Power Reactor Status Report for December 5, 2012

UNEVALUATED INFORMATION PROVIDED BY THE FACILITY

On this page:

Region 1

Unit Power Down Reason or Comment Change in report (*) Number of Scrams (#)
Beaver Valley 1 100   MINIMUM GENERATION ALERT    
Beaver Valley 2 100   MINIMUM GENERATION ALERT    
Calvert Cliffs 1 100   MINIMUM GENERATION ALERT. HIGH SYSTEM VOLTAGE ALERT *  
Calvert Cliffs 2 100   MINIMUM GENERATION ALERT. HIGH SYSTEM VOLTAGE ALERT *  
FitzPatrick 100        
Ginna 100        
Hope Creek 1 100   HIGH VOLTAGE SYSTEM WARNING. MINIMUM GENERATION ALERT *  
Indian Point 2 100   138 KV FEEDER (LINE 33332) OOS    
Indian Point 3 100   138 KV FEEDER (LINE 33332LM) OOS    
Limerick 1 100        
Limerick 2 100        
Millstone 2 100        
Millstone 3 100        
Nine Mile Point 1 80   ROD LINE ADJUSTMENT *  
Nine Mile Point 2 100        
Oyster Creek 99   INCREASING POWER *  
Peach Bottom 2 100   YELLOW GRID DUE TO SBO BKR MAINTENANCE *  
Peach Bottom 3 100   YELLOW GRID DUE TO SBO BKR MAINTENANCE *  
Pilgrim 1 100   MINIMUM GENERATION ALERT *  
Salem 1 100        
Salem 2 100        
Seabrook 1 100        
Susquehanna 1 100   MINIMUM GENERATION ALERT. HIGH SYSTEM VOLTAGE ACTION. *  
Susquehanna 2 100   MINIMUM GENERATION ALERT. HIGH SYSTEM VOLTAGE ACTION. *  
Three Mile Island 1 100   HIGH SYSTEM VOLTAGE ACTION. *  
Vermont Yankee 100   MINIMUM GENERATION ALERT *  

Region 2

Unit Power Down Reason or Comment Change in report (*) Number of Scrams (#)
Browns Ferry 1 23   TURBINE TESTING *  
Browns Ferry 2 100        
Browns Ferry 3 100        
Brunswick 1 100        
Brunswick 2 100        
Catawba 1 0 11/24/2012 REFUELING OUTAGE    
Catawba 2 100        
Crystal River 3 0 09/25/2009 DEFUELED - CONT. TENSIONING ON HOLD    
Farley 1 100        
Farley 2 100        
Harris 1 100        
Hatch 1 100        
Hatch 2 100        
McGuire 1 100        
McGuire 2 74   INCREASING POWER *  
North Anna 1 100        
North Anna 2 100        
Oconee 1 100        
Oconee 2 100        
Oconee 3 100        
Robinson 2 100        
Saint Lucie 1 100        
Saint Lucie 2 85   HOLDING POWER - HTR DRAIN PUMP MAINTENANCE S/G SODIUM ISSUES *  
Sequoyah 1 100     *  
Sequoyah 2 0 10/14/2012 DEFUELED *  
Summer 0 10/12/2012 EXITING REFUELING OUTAGE    
Surry 1 100        
Surry 2 100     *  
Turkey Point 3 100     *  
Turkey Point 4 0 11/04/2012 DEFUELED - REFUELING OUTAGE    
Vogtle 1 100        
Vogtle 2 100        
Watts Bar 1 100        

Region 3

Unit Power Down Reason or Comment Change in report (*) Number of Scrams (#)
Braidwood 1 100        
Braidwood 2 100        
Byron 1 100        
Byron 2 100        
Clinton 97   100% ELECTRICAL CAPABILITY    
D.C. Cook 1 100        
D.C. Cook 2 100        
Davis-Besse 100        
Dresden 2 100        
Dresden 3 15   INCREASING POWER *  
Duane Arnold 0 12/01/2012 GENERATOR FIELD GROUND ISSUE    
Fermi 2 0 11/07/2012 FORCED OUTAGE - SEE EN #48487    
Kewaunee 100        
La Salle 1 100        
La Salle 2 100        
Monticello 100        
Palisades 100        
Perry 1 100        
Point Beach 1 100        
Point Beach 2 100     *  
Prairie Island 1 0 10/22/2012 FUEL LOAD IN PROGRESS *  
Prairie Island 2 100        
Quad Cities 1 100        
Quad Cities 2 100        

Region 4

Unit Power Down Reason or Comment Change in report (*) Number of Scrams (#)
Arkansas Nuclear 1 100        
Arkansas Nuclear 2 100        
Callaway 100        
Columbia Generating Station 100        
Comanche Peak 1 100        
Comanche Peak 2 100        
Cooper 90   HOLD - CONDENSER AIR INLEAKAGE    
Diablo Canyon 1 100     *  
Diablo Canyon 2 100        
Fort Calhoun 0 04/09/2011 DEFUELED - REFUELING OUTAGE    
Grand Gulf 1 100        
Palo Verde 1 100        
Palo Verde 2 100        
Palo Verde 3 100        
River Bend 1 100        
San Onofre 2 0 01/09/2012 REFUELING OUTAGE    
San Onofre 3 0 01/31/2012 DEFUELED - FORCED OUTAGE - S/G REPAIR    
South Texas 1 100        
South Texas 2 100        
Waterford 3 0 10/17/2012 DEFUELED - REFUELING OUTAGE    
Wolf Creek 1 100        