Addl response to FOIA request for documents re IE Insp Rept 50-358/81-13.Forwards App A documents.Documents also available in PDR.
Accession Number: ML20065A137
Date Released: Sunday, November 8, 2020
Package Contents
The following links on this page are to Adobe Portable Document Format (PDF) files. To obtain a free viewer for displaying this format, see our Plugins, Viewers, and Other Tools.
- ML20070V749 - Addl response to FOIA request for documents re IE Insp Rept 50-358/81-13.Forwards App A documents.Documents also available in PDR. (7 page(s), 12/27/1982)
- ML20070V810 - "Hydrostatic/Pneumatic Test Rept RR-26." (11 page(s), 2/26/1979)
- ML20070V819 - Forwards "Hydrostatic/Pneumatic Test Rept RR-25." (2 page(s), 4/2/1980)
- ML20070V953 - "Flushing Procedure,Drain Sys." (520 page(s), 7/6/1977)
- ML20070V821 - "Hydrostatic/Pneumatic Test Rept RR-25." (13 page(s), 3/5/1979)
- ML20065A135 - Informs that acceptance criteria suitable for lead Mark II plants.Present ECCS analysis contains adequate margins for assessing performance. (3 page(s), 3/13/1979)
- ML20070V762 - IE Insp Rept 50-358/78-06 on 780228 & 0301-03.No noncompliance noted.Major areas inspected:operational staffing,safety committee activity,plant procedures & preoperational test QA program. (4 page(s), 3/20/1978)
- ML20070V930 - Forwards "Hydrostatic/Pneumatic Test Rept RR-53." (4 page(s), 5/24/1980)
- ML20070V755 - Press release discussing ACRS rept re Cincinnati Gas & Electric Co application for license.Facility will use BWR & have electrical output of 810 MWt. (1 page(s), 3/22/1979)
- ML20070V936 - "Hydrostatic/Pneumatic Test Rept RR-53." (11 page(s), 9/27/1979)
- ML20263J391 - "P & ID Reactor Recirculation (RR)." Sheet 2 of 2. (1 page(s), 3/18/1981)
- ML20070V825 - Forwards "Hydrostatic/Pneumatic Test Rept RR-31." (5 page(s), 10/9/1979)
- ML20070V751 - Submits TW Applegate charges against NRC investigator G Phillip re violation of law (ref 10CFR1250.3). (26 page(s), 12/27/1982)
- ML20070V828 - "Hydrostatic/Pneumatic Test Rept RR-31." (14 page(s), 3/14/1979)
- ML20070V872 - "Hydrostatic/Pneumatic Test Rept RR-28." Related documentation encl. (143 page(s), 3/2/1979)
- ML20070V910 - Forwards "Hydrostatic/Pneumatic Test Rept RR-30." (5 page(s), 10/9/1979)
- ML20070V834 - Forwards "Hydrostatic/Pneumatic Test Rept RR-27." (3 page(s), 9/28/1979)
- ML20070V765 - Forwards IE Insp Rept 50-358/78-20 on 780911-15,21-22 & 1024-25.No noncompliance noted. (2 page(s), 11/17/1978)
- ML20070V785 - "Investigation Program of Fillet Weld Size on P-W Industries Cable Pan Hangers." (233 page(s), 8/22/1980)
- ML20070V797 - Forwards "Hydrostatic/Pneumatic Test Rept RR-32." (5 page(s), 1/23/1980)
- ML20070V916 - "Hydrostatic/Pneumatic Test Rept RR-30." Related documentation encl. (35 page(s), 3/2/1979)
- ML20070V756 - "Investigation re Apparent False Statements,Cincinnati Gas & Electric Co," draft. (17 page(s), 5/24/1979)
- ML20070V847 - Forwards "Hydrostatic/Pneumatic Test Rept RR-29." (6 page(s), 10/9/1979)
- ML20070V759 - Forwards IE Insp Rept 50-358/78-06 on 780228 & 0301-03.No noncompliance noted. (2 page(s), 3/22/1978)
- ML20070V844 - "Hydrostatic/Pneumatic Test Rept RR-27." (15 page(s), 3/1/1979)
- ML20070V783 - Forwards minutes of premeeting w/P-W Industries re compliance to Spec H-2803.Gladstone Labs ltr w/independent opinion on supplied matl encl. (15 page(s), 4/14/1980)
- ML20070V808 - Forwards "Hydrostatic/Pneumatic Test Rept RR-26." (4 page(s), 2/27/1979)
- ML20070V801 - "Hydrostatic/Pneumatic Test Rept RR-32." (11 page(s), 3/6/1979)
- ML20070V753 - Partial transcripts of Schott & Borgmann before ACRS re backup svcs for technical staff. (24 page(s), 12/27/1982)
- ML20070V969 - "Separation of Electrical Equipment Plant Wide Field Audit Procedure." (11 page(s), 2/8/1980)
- ML20070V860 - Forwards "Hydrostatic/Pneumatic Test Rept RR-28." (3 page(s), 9/28/1979)
- ML20070V853 - "Hydrostatic/Pneumatic Test Rept RR-29." (10 page(s), 3/5/1979)
- ML20263J388 - "P & ID Reactor Recirculation (RR)." Sheet 1 of 2. (1 page(s), 3/18/1981)