Abstract
RELAP5/MOD2 simulations of level swell of saturated liquid in a large (5 m diameter, 22 m high) vessel are reported. For certain nodalizations RELAP5 is shown to predict the measured void fraction profile with fair accuracy. RELAP5 results are shown to be dependent upon nodalization with the accuracy of computed results deteriorating significantly when a large number of nodes is employed.