Forwards updated LERs 80-036/03X-1,80-058/03X-1, 82-041/03X-1,82-051/03X-1 & 82-059/03X-1.
Accession Number: ML20091J029
Date Released: Tuesday, April 14, 2020
Package Contents
The following links on this page are to Adobe Portable Document Format (PDF) files. To obtain a free viewer for displaying this format, see our Plugins, Viewers, and Other Tools.
- ML20091J027 - Forwards updated LERs 80-036/03X-1,80-058/03X-1, 82-041/03X-1,82-051/03X-1 & 82-059/03X-1. (1 page(s), 6/1/1984)
- ML20091J061 - Updated LER 80-036/03X-1:on 800827,while performing Surveillance Procedure SP-320,decay heat pump discharge throttle valve DHV-111 would not control flow in automatic. Caused by water in sensing line. (2 page(s), 6/1/1984)
- ML20091J082 - Updated LER 80-058/03X-1:on 800806,while performing surveillance re ECCS pump operability,decay heat pump discharge throttle valve DHV-110A would not control flow in automatic.Caused by air in sensing line. (2 page(s), 6/1/1984)
- ML20091J087 - Updated LER 82-041/03X-1:on 820608,while verifying operability of boron injection sources & pumps,DHV-111 failed to control flow,contrary to Tech Specs.Caused by stuck high flow switch. (2 page(s), 6/1/1984)
- ML20091J097 - Updated LER 82-051/03X-1:on 820728,while recirculating borated water storage tank w/decay heat pump 1A,DHV-110 determined inoperable,contrary to Tech Specs.Caused by air in DH-43-FIS sensing lines. (2 page(s), 6/1/1984)