 8    differences have a significant effect on the application of
 9    this report and there is a need to revise NUREG-6115, that
10    will be considered.  And so we got in a time warp here, we
11    can't keep up with the changes.  But I really think, I am
12    fairly confident that the changes are not that significant
13    in those libraries and the code.
14              The next comment was additional guidance should be
15    used in qualifying calculations and what constitutes an
16    acceptable solution.  Well, what we say here, we have added
17    text to the guide that states basically that when you do the
18    benchmark problem, if the differences between the benchmark
19    problem calculation and the reference solution are
20    substantially larger than what would be expected based on
21    the difference in the methods approximation, the nuclear
22    data, the calculation would be considered unacceptable.
23              In this case, if we get very, very large
24    differences, when you do the benchmark problem, if you get
25    very large differences, what do you do?  Well, the
.                                                                53
 1    calculation should be reviewed and the differences
 2    explained.  And if the differences are due to an error in
 3    the calculation, the method should be revised.  So that is
 4    how we address that.
 5              CHAIRMAN SHACK:  What is a very large difference?
 6              DR. CAREW:  Well, when you see -- who has the
 7    question?  Okay.  When we get to the benchmark problems, you
 8    will see.  That is the next subject and you will see, we can
 9    discuss it at that point.
10              Okay.  The next comment was, in addition to the
11    solutions calculated with DORT and MCNP, there are other
12    codes out there that we should use, namely, this is -- DORT
13    is the Oak Ridge code, TWODANT is the Los Alamos code, and
14    they are both discrete ordinates codes.  This is an AEA
15    Monte Carlo code, MCBEND, and this is -- I believe, I think
16    that is what it is, yeah, it is AEA.  And this is the Los
17    Alamos Monte Carlo codes.
18              Now, all of these codes have been extensively --
19    they basically all use, you know, the Monte Carlo methods
20    use very similar methods and so do the discrete ordinates,
21    and they have all been well benchmarked and they have been
22    around for a long time, so the code to code variations will
23    be small.  And as a matter of fact, you will see when we
24    look at the benchmark problems comparison, they are very
25    small.  Even when we compare these two codes, the
.                                                                54
 1    differences are, you know, are very, very -- are small.
 2              So, we would expect, and I am very confident that
 3    if we use these other codes that the code to code
 4    variability would be much less than the uncertainties we are
 5    concerned about.  We are concerned about uncertainties of 10
 6    or 20 percent.  The code to code variability would probably
 7    be of the order of a few percent.  So that would be of
 8    interest, might be of some interest for code development or
 9    whatever, but looking at what we are looking at here, if
10    somebody, if a licensee submitted, for example, a code with
11    TWODANT, I don't think that, you know, it would be a major
12    concern here.  Okay.  That was that question.
13              Okay.  The next question was a request or a
14    suggestion that if the purpose of the benchmark problem is
15    to validate the implementation and the interfaces of the
16    code, why not just provide the licensee the electronic input
17    of the input data and the solution and they can just do it
18    all electronically.  But the point here is that the purpose
19    of the benchmark problem is not to just validate the
20    implementation of the code or the interfaces, it is also to
21    validate the methods approximations and your set-up, and all
22    your mesh and everything else.  And if we provided the
23    licensees both the input and the output, it would defeat
24    that purpose, it would not be really a valid test of their
25    methods.  So we had to -- we couldn't, we didn't make any
.                                                                55
 1    changes as a result of that comment.  I think that was the
 2    comment, right.  Yeah.
 3              Okay.  All right.  Another comment was that the
 4    guide requires that the measurement, the laboratory
 5    measurement methodology be validated every few years, or
 6    periodically, and the comment was that we should quantify
 7    this statement every few years.  Rather than saying every
 8    few years we should require that the laboratories validate
 9    their methodologies every two years or whatever.
10              And we have had -- it is amazing, we have had
11    discussions of this issue for a long time, from day one
12    basically.  In any case, we have talked to other
13    laboratories, we have talked to people that do the
14    measurements, and the consensus overwhelmingly has been to
15    leave the flexibility in there so that -- because there is a
16    substantial variation from laboratory to laboratory as to
17    the systems they use, the procedures, whatever, and we
18    should allow them some flexibility so that they can set
19    their own, you know, their own reasonable frequency of
20    validation.
21              And then the last comment we thought was
22    significant concerned the least squares approach.  I don't
23    know if you are familiar with this, but in this area, there
24    are ways of -- you do a calculation and you do measurements. 
25    And after you do the measurements, you may want to go back
.                                                                56
 1    and change your calculations.  And there is basically two
 2    methods of doing that.  You take your measurements, and you
 3    take your calculations, and you make ratios and you look at
 4    them to get a mean value and you determine that has a bias,
 5    and maybe if you really feel that that bias is really a
 6    solid number and reliable, and may help you, whatever, you
 7    would apply that as a multiplicative factor directly onto
 8    your calculation, and that is a direct deterministic method
 9    of doing that adjustment.
10              But, on the other hand, there are more
11    sophisticated techniques that form the same ratios,
12    measurements to calculation, but they take these into a set
13    of ratios and they look at them statistically, and they
14    build in different degrees of freedom into the calculations
15    and measurements, and they take these degrees of freedom and
16    they adjust them so they minimize the least squares
17    difference.
18              So, anyway, some licensees use one approach and
19    other licensees use this least squares adjustment approach. 
20    And some of the guidance in the guide I guess implied that
21    we were excluding the least squares approach.  So the
22    comment was that the guidance conflicts with the least
23    squares approach.  Well, we have gone back into the guide
24    and looked for any areas where the conflicts occurred and
25    eliminated them.  And this comment also suggested that we
.                                                                57
 1    reference the ASTM standard on least squares adjustment,
 2    which we have done.  So that is how we have addressed this
 3    comment.
 4              DR. TSOULFANIDIS:  John.
 5              DR. CAREW:  Yes.
 6              DR. TSOULFANIDIS:  Going back to 51, what if you
 7    say, instead of "every few years", "as deemed necessary",
 8    meaning if nothing new has developed in measurements and
 9    nothing has shown that measurements were done incorrectly,
10    there is no need to do anything.  But suppose a new
11    development comes in, a better detector, a better technique,
12    if you did the measurement today, you may have to revise it
13    a month from now.
14              DR. CAREW:  Yeah, I guess -- I hear what you are
15    saying.
16              DR. TSOULFANIDIS:  You may not have to do anything
17    in 10 years, but you may -- Lambros.
18              MR. LOIS:  This is Lambros Lois.  There is such a
19    provision in 50.61.  It says that any significant difference
20    in your calculations or measurements, you should report it.
21              DR. TSOULFANIDIS:  I thought this refers to
22    measurements only.  Every few years, revise the measurement
23    procedures or techniques.
24              MR. LOIS:  Yes, but what I am saying is that there
25    is an all inclusive provision in 50.61.
.                                                                58
 1              DR. TSOULFANIDIS:  Okay.
 2              CHAIRMAN SHACK:  I wanted to suggest that this
 3    seems to me a good place for a break since we have finished
 4    with the NEI comments.
 5              DR. SEALE:  Yeah.
 6              DR. CAREW:  Good idea.
 7              CHAIRMAN SHACK:  Just take a break for 15 minutes. 
 8    We will be back at 10:15.
 9              [Recess.]
10              CHAIRMAN SHACK:  I would like to resume our
11    discussion.
12              DR. CAREW:  Okay.  The next comment was that --
13    this was by Ali Haghighat from Penn State, was that it
14    wasn't clear that the Regulatory Guide methods, methodology
15    was applicable to the BWR because of the fact that there is
16    a substantial axial void distribution up the core axially,
17    and also because of the fuel isotopics.  And we have applied
18    the methodology to a BWR benchmark problem in NUREG-6115,
19    which I will discuss in a few minutes.  So you will see
20    that, in fact, we divide the core up into seven axial zones
21    to accommodate that axial void behavior, and we know that
22    this is adequate.
23              Let's see, the next comment from Ali was that the
24    verification of the variance reduction method used in the
25    fluence calculation is impractical, impossible.  Now, as I
.                                                                59
 1    mentioned before, because of the strong attenuation, when
 2    you do a Monte Carlo calculation, you have to somehow
 3    increase the statistics, pool your statistics, and what you
 4    do, one common technique is to split the neutron, so as the
 5    neutrons come in from region to region, that one neutron
 6    becomes five neutrons, becomes 10 neutrons, becomes 20
 7    neutrons.  So when you get to the vessel, instead of having
 8    that one neutron, you may have a hundred neutrons or a
 9    thousand neutrons, and that way, the variability is amongst
10    the 1,000 neutrons, so the statistical fluctuations are
11    much, much smaller.  Instead of having one stock, you have a
12    mutual fund which has a thousand stocks and the fluctuations
13    are much, much less.
14              Anyway, so, that is how you get around the
15    variance reduction problem.  In all these variance reduction
16    techniques, there is an approximation involved.  And, as you
17    might imagine, you don't get anything for nothing.  If you
18    reduce that variance, there is something you are cheating
19    somehow and there is an approximation.  And you must show
20    that that approximation is valid, there is no error in that. 
21    And the guide recognizes and says, if you use variance
22    reduction method, that is fine, but you must verify that you
23    are not introducing a bias or there is not an error coming
24    in.  So we require it to be validated, and this comment
25    says, well, it is impractical, impossible to validate it.
.                                                                60
 1              Well, when we ran the benchmark problems, we used
 2    a variance reduction technique.  And what we do is we run
 3    two problems, one problem with the variance reduction and
 4    one problem without, and show that the results -- you know,
 5    it is just one case, you do that once, and show the variance
 6    reduction works.  It is not valid -- it is valid, and then
 7    it is verified.
 8              So, in response to this comment that it is not
 9    possible or practical, we have used it.  We have actually
10    verified this and carried this process out in the NUREG
11    problems.
12              Yeah.  Go ahead.
13              DR. TSOULFANIDIS:  John, should you add to this
14    the fact that you calculate fluxes using the Monte Carlo
15    biasing techniques, et cetera, you use these fluxes to
16    calculate dose rates, and you compare these calculated dose
17    rates with the measured ones?
18              DR. CAREW:  Right.
19              MR. LOIS:  And that is another way to see how good
20    your Monte Carlo results are.
21              DR. CAREW:  Right.  But I think that when you
22    compare -- unfortunately, when you compare the measurement,
23    you have to have a very good measurement.  And, typically,
24    the measurements, if you are going to try to validate your
25    variance reduction technique, your splitting technique, for
.                                                                61
 1    example, by comparing that to a measurement, you always have
 2    the problem, you know, the measurement, you introduce the
 3    measurement error and your measurement error may only be
 4    good to 20 percent.  So you are really -- and, usually, when
 5    you run the Monte Carlo, you can run it down till you get
 6    statistics of like, you know, a few percent.
 7              So, presumably, you would like to have a
 8    comparison that would see an error of 5 percent, and the
 9    measurement errors usually are larger than that and you may
10    not be able to see -- you may not be able to get a credible
11    or reliable validation of the variance reduction method
12    against the measurement.  So we would say the cleanest way
13    to do it is take one calculation, use the variance
14    reduction, and to take the same calculation with the same
15    model, the same, you know, everything, everything exactly
16    the same except you have no variance reduction.  And this
17    way you can see exactly the difference in those two
18    calculations would be the effect of the variance reduction. 
19    And then it should be that both numbers agree to within the
20    statistics.
21              DR. TSOULFANIDIS:  Correct.  But --
22              DR. CAREW:  Okay.  I missed your point, go ahead.
23              DR. TSOULFANIDIS:  Not everybody will use the same
24    variance technique.  So if you did this for one specific
25    problem, what you propose there is fine.  But person B uses
.                                                                62
 1    different variance techniques and this is not validated.
 2              DR. CAREW:  Okay.  But the guide says the
 3    licensee, the analyst must validate his technique.
 4              DR. TSOULFANIDIS:  By doing this?
 5              DR. CAREW:  By doing this.  So if vendor X comes
 6    in and he wants to use a variance reduction technique,
 7    whatever it is, it is may be splitting, it may be some other
 8    technique, but whatever it is, that is an approximation and
 9    he must validate it.
10              DR. TSOULFANIDIS:  So for one case, they have to
11    do analog Monte Carlo?
12              DR. CAREW:  They must do a full Monte Carlo
13    without the variance reduction, right.  Some case that would
14    do that.  He has to pick out some case, maybe it is only a
15    1-D radial or a 1-D axial, it may be a simple calculation,
16    but he has got to show that his, whatever trick he is using
17    is valid.
18              It is just like using a discrete ordinate method,
19    if you use a group structure of 47 groups, and you have got
20    to show that that 47 group approximation is valid.  So we
21    consider the use of a variance reduction method, whatever it
22    is, that is an approximation and there are certain
23    assumptions built into that and they must be verified.  And
24    it is really important because these Monte Carlo
25    calculations and the variance reduction techniques are
.                                                                63
 1    complicated, they are subtle, you have to be very careful. 
 2    And it is hard, you know, in any case, we have this --
 3              DR. TSOULFANIDIS:  Absolutely.  They are called
 4    biasing techniques, but the trick is not to bias your
 5    result.
 6              DR. CAREW:  Not to bias it, right.
 7              DR. SEALE:  Thank God you have got the computers
 8    now that allow you to run these full Monte Carlos in a
 9    reasonable amount of time.
10              DR. CAREW:  Right.
11              DR. SEALE:  I mean the desktop machines do a
12    remarkable job on some of these.
13              MR. LOIS:  This is Lambros Lois again.  But what
14    Tsoulfanidis suggests would be ideal, would the best of all
15    worlds.  Unfortunately, the variation between -- on
16    dosimetry measurements, between reactor to reactor, are
17    quite significant, and even for the same capsule, we get
18    significant variations between dosimeter to dosimeter and it
19    would next to impossible to make sense out of that.  So,
20    therefore, you cannot use a measurement to, you know, verify
21    the uncertainty for that.
22              CHAIRMAN SHACK:  Just coming back to your comment
23    one on the BWRs.  Again, you know, I have shown an
24    approximation is valid for one case.  You know, how
25    home-free does that get me?
.                                                                64
 1              DR. CAREW:  Well, I mean if you look and ask
 2    yourself, you know, what is it about a BWR that would make
 3    these methods inapplicable, and the only question really is
 4    the void distribution.
 5              CHAIRMAN SHACK:  Does that mean every BWR is going
 6    to have to do, you know, five splits and then 10 splits and
 7    see if he gets a big difference?
 8              DR. CAREW:  No.  I mean with the seven, dividing
 9    up the seven regions, the error, the error in the void
10    fraction is less than the input void fraction.  In other
11    words, you calculate the void to be 30 percent, but, you
12    know, the core calculation of the void fraction is 30
13    percent, that is plus or minus a couple of percent.  Well,
14    when you break it up into seven nodes on the periphery, the
15    error in the void fraction is less than -- is of the order
16    of the error in the input void fraction.
17              In addition, if you are the on ex-vessel wall, you
18    are looking at, you know, you would be looking back at the
19    vessel, but you might be looking at three different zones,
20    okay, not just one zone.  And each one would have their own
21    error.  You might be high here, low here.  So it would
22    integrate out and the error would be much smaller.  So we
23    believe seven is more than adequate for a treatment of the
24    voids.
25              MR. HOPKINS:  Bill Hopkins with Bechtel, but I am
.                                                                65
 1    going to put on ANS-6 hat as the Chairman of the ANS-6
 2    standard, and give some more historical data.  In '85, EPRI
 3    funded SAIC to calculate what is a classic report on
 4    pressure vessel embrittlement with the state of the art
 5    then.  And they did both the PWR and the BWR case.  And they
 6    focused on this BWR void distribution as the key.  But at
 7    the same time they also had the opportunity to go down and
 8    instrument Browns Ferry.  That data is proprietary, but it
 9    exists.  But it did benchmark the fact that even in '85 the
10    methodology, which was the DOT at the time, with that -- I
11    guess that was the Saylor cross sections that they were
12    using, was sufficient to get you the responses.
13              It is something that is available through EPRI. 
14    But I always refer anybody wanting to try to calculate
15    things like this for the first time, since 6115 isn't out,
16    to go take a look at EPRI NP-152.
17              DR. CAREW:  Thanks, Bill.
18              MR. LOIS:  John, can I add one more comment? 
19    Since we are on the step, John, of this discussion, an
20    additional difficulty with BWRs is the presence of the pumps
21    and the risers.  Unfortunately, because it is not
22    cylindrical in nature, so it can be incorporated readily
23    into two-dimensional calculation, they introduce a
24    significant perturbation into the calculation and the
25    prediction what is beyond that.
.                                                                66
 1              What makes that even more significant is that --
 2    and rather unfortunate, is the GE practice to locate niobium
 3    and iron dosimeters right behind the pumps, with an enormous
 4    amount of iron.  Of course, the spectral distortions were
 5    tremendous.  And you get some measurements which most of the
 6    time you don't know what they mean anyway.  So those are
 7    difficulties which have to be faced for the BWRs.
 8              DR. CAREW:  Okay.  I have one more comment, and
 9    this was the comment from Bechtel Power, Bill Hopkins.  And
10    his comment was that he suggested the attached figure should
11    be included in the guide to clarify the dependence of the
12    fluence determination on fluence uncertainty.  And we
13    thought that was a good suggestion and we have incorporated
14    that figure as Figure 4 in the guide.
15              Okay.  Now, I would be willing to discuss any
16    other comments, any specific comments, if anybody has any
17    questions about any specific comments at this point.
18              [No response.]
19              DR. CAREW:  Okay.  All right.  Now, I will go on
20    to the pressure vessel fluence benchmark problem report, and
21    some comments were raised earlier and, hopefully, this will
22    address those comments.  The NUREG report includes a set of
23    pressure vessel fluence benchmark problems and solutions. 
24    The purpose of this report was to ensure the accurate
25    fluence predictions and quantify uncertainty, and to
.                                                                67
 1    standardize vessel fluence methods, and simply and
 2    streamline the licensing process.  That was the purpose.
 3              The way the benchmark problems would be applied is
 4    as follows, the methods are presented in great detail in the
 5    Regulatory Guide, and in the benchmark problem report, this
 6    provides the definitions, a complete definition and the
 7    reference solutions for these problems.  The licensee would
 8    calculate the benchmark problems and provide the comparisons
 9    to the reference solutions to the NRC.  And I would just
10    like to say at this point, that, in fact, a licensee has
11    just recently submitted the solutions to these problems to
12    the NRC for approval as part of their submittal for the
13    methods and provable.
14              And then, finally, the fluence methods would be
15    accepted based in part on the agreement with the reference
16    solutions.  Okay.  That is how the benchmark problem report
17    would be applied, intended to be applied.
18              Now, the problem definition for the problem, we
19    looked at four different types of cores.  We looked at three
20    PWR cores, a standard core and a low leakage fluence
21    reduction core, and a partial link shield assembly fluence
22    reduction core.  And we have also looked at a BWR core.
23              The problem definition includes a description of
24    the problem materials, geometry and pin-wise source.  For
25    each pin -- well, for each bundle, we provide the bundle
.                                                                68
 1    power, the exposure, the burnup of that bundle to get the
 2    plutonium buildup, and we also provide the actual pin-wise
 3    power for the peripheral assemblies.
 4              The problem is defined for typical operating
 5    geometry and materials, and the report includes a complete
 6    fluence analysis and execution of all the steps required for
 7    the RT PTS input.
 8              I am now going to describe some of the problems. 
 9    It is typical core-to-cavity dimensions, materials.  A
10    complete, detailed set of calculational input was provided. 
11    One of the things we were concerned about in defining these
12    problems, we wanted to make sure that the problem included
13    every single piece of data that was required, except maybe
14    the speed of light and a few other things.  But everything,
15    everything was there, and we made a great effort to do that.
16              We have dosimeters on the standard wall capsule,
17    on the vessel inner wall, and also in the cavity, and we
18    have accelerated capsules.  And we also provide the
19    dosimeter ENDF-VI cross sections.  So the user can use those
20    cross sections and the cross sections will divide out of the
21    comparisons.
22              Here is a picture of the actual problem.  The red
23    is the fuel, this is the core.  We have got the baffle, the
24    core barrel, the thermal shield.  We have a capsule on the
25    back of the inner wall of the thermal shield and a capsule
.                                                                69
 1    on the vessel inner wall.  We have a cavity capsule and a
 2    concrete shield.  This describes the interface right here
 3    and we have the coordinate system.  The coordinate system is
 4    important because when we give the pin-wise power in these
 5    peripheral assemblies, we need to know the orientation of
 6    the coordinate system.  That is the PWR problem.
 7              We also did a BWR, here is the BWR geometry. 
 8    Again, here is the core region.  The baffle, the shroud, the
 9    jet pumps and risers are included.  The pressure vessel wall
10    insulation and the concrete shield.  As I mentioned before,
11    we did, in the BWR, we have -- the axial treatment, a
12    definition of the core is more complicated than the PWR. 
13    There is seven axial zones.  And the steam separator and
14    dryer regions, the core plate.  Okay.
15              As I mentioned to you, the problem includes the
16    complete geometry, the inner inlet thickness, the vessel
17    clad thickness, all the geometry is included and all the
18    temperatures and materials.  And this problem has the
19    advantage of you try to go and calculate a measurement, you
20    know, a benchmark measurement, dosimetry in the capsule, you
21    have the problem that you don't -- this problem doesn't have
22    the uncertainty in the source.  The source is completely
23    specified.  The vessel diameter, the geometry is completely
24    specified.  The material compositions will be completely
25    specified.  Everything is fixed.  So the only thing should
.                                                                70
 1    be different if two people calculate this problem is the
 2    implementation of the codes, the interfaces, and the
 3    approximations used in modeling the core.  A representation
 4    of the jet pumps, how you represent those, all these
 5    different approximations that enter, they can be compared
 6    and validated very easily and cleanly in these comparisons.
 7              This is the compositions for each isotope, here is
 8    the very fuel, the very fissionable isotopes 235, 239 and
 9    240.  So the whole problem is completely specified.  And the
10    solutions are tabulated based on standard fluence
11    predictions.  The flux is given, the flux above 1 MeV, about
12    .1 MeV and DPA in the spectrum.  We have also included in
13    the report sensitivity calculations to various numerical
14    schemes, you know, the various -- we did the calculation, we
15    also provided a whole table of sensitivities.  The selection
16    of the quadrature S8 versus S16 and all the different
17    assumptions, the numerical assumptions that we made, we
18    provided sensitivities in the report.  It is done with S8
19    P3.  We have a synthesis, BULGE-93 cross sections, et
20    cetera.
21              DR. SEALE:  John, I have a quick question.
22              DR. CAREW:  Yeah, go ahead.  Yes.
23              DR. SEALE:  The R theta diagram you showed what, a
24    45 degree sector?
25              DR. CAREW:  Segment, right.
.                                                                71
 1              DR. SEALE:  Do you then assumption reflection
 2    around those boundaries?
 3              DR. CAREW:  The guide states that if the core has
 4    octant symmetry, you can do the calculation in octant
 5    symmetry.  And, typically, PWRs will have octant symmetry. 
 6    But if the symmetry is broken, you may need to run a quarter
 7    core calculation.
 8              DR. SEALE:  I see.  Okay.
 9              DR. CAREW:  Also, the layout of the jet pumps for
10    BWRs is not always --
11              DR. SEALE:  Scallop shield.
12              DR. CAREW:  It is not always octant symmetric. 
13    So, depending upon the symmetry.  Also, we say that if the
14    peak fluence is in one octant, they could look at that
15    octant.  Or if a particular capsule may be in one octant,
16    they may want to look at just that octant.
17              DR. SEALE:  Yes.  Yes.
18              DR. CAREW:  But, of course, these are very
19    expensive and time-consuming calculations, so you don't want
20    to set up more of a jump than you really need.  But you have
21    to make sure that the system you are looking at has the
22    proper symmetry, et cetera, to do that.
23              DR. SEALE:  Sure.
24              CHAIRMAN SHACK:  Just, in the nature, when you say
25    these time-consuming calculations, what are we talking about
.                                                                72
 1    on a modern computer?
 2              DR. CAREW:  Well, the discrete ordinate
 3    calculations are not that time-consuming, they may be five
 4    or 10 minutes, something like that maybe.  But the Monte
 5    Carlo are really costly.  They really take a lot of time. 
 6    And that is the reason why we didn't have those in the guide
 7    initially, we thought that they would be too expensive and
 8    people wouldn't run them.  And they might be an experimental
 9    tool, but not a design tool.  But apparently there actually
10    are -- they are creeping into the design tool, the design
11    scheme, and as computers improve, so that is why we
12    incorporate it.  And those are very, very expensive, I mean
13    they take a long time, days, weeks.
14              CHAIRMAN SHACK:  Oh, okay.  I mean we are talking
15    that kind of time.
16              DR. CAREW:  You are talking long, maybe even
17    months.
18              DR. SEALE:  There is one other comment here that I
19    think is worth noting, and that is that the ENDF/B-VI cross
20    sections mentioned here are different primarily in the way
21    in which the details of the iron cross sections in the
22    MeVish range, which is important here, are handled.  And
23    that work was actually financed by the NRC, as I recall,
24    back in the late '80s and early '90s, essentially as a
25    precursor to this evolution.  And think when we hear people
.                                                                73
 1    criticizing fundamental, so-called fundamental tasks and so
 2    forth, money spent on things that sound exotic sometimes,
 3    that it is instructive to recognize that here is some work
 4    which has immediate and serious impact on probably one of
 5    the most important questions facing the industry right now,
 6    namely, the credibility of the whole process of license
 7    extension.  And so it is important to recognize that
 8    fundamentals count, too.  This is a good example.
 9              DR. CAREW:  If I may say something, go one step
10    further, that work actually resulted in identifying a
11    substantial non-conservative in the fluence dose to the
12    vessels, so I agree.
13              MR. LOIS:  This is Lambros Lois again.  Dr. Seale,
14    thank you very much for recognizing that the need for this. 
15    I am the primary consumer of that information and the result
16    of that research.
17              Going back to the symmetry that you mentioned, 45
18    degree, unfortunately, when some of the plants that tried to
19    implement severe reduction in the leakage, and they tried to
20    protect non-octal symmetry axial welds, they have to destroy
21    the octal symmetry.  In fact, they have one reactor that
22    destroyed even the quarter symmetry and they are graphically
23    about a half symmetry.
24              In that case, they can still go back and work on a
25    45 degree angle -- I mean segment, provided that the one
.                                                                74
 1    that they work on is the one that contributes the most to
 2    the inside side of the pressure vessel.
 3              DR. TSOULFANIDIS:  I was going to say there is no
 4    true symmetry anyway.  The question is how much asymmetry
 5    you are willing to accept.
 6              MR. LOIS:  Yes.  Yes.  Yes.
 7              DR. SEALE:  Right.  It is a computational
 8    artifact.
 9              MR. LOIS:  Right.  Right.
10              DR. TSOULFANIDIS:  If you take the conservative
11    quarter, yes.
12              MR. LOIS:  Yes.
13              CHAIRMAN SHACK:  Just coming back to, you know,
14    your R theta meshes, I didn't notice any sensitivity studies
15    where you varied the mesh geometries.  I mean, you know, you
16    picked a mesh and you did the calculation.  Was that
17    presumably based on previous studies?
18              DR. CAREW:  Yeah, we have done, and you will see,
19    the same way we do the comparisons with the MCNP, exactly
20    how much that contributes.  But we have done -- I have
21    worked for Lambros over the years, and dating back -- well,
22    over the years, these mesh were not just created here, we
23    had a lot of experience, had done sensitivity calculations
24    of what mesh was adequate.  And, as a matter of fact, the
25    guide specifies what an adequate mesh is, and that is based
.                                                                75
 1    on previous -- the calculations that we have done that
 2    identifies the sensitivity to do that.  Actually, it is --
 3    what you have there, you have a Cartesian core and you have
 4    a polar coordinate system, an R theta coordinate system, and
 5    you have to map that peripheral geometry into little arcs. 
 6    And the arc has got to be pretty small.  Kind of like, if
 7    the boundary is like this, each arc has to cross it like
 8    this, like this, so you are going like this.
 9              And that mesh, it turns out if you take enough
10    mesh, and we do, and the industry does basically now, that
11    that is a pretty small effect.
12              CHAIRMAN SHACK:  What saves his bacon, too, is the
13    fact that there is a lot of attenuation in the core.  And so
14    if you are sitting here looking at the core, it is the piece
15    right in here that is closest to you and thinnest that
16    dominates the dose out here.  And this stuff gets kind of
17    hidden in the self-attenuation in the core that is in front
18    of it.
19              DR. CAREW:  And, also, like if you make an
20    approximation for this segment here, this segment will be
21    low and this will be high, but these are very small
22    segments, so at the inner wall, you are not just looking at
23    that one small segment, you are looking at a whole
24    integration of a summation of all those pieces.
25              So it gets to be, you know, it is about on the
.                                                                76
 1    order of a percent or two.  But, of course, mesh will be 2
 2    percent, a fine mesh would be 1 percent, something of that
 3    order.
 4              So, okay, let's see.  The next slide is a slide
 5    showing the typical results.  Here we have the fluence, the
 6    significant figures.  This is a function of azimuth angle as
 7    you go around the vessel in a wall, and this is at the inner
 8    wall, quarter T, half T, three-quarter T and full thickness,
 9    and these allow a detailed comparison of the results.
10              Okay.  Now, the next step was to discuss the Monte
11    Carlo calculations, and this was, as we mentioned, this was
12    a round two comment, which we have added as a result of the
13    round two comment.  And so what we have done is we have gone
14    back, and after having done discrete ordinate calculations,
15    we have gone back to those problems and redone them with
16    Monte Carlo.  As we know, Monte Carlo is an entirely
17    different methodology.  The geometry is represented by
18    surfaces, each surface as far as the problem is explicitly
19    represented in the problem.
20              We looked at a standard core, a partial link
21    shield assembly core and BWR core, I though these were a
22    fairly complete set.  The Monte Carlo includes exact 3D
23    geometry.  We have a pin-wise -- the source is defined for
24    each rod, it goes in explicitly, individually.  And we have
25    the same basic cross sections as the DORT calculation.
.                                                                77
 1              And I might add at this point we could have gone
 2    to BUGLE-96.  BUGLE-96 had been on the street at this time,
 3    but we thought consistency is more important than the latest
 4    set of cross sections.  We want to have the MCNP and the
 5    DORT, everything exactly the same and compare apples and
 6    apples.
 7              So, let's see, and I might just say that we have
 8    used a region-wise importance variance reduction, or
 9    splitting, so the neutron is split.  It is kind of
10    interesting, each neutron that emerges from the core, by the
11    time it hits the vessel, is a thousand neutrons, basically,
12    to accommodate the factor a thousand attenuation.
13              We edited the flux above 1 MeV.  Of course, with
14    the Monte Carlo it cost.  The lower the neutrons go, the
15    lower you go, the much more expensive, and these
16    calculations were very, you know, they are very, very
17    time-consuming even on today's computers, especially if you
18    make a mistake and have to redo it.
19              CHAIRMAN SHACK:  This neutron splitting, is this
20    what I think of as stratified sampling, that I am really
21    taking samples from the neutron spectra that are the ones
22    that get to the wall?
23              DR. CAREW:  No, it is not the same.
24              CHAIRMAN SHACK:  It is not the same thing.
25              DR. CAREW:  The same is that you have a neutron
.                                                                78
 1    that comes into one region and there is a boundary here, and
 2    as it enters that region, you say I am going to split that
 3    to four neutrons, say, for example.  And you split it, it is
 4    now four neutrons.  But what you do, and it is the same
 5    direction and orientation, whatever energy, but you now, to
 6    make it a fair game, you have got to reduce the weight in
 7    between those neutrons.  If the weight of that initial
 8    neutron would start out to be 1, say, for example, now it is
 9    .73, and it is now four neutrons, you have got a sample, so
10    the weights of these four neutrons carries the same amount
11    of weight as the original one.
12              But the advantage is that when that neutron gets
13    to the vessel inner wall, it is a thousand neutrons or, you
14    know, 920 or whatever it is, and, as a result, the
15    variability in your results, if one of those neutrons
16    underwent a scattering in some region, it would only have a
17    small -- or if one of those neutrons went straight through
18    and hit the vessel directly, the vessel, the edit wouldn't
19    jump up because it carries a small weight.  Whereas, if it
20    was one neutron and it went straight through, the tally on
21    that edit would go way up, and the variance, when you took
22    the mean value of that location, the mean value would be a
23    certain number of neutrons, plus or minus 500 percent, or
24    100 percent, whatever.  So that is how it works, it is not
25    the same as stratified sampling.
.                                                                79
 1              Okay.  So we have done these calculations.  And as
 2    I mentioned, as we cut the problem off, you know, at 1 MeV
 3    because they are very expensive, and that was sufficient for
 4    the comparison.  And interesting enough, we find that the
 5    agreement, after we ran enough histories, that the agreement
 6    was within 5 percent, roughly 5 percent.  We were very happy
 7    with this result in view of the differences in all the
 8    methodologies.  This 5 percent is due to the MCNP statistics
 9    which were about 4-1/2 percent, the DORT geometry
10    representing the Cartesian geometry with this planar or
11    radial coordinate system, polar coordinate system.
12              The DORT numerics, the fact that we have only a
13    certain number, 50 angles, 48 angles to cover the sphere. 
14    And the fact that we are doing a synthesis.  We do a radial
15    calculation and an axial calculation.  There is always a
16    concern, you know, we can't do 3D, we are doing a synthesis
17    calculation, how do you know that the radial and axial is
18    separable?  There is that issue.  And this put that to bed.
19              So, anyway, now let me show you the results.
20              DR. TSOULFANIDIS:  John.
21              DR. CAREW:  Yes.
22              DR. TSOULFANIDIS:  So the statistical
23    uncertainties of the MCNP were less than 4.5?
24              DR. CAREW:  Yeah, I think there were about 4 -- I
25    think the statistics on the MCNP were maybe 4 percent,
.                                                                80
 1    something of that order.
 2              DR. TSOULFANIDIS:  4 percent.  So the 5 percent is
 3    the difference just between the numbers obtained by MCNP and
 4    they don't --
 5              DR. CAREW:  Right.  And I have figures, you will
 6    see.
 7              DR. TSOULFANIDIS:  Okay.
 8              DR. CAREW:  So it will be 5 percent, it is very
 9    good.
10              All right.  The first case I have a comparison for
11    the PWR, pressurized water reactor, and as a function of
12    azimuth.  As a function the angle, the flux above 1 MeV,
13    MCNP and DORT, and you can see they track very well, they
14    are close.
15              And the next calculation is a partial link shield
16    assembly core, and I will just show you this core is a
17    really tough test.  And the core, the red is the fuel, but
18    at the bottom 3-1/2 feet of the core, there is a weld
19    simulated to be right over here, and the contribution to
20    this weld comes from this 3-1/2 feet of fuel.  And they cut
21    out -- we have stainless steel rods in here.  So we did this
22    calculation both -- and this is a severe test of a synthesis
23    also, trying to do a calculation like this.
24              So, in any case, here are the results.  Let me
25    find that.  This is the MCNP and the DORT calculation, and,
.                                                                81
 1    again, they agree very well.
 2              DR. SEALE:  That sort of confirms it is the outer
 3    skin closest that dominates the dose at a particular point.
 4              DR. CAREW:  Right.  Yeah, we have done special
 5    cases where we have loaded in just the bottom outside row
 6    and we find that 85 percent of the signal is coming from --
 7              CHAIRMAN SHACK:  Now, would I find somewhat less
 8    agreement if I moved up axially till I, you know, say I hit
 9    that discontinuity?  This is at the weld, is where you are
10    really interested?
11              DR. CAREW:  Right.  I think probably -- I don't
12    know.  I don't know.  Up here, you probably had very good
13    agreement and it would degenerate somewhat as you get down
14    here, I guess.  But let's see.  I don't know.
15              Actually, we do two calculations, we do a planar
16    calculation and a planar calculation here.  So, we are doing
17    two calculations.  I don't know, I really can't speculate if
18    it would get better.  We haven't done that calculation.
19              Okay.  That is the PWR, and now this is the BWR. 
20    This is the -- yeah, okay.  This is the result at the flux
21    above 1 MeV at the downcomer and, actually, if you go back,
22    if you remember, this peak here, which is a substantial
23    peak, and this peak is due to the fact that the core -- this
24    is the closest distance between the core and the vessel, and
25    that is why there is a peak here.  But, again, you can see
.                                                                82
 1    the results were really -- I thought these results were
 2    excellent.
 3              DR. SEALE:  Where were the jet pumps in there?
 4              DR. CAREW:  Yeah, good question.  The jet pumps
 5    are right over here, right here, and then there are some jet
 6    pumps over here.  Let me think.  But there is also, there is
 7    a location of close approach between the core and the vessel
 8    here.  So this peak and this peak, and this peak here are
 9    due to the proximity to the core, distance to the core.  I
10    looked at that because I was wondering if I could see the
11    jet pumps on this.
12              CHAIRMAN SHACK:  Yeah, I mean you see less wiggle
13    than you might expect from the geometry, I mean because
14    there is an awful lot of jet pumps and risers, and yet you
15    only see sort of, you know, two dips.
16              DR. CAREW:  Right.  Yeah, I didn't see -- I
17    couldn't see the jet pumps on this, I really couldn't.  But
18    I know the jet pumps are worth about 13 percent, I know from
19    previous calculations.  So it is in here, but you don't see
20    any abrupt, and that is probably because these are fast
21    neutrons and I don't really see, you know, see the detail.
22              Actually, attenuation properties in steel and
23    water are not that much different.  If you go back to that
24    figure on the beginning of the presentation, you will see
25    that the fluence drops off rapidly in the water and it drops
.                                                                83
 1    off fairly rapid in the steel, too, except at the
 2    interfaces, the spectral change that you get to see this
 3    wiggle.
 4              DR. TSOULFANIDIS:  What I find interesting is the
 5    ratio of the maximum to the minimum in the BWR is a factor
 6    of 5 almost, and in PWR is a factor of 2.
 7              DR. CAREW:  Right.  And that is all dictated by
 8    the core peripheral geometry.  We looked at a lot of these
 9    cores and as part of Shah Malik's work, we have been looking
10    at a whole series of reactors and there we can see the
11    effect of the core geometry.  And it is interesting the
12    dominant effect is the core geometry.  You get some plants,
13    if I recall, Oconee and Calvert Cliffs -- I think Oconee and
14    Calvert Cliffs didn't have that much azimuthal variation,
15    where Robinson had some severe, and it is all dictated by
16    the distance between the core and the vessel inner wall,
17    that determines the shape.
18              So we felt that this agreement is very good, and
19    we feel that if somebody else goes and tries to calculate
20    these problems, and they are going to be using the exact
21    same problem, geometry, materials, source, exactly the same,
22    where other comparisons, there is all kinds of variability. 
23    As you pointed out earlier, than when you construct a
24    source, you have to go over cycles and go through all this
25    calculation.  That is all factored out of these comparisons. 
.                                                                84
 1    So the only things that should affect these comparisons are
 2    two things, basically, the numerics, the numerical
 3    procedures in DORT, so long as you use DORT, for example, or
 4    MCNP.  And those, the effect of the numerical procedures,
 5    you can see should be small.  You have a synthesis here, and
 6    the selection of the mesh and everything else.  The effect
 7    of the numerical procedure should be small, and if you use
 8    -- these are ENDF-VI cross sections, if you use ENDF-VI
 9    cross sections, even if is a BUGLE-96, I would anticipate
10    even there, there is not going to be that much difference.
11              On the other hand, if you use BUGLE -- if you use
12    ENDF-V or earlier cross sections, you would see a large
13    variation.  So if someone did a calculation of this
14    benchmark problem with an earlier version of the cross
15    sections, they would get a large difference and they would
16    become aware that that difference is due to the cross
17    sections.
18              DR. TSOULFANIDIS:  Just a comment.  In MCNP
19    calculations, you can assign error bars.
20              DR. SEALE:  Yes.
21              DR. TSOULFANIDIS:  Without difficulty.  It is much
22    more difficult to assign error bars to the numerical
23    deterministic calculations, but we know they are there.
24              DR. SEALE:  You know, this is really interesting,
25    it is almost like two guys getting lost in the woods 30
.                                                                85
 1    years ago, and one guy goes down a path where he does
 2    continuous slowing down, but he is limited on sample sizes
 3    he can use because of the number of neutrons he can use in
 4    the Monte Carlo.  Well, the other guy does the discrete
 5    ordinate transport theory, but he has to use groups, and he
 6    is also limited because he doesn't -- he can't, in his
 7    discrete ordinates, represent the geometry with the kind of
 8    absolute faith that you can put into a Monte Carlo.
 9              And suddenly these guys come out of the woods on
10    the other end, and they got to the same place.  And what it
11    really indicates is a remarkable amount of very good
12    judgment in which those compromises that were inherent to
13    the two sets of methods were made in the evolution of those
14    methods, so that, indeed, they turned out to be the right
15    kinds of compromises when you got enough computing power to
16    really hit the problem hard enough to get an answer.
17              There are not too many calculations where you have
18    the effort put into them to demonstrate this kind of
19    agreement where you have one or the other.  So this has a
20    lot more value than just in these particular calculations.
21              DR. CAREW:  I agree with you, and I think it
22    really confirms the two people ended up in the same place. 
23    I don't know who is bleeding more, but -- maybe it is the
24    discrete ordinates guy.  But there is a question who is
25    smarter now.
.                                                                86
 1              DR. SEALE:  Both of them are smart.
 2              DR. CAREW:  Yes.  Okay.  There is one more
 3    transparency.  And I guess this is really -- I have to
 4    agree, really, it is kind of amazing that we could do this
 5    calculation.  And this calculation, in a BWR, you probably
 6    recall that you have a BWR zirc alloy fuel channel with fuel
 7    roads inside and you a void fraction that varies from like 0
 8    to 60 to 70 percent at the top of the core.  And then you
 9    have, around that channel, you have a solid water region, a
10    bypass region.  And the question would be, do the neutrons
11    care whether you take that -- when you do the calculation,
12    do you mix the whole thing together and make it one
13    composition, homogenize it, or does it care, do we have to
14    go and represent those two regions separately, explicitly,
15    as two different regions?  Because you are pushing,
16    basically, what you are doing is you are pushing water back
17    and forward.  The neutrons in the center of that assembly,
18    some of those neutrons, if you push the water to the front,
19    in the back into the bypass region, they are going to be
20    seeing less water or more water, and you are wondering the
21    importance of the neutrons and does it divide out or is it
22    important.
23              So what we did is we did two calculations.  We did
24    one calculation, which was our first calculation, where we
25    homogenized everything, and the second calculation we
.                                                                87
 1    divided up and put an explicit water bypass region and the
 2    void region inside.  And we did the calculations, in fact,
 3    our first calculation wasn't in such good agreement, we
 4    found a problem in the Monte Carlo.  But, anyway, we looked
 5    closer and the calculations actually, I looked at these and
 6    I was kind of hoping I just could see the effect, but I
 7    can't even see the effect, I really can't.  With all
 8    honesty, I really can't.  Because I understand physically
 9    what should happen, but I can't see it.  But this confirms
10    that approximation, that you could do this in a homogenized
11    way.
12              But, anyway, that is the end of my presentation. 
13    Are there any questions?  I guess I will let Bill do the
14    next presentation.  I will just leave my stuff here.
15              MR. JONES:  As I said, John has been involved in
16    this effort all the time that it has been going on, and I
17    think people are already getting a benefit from what has
18    been done.  There is already benefit, people are already
19    using the NUREG and, as Lambros said, people are using the
20    Draft Guide, so there is already benefit to that.
21              And I think the level of detail that John has gone
22    into and that this effort has gone into, I think you have
23    seen an indication of that.  On my summary, which is the
24    last sheet in your small package, John has talked about
25    this, the level of detail in the guide, and he has just
.                                                                88
 1    talked about the benchmark and the benefits that has and
 2    what it contributes.
 3              When we talked about the history, we talked about
 4    it has been around since '93.  We have had several public
 5    meetings, several rounds of comments.  We have tried to
 6    really -- we have really been interested, everybody involved
 7    in this has been interested in making it better, and we have
 8    really tried to incorporate comments which we thought really
 9    helped the guide and improved it.
10              At this point the staff believes the guide is
11    ready.  The plan is to have the ACRS full committee on
12    December 7th and we would like to publish the guide in early
13    calendar 2001.  We plant to publish the NUREG at the same
14    time.  That is really all I wanted to say in summary.
15              If there are any general questions or questions
16    that we can answer?  And, again, I want to thank you for
17    your time.
18              CHAIRMAN SHACK:  How fast do you think this is
19    going to make a change?  You know, if the guy is calculating
20    away, is he going to suddenly switch?  When is he going to
21    get the heat to lean on him here?
22              MR. LOIS:  This is Lambros Lois again.  No, we
23    don't expect any step function to arise because of the
24    publication of the guide.  As we pointed out earlier, all
25    the licensees are aware of our requirements and they do
.                                                                89
 1    account for them.  As an example, we recently received a
 2    methodology and it practically has all of the -- it shows
 3    cognizance or awareness of all of the contents of the guide. 
 4    So all we need to do, actually, what we are going to do now
 5    is to make it official, so to speak.
 6              CHAIRMAN SHACK:  We have sort of focused on what
 7    an impact might be on PTS.  How about other kinds of
 8    embrittlement, would it have a bigger influence?
 9              MR. LOIS:  Absolutely.  We had problems where we
10    couldn't haven't gotten in the past help from the guide. 
11    The shroud problem, you are aware of that.  Internals, core
12    internals, pressure temperature curves, which are quite
13    important, and so forth.  So the guide will help quite a bit
14    of application in a variety of areas.
15              CHAIRMAN SHACK:  Thank you very much, Mr. Jones.
16              Any further questions?
17              DR. TSOULFANIDIS:  We all know it would be nice to
18    have in-vessel, ex-vessel measurements to compare the
19    calculations with, because then you can bracket the result. 
20    And not all plants have ex-vessel measurements.  Not all
21    plants have ex-vessel measurements.
22              MR. LOIS:  That is correct.  However, in the
23    context of Appendix H, we did give some guidance in the past
24    that ex-vessel measurements would be acceptable as a
25    substitute to satisfy the requirements for Appendix H.  And
.                                                                90
 1    those reactors that they really have an interest in pressure
 2    vessel, or have a problem, I should say, or close, they all
 3    have both, inside and outside measurements, because of their
 4    effort that they try to define the problem they had more
 5    closely, so the readily available thing to do is to go and
 6    get a copy of the measurements, and they have done that.
 7              CHAIRMAN SHACK:  I think we have a request from
 8    Mr. Warsham of Framatome to make some comments.
 9              MR. WARSHAM:  I am Tucker Warsham, I am
10    representing Framatome Technologies, as well as the BWR
11    Owners.
12              This guide really started to impact us in 1992,
13    even though it officially wasn't out at that time.  We
14    brought the staff a review from a $2 million program on
15    cavity dosimetry and we just completed it.  And the staff
16    informed us that the program was not sufficient without a
17    reactor vessel calculational approach and a comparable
18    calculational uncertainty methodology.
19              And, so, as we know, in 1993, February, there was
20    the industry meeting, and then in September, the first Draft
21    Regulatory Guide 1025.  As far as we are concerned, we
22    looked at what the fundamentals of the guide were.  And the
23    basic premise is that the current technology that the
24    industry was using, which really included what we would call
25    this unfolding or this adjustment technique to assess a
.                                                                91
 1    measured fluence at dosimetry locations, and the fact that
 2    we then would proceed to extrapolate to the vessel the basic
 3    premise of the Draft Reg. Guide.  Of course, this was not a
 4    consistent technology and particularly not consistent with
 5    respect to the way the PTS uncertainty analysis had been
 6    done at Oak Ridge, which was the fundamentals for the safety
 7    analysis of each type of B&W combustion and Westinghouse
 8    core.
 9              So, in order to be consistent with the
10    embrittlement, and particularly the PTS safety, again, what
11    fundamentally the guide was saying, that if you were
12    analyzing the vessel, that you should have a calculational
13    uncertainty and something that could be used to define
14    accuracy and precision of what the fluences would be at the
15    vessel.
16              Okay.  For several years, Framatome worked on the
17    fundamentals of what the PTS safety analysis had actually
18    been, the probabilistic work.  We looked at the correlations
19    that are the heart of Regulatory Guide 1.99, Rev. 2, and our
20    objection was, of course, to prove that the staff was
21    erroneous in their assessment that previous technology was
22    not adequate.
23              Unfortunately, after spending a couple of years
24    doing this assessment, we found that the staff was actually
25    correct in their assessment.  The old fluence technology was
.                                                                92
 1    not consistent with the way PTS probabilistic analysis was
 2    doing, the uncertainties could not be shown to be
 3    consistent, and, therefore, additional work would be
 4    required.
 5              Okay.  The one thing that we found was the staff
 6    estimates in the Draft Reg. Guide what the cost would be to
 7    the industry.  We found that this estimate was actually very
 8    much too low.  Even John may have estimated, helped estimate
 9    that, as you can hear, if you are running a Monte Carlo code
10    for a week or a month, and you are actually paying for a
11    computer to do that, it is quite a bit more costly than what
12    was originally put out in the guide.
13              What we would like to conclude by saying is, in
14    consideration of these costs, what has the industry gained? 
15    And in truth, right now, if you say, what tangible benefits
16    have we gained, we haven't gained any tangible benefits.  We
17    have gained benefits in terms of the plants inherently being
18    more safe, but there is nothing we can report to and say,
19    yes, we can extend the life of a plant one year or two
20    years, or we can do something.
21              What we would like to suggest to the staff and to
22    the ACRS, that there are now tangible benefits that should
23    be considered.  The first is we have been hammering on the
24    uncertainties, as John showed.  It is amazing, two totally
25    different analyses, although done by his hand, so, I don't
.                                                                93
 1    know, maybe there is some question, but two totally
 2    different analyses turned out to be right on top of each
 3    other, meaning that there is quite a bit of reduction in
 4    certainty from fundamental physics.
 5              Okay.  If there is such a reduction, one question
 6    that Lambros always has is, how are the material people
 7    interfacing with him, which is one of the issues of the
 8    whole draft guide to begin with.  But if we have become more
 9    accurate, the inherent uncertainty in the PTS value in terms
10    of delta temperature and in the pressure temperature curves
11    for reactors, that uncertainty should be now considered to
12    be reduced.  And I am not saying that we know how, but I am
13    suggesting that it is time for the fluence part of the
14    Regulatory Commission and the materials part to get together
15    and think about what can the industry gain and can we gain
16    some margin reduction in the materials side because the
17    fluence is now much more accurate?
18              And we also would like the ACRS and the staff to
19    consider that now that we are predominantly doing
20    calculations, 10 CFR 50, Appendix H, references an ASTM
21    standard, I think it is 185, which requires considerable
22    dosimetry ever time you are evaluating a reactor.
23              Now, if you conform to the guide, do you continue
24    to need this much dosimetry, or is it now possible perhaps
25    to reduce the total number of dosimeters down somewhat,
.                                                                94
 1    maybe cut them in half?
 2              There are two things that we would like to
 3    consider.  So, basically, we have finished.  If there are
 4    any questions you all have from those comments?
 5              No, you know, Dr. Lois, I don't want any questions
 6    from you.
 7              [Laughter.]
 8              CHAIRMAN SHACK:  There is a certain amount of
 9    discussion in the NEI comments, you know, that the Draft
10    Guide still doesn't provide enough guidance, that it is
11    going to be difficult to use.  Have you looked at it and
12    tried to use it?  Do you have any feeling for whether you
13    know what kind of rock you are supposed to bring?
14              MR. WARSHAM:  From Framatome's perspective, we
15    finished, we submitted a topical, we have argued with the
16    staff, and the staff has accepted.  So we feel very
17    comfortable with the guide because we have gone through all
18    the steps.
19              Before we went through all the steps, we had the
20    same question as many others had associated with NEI, is
21    there too much flexibility for the staff to say wrong rock
22    after hundreds of thousands or millions of dollars had been
23    spent?  Go ahead.
24              DR. TSOULFANIDIS:  When you say, should we reduce
25    the number of dosimeters, what exactly do you mean?  If we
.                                                                95
 1    used 10 thresholds before, they use five now?
 2              MR. WARSHAM:  That is exactly what I am saying. 
 3    Particularly in these two year cycles, what value is a
 4    nickel dosimeter that has a half-life of 87 days?  Could we
 5    drop back, stick with some coppers and some uraniums or
 6    neptuniums, cut out some of the iron and nickel?  Exactly. 
 7    Rather than having four or five different types and three or
 8    four of each of those types, could we shut it down to a
 9    couple of types?
10              And before when we were highly relying on the
11    measurements and using the measurements for this benchmark,
12    I think the answer would have been no, but today, if you
13    have been approved by the guide, if you are fundamentally
14    now working on analyzing what the calculational technology,
15    then can't you just use the measurements to continue to
16    check that each time you do it, that you are okay, but you
17    don't need quite so many measurements?
18              MR. LOIS:  Can I answer that?  I am not really --
19    the problem, I would rather define the problem than answer
20    it.  The question is legal as well as it is practical.  In
21    the practical sense, you are right, we now have sufficient
22    information, have sufficiently developed the technology that
23    we can do the same thing with fewer dosimeters.
24              However, the provisions of Appendix H have to be
25    satisfied, a dosimeter has to be there.  Now, that is a
.                                                                96
 1    legal problem.  On the other hand, the slowness with which
 2    the agency moves in changing the provisions of Appendix H,
 3    and Appendix G, for that matter, may have some wisdom in it,
 4    and that is, well, what if things.
 5              A long time ago we thought the cross sections, we
 6    knew everything about it within 1 or 2 percent. 
 7    Unfortunately, iron, as you know well, changed, and there
 8    are still some far flung questions out there remaining, kind
 9    of wandering around, such as their rate effect, some other
10    things which we do not know the response to.  And although
11    for a time being it seems as if we are doing a little bit
12    more to be certain what is going to happen in the future,
13    particularly with life extension, we would rather do a
14    little bit more rather than a little bit less, just in the
15    case in the future something else shows up.
16              So, I agree with you that right now it seems as if
17    with the improvement in technologies, the need is for less
18    dosimetry.  If we keep it there, keep it up, we may be
19    better off in the future.
20              MR. WARSHAM:  We would be happy to compromise and
21    have the material people just take a couple of degrees off
22    the delta T and we will kick the dosimetry in the core.
23              MR. LOIS:  I don't speak for them, but, however,
24    the methodologies that are right now in the works may
25    actually effectively do that, what you are asking, namely,
.                                                                97
 1    the introduction of probabilistic methods into the
 2    evaluation of the margin.
 3              CHAIRMAN SHACK:  Any other comments?
 4              [No response.]
 5              CHAIRMAN SHACK:  I think we can bring the meeting
 6    to a close then.  Are there any comments from the other
 7    committee members?
 8              DR. KRESS:  Are we going to have a letter on this?
 9              CHAIRMAN SHACK:  Yeah, we are going to have a
10    letter on this.
11              DR. KRESS:  Have you decided on what presentation
12    you are going to have at the full meeting?
13              CHAIRMAN SHACK:  Yes.
14              DR. TSOULFANIDIS:  There was a comment in the
15    beginning of the meeting about 1.99 and an approximate
16    attenuation factor that is being used now.  I assume if this
17    is approved, then there is no need to use the approximate
18    factor?
19              MR. JONES:  I have a slide.  This is an
20    indication, you can see the red curve in the current
21    attenuation factor in 1.99, Rev. 2.  And this is part --
22    John mentioned that we have looked at several vessels as
23    part of the probabilistic PTS work.  Okay.  So this is a
24    comparison with a DORT calculation and the attenuation
25    factor for a vessel.  And they are very close for the first
.                                                                98
 1    couple of inches, and the attenuation is conservative
 2    relative to the calculation.  Is that the answer?
 3              DR. TSOULFANIDIS:  So you will keep using the
 4    conservative approach?
 5              MR. JONES:  Well, Shah is the PM for the
 6    probabilistic fraction mechanics work and he can address
 7    that issue.
 8              DR. MALIK:  This Shah Malik again.  This
 9    probabilistic has to be done for the whole reactor vessel
10    and we are using this approximate exponential decay at the
11    moment.  That is being further looked at in Reg. Guide 1.99,
12    Rev. 3 revision that will be coming up soon also, how
13    appropriate that term is.  But in all likelihood, if it does
14    not change, that is what we will be using, because those are
15    like millions of calculations, it has to be on the fly in
16    the computer to do those, calculating the probability of
17    failure.  And unless somebody builds up such a detailed
18    model through the thickness of the vessel to go to the
19    individual points, which the DORT calculation is showing up,
20    that will make much more complication at the other end.
21              But the licensee does have the option, in their
22    likelihood, they will save their plan and they can get a
23    little bit of instructing, they could use that actual
24    calculation.  It is not going to stop them.
25              DR. SEALE:  About 3-1/2 or 4 at nine inches is the
.                                                                99
 1    difference between the two.
 2              DR. TSOULFANIDIS:  A factor of 4.
 3              DR. SEALE:  Yeah, 3-1/2 or 4.
 4              DR. KRESS:  Can't you just change your exponential
 5    function so it fits it better?
 6              DR. MALIK:  It will be then vessel-specific.
 7              DR. KRESS:  Oh, it is vessel-specific, okay.
 8              DR. MALIK:  It will then become vessel-specific.
 9              DR. KRESS:  Okay.  You would have to run a lot of
10    them.
11              CHAIRMAN SHACK:  But how many vessels have you
12    looked at?  John says he is looking at a bunch.
13              DR. MALIK:  He is looking at four of them right
14    now.
15              CHAIRMAN SHACK:  Four.  Okay.  That is a small
16    sample.
17              DR. SEALE:  Yeah.
18              CHAIRMAN SHACK:  Do we see a consistent picture
19    like that, though?
20              MR. JONES:  I was just going to see a relatively
21    consistent picture, yes.
22              DR. KRESS:  So you could change it then.
23              MR. JONES:  We are in that area of probabilistic
24    fraction mechanics and that work is being done.  We are
25    exploring options, I guess.
.                                                               100
 1              DR. CHOKSHI:  It is going, I think, you know, both
 2    the probabilistic PTS and Reg. Guide 1.99, we need to look
 3    at the whole thing.
 4              CHAIRMAN SHACK:  As I mentioned, I mean obviously
 5    you do know more about the uncertainty than you did when you
 6    wrote 1.99, Rev. 2.  I mean it just has to be factored in.
 7              DR. CHOKSHI:  Because some of the other comments
 8    from Framatome, you know, we need to look at the whole thing
 9    and see what are the implications.
10              CHAIRMAN SHACK:  I guess maybe the first thing is,
11    what do we want presented at the full committee?  How much
12    time do we have?
13              MR. DUDLEY:  We have an hour-and-a-half.
14              DR. SEALE:  Working backwards, I would think it
15    would be worthwhile to see the comparison between the MCNP
16    and transport calculations for those four cases.  I would
17    imagine that you could probably sample particularly the EPRI
18    or the NEI comments.
19              DR. KRESS:  I would eliminate most of those
20    because --
21              DR. SEALE:  Yeah, but just to indicate the nature
22    of the more relevant ones.
23              DR. KRESS:  I would just show that pie chart and
24    indicate maybe the general nature.
25              DR. SEALE:  Yes.  Yes.  Then I think you would
.                                                               101
 1    probably go through the front part of it pretty quickly.
 2              CHAIRMAN SHACK:  Okay.  That maybe seems to me a
 3    reasonable thing to do, to basically just, you know, very
 4    abbreviate the discussion of the comments, but to keep the
 5    rest.
 6              DR. SEALE:  The pie chart is a lot of the thrust
 7    really.
 8              MR. DUDLEY:  How much detail do you need on a
 9    NUREG?
10              CHAIRMAN SHACK:  Well, Bob was saying he sort of
11    liked that detail.
12              DR. SEALE:  Well, I think it is the phase of
13    maturity that I think is important to understand when you
14    are making these kinds of questions.  And I think the
15    comments from Framatome suggest that at some point down the
16    road, it may be appropriate to examine some of these issues.
17              DR. KRESS:  It seems like a general principle, if
18    you reduce the uncertainties, you are liable to get some
19    benefit.
20              DR. SEALE:  Yeah.  And it is worthwhile for the
21    committee to know that, you know, the rolling tide of
22    understanding has gotten to this point, and so maybe it is
23    going to be time to ask some of these questions again.
24              DR. TSOULFANIDIS:  That is not part of this NUREG.
25              DR. SEALE:  No, I am not saying that.
.                                                               102
 1              DR. KRESS:  That is something else.
 2              DR. SEALE:  But it brings the committee up to date
 3    on the status of that calculation.
 4              MR. JONES:  So what I am hearing is much of what
 5    John presented, you would like to hear in abbreviated form,
 6    and you would like to see the pie chart.  Do you want any
 7    comments at all presented by John, or how do you want to
 8    handle that, any of the industry -- any of the public
 9    comments?
10              DR. KRESS:  I think the full committee can read
11    most of those.
12              MR. JONES:  Okay.
13              CHAIRMAN SHACK:  You have got that nice table.
14              DR. KRESS:  You have got a nice table and it is
15    really easy to follow.
16              MR. JONES:  Okay.
17              CHAIRMAN SHACK:  One by one, and I think that is
18    -- you know, the one substantive comment is the one on the
19    BWR and, you know, rather than the sort of ex cathedra
20    statement that it works, you know, you might point that out
21    when you get to the NUREG, that you have got the
22    calculations.
23              DR. KRESS:  Yeah, I think that be worthwhile.
24              CHAIRMAN SHACK:  Because some of the others are
25    more -- you know, yes, they are important, but I think those
.                                                               103
 1    are readable.
 2              DR. KRESS:  I would like to see a little more of
 3    the technical basis behind your weighting factors for the
 4    three uncertainties.  Those look a little arbitrary to me. 
 5    Maybe that is all there is to them, but it left me a little
 6    cold.
 7              MR. JONES:  Well, what I heard during the break, I
 8    think part of what you see there is some of us have toiled
 9    in the nuclear analysis part of the industry for a long
10    time, and what we were trying to do is say, what is a
11    reasonable way to group these sources of uncertainty and
12    weight them properly?  Maybe that is just what is needed. 
13    But those of us toil in that nuclear, you know that a lot of
14    that is experiential.
15              DR. KRESS:  I understand, that is probably what it
16    is.
17              MR. JONES:  Right.  So we will address that and
18    try to do a good job with it.
19              DR. KRESS:  Okay.  I am pretty sure the question
20    will come up, knowing the committee.
21              CHAIRMAN SHACK:  Well, not if they don't discuss
22    that comment, that is one way to get around it.
23              [Laughter.]
24              DR. KRESS:  You're right, but George will find it.
25              DR. SEALE:  We might may make him bring it up
.                                                               104
 1    anyway.
 2              [Laughter.]
 3              CHAIRMAN SHACK:  That is enough then to give you a
 4    notion of what to bring for the hour-and-a-half.
 5              MR. JONES:  Okay.
 6              DR. SEALE:  Nick, was there anything else?
 7              DR. TSOULFANIDIS:  I was going to ask John
 8    something.  The temperature of the moderator is important,
 9    of course, and it is not constant, even in the PWR, as you
10    go up.  Has this been addressed?  It is lower at the bottom
11    or at the top?  The average, I recall is, what, .7 water
12    density in the PWR, right?  But does this produce an effect,
13    did anybody look at that?
14              DR. CAREW:  The guide raises these issues and
15    states that you must account for the temperature, and we
16    have looked at that.  We looked at the temperature of the
17    coolant, it enters several places.  It enters in the
18    downcomer temperature, and that is typically, that is an
19    uncertainty that we have looked at in the uncertainty
20    analysis.  And, typically, when the temperature, the inlet
21    temperature is used, the uncertainty in the inlet
22    temperature contributes about 2 percent at the most to the
23    uncertainty in the fluence, so it gets lost compared to the
24    other larger uncertainties.
25              The temperature in the bypass region also is known
.                                                               105
 1    and also the uncertainty -- well, let me go back a step.  In
 2    an operating plant, the uncertainty due to the measurement
 3    uncertainty in the inlet temperature, it contributes about
 4    1, probably 1 percent, 1-1/2 percent to the fluence
 5    uncertainty.  Then there is a question, in each one of those
 6    regions, you have a distinct temperature, and, again, the
 7    absolute temperature -- across the core, there is maybe a 60
 8    degree temperature rise across the core, in the center of
 9    the core, and the peripheral bundles where it counts is
10    maybe a 30 degree rise.  So the uncertainty in that
11    temperature is much smaller, or the effect of that is much
12    smaller than the uncertainty in the downcomer where you have
13    a much larger thickness of water and you have a larger --
14    you have a significant uncertainty.
15              So the major contributor to those temperatures
16    turns out to be relatively small, and it is swamped by the
17    uncertainty in the source which typically could be 10
18    percent.  So you are comparing a 2 percent, a 1 percent
19    uncertainty to an uncertainty in the source which is 10
20    percent, you won't even see it.
21              That doesn't account for the uncertainties in the
22    problem, the nuclear data uncertainties.  Well, let me go
23    back a step.  The overall uncertainty in a good calculation
24    nowadays may be of the order of like 15 percent.  So you are
25    going to add on or subtract a 1 or 2 percent uncertainty,
.                                                               106
 1    you will never see it.  So, in practice, the temperatures
 2    really are not that important, but they are a consideration
 3    and we have looked at them.
 4              DR. TSOULFANIDIS:  One other source of uncertainty
 5    is if you take the pins in one assembly, they don't all have
 6    the same burnup.  Therefore, if you look at them as a source
 7    of neutrons, they don't produce the same number of numbers. 
 8    And this critical, as we know, for the last row of
 9    assemblies at the periphery of the core.
10              In the Monte Carlo calculation, you pointed out
11    that you looked at the pins individually, if I understood
12    you correctly, and, therefore, this neutron source was
13    introduced into the Monte Carlo calculation based on pin by
14    pin.  I assume this was based on isotopics calculations.
15              DR. CAREW:  Right.
16              DR. TSOULFANIDIS:  How was this done with the
17    deterministic code?
18              DR. CAREW:  Okay.  In the deterministic DORT
19    calculation, we also included the exact same source, the
20    exact same pin powers and the exact same exposure.  So the
21    same data went to both calculations.  The only difference
22    was that in the DORT calculation, that information had to be
23    smeared and mapped onto an R theta geometry which distorted
24    it.  But we have a code that does that and the mesh on the
25    periphery of those peripheral bundles is pretty fine.  So we
.                                                               107
 1    get a pretty detailed, I mean if we have a 15 by 15 bundle
 2    on the core, we don't have a mesh of 15 by 15 in those
 3    peripheral bundles, but we have probably close to 200 mesh
 4    points in that, so it gets a pretty good representation.
 5              DR. KRESS:  I was fascinated by the fact that you
 6    could use a homogeneous calculation and get the same answers
 7    as a heterogeneous one.  I don't suppose that is very
 8    surprising.  But what are the implications of that?  Does
 9    that help you make the calculations easier or does it help
10    somebody do it a lot faster, or does that help any?
11              DR. CAREW:  Yeah, I was amazed also, kind of
12    disappointed in a way.  But it may be due to -- we are
13    looking at fast neutrons, I don't see that detail they are
14    going so fast.  They have scattering events that occur like
15    every six inches or something like that.
16              DR. KRESS:  It is the scattering that makes it
17    different.
18              DR. CAREW:  So they don't see that detail.  But it
19    makes a big, a very, very big simplification.  It means that
20    in the DORT calculation, where you really can't represent it
21    explicitly, that DORT calculation does a good job, and that
22    is what we see.
23              DR. KRESS:  That explains why the DORT does a good
24    job.
25              DR. CAREW:  Exactly.
.                                                               108
 1              DR. KRESS:  That is the implication of that.
 2              DR. CAREW:  Right.  Yes.  I thought we might give
 3    it streaming, some kind of streaming effect, but it didn't
 4    occur.  We don't have it.
 5              DR. KRESS:  You might want to bring that detail
 6    out a little more when you show that particular slide.
 7              DR. CAREW:  Okay.
 8              CHAIRMAN SHACK:  Is your smearing code described
 9    in a NUREG, I mean is that -- that would seem like an
10    important input to these kinds of calculations, just how
11    that smearing is done.
12              DR. CAREW:  Well, you mean the mapping code?
13              CHAIRMAN SHACK:  Yeah.
14              DR. CAREW:  There are several different mapping
15    codes out there.  We have a code that is referenced in the
16    Reg. Guide and there are different codes that do that same
17    job.
18              CHAIRMAN SHACK:  Have you looked at the
19    sensitivity of the calculation to those mapping codes?
20              DR. CAREW:  Well, let me go back a step, give you
21    some perspective.  The effect of all that detail on the
22    periphery is worth about maybe 7 or 8 percent to the vessel
23    fluence.  It is not an enormous effect, but it goes -- I
24    mean it helps, it reduces the fluence, so it is worth going
25    after.  So we are talking about only, you know, it is a 7 or
.                                                               109
 1    8 percent effect.  So you are not going to -- we have a
 2    requirement in the Reg. Guide that the peripheral bundle
 3    should be represented in such a way that the area of the
 4    peripheral bundle is represented in the R theta mesh, is
 5    good to half a percent.  So we require an accurate modeling
 6    of that peripheral boundary.
 7              And I don't know that you have to put in each pin
 8    explicitly.  You probably could get by with a coarser
 9    representation, and it is probably not really not necessary
10    probably.  If the neutrons aren't seeing a difference
11    between the void fraction inside or outside the bundle, they
12    are probably not going to see whether it is the second or
13    third row in pin.
14              CHAIRMAN SHACK:  If there are no further
15    questions, I believe we can bring the subcommittee meeting
16    to an end.  It was a very good presentation, I enjoyed it
17    very much.
18              [Whereupon, at 11:38 a.m., the meeting concluded.]
19
20
21
22
23
24
25