SSINS: 6370
Accession No.:
8006190044
IN 80-32
UNITED STATES
NUCLEAR REGULATORY COMMISSION
OFFICE OF INSPECTION AND ENFORCEMENT
WASHINGTON, D.C. 20555
August 29, 1980
Information Notice No. 80-32: CLARIFICATION OF CERTAIN REQUIREMENTS FOR
EXCLUSIVE-USE SHIPMENTS OF RADIOACTIVE
MATERIALS
Background
In mid-1979,the NRC initiated an enhanced program for inspection of
shipments of radioactive materials, including, in particular, low level
wastes. In conjunction with this effort, civil penalties have been assessed
for violation of associated regulatory requirements. IE Bulletins 79-19 and
79-20, "Packaging of Low Level Radioactive Waste for Transport and Burial,"
issued August 8, 1979 and Information Notice No. 79-21, "Transportation and
Commercial Burial of Radioactive Material," issued September 7, 1979,
provide background in this regard.
During the past year, this augmented inspection/enforcement program has
prompted a number of questions on the proper application of certain
regulatory requirements. These questions involve mainly the problems and
deficiencies associated with exclusive use highway shipments of low-level
radioactive wastes. The purpose of this Notice is to discuss the questions
and clarify the applicability of certain requirements.
Application of 49 CFR 173.393(i) and (j)
Numerous questions involve the application of the limits of radiation levels
of exclusive use shipments as prescribed in 49 CFR 173.393(j). As stated
therein, the regulation reads
(j) Packages for which the radiation dose rate exceeds the limits
specified in paragraph (i) of this section, but does not exceed at
any time during transportation any of the limits specified in
paragraphs (j)(l) through (4) of this section may be transported
in a transport vehicle which has been consigned as exclusive use
(except aircraft). Specific instructions for maintenance of the
exclusive use (sole use) shipment controls must be provided by the
shipper to the carrier. Such instructions must be included with
the shipping paper information:
(1) 1,000 millirem per hour at 3 feet from the external surface
of the package (closed transport vehicle only);
(2) 200 millirem per hour at any point on the external surface of
the car or vehicle (closed transport vehicle only);
.
IN 80-32
August 29, 1980
Page 2 of 8
(3) Ten millirem per hour at any point 2 meters (six feet) from
the vertical planes projected by the outer lateral surface
of the car or vehicle; or if the load is transported in an
open transport vehicle, at any point 2 meters (six feet) from
the vertical planes projected from the outer edges of the
vehicle.
(4) 2 millirem per hour in any normally occupied position in the
car or vehicle, except that this provision does not apply to
private motor carriers.
The following questions and answers are intended to delineate the proper
application of the limits cited above. The illustrations in Appendix A and B
are intended to assist in clarifying the application of these limits.
Package Definition - Radiation Levels
1. Q. What limits would apply to packages being transported on an open,
exclusive use transport vehicle?
A. If a shipment is being transported on an open transport vehicle
(i.e., a vehicle not meeting the definition of 173.389(q)), no
package on the vehicle may exceed the limits of 173.393(i). This
limit applies whether or not the vehicle is restricted to
exclusive use.
2. Q. What constitutes a closed transport vehicle?
A. A "closed transport vehicle" includes not only closed trailers and
vans, but also arrangements where personnel barriers are
fabricated around large packages carried on flat bed trailers. In
meeting the requirements of a "closed transport vehicle," as
defined in 173.389(q), if a flat-bed trailer is used and the
radiation levels on the packages exceed the limits of 173.393(i),
the vehicle must be equipped with a personnel barrier which
restricts access to the cargo (packages). In such an instance, the
radiation level limit of 173.393(j)(2) is to be applied at the
exterior surface of the barrier (This barrier need not be solid,
but may be a "see-through" screen, fence, cage, etc. which limits
access from sides, top, and ends.) In practice, so-called
"rag-top" trailers are sometimes used (e.g., a flat-bed with
temporary sides or an open-top, which is equipped with a securely
attached tarpaulin-type cover). When such covers are intact and
secure all openings, they are generally acceptable as the closure
of a "closed transport vehicle". A simple canvas covering wrapped
about the packages on an open-top vehicle would not, however, be
considered sufficient.
3. Q. In the situation described above, is such a "personnel barrier"
considered to be the "package" or a component of the package?
A. The personnel barrier essentially becomes an integral part of the
transport vehicle in such a case and may not be considered to be
a component of the package. In such a case, the exterior of the
.
IN 80-32
August 29, 1980
Page 3 of 8
barrier would be placarded as required for the transport vehicle,
and the packages inside marked as required for packages. Normally
the package and vehicle are not considered to be the same, except
in the case of unpackaged (bulk) shipment of Low Specific Activity
(LSA) materials, as in a highway tank truck or rail tank car (see
173.392(d)(2)) or in certain specific, approved packaging systems
(see 10 CFR 73.24(b)).
4. Q. In the above situation, then, what are the limits for radiation
levels on the packages within such a personnel barrier.
A. 1000 mrem/hr at 3 ft, e.g., the limits for packages within a
closed transport vehicle, as prescribed in 173.393(j)(1).
5. Q. If "packages" such as drums, for instance, are enclosed within an
outer cask "shield" (as opposed to a personnel barrier or closed
vehicle) wherein the outer cask shield is necessary to achieve
compliance with the limit of either 173.393(i) or 173.393(j), may
the inner drum(s) be considered to be the "package"?
A. No. In applying the definition of packaging as prescribed in 49
CFR 171.8, one must consider "... the assembly of one or more
containers and any other components necessary to achieve
compliance with the minimum packaging requirements...". Therefore,
since the outer cask shield is necessary to achieve compliance
with the radiation level limits, it is then considered as a
necessary component of the packaging and the entire assembly,
e.g., the inner drums and outer shield comprise the "package." It
is also subject to the applicable package marking and labeling
requirements, as well as the specification/certification
requirements relative to its specific design.
6. Q. In the situation described above, would the levels of radiation on
the inner drums be limited to the levels of 173.393(j)(1) e.g.,
1000 mrem/hr at 3 ft.
A. No, since the inner drums are not the "package," only the
radiation levels outside of the outer cask shield must meet the
limits of 173.393(i) or (j), as applicable.
7. Q. In monitoring the radiation levels at the external surface of the
transport vehicle, as prescribed in 173.393(j)(2), do the limits
apply at the bottom and top of the vehicle, as well as at the
sides?
A. Yes. 173.393(j)(2) states the limit in terms of ".. .200 millirem
per hour at any point on the external surface of the car or
vehicle...", therefore, the limit applies on the sides, top, and
bottom of the transport vehicle. Some confusion has arisen on this
rule in the past, in that some shippers-have considered the
underside of a highway trailer as an inaccessible location on the
vehicle. This is not the case. The radiation levels on all
surfaces of the vehicle must meet the requirements specified
above.
.
IN 80-32
August 29, 1980
Page 4 of 8
8. Q. In the above situation, does this mean that in applying the limit
of 173.393(j)(3) (e.g., 10 mrem/hr at 6 ft from the sides of the
vehicle) the limit also applies at the top and bottom of the
vehicle?
A. No, 173.393(j)(3) imposes limits at 6 ft from the vertical planes
projected at the outer lateral surface or outer edges of the
vehicle, thus requiring measurements at the sides, front, and ends
only.
9. Q. In 173.393(j)(3) the radiation level limit is prescribed at 10
mrem/hr at 2 m (6 ft) from the outer lateral surfaces of an
exclusive use vehicle. Since 2 m is 6.6 ft, which limit would
apply. 6 ft or 6.6 ft?
A. 6.6 ft would apply.
Exclusive Use Shipment Requirements
10. Q. What is an "exclusive use" shipment?
A. As defined in the DOT regulations, in 49 CFR 173.389(o)
(o) "Exclusive Use" (also referred to as "sole use" or "Full
Load" as used in IAEA regulations) means any shipment:
(1) From a single consignor having the exclusive use of
a transport vehicle or of an aircraft, or of a hold
or compartment of an inland watercraft, or of a
hold, compartment, or defined deck area of a
seagoing vessel; and
(2) For which all initial, intermediate, and final
loading and unloading is carried out by or under
the direction of the consignor, consignee, or his
designated agent.
It should be noted that the 173.389(o) definition is applicable to
radioactive materials. DOT has stated its intent of the term
"exclusive use" as generally meaning that a single consignor has
complete use of the transport vehicle. This does not limit the
consignor to shipping a single material, unless specifically
restricted by a section of the regulations or some specific
prohibition from loading and shipping certain materials in the
same vehicle.
11. Q. Frequently shipments of radioactive waste are made as "exclusive
use" shipments under arrangements whereby the original generator
of the waste utilizes the services of a waste collector (i.e.,
"broker,") who in turn usually engages a common or contract
carrier to transport the shipment or transports the material in
his own-vehicle as a private carrier. On occasion this "broker"
may also be the consignee, e.g., a waste burial site operator.
Because of this complex arrangement, confusion often arises as to
which party is responsible for performing the regulatory
requirements of the "shipper" or "consignor." Can you clarify
this?
.
IN 80-32
August 29, 1980
Page 5 of 8
A. This is often a confusing situation that needs clarification,
principally because the regulations do not specifically define a
"shipper" or "consignor" and yet specify regulatory requirements
that apply to a "shipper" or person who "offers materials for
transportation" by a carrier. In the nuclear waste transportation
business, more than one party (e.g., the original "generator" and
the "broker") can therefore be responsible for functions
attributable to a "shipper."
In specific enforcement cases, the NRC Office of Inspection and
Enforcement will make determinations based on which party actually
performs a shipper function. For instance, if a party is the
original "generator" who prepared the package for transport, this
generator will be held responsible for the proper performance of
the following shipper functions: selecting and preparing the
package; filling and closing the package; measuring the radiation
from the package; marking and labelling the package; preparing the
shipping papers; loading the packages on the transport vehicle and
measuring the radiation from the loaded transport vehicle. From
that point on (i.e., after the loading of the vehicle and the
"transfer" of the material from the generator to the
broker/collector has taken place), the broker/collector will
generally be held responsible for any ensuing shipper functions,
such as those discussed in question 12.
12. Q. In the above situation, assume that a "broker" arranges for pickup
or, himself picks up, radioactive waste from more than one
generator's facility for transport as a single shipment by a
common carrier or by himself as a private carrier. Is it not
required that an exclusive use shipment be from a "single
consignor"?
A. Yes. For that reason it is imperative that the parties involved
(the generators, broker and carrier) very thoroughly understand
their respective roles and responsibilities. The single consignor
for the exclusive use shipment has definite responsibilities. If
the broker arranges for the pickup of radioactive waste from the
facilities of more than one generator for transport as a single
shipment by a common or contract carrier, or if the broker picks
the material up and transports it in his own vehicle as a private
carrier, the broker in effect becomes the "single consignor,"
having the exclusive use of the transport vehicle. It is important
that the broker establish himself in the shipping paper
documentation as the "single consignor." This must include the
provision of appropriate instructions to the carrier for
maintenance of exclusive use shipment controls. The broker is also
responsible for providing appropriate supervision of the loading
and storage of the multiple consignments to assure that the
regulatory requirements are in fact met.
13. Q. In an exclusive use shipment of LSA materials, the shipper is
required by 173.392(c)(9) to provide specific instructions to the
carrier for maintenance of exclusive use shipment controls. What
should such specific instructions include?
.
IN 80-32
August 29, 1980
Page 6 of 8
A. The details of the specific instructions will vary, but the key
word is "maintenance" of the controls. For instance, if the
specific pattern of package loading is critical to maintain
compliance with the radiation limits of 173.393(j), the shippers
instructions should include appropriate instructions to the
carrier to preclude the carrier from changing the loading pattern
within the vehicle or shifting the cargo to a different vehicle
(see 173.392(c)(4)). As an example of such a case, to satisfy a
State requirement on axle weight limits, a carrier shifted
packages within the vehicle; this caused the level of radiation at
the exterior of the vehicle to exceed the limits. In another
recent case, a carrier changed tractors on a shipment. The
replacement tractor was of a different design from the original
and caused the radiation level in the occupied area of the
replacement tractor, which originally had been in compliance, to
exceed the limits of 173.393(j)(4). Although changing of the
tractor by a carrier is not prohibited, if the shipper has
specified exclusive use controls, his instructions to the carrier
should include direct advice that the shipper be notified if a
change is made so that a decision can be made as to whether the
radiation level pattern was affected by the tractor change.
14. Q. 49 CFR 173.393(j)(4) requires that the radiation level in any
"...normally occupied position in the car or vehicle..." be
limited to 2 mrem/hr. Where should this limit be applied in the
case of a tractor with a sleeper cab.
A. The most appropriate application of this rule is to consider the
sleeper portion of such a tractor to be "normally occupied" and
apply the 2 mrem/hr limit in that area. It is quite important to
bear in mind that the limit of 173.393(j)(4) is intended to
minimize the exposure of common carrier transport workers. In
general, therefore, the existence of levels of radiation above
background in any area of the cab of an exclusive-use shipment
would best be interpreted by the shipper as an indicator that a
thorough survey of the cab and evaluation of the loading is
necessary to ensure that the radiation level is and remains below
2 mrem/hr. In addition, as a matter of practice, the radiation
levels in the cab should be maintained as low as reasonably
achievable and not be allowed to reach 2 mrem/hr on a routine
basis.
Recent Examples of NRC Inspection/Enforcement Actions
Effective December 3, 1979, 10 CFR Part 71 was amended to require that all
shipments of radioactive materials made by NRC licensees, other than
shipments subject to the regulations of the U.S. Postal Service, be made in
accordance with the regulations of the U.S. Department of Transportation in
49 CFR Parts 170-189. This amendment permits the Commission to inspect
shipments of radioactive materials and to take enforcement action when
warranted. On December 3, 1979, a letter was sent to all NRC licensees from
the Director, Office of Inspection and Enforcement concerning the criteria
for enforcement action for failure to comply with 10 CFR 71. This letter
also stated that "severity Level I or II noncompliance will normally result
in either civil penalties or more severe enforcement action." (See 44
Federal Register, page 77135, December 31, 1979.)
.
IN 80-32
August 29,1980
Page 7 of 8
NRC inspectors have routinely inspected shipments of radioactive materials
upon arrival at the disposal sites at Barnwell, South Carolina, Beatty,
Nevada and Richland, Washington since September 1979. Enforcement action,
including the imposition of civil penalties, were taken recently against NRC
licensees who made shipments which were not in accordance with the
regulations.
Examples of recent civil penalties imposed on NRC licensees for violations
of 10 CFR 71/49 CFR involving shipments of waste to burial sites are:
1. A $4000 civil penalty against a nuclear utility for excessive radiation
levels (300 mrem/hr) on the surface of a package on an open transport
vehicle (173.393(i), Severity Level II).
2. A $5000.00 civil penalty against a nuclear utility for excessive
radiation levels, (17 mrem/hr) at 6 ft from the sides of an exclusive
use vehicle (173.393(j)(3), Severity Level II)
3. A $1000 civil penalty against a radioisotope supplier for failure to
provide instructions on shipping papers for maintenance of exclusive
use shipment controls (173.392(c)(9), Severity Level II)
4. Three civil penalties totalling $5000 against an industrial laboratory
for use of nonspecification Type A packaging, improper shipping paper
description, and unauthorized transfer of liquids to a burial site
(173.395(a)(1), 172.203(d)(l), and 10 CFR 30.41(b)(c), Severity Levels
II and III)
5. Two civil penalties totalling $8000 against a nuclear utility for
excessive levels of radiation (300 mrem/hr) at the external surface of
a closed vehicle and inadequate surveys of the vehicle (173.393(j)(2)
and 173.393(n)(9), Severity Level II)
6. A $5000 civil penalty against a nuclear utility for excessive radiation
levels (600 mrem/hr) on the surface of an exclusive use vehicle
(173.393(j)(2), Severity Level I)
7. A $4000 civil penalty against a nuclear utility for excessive radiation
levels ( 3.7 mrem/hr) in the truck cab of an exclusive use shipment
(173.393(j)(4), Severity Level II)
8. A $4000 civil penalty against a nuclear utility for excessive radiation
levels (700 mrem/hr) at the bottom surface of a closed transport
vehicle (173.393(j)(2), Severity Level I)
In addition, infractions and deficiences were noted on other shipments.
Noncompliance on matters such as the following were involved:
1. Packages not adequately blocked or braced to prevent shifting
(173.392(c)(6)).
2. Vehicles not placarded or placards not visible (173.393(c)(8),
172.516(a)).
3. Shipping papers not complete (172.203(d)).
.
IN 80-32
August 29, 1980
Page 8 of 8
4. Packages identified as containing solids but actually containing free
standing liquids (violation of burial site licensee requirements and
NRC requirements on transfer of proper form of material, 10 CFR 20.301,
30.41)
5. Packages not marked as "Radioactive LSA" (173.392(c)(8)).
6. Packages of LSA were not strong, tight packages (173.392(c)(l)).
In addition to enforcement actions which may be taken by NRC, actions
against agreement state licensee/shippers may also be taken by DOT or the
states.
Page Last Reviewed/Updated Tuesday, March 09, 2021