Final Construction Completion Report, Wyoming Volume III, Above-Grade Tailing Impoundment Design Enhancement.
Accession Number: ML072200054
Date Released: Thursday, August 16, 2007
Package Contents
The following links on this page are to Adobe Portable Document Format (PDF) files. To obtain a free viewer for displaying this format, see our Plugins, Viewers, and Other Tools.
- ML072200056 - Final Construction Completion Report, Gas Hills Wyoming Site, Volume III - Above-Grade Tailings Impoundment Design Enhancement. (64 page(s), 6/30/2007)
- ML072200058 - Final Construction Completion Report, Gas Hills Wyoming Site, Volume III - Above-Grade Tailings Impoundment Design Enhancement, Attachments 1 and 2. (62 page(s), 6/30/2007)
- ML072200060 - Final Construction Completion Report, Gas Hills Wyoming Site, Volume III - Above-Grade Tailings Impoundment Design Enhancement, Appendix C. (49 page(s), 6/30/2007)
- ML072200061 - Final Construction Completion Report, Gas Hills Wyoming Site, Volume III - Above-Grade Tailings Impoundment Design Enhancement, Appendix D. (17 page(s), 6/30/2007)
- ML072200062 - Final Construction Completion Report, Volume IV - A-9 Repository Design Enhancement and C-18 Pit Reclamation Plates. (2 page(s), 6/30/2007)
- ML072200063 - Drawing GH-A9-01-AB, "Final A-9 Repository Site Plan Reflection Post-Reclamation Construction Final Grades." Sheet 1 of 12. (1 page(s), 6/30/2007)
- ML072200064 - Drawing GH-A9-02-AB, "A-9 Repository Final Contours and Survey Verification Points Contaminated Fill Area." Sheet 2 of 12. (1 page(s), 6/30/2007)
- ML072200065 - Drawing GH-A9-03-AB, "A-9 Repository 1999 and 2000 Compaction Test Locations Contaminated Fill Area." Sheet 3 of 12. (1 page(s), 6/30/2007)
- ML072200067 - Drawing GH-A9-04-AB, "A-9 Repository 2001, 2002 and 2003 Compaction Test Locations Contaminated Fill Area." Sheet 4 of 12. (1 page(s), 6/30/2007)
- ML072200068 - Drawing GH-A9-05-AB, "A-9 Repository Final Contours and Survey Verification Points Radon Barrier." Sheet 5 of 12. (1 page(s), 6/30/2007)
- ML072200069 - Drawing GH-A9-06-AB, "A-9 Repository Compaction Test Locations Radon Barrier." Sheet 6 of 12. (1 page(s), 6/30/2007)
- ML072200070 - Drawing GH-A9-07--AB, "A-9 Repository Visual Depth Check Verification Test Locations Radon Barrier." Sheet 7 of 12. (1 page(s), 6/30/2007)
- ML072200071 - Drawing GH-A9-08-AB, "A-9 Repository Final Contours and Survey Verification Points Frost Protection Layer Toe Protection Subgrade and West Diversion Channel." Sheet 8 of 12. (1 page(s), 6/30/2007)
- ML072200072 - Drawing GH-A9-09-AB, "A-9 Repository Compaction Test Locations Frost Protection Layer Toe Protection Subgrade and West Diversion Channel." Sheet 9 of 12. (1 page(s), 6/30/2007)
- ML072200073 - Drawing GH-A9-10-AB, "A-9 Repository Survey Verification Points Type A Bedding Erosion Protection Placement." Sheet 10 of 12. (1 page(s), 6/30/2007)
- ML072200075 - Drawing GH-A9-11-AB, "A-9 Repository Final Contours and Survey Verification Points Erosion Protection Placement." Sheet 11 of 12. (1 page(s), 6/30/2007)
- ML072200076 - Drawing GH-A9-12-AB, "A-9 Repository In Place Gradation and Visual Depth Check Test Locations Erosion Protection Placement." Sheet 12 of 12. (1 page(s), 6/30/2007)
- ML072200077 - Drawing GH-C18-01-AB, "Final C-18 Pit Reclamation Site Plan Reflecting Post- Reclamation Construction Final Grades." Sheet 1 of 4. (1 page(s), 6/30/2007)
- ML072200078 - Drawing GH-C18-02-AB, "Reclamation of the C-18 Pit Compaction Test Locations Backfill Material Elevation 6844 to Elevation 6863." Sheet 2 of 4. (1 page(s), 6/30/2007)
- ML072200079 - Drawing GH-C18-03-AB, "Reclamation of the C-18 Pit Compaction Test Locations Backfill Material Elevation 6864 to Elevation 6883." Sheet 3 of 4. (1 page(s), 6/30/2007)
- ML072200080 - Drawing GH-C18-04-AB, "Reclamation of the C-18 Pit Final Contours and Compaction Test Locations Backfill Material Elevation 6884 to Elevation 6902." Sheet 4 to 4. (1 page(s), 6/30/2007)