| LICENSEE: ABB INC | |||
| SITE: ABB INC | EVENT NOTIFICATION NUMBER: 38781 | ||
| DOCKET: | EVENT DATE: 03-18-02 | ||
| RX TYPE: | EVENT TIME: | ||
| VENDOR: | NOTIFICATION DATE: 03-19-02 | ||
| EMERGENCY CLASS: N/A | REGION: 2 | STATE: FL | TIME: 12:53 |
| HQ OPS OFFICER: GERRY WAIG | |||
| 10 CFR SECTION: CCCC UNSPECIFIED PARAGRAPH | |||
INITIAL NOTIFICATION OF POTENTIAL DEFECT CLASS 1E TYPE CV-2 AND CV-22 RELAYS
"This letter is the initial notification of a deviation concerning our Class 1E type CV-2 and CV-22 relays.
"One of our customers notified us that several of the CV-2 relays they had recently received did not have a particular assembly on the moving disc which other CV-2 relays on the same order did have. Discussions with this customer concluded they were speaking of a weight assembly that is used in balancing the moving disc and is required as a part of the completed relay.
"Upon visual examination of the CV-2 relays returned to us for corrective action this deviation was confirmed. A preliminary investigation showed that our manufacturing system allowed for the potential for this deviation to occur.
"Details will be provided in our written notification forthcoming within the next thirty days."