Meeting Details
Category 2Date
June 29, 2017
Time
12:30 pm–5:00 pm EDT
Location
NRC One White Flint North
11555 Rockville Pike, ACRS Room T2B3
Rockville, MD
Agenda
Meeting Info
Purpose
The Nuclear Regulatory Commission (NRC) will meet with industry to discuss its response to the Flowserve Part 21 notification and recent operating experience. The purpose is to solicit input from industry on recent actions taken with regard to the Flowserve Part 21 notification as a result of the valve failure at LaSalle County Nuclear Generating Station, Unit 2.
Teleconference / Webinar
Bridge Number: 8008575159
Passcode: 9464650
Documents
| Document Title | Description |
|---|---|
| ML13064A012 | Notification of Potential Part 21 Report re Wedge Pin Failure of an Anchor/Darling Double-Disc Gate Valve. |
| ML17179A480 | 06/29/2017 Public Meeting on Anchor/Darling Valve Issue |
| ML17153A053 | NRC Information Notice 2017-03: Anchor/Darling Double Disc Gate Valve Wedge Pin and Stem-Disc Separation Failures. |
| ML17137A387 | 05/16/2017 - Closed Meeting Summary with the Pressurized Water Owners' Group and the Boiling Water Owners Group to Discuss Anchor Darling Gate Valve Part 21 Issues. |
Participants
NRC Staff
External Participants
Nuclear Energy Institute (NEI)
Contact
Lynnea Wilkins
(301) 415-1377
Brian Benney
(301) 415-2767