Skip to main content

TRACE VVER-440/V-213 Model Validation (NUREG/IA-0485)

On this page:

Download complete document

Publication Information

Manuscript Completed: February 2017
Date Published: December 2018

Prepared by:
S. Iegan, A. Mazur, Y. Vorobyov, O. Zhabin, S. Yanovskiy

State Nuclear Regulatory Inspectorate of Ukraine
and
State Scientific and Technical Center
for Nuclear and Radiation Safety of Ukraine
9/11 Arsenalna str. Kyiv, Ukraine 01011

Kirk Tien, NRC Project Manager

Division of Systems Analysis
Office of Nuclear Regulatory Research
U.S. Nuclear Regulatory Commission
Washington, DC 20555-0001

Prepared as part of:
The Agreement on Research Participation and Technical Exchange
Under the Thermal-Hydraulic Code Applications and Maintenance Program (CAMP)

Published by:
U.S. Nuclear Regulatory Commission
Washington, DC 20555-0001

Availability Notice

Abstract

This report is developed by the State Nuclear Regulatory Inspectorate of Ukraine (SNRIU) and its technical support organization, the State Scientific and Technical Center for Nuclear and Radiation Safety of Ukraine (SSTC NRS), under Implementing Agreement On Thermal-Hydraulic Code Applications And Maintenance Between The United States Nuclear Regulatory Commission and State Nuclear Regulatory Inspectorate of Ukraine (signed in 2014) in accordance with Article III, Section C, of the Agreement.

The report provides results of the validation calculations conducted with application of SSTC NRS model of VVER-440 for TRACE computer code. The calculation scenarios simulate actual incidents that occurred at Ukrainian NPPs.