Technical Guidance

This page includes links to files in non-HTML format. See Plugins, Viewers, and Other Tools for more information.

AreaChapterTitleDescriptionCN Number
TGTechnical Guidance
TGASME3&11ASME SECTIONS III & XIGuidance on the ASME Sections III and XI, as it relates to Code interpretations, use of engineering judgement, and flaw evaluation.96-022
TGASMEIIIASME Boiler and Pressure Vessel Code, Section IIIGuidance on procurement of ASME Section III replacements that are not currently available in full compliance with the stamping and documentation requirements of Section III of the Code.89-011
TGASMEXIAASME Boiler and Pressure Vessel Code, Section XIGuidance for the performance of system pressure tests (leakage and hydrostatic) using nuclear heating and to provide a definition of plant startup with regard to pressure testing.86-054
TGASMEXIBASME Boiler and Pressure Vessel Code, Section XIGuidance on testing normally closed check valves specified in paragraph IWV-3520 of the ASME Code Section XI, 1983Edition.86-026
TGFPLUGSMechanical - Freeze PlugsGuidance on the use and inspection of freeze plugs. Describes problems encountered when using freeze plugs during system maintenance.93-005
TGICECONDIce Condenser System InspectionsGuidance for inspecting the Ice Condenser (IC) system.05-015
TGLCOPMMaintenance - Voluntary Entry Into Limiting Conditions for Operation Action Statements to Perform Preventive MaintenanceGuidance for use of LCOs and the Maintenance Rule (10 CFR 50.65) when performing online preventive maintenance.02-001
TGLEAKSEALAssessing On-Line Leak Sealing of ASME Code Class 1 & 2Provide information to inspectors regarding use of leak-sealing activities for liquid-filled systems.97-011
TGNOEDGASOperations - Notice of Enforcement Discretion For Gaseous Diffusion PlantsStaff guidance for the process to exercise enforcement discretion with regard to limiting conditions for operation (LCO) in gaseous diffusion plant Technical SafetyRequirements or other certificate conditions.99-008
TGORGCOATFilled Organic Coatings Used In Maintenance of Safety Related EquipmentProvide information to inspectors regarding use of filled organic coatings in the maintenance of fluid systems.94-018
TGPRECONDPreconditioning of Structures, Systems and Components before Determining Operabilty.Guidance on evaluating the acceptability of preconditioning of Structures, Systems and Components (SSCs) before the performance of operability, surveillance, or conformance testing.98-014
TGSAFETYOperation - Safety and ComplianceA Commission approved discussion of safety and compliance.07-028
TGSGTUBESteam Generator Plugs and Sleeving RepairsProvide inspection guidance to review licensee activities on plugging or sleeving repairs of defective steam generator tubing.94-014
TGSTSINTRLicensee Technical Specifications InterpretationsLicensee-issued TS interpretations are not approved NRR staff positions.97-001
TGSTSSURVSTS Surveillance Sections - Locked or Otherwise Secured ComponentsProvides inspection criteria for what constitutes a "locked close" valve.77-025
TGSTS10STS Section 1.0 - OperabilityPrincipal criteria for proper application of the STS definition of operable/operability as applied to systems and components which provide necessary support functions.86-026
TGSTS10DSTS Section 1.0 - DefinitionsDefines the scope of testing necessary to meet the STS definitions of a CFT.86-054
TGSTS30TSTS Section 3.0 - Acceptable Measurement Tolerances for Technical Specification LimitsTS limits are established with allowances for measurement tolerances already incorporated.78-035
TGSTS3464STS Section 3/4.6.4 - Containment and Drywell Isolation ValvesIsolation valves cannot be deemed operable solely because they are closed.88-006
TGSTS3481STS Section 3/4.8.1 - TDI Diesel Generator Air Roll TestsExplains TDI surveillance testing requirements when action statements apply.88-006
TGSTS375STS Section 3.7.5 - Ultimate Heat SinkAverage water temperature of the ultimate heat sink TS refers to volumetric, not time averaged temperature88-017
TGSTS428STS Section 4.2.8.X.X - Surveillance Requirements - 125-Volt Battery BankSurveillance test criteria for procedures that apply to all wet storage batteries79-022
TGSTS451STS Section 4.5.1 - Standard Technical Specifications (BWR)Licensees should may use remote position indicating lights in the control room to verify that valves are in the correct position but it is not the intent of SRs that only local valve position indication be used.86-026
TGSTS48112STS Section 4.8.1.1.2 - Surveillance Testing of D/G Lockout FeaturesProvides the NRC position on surveillance testing of diesel generator lockout features.86-026
TGTG9900Technical GuidanceTechnical Guidance 05/12/8686-026