The NRC is modernizing nrc.gov with an updated design and improved navigation to enhance usability. We are committed to a smooth transition and will work to minimize any disruption. The site may be briefly unavailable at times during launch. Thank you for your patience.
Post-Test Calculation of the ROSA/LSTF Test 3-1 using RELAP5/mod3.3 (NUREG/IA-0409)
On this page:
Download complete document
Publication Information
Manuscript Completed: January 2012
Date Published: March 2012
Prepared by:
V. Martinez, F. Reventós, C. Pretel
Institute of Energy Technologies
Technical University of Catalonia
ETSEIB, Av. Diagonal 647, Pav. C
08028 Barcelona, SPAIN
A. Calvo, NRC Project Manager
Office of Nuclear Regulatory Research
U.S. Nuclear Regulatory Commission
Washington, DC 20555-0001
Prepared as part of:
The Agreement on Research Participation and Technical Exchange
Under the Thermal-Hydraulic Code Applications and Maintenance Program (CAMP)
Published by:
U.S. Nuclear Regulatory Commission
Washington, DC 20555-0001
Abstract
The Thermalhydraulic Studies Group of Technical University of Catalonia (UPC) holds a large background in nuclear safety studies in the field of Nuclear Power Plant (NPP) code simulators. RELAP5mod3.3 has been used in this study in order to analyze the LSTF Test 3-1, which simulates an anticipated transient without scram (ATWS) as a result of a small break LOCA without rods insertion (but with scram signal) and loss of off-site power. Two local phenomena have been object of study: U-tube liquid accumulation due to CCFL at the inlet of the SG Utubes, and loop seal behavior during the transient.
Page Last Reviewed/Updated Tuesday, March 09, 2021